1780 search results for bridge inspection

Freshwater Mussel PA Update_Jan2024_ForPosting

.................................................................................. 18 Table 3: Bridge Construction: Component Activities, Effects, and Conservation, ....................................................................................................................................................... 19 Table 4: Bridge Repair, of these bridge structures are likely to require consultation under the Endangered Species Act of 1973, action types are: 1. Construction projects such as bridge construction, bridge removal, bridge restoration/rehabilitation/preservation, bridge scour protection, culvert construction, culvert extension

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/environment/pubs/protected-species/freshwater-mussel-pa-update_jan2024_forposting.pdf?sfvrsn=2293f53c_1

CPAM 3.1 REDLINE 2023_11-6-2024

acceptance inspection (14) Bridge Construction and/or Drilled Shafts [Discuss the following: (a) Level II, work and required TMS inspection per Specifications 695.] The TMS inspector must be onsite during equipment installation and will perform the final acceptance inspection. (a) For the Continuous, Office at 1-800-399-5523 a minimum of 30 days prior to final acceptance inspection iv. Final, at 1-800-399-5523 a minimum of 14 days prior to final acceptance inspection (b) For the Short-Term Monitoring

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/manuals/cpam/newhistory/cpam-3-1-redline-2023_11-6-2024.pdf?sfvrsn=35b17a01_2

Chapter3s1Redline

acceptance inspection (14) Bridge Construction and/or Drilled Shafts [Discuss the following: (a) Level, work and required TMS inspection per Specifications 695.] The TMS inspector must be onsite during equipment installation and will perform the final acceptance inspection. (a) For the Continuous, and Analytics Office at 1-800-399-5523 a minimum of 30 days prior to final acceptance inspection iv. Final, at 1-800-399-5523 a minimum of 14 days prior to final acceptance inspection (b) For the Short-Term

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/manuals/cpam/newhistory/chapter3s1redline.pdf?sfvrsn=1abc37be_10

Chapter3s1

Coordinator a minimum of 14 days prior to final acceptance inspection (14) Bridge Construction, (TMS) [Discuss required notification prior to beginning work and required TMS inspection per, the final acceptance inspection. (a) For the Continuous Count Stations (CCS), previously known as TTMS, days prior to final acceptance inspection iv. Final Acceptance for non-WIM Equipment Installation, acceptance inspection (b) For the Short-Term Monitoring Site (STMS), previously known as PTMS

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/manuals/cpam/newcleanchapters/chapter3s1.pdf?sfvrsn=c4289fff_22

E1W47Addendum001

: ........................................................................................ 44 U. Construction Engineering and Inspection, DOCUMENTS EA01_Original Bridge Asbuilts I-75 at SR 780 EA02_4206132_STRUCTURES_Concept Plans, , details, and construction techniques for bridge structures as discussed in Part 1, Chapter 121

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d1/designbuild/e1w47/e1w47addendum001.pdf?sfvrsn=e5c8b0b0_1

PMG PDF V11

inspection and related support phases (PE & design are excluded). LOCAL AGENCY PROGRAM AGREEMENTS, and Inspection (CEI) contracts are executed. Following notification that federal project authorization has

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/designsupport/pmresources/pmg-pdf-v11.pdf?sfvrsn=3e22758b_1

SCO Boilerplate RFP (Standard D-B) CLEAN version 2023-01d updates 3-13-2024

of Values: 40 T. Computer Automation: 41 U. Construction Engineering and Inspection: 42 V. Testing: 42 W, to developer of the RFP: If a bridge will be widened as a part of the project, then an Attachment should be developed that includes a signed and sealed Load Rating that proves the bridge, of the RFP: When Geotechnical Services are part of Project scope) Value Added Bridge Component (DEV475, ratings and inspection reports Survey & SUE Geotechnical Report – Signed and sealed Geotechnical Data

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/designbuild/dbdocuments/rfpdocs/sco-boilerplate-rfp-(standard-d-b)-clean-version-2023-01d-updates-3-13-2024.docx?sfvrsn=d0d70f90_3

4500000.origind

. 450-2.56 Quality Assurance Inspection and Testing: The Engineer will perform periodic inspections, for performing daily Quality Control (QC) inspections of all phases of work ensuring all materials, of the QC inspections. Ensure a QC inspector is present during concrete placements and performs inspection during all fabrication of precast prestressed concrete products, including the inspection, . Ensure the QC inspector is present during concrete placements and performs inspection during all

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2019/january-2019/review/internal/4500000.origind.pdf?sfvrsn=919064ed_0

Pt2Ch3_073124_clean

Bridge Maintenance Office maintains Bridge Inspection Reports (BIRs) for every public bridge, ............................................................. 3-32 3.2.5.20.1 Development of Bridge Alternatives, 3.2.5.20.3 Bridge Hydraulics .............................................................. 3-33, on completing PD&E and Design phases concurrently. Bridge replacement PD&E Studies do not require, be documented in the Bridge Development Report (BDR) or Bridge Replacement Report (BRR) . Topic

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/environment/pubs/pdeman/2024/pt2ch3_073124_clean.pdf?sfvrsn=83170cf0_1

E1W47Addendum010

bridge geometry to be input by the Engineer. Other parameters such as water traffic, waterway, on the same assumptions other than the specific bridge layout that each is proposing. e, : . . . . . . .................................................................................. 4 4 U. Construction Engineering and Inspection, (375-030-60 & 275-030-11, 11B) EXEMPT ATTACHMENT DOCUMENTS EA01_Original Bridge Asbuilts I-75 at SR, design concepts, components, details, and construction techniques for bridge structures as discussed

