Office of Design
To skip directly to groups of Indexes, click on the index series: 100, 200, 300, 400, 500, 600, 700, 800, 5200, 6000, 11200, 13000, 17300, 17500, 17700, 17900, 18100, 20000, 20500, 20600, 20900, 21100, 21200, 21300, 21600, 21800, 21900 (Site Updated: 8/4/15) | ||||||
---|---|---|---|---|---|---|
Index Number | Revision (DSR) | Index Title | Design Information | |||
Instructions (IDS) | Design Tools | Data Table Cell Library | Borderless DGNs | |||
(PDF) | (PDF) | (Link) | (ZIP) | (ZIP) Terms of Use | ||
Complete eBook 2016 Design Standards eBook Effective Jan 1 - December 31 | Combined IDS | | Combined | Combined DGN | ||
| COVER, TABLE OF CONTENTS AND REVISIONS | | ||||
Cover | | Book Cover | Cover | | | |
Content | | Table of Contents | Content | | | |
Revisions | | Revision History | Introduction | | | |
Revisions | ||||||
| ABBREVIATIONS AND SYMBOLS | | ||||
001 | | Standard Abbreviations | | | | |
002 | | Standard Symbols | | | | |
| EROSION CONTROL AND WATER QUALITY | | ||||
104 | | Permanent Erosion Control | | | | DGN |
105 | | Shoulder Sodding and Turf on Existing Facilities | | | | DGN |
| DRAINAGE | | ||||
| ||||||
200 | | Structure Bottoms - Type J & P | | | | DGN |
201 | | Supplementary Details for Manholes & Inlets | | XLS-WWRConversion | | DGN |
206 | | Trench Drain | | | | DGN |
210 | | Curb Inlet Tops - Types 1, 2, 3 & 4 | | | | DGN |
211 | | Curb Inlet Tops - Types 5 & 6 | | | | DGN |
212 | | Curb Inlet - Type 7 | | | | DGN |
213 | | Curb Inlet - Type 8 | | | | DGN |
214 | | Curb Inlet Top - Type 9 | | | | DGN |
215 | | Curb Inlet Top - Type 10 | | | | DGN |
216 | | Closed Flume Inlet | | | | DGN |
217 | | Median Barrier Inlets Types 1, 2, 3, 4 and 5 | | | | DGN |
218 | | Barrier Wall Inlet | | | | DGN |
219 | | Concrete Barrier Wall Inlet | | | | DGN |
220 | | Gutter Inlet - Type S | | | | DGN |
221 | | Gutter Inlet - Type V | | | | DGN |
230 | | Ditch Bottom Inlet - Type A | | | | DGN |
231 | | Ditch Bottom Inlet - Type B | | | | DGN |
232 | | Ditch Bottom Inlets - Types C, D, E and H | | | | DGN |
233 | | Ditch Bottom Inlets - Types F and G | | | | DGN |
234 | | Ditch Bottom Inlet - Type J | | | | DGN |
235 | | Ditch Bottom Inlet - Type K | | | | DGN |
240 | | Skimmer for Outlet Control Structures | IDS | | | DGN |
241 | | Skimmers for Frenchdrain Outlets | | | | DGN |
245 | | Underdrain Inspection Box | | | | DGN |
250 | | Straight Concrete Endwalls - Single and Multiple Pipe | | | | DGN |
251 | | Straight Concrete Endwalls - Single and Double 60" Pipe | | | | DGN |
252 | | Straight Concrete Endwalls - Single and Double 66" Pipe | | | | DGN |
253 | | Straight Concrete Endwalls - Single and Double 72" Pipe | | | | DGN |
255 | | Straight Concrete Endwalls - Single 84" Pipe | | | | DGN |
258 | | Straight Sand - Cement Endwalls | | | | DGN |
260 | | U-Type Concrete Endwalls With Grates - 15" to 30" Pipe | | | | DGN |
261 | | U-Type Concrete Endwalls - Baffles and Grate Optional - 15" to 30" Pipe | | | | DGN |
