Design Standards 2002
Index No. | Sheet No. | Filename | Description |
---|---|---|---|
* COVER AND INTRODUCTION * | |||
Book | 1-631 of 631 | CompleteBook (125mb) | 2002 Design Standards Book |
- | 1-2 of 2 | Cover02.pdf | 2002 Design Standards book Cover |
- | 1-2 of 2 | Revisions02.pdf | 2002 Design Standards book Revision History |
- | 1-2 of 2 | Contents02.pdf | 2002 Design Standards book Table of Contents |
* ABBREVIATIONS AND SYMBOLS * | |||
001 | 1-2 of 2 | 001.pdf | Standard Abbreviations |
002 | 1-3 of 3 | 002.pdf | Standard Symbols |
* EROSION CONTROL AND WATER QUALITY * | |||
100 | 1 of 1 | 100.pdf | Temporary Slope Drain And Sod Flume |
101 | 1 of 1 | 101.pdf | Trash Retainer And Sediment Basin |
102 | 1-3 of 3 | 102.pdf | Temporary Erosion And Sediment Control |
103 | 1 of 1 | 103.pdf | Turbidity Barriers |
104 | 1-2 of 2 | 104.pdf | Permanent Erosion Control |
105 | 1 of 1 | 105.pdf | Shoulder Sodding And Reworking On Existing Facilities |
106 | 1 of 1 | 106.pdf | Soil Tracking Prevention Device Type A |
199 | 1 of 1 | 199.pdf | Geotextile Criteria |
* DRAINAGE * | |||
199 | 1 of 1 | 199.pdf | Geotextile Criteria |
200 | 1-2 of 2 | 200.pdf | Structure Bottoms - Type J And P |
201 | 1-6 of 6 | 201.pdf | Supplementary Details For Manholes And Inlets |
205 | 1-5 of 5 | 205.pdf | Cover Height |
210 | 1 of 1 | 210.pdf | Curb Inlet Tops - Types 1, 2, 3 And 4 |
211 | 1-2 of 2 | 211.pdf | Curb Inlet Tops - Types 5 And 6 |
212 | 1 of 1 | 212.pdf | Curb Inlet - Type 7 |
213 | 1 of 1 | 213.pdf | Curb Inlet - Type 8 |
214 | 1 of 1 | 214.pdf | Curb Inlet Top - Type 9 |
215 | 1 of 1 | 215.pdf | Curb Inlet Top - Type 10 |
216 | 1-3 of 3 | 216.pdf | Closed Flume Inlet |
217 | 1 of 1 | 217.pdf | Median Barrier Inlets Types 1, 2, 3, 4 And 5 |
218 | 1-2 of 2 | 218.pdf | Barrier Wall Inlet |
219 | 1-2 of 2 | 219.pdf | Barrier Wall Inlet - Barrier Wall, Concrete ( Rigid ) (C & G) |
220 | 1 of 1 | 220.pdf | Gutter Inlet - Type S |
221 | 1 of 1 | 221.pdf | Gutter Inlet - Type V |
230 | 1 of 1 | 230.pdf | Ditch Bottom Inlet - Type A |
231 | 1-2 of 2 | 231.pdf | Ditch Bottom Inlet - Type B |
232 | 1-5 of 5 | 232.pdf | Ditch Bottom Inlets - Types C, D, E And H |
233 | 1 of 1 | 233.pdf | Ditch Bottom Inlets - Types F And G |
234 | 1 of 1 | 234.pdf | Ditch Bottom Inlet - Type J |
235 | 1 of 1 | 235.pdf | Ditch Bottom Inlet - Type K |
240 | 1-2 of 2 | 240.pdf | Skimmer For Outlet Control Structures |
245 | 1 of 1 | 245.pdf | Underdrain Inspection Box |
250 | 1-2 of 2 | 250.pdf | Straight Concrete Endwalls - Single And Multiple Pipe |
251 | 1-2 of 2 | 251.pdf | Straight Concrete Endwalls - Single And Double 60" Pipe |
252 | 1-2 of 2 | 252.pdf | Straight Concrete Endwalls - Single And Double 66" Pipe |
253 | 1-2 of 2 | 253.pdf | Straight Concrete Endwalls - Single And Double 72" Pipe |
255 | 1 of 1 | 255.pdf | Straight Concrete Endwall - Single 84" Pipe |
258 | 1 of 1 | 258.pdf | Straight Sand - Cement Endwalls |
