9204 search results for test

9700133 Respon

adhesive. We have a test project on I-75 where we used this material for a new type of marker. We, conditional warranty on the QPL test deck that we will evaluate under the new specification. Also, ) on the test deckare between the 6 month a 12 month evaluation period. We should know by the 12

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan07/files/9700133-respon.pdf?sfvrsn=495448a0_0

9820000SS

Certification. TheContractorshallprovide the Engineer a certified test report from the manufacturer of the commercial fertilizer confirming that the requirements of this Section are met. The certified test report shall conform to the requirements of Section 6 and include test results for total nitrogen

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/programmanagement/implemented/workbooks/julworkbook2006/files/9820000ss.pdf?sfvrsn=7e4a00e1_0

SPI-455-154

the required number of piles, piers and/or bents and use of Test Piles. When not enough space, . For projects without Test Piles change column heading "TEST PILE LENGTH (ft.)" to "PILE ORDER LENGTH (ft

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2020/spi/spi-455-154.pdf?sfvrsn=b0d24625_2

spi-455-054

as required to accommodate the required number of piles, piers and/or bents and use of Test Piles. When, of Data Tables. For projects without Test Piles change column heading "TEST PILE LENGTH (ft

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2019/spi/spi-455-054.pdf?sfvrsn=bd5185e4_6

spi-455-160

and/or bents and use of Test Piles. When not enough space is available on one plan sheet, continuations, I.3 for more information regarding use of Data Tables. For projects without Test Piles change column heading "TEST PILE LENGTH (ft.)" to "PILE ORDER LENGTH (ft.)". Standard Plans Instructions Topic

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2019/spi/spi-455-160.pdf?sfvrsn=fbcb8bac_6

SPI-455-054

as required to accommodate the required number of piles, piers and/or bents and use of Test Piles. When, of Data Tables. For projects without Test Piles change column heading "TEST PILE LENGTH (ft

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2020/spi/spi-455-054.pdf?sfvrsn=9a5897b5_2

SPI-455-060

the required number of piles, piers and/or bents and use of Test Piles. When not enough space is available, . For projects without Test Piles change column heading "TEST PILE LENGTH (ft.)" to "PILE ORDER LENGTH (ft

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2020/spi/spi-455-060.pdf?sfvrsn=a6b8d594_6

spi-455-154

the required number of piles, piers and/or bents and use of Test Piles. When not enough space, . For projects without Test Piles change column heading "TEST PILE LENGTH (ft.)" to "PILE ORDER LENGTH (ft

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2019/spi/spi-455-154.pdf?sfvrsn=2fc10afc_6

spi-455-060

the required number of piles, piers and/or bents and use of Test Piles. When not enough space is available, . For projects without Test Piles change column heading "TEST PILE LENGTH (ft.)" to "PILE ORDER LENGTH (ft

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2019/spi/spi-455-060.pdf?sfvrsn=c29f7eda_8

SPI-455-160

and/or bents and use of Test Piles. When not enough space is available on one plan sheet, continuations, I.3 for more information regarding use of Data Tables. For projects without Test Piles change column heading "TEST PILE LENGTH (ft.)" to "PILE ORDER LENGTH (ft.)". Standard Plans Instructions Topic

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2020/spi/spi-455-160.pdf?sfvrsn=e3e5f710_2

7100403-722impl

to test the markings within three days of receipt of the Contractor’s certification. Failure to afford the Department opportunity to test the markings will result in non-payment. The test readings

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/implemented/7100403-722impl.pdf?sfvrsn=da52418a_2

9820200-723origind

. The Contractor shall submit to the Engineer shall collect a certified test report from, of the fertilizer label and retain according to the FDOT retention policy. The certified test reportlabel shall conform to the requirements of Section 6 and include test results for totalinclude

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/internal/9820200-723origind.pdf?sfvrsn=e81d441c_1

Highway Lighting Inventory

, then the statewide smart forms must be used. News and Updates May 18, 2020 – Soft Implementation (UNIT Test)June 1, 2020 – Hard Implementation (SYSTEM Test)July 1 – August 30 – District Data Merges (SYSTEM Test

https://www.fdot.gov/maintenance/e-maint/default.shtm/highway-lighting-inventory

SPI-455-060

the required number of piles, piers and/or bents and use of Test Piles. When not enough space is available, Test Piles change column heading "TEST PILE LENGTH (ft.)" to "PILE ORDER LENGTH (ft.)". Standard

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2027/spi/spi-455-060.pdf?sfvrsn=71ad610a_1

SPI-455-160

and/or bents and use of Test Piles. When not enough space is available on one plan sheet, continuations, for more information regarding use of Data Tables. For projects without Test Piles change column heading "TEST PILE LENGTH (ft.)" to "PILE ORDER LENGTH (ft.)". Standard Plans Instructions Topic

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2027/spi/spi-455-160.pdf?sfvrsn=7039a4da_1

SPI-455-154

the required number of piles, piers and/or bents and use of Test Piles. When not enough space is available, Test Piles change column heading "TEST PILE LENGTH (ft.)" to "PILE ORDER LENGTH (ft.)". Standard

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2027/spi/spi-455-154.pdf?sfvrsn=3f514232_1

SPI-455-054

as required to accommodate the required number of piles, piers and/or bents and use of Test Piles. When, Tables. For projects without Test Piles change column heading "TEST PILE LENGTH (ft.)" to "PILE ORDER

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2027/spi/spi-455-054.pdf?sfvrsn=543d2130_1

4550518DB.FHWA

to Pile Verification Testing. A separate Foundation Certification Package must be submitted, legible copies of all pile driving logs, EDC records, all supplemental dynamic testing raw data and analyses for the foundation unit. The certification shall not be contingent on any future testing, to pile cap in the Foundation Certification Package. The results of dynamic testing, foundations to the Engineer prior to Pile Verification Testing. A separate Foundation Certification

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/july-2014/review/fhwa/4550518db.fhwa.pdf?sfvrsn=409cc63f_0

9900000.fhwa

have a minimum tensile strength of 40 psi when tested according to ASTM D 638. A rectangular test specimen 6 by 1 by 0.05 inch minimum thickness shall be tested at a temperature range of 40 to 80ºF, strength of 40 psi when tested according to ASTM D 638. A rectangular test specimen 6 by 1 by 0.05 inch, :Thesurfaceofthestripesandmarkings shall provide a minimum skid resistance value of 35 BPN (British Pendulum Number) when tested, markings shall have a minimum elongation of 25% when tested in accordance with ASTM D 638

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan09/files/9900000.fhwa.pdf?sfvrsn=99762be9_0

1050803.impl

the personnel performing plastic property tests have ACI Concrete Field Testing Technician-Grade I, all asphalt plant related testing with a CTQP Asphalt Plant Level I Technician. As an exception, , and perform all testing with a CTQP Asphalt Paving Level I Technician. As an exception, measurements, . 105-8.5.4 Documentation: Document all QC procedures, inspection, and all test results and make them, : 105-8.6.1ConcreteFieldTechnician - Level I: Ensure technicians performing plastic property testing on concrete

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/january-2016/review/implemented/1050803.impl.pdf?sfvrsn=75ced676_0
20 of 9204 results