264 | | U-Type Concrete Endwall - Energy Dissipator - 30" to 72" Pipe | | | | DGN |
266 | | Winged Concrete Endwalls - Single Round Pipe | | | | DGN |
268 | | U-Type Sand-Cement Endwalls | | | | DGN |
270 | | Flared End Section | IDS | | | DGN |
272 | | Cross Drain Mitered End Section | | | | DGN |
273 | | Side Drain Mitered End Section | | | | DGN |
280 | | Miscellaneous Drainage Details | | | | DGN |
281 | | Ditch Pavement and Sodding | | | | DGN |
282 | | Back of Sidewalk Drainage | | | | DGN |
283 | | Median Opening Flume | | | | DGN |
284 | | Concrete Shoulder Gutter Spillway | | | | DGN |
285 | | French Drain | | | | DGN |
286 | | Underdrain | | | | DGN |
287 | | Concrete Pavement Subdrainage | | | | DGN |
288 | | Deep Well Injection Box | | | | DGN |
289 | | Concrete Box Culvert Details (LRFD) | IDS | PGM | CEL | DGN |
291 | | Supplemental Details for Precast Concrete Box Culverts | IDS | | | DGN |
292 | | Standard Precast Concrete Box Culverts | IDS | | | DGN |
293 | | Safety Modifications for Inlets In Box Culverts | | | | DGN |
295 | | Safety Modifications for Endwalls | | | | DGN |
| CURBS, CONCRETE PAVEMENT & SIDEWALKS | | ||||
300 | | Curb & Curb And Gutter | | | | DGN |
301 | | Turn Lanes | | | | DGN |
302 | | Traffic Separators | IDS | | | DGN |
303 | | Curb Return Profiles | | | | DGN |
304 | | Detectable Warnings and Sidewalk Curb Ramps | IDS | | | DGN |
305 | | Concrete Pavement Joints | | | | DGN |
306 | | Bridge Approach Expansion Joint - Concrete Pavement | | | | DGN |
307 | | Miscellaneous Utility Details | | | | DGN |
308 | | Concrete Slab Replacement | | | | DGN |
310 | | Concrete Sidewalk | | | | DGN |
| TRAFFIC RAILINGS | | ||||
| ||||||
400 | | Guardrail | IDS | | | DGN |
402 | | Guardrail Transitions and Connections for Existing Bridges | IDS | | | DGN |
403 | | Guardrail Transitions for Existing Bridge Traffic Railing Retrofits | IDS | | | DGN |
404 | | Guardrail Transitions - Existing Post & Beam Bridge Railings (Narrow & Recessed Curbs) | IDS | | | DGN |
405 | | Guardrail Transitions - Existing Post & Beam Bridge Railings (Wide Curbs) | IDS | | | DGN |
410 | | Concrete Barrier Wall | | | | DGN |
411 | | Pier Protection Barrier | IDS | | | DGN |
412 | | Low Profile Barrier | | | | DGN |
414 | | Type K Temporary Concrete Barrier System | IDS | | | DGN |
415 | | Temporary Concrete Barrier | | | | DGN |
420 | | Traffic Railing - (32" F Shape) | IDS | | | DGN |
421 | | Traffic Railing - (Median 32" F Shape) | IDS | | | DGN |
422 | | Traffic Railing - (42" Vertical Shape) | IDS | | | DGN |
423 | | Traffic Railing - (32" Vertical Shape) | IDS | | | DGN |
424 | | Traffic Railing - (Corral Shape) | IDS | | | DGN |
425 | | Traffic Railing - (42" F Shape) | IDS | | | DGN |
430 | | Crash Cushion Details | IDS | | | DGN |
461 | | Opaque Visual Barrier | | | | DGN |
470 | | Traffic Railing - (Thrie Beam Retrofit) General Notes & Details | IDS | | | DGN |