260 | 1 of 1 | 260.pdf | U-Type Concrete Endwalls With Grates - 15" To 30" Pipe |
261 | 1-3 of 3 | 261.pdf | U-Type Concrete Endwalls - Baffles And Grate Optional - 15" To 30" Pipe |
264 | 1 of 1 | 264.pdf | U-Type Concrete Endwall - Energy Dissipator - 30" To 72" Pipe |
266 | 1 of 1 | 266.pdf | Winged Concrete Endwalls - Single Round Pipe |
268 | 1 of 1 | 268.pdf | U-Type Sand-Cement Endwalls |
270 | 1 of 1 | 270.pdf | Flared End Section |
272 | 1-6 of 6 | 272.pdf | Cross Drain Mitered End Section |
273 | 1-6 of 6 | 273.pdf | Side Drain Mitered End Section |
280 | 1-4 of 4 | 280.pdf | Miscellaneous Drainage Details |
281 | 1-2 of 2 | 281.pdf | Ditch Pavement And Sodding |
282 | 1 of 1 | 282.pdf | Back Of Sidewalk Drainage |
283 | 1 of 1 | 283.pdf | Median Opening Flume |
284 | 1 of 1 | 284.pdf | Concrete Spillways |
285 | 1-2 of 2 | 285.pdf | French Drain |
286 | 1-2 of 2 | 286.pdf | Underdrain |
287 | 1-3 of 3 | 287.pdf | Concrete Pavement Subdrainage |
290 | 1-5 of 5 | 290.pdf | Concrete Box Culvert |
293 | 1 of 1 | 293.pdf | Safety Modifications For Inlets In Box Culverts |
295 | 1 of 1 | 295.pdf | Safety Modifications For Endwalls |
* CURBS, CONCRETE PAVEMENT AND SIDEWALKS * | |||
300 | 1 of 1 | 300.pdf | Curb & Curb And Gutter |
301 | 1 of 1 | 301.pdf | Turn Lanes |
302 | 1 of 1 | 302.pdf | Traffic Separators |
303 | 1 of 1 | 303.pdf | Curb Return Profiles |
304 | 1-5 of 5 | 304.pdf | Public Sidewalk Curb Ramps |
305 | 1-4 of 4 | 305.pdf | Concrete Pavement Joints |
306 | 1 of 1 | 306.pdf | Bridge Approach Expansion Joint - Concrete Pavement |
307 | 1 of 1 | 307.pdf | Utility Cut |
310 | 1-2 of 2 | 310.pdf | Concrete Sidewalk |
* TRAFFIC RAILINGS * | |||
400 | 1-16 of 32 | 400s1-16of32.pdf | Guardrail |
17-32 of 32 | 400s17-32of32.pdf | Guardrail | |
410 | 1-11 of 22 | 410s1-11of22.pdf | Concrete Barrier Wall |
12-22 of 22 | 410s12-22of22.pdf | Concrete Barrier Wall | |
415 | 1-4 of 4 | 415.pdf | Precast Concrete Temporary Barrier Wall |
416 | 1-5 of 5 | 416.pdf | Temporary Water Filled Barriers |
417 | 1 of 1 | 417.pdf | Inertial Crash Cushion |
432 | 1-2 of 2 | 432.pdf | C-A-T 350 |
433 | 1-4 of 4 | 433.pdf | Brakemaster 350 |
434 | 1 of 1 | 434.pdf | REACT 350 |
435 | 1-6 of 6 | 435.pdf | QuadGuard |
436 | 1 of 1 | 436.pdf | ADIEM 350 |
438 | 1-2 of 2 | 438.pdf | Dragnet |
440 | 1-5 of 5 | 440.pdf | TRACC Systems |
450 | 1-2 of 2 | 450.pdf | Fence Location |
451 | 1-2 of 2 | 451.pdf | Fence - Type A |
452 | 1-2 of 2 | 452.pdf | Fence - Type B |
453 | 1 of 1 | 453.pdf | Cantilever Slide Gate - Type B Fence |
461 | 1 of 1 | 461.pdf | Opaque Visual Barrier |
* GENERAL * | |||
500 | 1-2 of 2 | 500.pdf | Removal Of Organic And Plastic Material |
501 | 1-8 of 8 | 501.pdf | Geosynthetic Reinforced Soils |
505 | 1-3 of 3 | 505.pdf | Embankment Utilization |
506 | 1 of 1 | 506.pdf | Miscellaneous Earthwork Details |