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d1/designbuild/e1w47/e1w47addendum010.pdf?sfvrsn=fbed3cdb_1

E4W70

(*) Federal Aid No: N/A Total Roadway Length: 2.489 Miles Contract Days: 206 Total Bridge Length: 0.000, ), erosion control (sediment barrier), monitor existing structures (inspection, settlement, for this project. PLEASE READ STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION FY2023-24 (SECTION 7-13, - LITTER REMOVAL AC 66.260 0107- 2- MOWING AC 56.500 0108- 1- MONITOR EXISTING STRUCTURES- INSPECTION

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d4/lettings/2024/feb04/e4w70.pdf?sfvrsn=cd583da8_1

E4W89

(*) Federal Aid No: N/A Total Roadway Length: 3.076 Miles Contract Days: 180 Total Bridge Length: 0.000, (inspection, settlement, vibration), inlet protection, clearing and grubbing (standard, selective), concrete, SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION FY 2024-25 (SECTION 7-13) FOR INSURANCE LIMITS AWARD, EXISTING STRUCTURES- INSPECTION AND SETTLEMENT MONITORING (44767415201) LS 1.000 0108- 2- MONITOR

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d4/lettings/2024/jul12/e4w89.pdf?sfvrsn=ce101a3a_1

E4W95

Contract Days: 305 Total Bridge Length: 0.000 Miles Letting Date: 08/02/24 Total Proposal Length: 2.532, (inspection, settlement), utilities adjustment (manhole, valve box), and sod along State Road 794, STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION FY2024-25 (SECTION 7-13) FOR INSURANCE, - MOWING AC 1.540 0108- 1- MONITOR EXISTING STRUCTURES- INSPECTION AND SETTLEMENT MONITORING

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d4/lettings/2024/aug02/e4w95.pdf?sfvrsn=1ad05383_1

E4X51

No: N/A Total Roadway Length: 6.822 Miles Contract Days: 252 Total Bridge Length: 0.000 Miles Letting, , loop detection, pedestrian detection, pedestal), monitor structures (inspection, settlement, AND BRIDGE CONSTRUCTION FY2024-25 (SECTION 7-13) FOR INSURANCE LIMITS. Award of this contract is contingent, - MONITOR EXISTING STRUCTURES- INSPECTION AND SETTLEMENT MONITORING (44765815201) LS 1.000 0108- 2

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d4/lettings/2024/aug02/e4x51.pdf?sfvrsn=2f189f3c_1

E4X39

(*) Federal Aid No: N/A Total Roadway Length: 1.981 Miles Contract Days: 170 Total Bridge Length: 0.000, , signalization, maintenance), structures monitoring (inspection, settlement), concrete (removal, curb, SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION FY2024-25 (SECTION 7-13) FOR INSURANCE LIMITS. Call Order, Quantity 0108- 1- MONITOR EXISTING STRUCTURES- INSPECTION AND SETTLEMENT MONITORING (44768115201) LS

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d4/lettings/2024/sep06/e4x39.pdf?sfvrsn=fcc6e405_1

E4X31

No: N/A Total Roadway Length: 7.611 Miles Contract Days: 335 Total Bridge Length: 0.000 Miles Letting, of existing structures (inspection and settlement, vibration), utility adjustments (manhole, for this project. PLEASE READ STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION FY2024-25 (SECTION, 284.270 0107- 2- MOWING AC 177.670 0108- 1- MONITOR EXISTING STRUCTURES- INSPECTION AND SETTLEMENT

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d4/lettings/2024/oct04/e4x31.pdf?sfvrsn=48f1f35b_1

E8V92

Aid No: N/A Total Roadway Length: 1.058 Miles Contract Days: 310 Total Bridge Length: 0.000 Miles, the southern end bent spill slope under existing Bridge No. 750285 and a new actuated signal, 19.390 0107- 2- MOWING AC 15.440 0108- 1- MONITOR EXISTING STRUCTURES- INSPECTION AND SETTLEMENT, 0440- 70- UNDERDRAIN INSPECTION BOX EA 16.000 0440- 73- 2 UNDERDRAIN OUTLET PIPE, 6" LF 183.000

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/tp/lettings/2025/may06/e8v92.pdf?sfvrsn=a8b5d3b2_1

3340501FHWA

on the basis of visual inspection. The Engineer may require the Contractor to run process control, placed on bridge decks or approach slabs; compact these courses in static mode only per, , the Engineer will accept the mix on the basis of visual inspection. The Engineer may require, will not be performed on asphalt courses placed on bridge decks or approach slabs; compact these courses

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2025-26/review/fhwa/3340501fhwa.pdf?sfvrsn=b3f28284_1

9600100-722impl

for compliance with AASHTO LRFD Bridge Design Specifications and AASHTO LRFD Bridge Construction, , high point inspection port details, anchorage inspection details, permanent anchorage caps

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/implemented/9600100-722impl.pdf?sfvrsn=4961e39f_2

PMG PDF V9

inspection and related support phases (PE & design are excluded). LOCAL AGENCY PROGRAM AGREEMENTS, and Inspection (CEI) contracts are executed. Following notification that federal project authorization has

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/designsupport/pmresources/pmg-pdf-v9.pdf?sfvrsn=a503f353_1
20 of 1780 results