471 | | Traffic Railing - (Thrie Beam Retrofit) Narrow Curb | | | DGN | |
472 | | Traffic Railing - (Thrie Beam Retrofit) Wide Strong Curb Type 1 | | | DGN | |
473 | | Traffic Railing - (Thrie Beam Retrofit) Wide Strong Curb Type 2 | | | DGN | |
474 | | Traffic Railing - (Thrie Beam Retrofit) Intermediate Curb | | | DGN | |
475 | | Traffic Railing - (Thrie Beam Retrofit) Wide Curb Type 1 | | | DGN | |
476 | | Traffic Railing - (Thrie Beam Retrofit) Wide Curb Type 2 | | | DGN | |
477 | | Thrie-Beam Panel Retrofit (Concrete Handrail) | IDS | | | DGN |
480 | | Traffic Railing - (Vertical Face Retrofit) General Notes & Details | IDS | | | DGN |
481 | | Traffic Railing - (Vertical Face Retrofit) Narrow Curb | | | DGN | |
482 | | Traffic Railing - (Vertical Face Retrofit) Wide Curb | | | DGN | |
483 | | Traffic Railing - (Vertical Face Retrofit) Intermediate Curb | | | DGN | |
484 | | Traffic Railing - (Vertical Face Retrofit) Spread Footing Approach | | | DGN | |
| | |||||
| ||||||
500 | | Removal of Organic and Plastic Material | | | | DGN |
505 | | Embankment Utilization | | | | DGN |
506 | | Miscellaneous Earthwork Details | | | | DGN |
510 | | Superelevation - Rural Highways, Urban Freeways and High Speed Urban Highways | | | | DGN |
511 | | Superelevation - Urban Highways and Streets | | | | DGN |
514 | | Optional Base Group and Structural Numbers | | | | DGN |
515 | | Turnouts | | | | DGN |
516 | | Turnouts - Resurfacing Projects | | | | DGN |
517 | | Raised Rumble Strips | | | | DGN |
518 | | Shoulder Rumble Strips | | | | DGN |
519 | | Rumble Striping | IDS | | | DGN |
521 | | Concrete Steps | IDS | | | DGN |
525 | | Ramp Terminals | | | | DGN |
526 | | Roadway Transitions | | | | DGN |
527 | | Directional Median Openings | | | | DGN |
530 | | Rest Area Pavilion | | | | DGN |
532 | | Mailboxes | | | | DGN |
535 | | Tractor Crossings | | | | DGN |
540 | | Settlement Plate | | | | DGN |
544 | | Landscape Installation | | | | DGN |
546 | | Sight Distance at Intersections | | | | DGN |
560 | | Railroad Crossings | | | | DGN |
| TRAFFIC CONTROL THROUGH WORK ZONES | | ||||
600 | | General Information for Traffic Control Through Work Zones | | | | DGN |
601 | | Two-Lane, Two-Way, Work Outside Shoulder | | | | DGN |
602 | | Two-Lane, Two-Way, Work on Shoulder | | | | DGN |
603 | | Two-Lane, Two-Way, Work Within the Travel Way | | | | DGN |
604 | | Two-Lane, Two-Way, Work in intersection | | | | DGN |
605 | | Two-Lane, Two-Way, Work Near Intersection | | | | DGN |
606 | | Two-Lane, Two-Way, Work Within the Travel Way - Signal Control | | | | DGN |
607 | | Two-Lane, Two-Way, Mobile Operation, Work on Shoulder, Work Within the Travel Way | | | | DGN |
608 | | Two-Lane, Two-Way, Temporary Diversion Connection | | | | DGN |
611 | | Multilane, Work Outside Shoulder | | | | DGN |
612 | | Multilane, Work on Shoulder | | | | DGN |
613 | | Multilane, Work Within the Travel Way - Median or Outside Lane | | | | DGN |