510 | 1-2 of 2 | 510.pdf | Superelevation - Rural Highways, Urban Freeways And High Speed Urban Highways |
511 | 1-3 of 3 | 511.pdf | Superelevation - Urban Highways And Streets |
514 | 1-2 of 2 | 514.pdf | Optional Base Group And Structural Numbers |
515 | 1-6 of 6 | 515.pdf | Turnouts |
516 | 1 of 1 | 516.pdf | Turnouts - Resurfacing Projects |
518 | 1-2 of 2 | 518.pdf | Rumble Strips |
520 | 1of 1 | 520.pdf | Gravity Wall |
521 | 1of 1 | 521.pdf | Aluminum Pipe Handrails And Concrete Steps |
525 | 1-5 of 5 | 525.pdf | Ramp Terminals |
526 | 1-8 of 8 | 526.pdf | Roadway Transitions |
530 | 1-3 of 3 | 530.pdf | Rest Area Equipment |
532 | 1-3 of 3 | 532.pdf | Mailboxes |
535 | 1 of 1 | 535.pdf | Tractor Crossings |
540 | 1 of 1 | 540.pdf | Settlement Plate |
544 | 1 of 1 | 544.pdf | Landscape Installation |
546 | 1-2 of 2 | 546.pdf | Sight Distance At Intersections |
560 | 1-5 of 5 | 560.pdf | Railroad Crossings |
* TRAFFIC CONTROL THROUGH WORK ZONES * | |||
600 | 1-10 of 10 | 600.pdf | General Information For Traffic Control Through Work Zones |
601 | 1 of 1 | 601.pdf | Two-Lane, Two-Way Rural Day Or Night Operations |
602 | 1 of 1 | 602.pdf | Two-Lane, Two-Way Rural Day Or Night Operations |
603 | 1-2 of 2 | 603.pdf | Two-Lane, Two-Way Rural Operations One Daylight Period Or Less |
604 | 1 of 1 | 604.pdf | Two-Lane, Two-Way Rural Night Operations Or Operations Exceeding One Daylight Period |
605 | 1 of 1 | 605.pdf | Two-Lane, Two-Way Rural Moving Operations - Daylight Only |
606 | 1 of 1 | 606.pdf | Two-Lane, Two-Way Rural Moving Operations - Daylight Only |
607 | 1 of 1 | 607.pdf | Two-Lane, Two-Way Rural Short-Time Day Or Night Operations |
608 | 1-4 of 4 | 608.pdf | Two-Lane, Two-Way Lane Closure By Signal Control, Day Or Night Operations |
609 | 1 of 1 | 609.pdf | Two-Lane, Two-Way Rural Temporary Connection Day Or Night Operations |
610 | 1 of 1 | 610.pdf | Multilane, Divided Or Undivided Rural Day Or Night Operations |
611 | 1 of 1 | 611.pdf | Multilane, Divided Or Undivided Rural Day Or Night Operations |
612 | 1 of 1 | 612.pdf | Multilane, Divided And Undivided Rural, Operations One Daylight Period Or Less |
613 | 1-2 of 2 | 613.pdf | Multilane, Divided And Undivided Rural Night Operations Or Operations Exceeding One Daylight Period |
614 | 1-2 of 2 | 614.pdf | Multilane Divided Rural Day Or Night Operations |
615 | 1 of 1 | 615.pdf | Multilane Undivided Rural Day Or Night Operations |
616 | 1-2 of 2 | 616.pdf | Multilane Divided Rural |
617 | 1 of 1 | 617.pdf | Multilane Divided Rural |
620 | 1 of 1 | 620.pdf | Two-Lane, Two-Way Urban Day Or Night Operations |
621 | 1 of 1 | 621.pdf | Two-Lane, Two-Way Urban Day Or Night Operations |
622 | 1 of 1 | 622.pdf | Multilane, Two-Way Urban Divided Or Undivided Day Or Night Operations |
623 | 1-2 of 2 | 623.pdf | Multilane, Two-Way Urban Divided Or Undivided Day Or Night Operations |
624 | 1 of 1 | 624.pdf | Multilane, Divided With Traversable Median Or Undivided, Urban Day Or Night Operations |
