4542 search results for fla

9900200-723origind2

sunlight with a minimum of onsite maintenance for Automated Flagger Assistance Devices signs. 2, be weather-tight. 2. Except for Automated Flagger Assistance Devices, the display assembly shall, be painted flat black and shall meet Federal Specification TT-E-489. 4. The display panel, speed display units. Automated Flagger Assistance Devices may be trailer or non-trailer units, substituted: 990-15 Flagger Equipment. 990-15.1 STOP/SLOW Paddles: Provide STOP/SLOW paddles

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/internal/9900200-723origind2.pdf?sfvrsn=cd5fc6cb_1

E51F9

 Florida Department of Transportation Bid Solicitation Notice and Approximate Quantities Letting: 05240402 Call Order:003 Proposal:E51F9 District:05 Counties: FLAGLER Road Name:SR A1A Limits: 73030000 Project(s):43912415201(*) Federal Aid No: N/A Total Roadway Length: Contract Days: 260, in Flagler County. PREQUALIFICATION REQUIRED Call Order: 003 Proposal: E51F9 ALT Item Description Unit, POLE, F&I, TYPE P-II SERVICE POLE EA 6.000 0654- 2- 18 MIDBLOCK CROSSWALK: REC RAPID FLASHING

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d5/lettings/2024/apr02/e51f9.pdf?sfvrsn=8f3974ae_1

2023 BOE Manual

Type flags in the BOE, allowing for easy identification of items that may require additional, includes valid (effective/obsolete) dates. A Spec flag is assigned to all pay items for non-standard work, , Trial Items 1000s Utilities 2.8.3 Specification Flags on Pay Items Several letters or “flags, The Spec-Type flags in the BOE are indications of the level of pay item support that were likely necessary, in the BOE, but the presence of a flag can still indicate that further due diligence may be required

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/fpo/fpc/publications/boe/2023-boe-manual.pdf?sfvrsn=3244e10b_1

2021_CTD_Annual_Performance_Report

in Flagler, Martin, St, Lucie, DeSoto/Hardee/Highlands/ Okeechobee, and Orange/Osceola/Seminole, and Santa Rosa counties. FlaglerFlagler Co BOCC$366,568.00Provided dialysis transportation Monday

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/ctd/docs/studies-reports/2021_ctd_annual_performance_report9de30096a77e4462a15bce3acd0d17c6.pdf?sfvrsn=f49d4432_2

9900200-723FHWA

maintenance for Automated Flagger Assistance Devices signs. 2. The battery shall be equipped, for Automated Flagger Assistance Devices, the display assembly shall be equipped with an automatic dimming, . The display panel background and frame for the display assembly shall be painted flat black and shall meet, mounted units are required for regulatory signs and radar speed display units. Automated Flagger, Eligibility Letters ARTICLE 990-15 is deleted and the following substituted: 990-15 Flagger Equipment

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/fhwa/9900200-723fhwa.pdf?sfvrsn=1c8d4d40_1

E53F4

 Florida Department of Transportation Bid Solicitation Notice and Approximate Quantities Letting: 05240904 Call Order:003 Proposal:E53F4 District:05 Counties: FLAGLER Road Name:SR A1A Limits, 8th St to N 18th St in Flagler County. PREQUALIFICATION REQUIRED Call Order: 003 Proposal: E53F4, CROSSWALK: RECTANGULAR RAPID FLASHING BEACON, FURNISH & INSTALL- AC, COMPLETE SIGN ASSEMBLY- BACK TO BACK AS 2.000 0654- 2- 60 MIDBLOCK CROSSWALK: RECTANGULAR RAPID FLASHING BEACON, REMOVE COMPLETE

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d5/lettings/2024/sep04/e53f4.pdf?sfvrsn=7f21f89d_1

441700-1.Cove Rd from SR-76_Kanner Hwy to SR-5_US-1 GeoReport

plains on marine terraces on flatwoods. The parent material 2 Geotechnical Services - PD&E TSFGeo, of the map unit. Slopes are 0 to 2 percent. This component is on flatwoods on marine terraces, percent. This component is on flatwoods on marine terraces on coastal plains. The parent material, . Slopes are 0 to 2 percent. This component is on flatwoods on marine terraces on coastal plains, . Excellent exposures occur in Flagler County in Washington Oaks State Park, in Martin County

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/cove-road-study/441700-1-cove-rd-from-sr-76_kanner-hwy-to-sr-5_us-1-georeport.pdf?sfvrsn=42e3d65b_1

SS4500000

forms designed to be removed without damaging the top flange of the beam. Remove the forms horizontally away from the beam by a method that prevents any contact of the form with the top flange after release of the form. Do not subject the top flange to any vertical force at any time. Include, the bottom of the flange. 450-10.3.2.2 AASHTO Type III and Type IV Beams and Voided Units (Slabs and Piling, will be such that the top of the concrete is just above the top of the bottom flange. In voided units, end

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2009/january-2009/workbook/ss4500000d6887b086ab44d6d9f958a35d885e6da.pdf?sfvrsn=43eac8f2_0

Chapter7s4Redline

Resource (FLAIR) “6”s” line by the requested amount and re-encumber on a new FLAIR “6”s” line, Management (CFM) system. (4) The FLAIR contract amendment file will be updated to indicate, is processed through FLAIR and then the Unilateral Payment can be executed. The funds for the Unilateral