614 | | Multilane, Work Within the Travel Way - Center Lane | | | | DGN |
615 | | Multilane, Work in Intersection | | | | DGN |
616 | | Multilane, Work Near Intersection - Median or Outside Lane | | | | DGN |
617 | | Multilane, Work in Intersection - Center Lane | | | | DGN |
618 | | Multilane, Work in Intersection - Two Lanes Closed - 45 mph or Less | | | | DGN |
619 | | Multilane, Mobile Operations, Work on Shoulder, Work Within the Travel Way | | | | DGN |
620 | | Multilane, Divided, Temporary Diversion Connection | | | | DGN |
621 | | Multilane, Undivided, Temporary Diversion Connection | | | | DGN |
622 | | Multilane, Work Near Intersection-Temporary Diversion Connection-35 mph or Less | | | | DGN |
623 | | Multilane, Work Within the Travel Way Double Lane Closure | | | | DGN |
625 | | Temporary Road Closure - 5 Minutes or Less | | | | DGN |
628 | | Two-Way Left Turn Lane Closure | | | | DGN |
630 | | Crossover for Paving Train Operations, Rural | | | | DGN |
631 | | Temporary Crossover | | | | DGN |
640 | | Converting Two-Lanes to Four-Lanes Divided, Rural | | | | DGN |
641 | | Converting Two-Lanes to Four-Lanes Divided, Urban | | | | DGN |
642 | | Transitions for Temporary Concrete Barrier Wall on Freeway Facilities | | | | DGN |
650 | | Two-Lane, Two-Way Rural Structure Replacement | | | | DGN |
651 | | Multilane, Divided, Maintenance and Construction | | | | DGN |
655 | | Traffic Pacing | | | | DGN |
660 | | Pedestrian Control for Closure of Sidewalks | | | | DGN |
665 | | Limited Access, Temporary Opening | | | | DGN |
667 | | Toll Plaza, Traffic Control Standards | | | | DGN |
670 | | Motorist Awareness System | | | | DGN |
| ROADSIDE SAFETY | | ||||
700 | | Roadside Offsets | IDS | | | DGN |
| FENCING AND PEDESTRIAN RAILINGS
| | ||||
| ||||||
800 | | Fence Location | | | | DGN |
801 | | Fence - Type A | | | | DGN |
802 | | Fence - Type B | | | | DGN |
803 | | Cantilever Slide Gate - Type B Fence | | | | DGN |
810 | | Bridge Fencing (Vertical) | IDS | | | DGN |
811 | | Bridge Fencing (Curved Top) | IDS | | | DGN |
812 | | Bridge Fencing (Enclosed) | IDS | | | DGN |
820 | | 27" Concrete Parapet Pedestrian/Bicycle with Bullet Railing | IDS | | | DGN |
821 | | Bridge Aluminum Pedestrian/Bicycle Bullet Railing for Traffic Railing (32" F Shape) | IDS | | | DGN |
822 | | Bridge Aluminum Pedestrian/Bicycle Bullet Railing Details | IDS | | | DGN |
825 | | 42" Concrete Pedestrian/Bicycle Railing | IDS | | | DGN |
851 | | Bridge Pedestrian/Bicycle Railing (Steel) | IDS | | | DGN |
852 | | Steel Pedestrian/Bicycle Railing | IDS | | CEL CEL-CTIP | DGN |
861 | | Bridge Pedestrian/Bicycle Railing (Aluminum) | IDS | | | DGN |
862 | | Aluminum Pedestrian/Bicycle Railing | IDS | | CEL CEL-CTIP | DGN |
870 | | Aluminum Pipe Guiderail | IDS | | | DGN |
880 | | Steel Pipe Guiderail | IDS | | | DGN |
| NOISE AND PERIMETER WALL SYSTEMS
| | ||||
5200 | | Precast Noise Walls | IDS | | CEL CELGraphics | DGN |