625 | 1-2 of 2 | 625.pdf | Multilane One-Way Or Multilane Divided With Non-Traversable Median Urban Day Or Night Operations |
626 | 1 of 1 | 626.pdf | Multilane One-Way Or Multilane Divided With Non-Traversable Median Urban Day Or Night Operations |
627 | 1 of 1 | 627.pdf | Moving Operations |
628 | 1 of 1 | 628.pdf | Two-Way Left Turn Lane Closure |
630 | 1-2 of 2 | 630.pdf | Temporary Crossover For Paving Train Operations, Rural |
631 | 1-2 of 2 | 631.pdf | Temporary Crossover |
640 | 1-2 of 2 | 640.pdf | Converting Two-Lanes To Four-Lanes Divided Rural |
641 | 1-2 of 2 | 641.pdf | Converting Two-Lanes To Four-Lanes Divided Urban |
642 | 1 of 1 | 642.pdf | Transitions For Temporary Concrete Barrier Wall On Freeway Facilities |
650 | 1-2 of 2 | 650.pdf | Two-Lane, Two-Way Rural Structure Replacement |
651 | 1-2 of 2 | 651.pdf | Multilane Divided Maintenance And Construction |
660 | 1 of 1 | 660.pdf | Pedestrian Control For Closure Of Sidewalks |
665 | 1 of 1 | 665.pdf | Limited Access Right Of Way Temporary Opening |
670 | 1 of 1 | 670.pdf | Motorist Awareness System |
* WALL AND SOUND BARRIER SYSTEM * | |||
5000 | 1 of 1 | 5000.pdf | Permanent And Temporary Walls - General Wall Notes |
5005 | 1-12 of 12 | 5005.pdf | Permanent Walls - Retained Earth Systems |
5010 | 1-20 of 20 | 5010.pdf | Permanent Walls - T-Wall ( 3" Cover ) |
5011 | 1-21 of 21 | 5011.pdf | Permanent Walls - T-Wall ( 2" Cover ) |
5012 | 1-20 of 20 | 5012.pdf | Permanent Walls - Isogrid |
5015 | 1-14 of 14 | 5015.pdf | Permanent Walls - Reinforced Earth Wall |
5016 | 1-8 of 8 | 5016.pdf | Permanent Walls - Techwall |
5020 | - | - | Reserved |
5021 | 1-13 of 13 | 5021.pdf | Permanent Walls - Hilfiker Square Panel Wall |
5025 | 1-17 of 17 | 5025.pdf | Permanent Walls - MSE Retaining Wall |
5105 | 1-3 of 3 | 5105.pdf | Permanent Walls - Wire Face Wall |
5115 | 1-4 of 4 | 5115.pdf | Permanent Walls - Terratrel Wire Wall |
5120 | 1-4 of 4 | 5120.pdf | Permanent Walls - Hilfiker Welded Wire Wall |
5125 | 1-3 of 3 | 5125.pdf | Permanent Walls - Tensar Temporary Wall |
5130 | 1-4 of 4 | 5130.pdf | Permanent Walls - TC Mirafi Wire Form |
* SIGNING AND MARKINGS * | |||
9535 | 1-3 of 3 | 9535.pdf | Standard Roadside Sign Break-Away Post Details |
* SIGNS * | |||
11037 | 1 of 1 | 11037.pdf | Aluminum & Steel Overhead Sign Structures ( Details Of Sign Faces & Truss Connection ) |
11860 | 1-3 of 3 | 11860.pdf | Single Column Ground Signs ( Sign Profile & Identification Numbers ) |
11861 | 1-2 of 2 | 11861.pdf | Single Column Ground Signs ( 60 mph ) |
11862 | 1-2 of 2 | 11862.pdf | Single Column Ground Signs ( 70 mph ) |
11863 | 1-2 of 2 | 11863.pdf | Single Column Ground Signs ( 80 mph ) |
11864 | 1-2 of 2 | 11864.pdf | Single Column Ground Signs ( 90 mph ) |
11865 | 1-2 of 2 | 11865.pdf | Single Column Ground Signs ( All Wind Zones ) |
* EXIT NUMBERING SIGNS * | |||
13417 | 1 of 1 | 13417.pdf | Mounting Exit Numbering Panels To Highway Signs |
