9037 search results for test

5201000-722resp

 5201000 CONCRETE GUTTER, CURB ELEMENTS, AND TRAFFIC SEPARATORS COMMENTS FROM INTERNAL/INDUSTRY REVIEW Deborah Ihsan (954) 777-4387 deborah.ihsan@dot.state.fl.us Comments: (1-18-22, Industry) Concrete Gutter, Curb Elements, and Traffic Separators: The draft proposes to delete section 520-10 and introduced the following. “520-10 Surface Requirements. 520-10.1 Straightedge: Test the gutter section of curb and gutter with a 10 foot straightedge laid parallel to the centerline

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/comments-responses/5201000-722resp.pdf?sfvrsn=af80534f_2

5201000-722comm

 5201000 CONCRETE GUTTER, CURB ELEMENTS, AND TRAFFIC SEPARATORS COMMENTS FROM INTERNAL/INDUSTRY REVIEW Deborah Ihsan (954) 777-4387 deborah.ihsan@dot.state.fl.us Comments: (1-18-22, Industry) Concrete Gutter, Curb Elements, and Traffic Separators: The draft proposes to delete section 520-10 and introduced the following. “520-10 Surface Requirements. 520-10.1 Straightedge: Test the gutter section of curb and gutter with a 10 foot straightedge laid parallel to the centerline

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/comments-responses/5201000-722comm.pdf?sfvrsn=f423a0c9_2

6460200.FHWA

laboratory test report, and calculations and drawings showing details, notes, materials, dimensions, test reports from the manufacturer verifying that each base model meets the moment capacity without, submit an application in accordance with Section 6, independent laboratory test report, capacity of 10,000 foot-pounds. Submit certified test reports from the manufacturer verifying that each

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2017/july-2017/review/fhwa/6460200.fhwa.pdf?sfvrsn=41c4c8f5_0

5360000.FHWA

and dimensions identified suitable for posting on the APL, independent test reports that indicate the product meets all crash test requirements of National Cooperative Highway Research Program (NCHRP-350, test reports that indicate the composite material meets all the following physical requirements: Composite Block Test Method Requirement Durometer Hardness ASTM D2240 Shore D Minimum 50 Durometer

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2017/july-2017/review/fhwa/5360000.fhwa.pdf?sfvrsn=876957e1_0

5360000.origind

, with the product name and dimensions identified suitable for posting on the APL, independent test reports that indicate the product meets all crash test requirements of National Cooperative Highway, directives and independent test reports that indicate the composite material meets all the following physical requirements: Composite Block Test Method Requirement Durometer Hardness ASTM D2240

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2017/january-2017/review/internal/5360000.origind.pdf?sfvrsn=a312f1b4_0

6460202.FHWA

submit an application in accordance with Section 6, independent laboratory test report, an ultimate moment capacity of 10,000 foot-pounds. SubmitProvide certified test reports from, ). ManufacturersseekingAPLapprovalofproprietarytransformerbasesmust submit an application in accordance with Section 6, independent laboratory test report, an ultimate moment capacity of 10,000 foot-pounds. Submit certified test reports from the manufacturer

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/july-2016/review/fhwa/6460202.fhwa.pdf?sfvrsn=42af8186_0

5710300.impl

 571 PLASTICEROSIONMAT. (REV10-26-15)(FA1-11-16)(7-16) ARTICLE571-3isdeletedandthefollowingsubstituted: 571-3InstallationofPlasticErosionMat. Before installing the plastic erosion mat, submit to the Engineer certified test reports from the manufacturer certifying that the geotextile to be incorporated into this project meets the requirements of Section 985. Also, submit the manufacturer’s written installation instructions. Installaplasticerosionmat of uniform thickness, not less than

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/july-2016/review/implemented/5710300.impl.pdf?sfvrsn=9fa7b681_0

9730000.origind

(RTSS) and Thermoplastic Structural Shapes (TSS), respectively; test criteria for RTSS and TSS, and include independently certified test reports, and manufacturer’s certification that the material, by a tension test in accordance with ASTM D2343. 973-4.1.2 Resin: Use a commercial grade thermoset, Required Physical Properties - VIP FRP Physical Property Requirement Test Method Barcol Hardness > 40

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2015/january-2015/review/internal/9730000.origind.pdf?sfvrsn=517d21e3_0

9140000.impl

(with the exception of gradation analysis) in lieu of FM 1-T267 after mixing. The maximum allowable test result

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/july-2014/review/implemented/9140000.impl.pdf?sfvrsn=af08cdd1_0

3340504 IndustryCommentResponse

 Specification Section 334 Subarticle 334-5 ORIGINATION Date: 3-18-25 Name: Greg Sholar Email: gregory.sholar@dot.state.fl.us COMMENTARY One change is related to a safety enhancement and the other change is related to avoiding project delays when evaluating pavement material that had failing test results. INDUSTRY COMMENTS AND RESPONSES (Please note all comments and responses are verbatim as received. The Specifications Office does not alter typos or grammar.) BLACK = Comment

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2026-27/review/industry/comments-responses/3340504-industrycommentresponse.pdf?sfvrsn=bc1a4444_1
20 of 9037 results