5210 | | Traffic Railing/Noise Wall (8'-0") | IDS | | | DGN |
5211 | | Traffic Railing/Noise Wall (14'-0") | IDS | | | DGN |
5212 | | Traffic Railing/Noise Wall (8'-0") Junction Slab | IDS | | | DGN |
5213 | | Traffic Railing/Noise Wall T-Shape Spread Footing | IDS | | | DGN |
5214 | | Traffic Railing/Noise Wall L-Shaped Spread Footing | IDS | | | DGN |
5215 | | Traffic Railing/Noise Wall Trench Footing | IDS | | | DGN |
5250 | | Perimeter Walls | IDS | | CEL | DGN |
| WALL SYSTEMS
| | ||||
6010 | | C-I-P Cantilever Retaining Wall | IDS | PGM | CEL | DGN |
6011 | | Gravity Wall | IDS | | | DGN |
6020 | | Permanent MSE Retaining Wall Systems | IDS | | CEL | DGN |
6030 | | Temporary MSE Retaining Wall Systems | IDS | | CEL | DGN |
6040 | | Precast Concrete Sheet Pile Wall | IDS | | CEL-CSPDA CEL-CSPC | DGN |
6100 | | MSE Wall Coping (Precast or C-I-P) | IDS | | | DGN |
6110 | | Wall Coping With Traffic Railing/Junction Slab | | | DGN | |
6120 | | Wall Coping With Traffic Railing/Raised Sidewalk | | | DGN | |
6130 | | Wall Coping/Parapet With C-I-P Sidewalk | | | DGN | |
6200 | | Coping Mounted Light Pole Pedestal | | | | DGN |
6201 | | Junction Slab at Drainage Inlet Openings | | | | DGN |
| SIGNING AND MARKING | | ||||
11200 | | Multi-Column Ground Sign | IDS | PGM | | DGN |
11300 | | Steel Overhead Sign Structures | IDS | | | DGN |
11310 | | Cantilever Sign Structure | IDS | PGM | CEL | DGN |
11320 | | Span Sign Structure | IDS | PGM | CEL | DGN |
11860 | | Single Column Ground Signs | IDS | | | DGN |
11861 | | Single Column Cantilever Ground Mounted Sign | IDS | | | DGN |
11862 | | Roadside Flashing Beacon Assembly | | | | DGN |
11870 | | Single Post Bridge Mounted Sign Support | IDS | | | DGN |
11871 | | Single Post Median Barrier Mounted Sign Support | IDS | | | DGN |
13417 | | Mounting Exit Number Panels to Highway Signs | | | | DGN |
17302 | | Typical Sections for Placement of Single & Multi-Column Signs | | | | DGN |
17328 | | Typical Signing for Truck Weigh and Inspection Stations | | | | DGN |
17344 | | School Signs & Markings | | | | DGN |
17345 | | Interchange Markings | | | | DGN |
17346 | | Special Marking Areas | | | | DGN |
17347 | | Bicycle Markings | IDS | | | DGN |
17349 | | Traffic Controls for Street Terminations | | | | DGN |
17350 | | Signing for Motorist Services | | | | DGN |
17351 | | Welcome Center Signing | | | | DGN |
17352 | | Typical Placement of Reflective Pavement Markers | | | | DGN |
17354 | | Tourist Oriented Directional Signs | | | | DGN |
17355 | | Special Sign Details | | | | DGN |
17356 | | Span Wire Mounted Sign Details | | | | DGN |
17357 | | Bridge Weight Restrictions | | | | DGN |
17359 | | Rural Narrow Bridge Treatment | | | | DGN |
| ROADWAY LIGHTING
| | ||||
17500 | | Conventional Lighting | | | | DGN |
17501 | | Highway Lighting General Notes | | | | DGN |
17502 | | High Mast Lighting | IDS | PGM | | DGN |
17504 | | Service Point Details | | | | DGN |