* SIGNING AND MARKINGS * | |||
17302 | 1 of 1 | 17302.pdf | Typical Sections For Placement Of Single & Multi-Column Signs |
17328 | 1 of 1 | 17328.pdf | Typical Signing For Truck Weigh & Inspection Stations |
17344 | 1-6 of 6 | 17344.pdf | School Signs & Markings |
17345 | 1-4 of 4 | 17345.pdf | Interchange Markings |
17346 | 1-13 of 13 | 17346.pdf | Special Marking Areas |
17349 | 1 of 1 | 17349.pdf | Traffic Controls For Street Terminations |
17350 | 1 of 1 | 17350.pdf | Signing For Motorist Services |
17351 | 1-2 of 2 | 17351.pdf | Welcome Center Signing |
17352. | 1-2 of 2 | 17352.pdf | Typical Placement Of Reflective Pavement Markers |
17355 | 1-14 of 14 | 17355.pdf | Special Sign Details |
17356 | 1-2 of 2 | 17356.pdf | Span Wire Mounted Sign Details |
17357 | 1 of 1 | 17357.pdf | Bridge Weight Restrictions |
17359 | 1 of 1 | 17359.pdf | Rural Narrow Bridge Treatment |
* ROADWAY LIGHTING * | |||
17500 | 1-3 of 3 | 17500.pdf | Conventional Lighting |
17501 | 1 of 1 | 17501.pdf | Highway Lighting General Notes |
17502 | 1-4 of 4 | 17502.pdf | Highmast Lighting Details |
17503 | 1 of 1 | 17503.pdf | Roadway Lighting Details |
17504 | 1 of 1 | 17504.pdf | Service Point Details |
17505 | 1-2 of 2 | 17505.pdf | External Lighting For Signs ( Mercury Vapor ) |
17515 | 1-7 of 7 | 17515.pdf | Aluminum Light Pole |
* TRAFFIC SIGNAL AND EQUIPMENT * | |||
17600 | 1-2 of 2 | 17600.pdf | Motorist Aid Call Box |
17721 | 1-2 of 2 | 17721.pdf | Conduit Installation Details |
17723 | 1-3 of 3 | 17723.pdf | Steel Strain Pole Elevation And Notes |
17725 | 1 of 1 | 17725.pdf | Concrete Poles |
17727 | 1-2 of 2 | 17727.pdf | Signal Cable And Span Wire Installation Details |
17733 | 1 of 1 | 17733.pdf | Aerial Interconnect |
17736 | 1 of 1 | 17736.pdf | Electric Power Service |
17740 | 1-2 of 2 | 17740.pdf | Instructions And Examples For Designer And Fabricators Of Standard Mast Arm Assemblies |
17742 | 1 of 1 | 17742.pdf | Component Data For Standard Mast Arm Assemblies |
17744 | 1-5 of 5 | 17744.pdf | Mast Arm Assemblies |
17746 | 1-4 of 4 | 17746.pdf | Monotube Signal Structure Elevation, Notes And Camber Details |
17748 | 1 of 1 | 17748.pdf | Free-Swinging, Internally-Illuminated Street Sign Assemblies |
17764 | 1 of 1 | 17764.pdf | Pedestrian Control Signal Installation Details |
17781 | 1-2 of 2 | 17781.pdf | Vehicle Loop Installation Details |
17784 | 1-2 of 2 | 17784.pdf | Pedestrian Detector Assembly Installation Details |
17841 | 1 of 1 | 17841.pdf | Cabinet Installation Details |
17870 | 1-2 of 2 | 17870.pdf | Standard Signal Operating Plans |
17881 | 1 of 1 | 17881.pdf | Advance Warning For R/R Crossing |
17882 | 1-4 of 4 | 17882.pdf | Railroad Grade Crossing Traffic Control Devices |
17890 | 1-3 of 3 | 17890.pdf | Traffic Control Devices For Movable Span Bridge Signals |
* MISCELLANEOUS * | |||
17900 | 1-9 of 9 | 17900.pdf | Traffic Monitoring Site |