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/manuals/cpam/newhistory/chapter7s4redline.pdf?sfvrsn=edc444e6_3

Chapter7s4

be in an executed status. (3) The DCE or designee will reduce the Florida Account Information Resource (FLAIR) “6s, Contingency Supplemental Agreements and 7-4-4 Work Orders a new FLAIR “6s” line with a Function Code/ Work, ) system. (4) The FLAIR contract amendment file will be updated to indicate the change. The funds, encumbrance request will be approved by the CFM system when the encumbrance is processed through FLAIR

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/manuals/cpam/newcleanchapters/chapter7s4.pdf?sfvrsn=1498bdfa_6

CPAM 7.4 Clean 2022-PrC

be in an executed status. (3) The DCE or designee will reduce the Florida Account Information Resource (FLAIR) “6s, Contingency Supplemental Agreements and 7-4-4 Work Orders a new FLAIR “6s” line with a Function Code/ Work, ) system. (4) The FLAIR contract amendment file will be updated to indicate the change. The funds, encumbrance request will be approved by the CFM system when the encumbrance is processed through FLAIR

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/manuals/cpam/newcleanchapters/cpam-7-4-clean-2022-prc.pdf?sfvrsn=661b3ce7_3

4500301-723FHWA

, the top flange dormant strands may be released after the concrete reaches a compressive strength of 2,000, in the bearing areas and edges of the top flange, a minor spall is defined as a spall not larger than 2.0, with 450-13.5. Spalls located at the edges of the top flange are considered minor spalls as follows: 1. A spall on one edge of the top flange, without a coincident spall on the other edge of the top flange, are not greater than 25% of the width of the top flange. 2. Coincident spalls on opposite edges

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/fhwa/4500301-723fhwa.pdf?sfvrsn=a0ed073d_1

4000404.origind

experience excessive web plate deformations, top and bottom flange lateral bending deformations, and out, than 6" above the bottom flange and/or the concrete deck overhang is 4 feet or greater, within 6 inches of the bottom flange. If the lower contact point of the overhang falsework bears more than 6 inches above the bottom flange and/or if the deck overhang is 4 feet or greater, submit

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2015/january-2015/review/internal/4000404.origind.pdf?sfvrsn=3722fee3_0

6410000.FHWA

a smooth finish free from cracks, blow-holes, shrinks, and other flaws. All roller fairlead frames, . The winch cabinet door must be double -flanged and include neoprene closed-cell gaskets permanently, . The winch cabinet door opening must be double flanged. The winch cabinet door must iInclude a pin, -holes, shrinks, and other flaws. All roller fairlead frames must be corrosion resistant stainless, -flanged and include neoprene closed-cell gaskets permanently secured on the interior door surfaces

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2015/january-2015/review/fhwa/6410000.fhwa.pdf?sfvrsn=eb168fac_0

8-Fall 2023 Construction Academy MOT Session

changes are performed with minimal disruption to work activities • A list of trained flaggers must, and removal of pavement markings • Crash reporting • Night work • Flaggers • Motorist Awareness, , flaggers, and other personnel responsible for work zone related transportation management, Department of Transportation Process Review Findings Low profile barrier did not have proper flare

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/training/2023-construction-academy/fall-2023/8-fall-2023-construction-academy-mot-session.pdf?sfvrsn=1d4f5d28_2

13-2024 Construction Academy MOT Session

to work activities • A list of trained flaggers must be submitted before construction begins, • Night work • Flaggers • Motorist Awareness System (MAS) • Work zone clearances • Inactive, of Traffic) Personnel: Worksite Traffic Supervisors, flaggers, and other personnel responsible, of Transportation Process Review Findings Low profile barrier did not have proper flare rate

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/training/2024-spring-construction-academy/13-2024-construction-academy-mot-session.pdf?sfvrsn=bb04613d_1

2025 Construction Academy MOT Session

with minimal disruption to work activities • A list of trained flaggers must be submitted before, • Crash reporting • Night work • Flaggers • Motorist Awareness System (MAS) • Work zone, Traffic Control (Maintenance of Traffic) Personnel: Worksite Traffic Supervisors, flaggers, and other, Process Review Findings Low profile barrier did not have proper flare rate on approach end. Index

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/training/2024-fall-construction-academy/2025-construction-academy-mot-session.pdf?sfvrsn=59567378_1

MOT Session- PDF

with minimal disruption to work activities • A list of trained flaggers must be submitted before, • Crash reporting • Night work • Flaggers • Motorist Awareness System (MAS) • Work zone, Traffic Control (Maintenance of Traffic) Personnel: Worksite Traffic Supervisors, flaggers, and other, Process Review Findings Low profile barrier did not have proper flare rate on approach end. Index

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/training/2025-spring-construction-academy/mot-session--pdf.pdf?sfvrsn=c2151e5_1

MOT Session

with minimal disruption to work activities • A list of trained flaggers must be submitted before, • Crash reporting • Night work • Flaggers • Motorist Awareness System (MAS) • Work zone, Traffic Control (Maintenance of Traffic) Personnel: Worksite Traffic Supervisors, flaggers, and other, Process Review Findings Low profile barrier did not have proper flare rate on approach end. Index

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/training/2025-fall-construction-academy/mot-session.pdf?sfvrsn=87d1d53a_1
20 of 4542 results