17505 | | External Lighting for Signs | IDS | | | DGN |
17515 | | Standard Aluminum Lighting | IDS | | | DGN |
| TRAFFIC SIGNAL AND EQUIPMENT
| | ||||
17700 | | Pull and Splice Box | | | | DGN |
17721 | | Conduit Installation Details | | | | DGN |
17723 | | Steel Strain Pole | IDS | PGM | | DGN |
17725 | | Concrete Poles | IDS | PGM | | DGN |
17727 | DSR | Signal Cable and Span Wire Installation Details | | | | DGN |
17733 | | Aerial Interconnect | | | | DGN |
17736 | | Electric Power Service | | | | DGN |
17743 | | Standard Mast Arm Assemblies | IDS | PGM | CEL | DGN |
17745 | | Mast Arm Assemblies | IDS | PGM | CEL | DGN |
17748 | | Free-Swinging, Internally-Illuminated Street Sign Assemblies | | | | DGN |
17764 | | Pedestrian Control Signal Installation Details | | | | DGN |
17781 | | Vehicle Loop Installation Details | | | | DGN |
17784 | | Pedestrian Detector Assembly Installation Details | | | | DGN |
17841 | | Cabinet Installation Details | | | | DGN |
17870 | | Standard Signal Operating Plans | | | | DGN |
17881 | | Advance Warning for R/R Crossing | | | | DGN |
17882 | | Railroad Grade Crossing Traffic Control Devices | | | | DGN |
17890 | | Traffic Control Devices for Movable Span Bridge Signals | | | | DGN |
| | |||||
17900 | | Traffic Monitoring Site | IDS | | | DGN |
| INTELLIGENT TRANSPORTATION SYSTEMS
| | ||||
18100 | | CCTV Pole Placement | | | | DGN |
18101 | | Typical CCTV Site | | | | DGN |
18102 | | Grounding and Lightning Protection | | | | DGN |
18104 | | Typical CCTV Cabinet Equipment Layout | | | | DGN |
18105 | | CCTV Block Diagram | | | | DGN |
18107 | | Ground Mounted CCTV Cabinet | | | | DGN |
18108 | | Pole Mounted CCTV Cabinet | | | | DGN |
18110 | | Camera Mounting Details | | | | DGN |
18111 | | Steel CCTV Pole | IDS | | | DGN |
18113 | | Concrete CCTV Pole | IDS | | | DGN |
18300 | | Dynamic Message Sign Walk-In | | | | DGN |
| PRESTRESSED CONCRETE BEAMS
| | ||||
20010 | | Typical Florida-I Beam Details and Notes | IDS | PGM | CEL | DGN |
20036 | | Florida-I 36 Beam - Standard Details | DGN | |||
20045 | | Florida-I 45 Beam - Standard Details | DGN | |||
20054 | | Florida-I 54 Beam - Standard Details | DGN | |||
20063 | | Florida-I 63 Beam - Standard Details | DGN | |||
20072 | | Florida-I 72 Beam - Standard Details | DGN | |||
20078 | | Florida-I 78 Beam - Standard Details | DGN | |||
20084 | | Florida-I 84 Beam - Standard Details | DGN | |||
20096 | | Florida-I 96 Beam - Standard Details | DGN | |||
20120 | | AASHTO Type II Beam | IDS | PGM | CEL | DGN |
20199 | | Build-Up & Deflection Data for Prestressed I-Beams | IDS | | CEL | DGN |
20210 | | Typical Florida-U Beam Details and Notes | IDS | PGM | CEL | DGN |
20248 | | Florida-U 48 Beam - Standard Details | DGN | |||
20254 | | Florida-U 54 Beam - Standard Details | DGN | |||
20263 | | Florida-U 63 Beam - Standard Details | DGN | |||
20272 | | Florida-U 72 Beam - Standard Details | DGN | |||
