2,500 psi. Determine concrete strength from tests on a minimum of two test cylinders, tested, will allow a cast base, provided the Contractor submits test reports giving evidence that the base, tests and submit certified reports for one base to be used with each pole size. Use Alloy A 356-T6

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul07/files/7000000.impl.pdf?sfvrsn=2f0b1c60_0

SS7000000

from tests on a minimum of two test cylinders, tested in accordance with Section 346, submits test reports giving evidence that the base to be used for each pole size is as strong as the pole with which it is to be used. Perform physical tests and submit certified reports for one base

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2008/files/ss7000000.pdf?sfvrsn=2be312fd_0

SS7000000

strength is at least 2,500 psi. Determine concrete strength from tests on a minimum of two test cylinders, tested in accordance with Section 346. Erectthesigns and sign structures in accordance, the Engineer will allow a cast base, provided the Contractor submits test reports giving evidence, physical tests and submit certified reports for one base to be used with each pole size. Use Alloy

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2009/january-2009/workbook/ss7000000.pdf?sfvrsn=5cd6a3c9_0

4500000.origind

keeping the deficiencies found as a result of the inspection and testing. Keep certified test, and the Department’s verification tests. The sampling for verification testing will be performed, ) activities including the verification and Independent Assurance inspection and testing are performed, regarding the certification and/or testing of prestressing steel, reinforcing steel, concrete materials, time for the Engineer’s inspection. 450-2.5 Quality Assurance Inspection and Testing

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul08/files/4500000.origind.pdf?sfvrsn=55bb903f_0

6490000-2.FHWA

strength and verifying test results have been provided to the Engineer. Determine concrete strength from tests on a minimum of two test cylinders prepared and tested in accordance with ASTM C31, and verifying test results have been provided to the Engineer. Determine concrete strength from tests on a minimum of two test cylinders prepared and tested in accordance with ASTM C31 and ASTM C39. Before

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2015/january-2015/review/fhwa/6490000-2.fhwa.pdf?sfvrsn=cd91b0e2_0

STN Maintainer

. By conducting the training in this manner, students will each have the confidence and well-tested

https://www.fdot.gov/contracts/district-offices/d5/lettings/dist-letting-project-info.shtm/lists/train-curriculum/stn-maintainer

ITS Maintainer

the confidence and well-tested capability to utilize the ITSFM to full capacity immediately after

https://www.fdot.gov/contracts/district-offices/d5/lettings/dist-letting-project-info.shtm/lists/train-curriculum/its-maintainer

D0060067

 006 CONTROLOFMATERIALS. (REV9-4-01)(FA1-3-02)(7-02) ARTICLE6-7(Page54)isdeletedandthefollowingsubstituted: 6-7Defective Materials. TheDepartment will consider the following materials as defective: all materials not meeting the requirements of these Specifications; segregated materials, even though previously tested and approved; materials that are or have been improperly stored; and materials that are mixed with an excess of clay, coal, sticks, burlap, hay, straw, loam or earth

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2002/files/d0060067.pdf?sfvrsn=311d07f8_0

D0060067

 006 CONTROLOFMATERIALS. (REV9-4-01)(FA1-3-02)(7-02) ARTICLE6-7(Page54)isdeletedandthefollowingsubstituted: 6-7Defective Materials. TheDepartment will consider the following materials as defective: all materials not meeting the requirements of these Specifications; segregated materials, even though previously tested and approved; materials that are or have been improperly stored; and materials that are mixed with an excess of clay, coal, sticks, burlap, hay, straw, loam or earth

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2002/files/d0060067275e4e0f7fee483f93fca7a1e87114f6.pdf?sfvrsn=26a6b03c_0

SPI-515-070

 Standard Plans Instructions Topic No. 625-010-003 Index 515-070 Aluminum Pipe Guiderail FY 2019-20 1 Index 515-070 Aluminum Pipe Guiderail Design Criteria Americans with Disabilities Accessibility Guidelines (ADAAG), 2004 as adopted with amendments by the USDOT under 49 CFR Part 37 Transportation for Individuals with Disabilities, Adoption of New Accessibility Standards Design Assumptions and Limitations The Aluminum Pipe Guiderail, Index 515-070 was tested by the FDOT Structural

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2020/spi/spi-515-070.pdf?sfvrsn=e59b3839_2

SPI-700-010

 Standard Plans Instructions Topic No. 625-010-003 Index 700-010 Single Column Ground Signs FY 2018-19 1 Index 700-010 Single Column Ground Signs Design Criteria AASHTO LRFD Specifications for Structural Supports for Highway Signs, Luminaires and Traffic Signals (LRFDLTS-1) ; Structures Manual (SM) , Volume 3, FDOT Modifications to LRFDLTS-1; Structures Manual (SM) Introduction, I.6 References; FDOT Design Manual (FDM) Both fabricated and cast base assemblies were impact tested

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2019/spi/spi-700-010.pdf?sfvrsn=fc1cf9e4_6

SPI-515-070

 Standard Plans Instructions Topic No. 625-010-003 Index 515-070 Aluminum Pipe Guiderail FY 2018-19 1 Index 515-070 Aluminum Pipe Guiderail Design Criteria Americans with Disabilities Accessibility Guidelines (ADAAG), 2004 as adopted with amendments by the USDOT under 49 CFR Part 37 Transportation for Individuals with Disabilities, Adoption of New Accessibility Standards Design Assumptions and Limitations The Aluminum Pipe Guiderail, Index 515-070 was tested by the FDOT

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2019/spi/spi-515-070.pdf?sfvrsn=1a53e844_6

SPI-700-120

 Standard Plans Instructions Topic No. 625-010-003 Index 700-120 Enhanced Highway Signing Assembly FY 2019-20 1 Index 700-120Enhanced Highway Signing Assembly Design Criteria FDOT Design Manual (FDM) Design Assumptions and Limitations The designs shown in Index 700-120 are based on systems crash tested for compliance with the AASHTO Manual for Assessing Safety Hardware (MASH). Modifications to these designs may significantly affect the crashworthiness of the system and should

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2020/spi/spi-700-120.pdf?sfvrsn=377960a4_2

SPI-700-010

 Standard Plans Instructions Topic No. 625-010-003 Index 700-010 Single Column Ground Signs FY 2019-20 1 Index 700-010Single Column Ground Signs Design Criteria AASHTO LRFD Specifications for Structural Supports for Highway Signs, Luminaires and Traffic Signals (LRFDLTS-1); Structures Manual (SM), Volume 3, FDOT Modifications to LRFDLTS-1; Structures Manual (SM) Introduction, I.6 References; FDOT Design Manual (FDM) Both fabricated and cast base assemblies were impact tested

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2020/spi/spi-700-010.pdf?sfvrsn=dcaf0c63_2
20 of 9274 results
Top