20299 | | Build-up and Deflection Data for Florida-U Beams | IDS | | CEL | DGN |
| | |||||
20502 | | Beveled Bearing Plate Details - Prestressed Florida-U Beams | IDS | | CEL | DGN |
20510 | | Composite Elastomeric Bearing Pads - Prestressed Florida-I & AASHTO Type II Beams | IDS | | CEL | DGN |
20511 | | Bearing Plates (Type I) - Prestressed Florida-I & AASHTO Type II Beams | IDS | | CEL | DGN |
20512 | | Bearing Plates (Type 2) - Prestressed Florida-I & AASHTO Type II Beams | IDS | | CEL | DGN |
| SQUARE AND ROUND CONCRETE PILES
| | ||||
20600 | | Notes and Details for Square Prestressed Concrete Piles | IDS | | CEL | DGN |
20601 | | Square Prestressed Concrete Pile Splices | DGN | |||
20602 | | EDC Instrumentation for Square Prestressed Concrete Piles | DGN | |||
20612 | | 12'' Square Prestressed Concrete Pile | DGN | |||
20614 | | 14'' Square Prestressed Concrete Pile | DGN | |||
20618 | | 18'' Square Prestressed Concrete Pile | DGN | |||
20620 | | 20'' Square Prestressed Concrete Pile | DGN | |||
20624 | | 24'' Square Prestressed Concrete Pile | DGN | |||
20630 | | 30'' Square Prestressed Concrete Pile | DGN | |||
20631 | | High Moment Capacity 30'' Square Prestressed Concrete Pile | DGN | |||
20654 | | 54'' Precast/Post-Tensioned Concrete Cylinder Pile | IDS | DGN | ||
20660 | | 60'' Prestressed Concrete Cylinder Pile | IDS | DGN | ||
| APPROACH SLABS
| | ||||
20900 | | Approach Slabs (Flexible Pavement Approaches) | IDS | | CEL | DGN |
20910 | | Approach Slabs (Rigid Pavement Approaches) | IDS | | CEL | DGN |
| | |||||
21100 | | Strip Seal Expansion Joint | IDS | | CEL | DGN |
21110 | | Poured Joint With Backer Rod Expansion Joint System | IDS | | CEL | DGN |
| STRUCTURES ACCESS AND LIGHTING
| | ||||
21200 | | Light Pole Pedestal | IDS | | | DGN |
21210 | | Conduit Details | IDS | | | DGN |
21220 | | Navigation Light System Details (Fixed Bridges) | IDS | | | DGN |
21240 | | Maintenance Lighting for Box Girders | IDS | | | DGN |
21250 | | Access Hatch Assembly for Steel Box Sections | IDS | | | DGN |
21251 | | Access Hatch Assembly for Concrete Box Sections | | | DGN | |
21252 | | Access Door Assembly for Steel Box Sections | IDS | | CEL | DGN |
| STANDARD BAR BENDING DETAILS
| | ||||
21300 | | Standard Bar Bending Details | IDS | | | DGN |
| TEMPORARY DETOUR BRIDGES
| | ||||
21600 | | Temporary Detour Bridge General Notes and Details | IDS | | CEL | DGN |
21610 | | Temporary Detour Bridge Details -Timber Pile Foundations | DGN | |||
21620 | | Temporary Detour Bridge Details -Steel H Pile Foundations | DGN | |||
21630 | | Temporary Detour Bridge Details -Steel Pipe Pile Foundations | DGN | |||
21640 | | Temporary Detour Bridge Thrie-Beam Guardrail | DGN | |||
| POST-TENSIONING
| | ||||
21801 | | Post-Tensioning Vertical Profiles | IDS | | CEL-b CEL-t | DGN |
21802 | | Post-Tensioning Anchorage Protection | DGN | |||
21803 | | Post-Tensioning Anchorage and Tendon Filling Details | DGN | |||
| FENDER SYSTEM DETAILS
| | ||||