666 search results for item average unit cost
1-20 eBook_SS_DS
with established procedures, and as approved by the Federal Highway Administration. This item has been, of a redesign or Cost Savings Initiative Proposal, or for repair designs and details of the permanent, or Cost Savings Initiative Proposal designs of items fully detailed in the Plans. Controlling Work Items. The activity or work item on the critical path having the least amount of total float. The controlling item of work will also be referred to as a Critical Activity. Culverts. Any structure
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2020/january-2020/ebook/1-20-ebook_ss_ds.pdf?sfvrsn=3900126a_1719eBook_SS_DLH
procedures, and as approved by the Federal Highway Administration. This item has been digitally, of a redesign or Cost Savings Initiative Proposal, or for repair designs and details of the permanent work, Website. Department-approved Specialty Engineers will not be authorized to perform redesigns or Cost, . The activity or work item on the critical path having the least amount of total float. The controlling item of work will also be referred to as a Critical Activity. Culverts. Any structure
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2019/july-2019/ebook/719ebook_ss_dlh.pdf?sfvrsn=76a63a43_2719eBook
procedures, and as approved by the Federal Highway Administration. This item has been digitally, of a redesign or Cost Savings Initiative Proposal, or for repair designs and details of the permanent work, Website. Department-approved Specialty Engineers will not be authorized to perform redesigns or Cost, . The activity or work item on the critical path having the least amount of total float. The controlling item of work will also be referred to as a Critical Activity. Culverts. Any structure
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2019/july-2019/ebook/719ebook.pdf?sfvrsn=bf366a48_2719eBook_SS_DLH
procedures, and as approved by the Federal Highway Administration. This item has been digitally, of a redesign or Cost Savings Initiative Proposal, or for repair designs and details of the permanent work, Website. Department-approved Specialty Engineers will not be authorized to perform redesigns or Cost, . The activity or work item on the critical path having the least amount of total float. The controlling item of work will also be referred to as a Critical Activity. Culverts. Any structure
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2019/july-2019/ebook/719ebook_ss_dlh.pdf?sfvrsn=b8d433d3_1119eBook
with established procedures, and as approved by the Federal Highway Administration. This item has been, structure as part of a redesign or Cost Savings Initiative Proposal, or for repair designs and details, to perform redesigns or Cost Savings Initiative Proposal designs of items fully detailed in the Plans. Controlling Work Items. The activity or work item on the critical path having the least amount of total float. The controlling item of work will also be referred to as a Critical Activity. Culverts
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2019/january-2019/ebook/119ebook.pdf?sfvrsn=abd5f2d5_6119eBook_SS_DLH
with established procedures, and as approved by the Federal Highway Administration. This item has been, structure as part of a redesign or Cost Savings Initiative Proposal, or for repair designs and details, to perform redesigns or Cost Savings Initiative Proposal designs of items fully detailed in the Plans. Controlling Work Items. The activity or work item on the critical path having the least amount of total float. The controlling item of work will also be referred to as a Critical Activity. Culverts
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2019/january-2019/ebook/119ebook_ss_dlh.pdf?sfvrsn=9d1a277_0119eBook_SS_DLH
with established procedures, and as approved by the Federal Highway Administration. This item has been, structure as part of a redesign or Cost Savings Initiative Proposal, or for repair designs and details, to perform redesigns or Cost Savings Initiative Proposal designs of items fully detailed in the Plans. Controlling Work Items. The activity or work item on the critical path having the least amount of total float. The controlling item of work will also be referred to as a Critical Activity. Culverts
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2019/january-2019/ebook/119ebook_ss_dlh.pdf?sfvrsn=22b33813_14550000DB.FHWA
from the scale. Use the scale readings as a check on an average of the dial readings. When measuring, as measured by the average of the dial gauge readings, from wireline readings and from level readings, /fill material down to the natural ground surface at no additional cost to the Department. When, , and control unit that allows the operator to read and adjust the hammer energy or equivalent ram, at no additional cost to the Department. 455-5.10.2 Provisions for Use of Preformed Pile Holes: Preformed pile
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/july-2018/review/fhwa/4550000db.fhwa.pdf?sfvrsn=5377f6e1_0SP7410000
. UseaVehicleSensorcurrentlylistedontheDepartment’s Approved Products List (APL) and compatible with the electronic unit to which, to 165ºF Output Signal 250 mV for 400 pound wheel load at 70ºF Minimum 1 volt signal for average, which fails the test at no additional cost to the Department. Recordrepresentativewaveforms for a passenger car, single unit truck, and a tractor/semi-trailer combination vehicle, for each, in the Contract Documents, plus all shipping and handling costs involved in the delivery
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2007/january-2007/workbook/sp7410000.pdf?sfvrsn=5d651d57_0SP7410000
. UseaVehicleSensorcurrentlylistedontheDepartment’s Approved Products List (APL) and compatible with the electronic unit to which, to 165ºF Output Signal 250 mV for 400 pound wheel load at 70ºF Minimum 1 volt signal for average, which fails the test at no additional cost to the Department. Recordrepresentativewaveforms for a passenger car, single unit truck, and a tractor/semi-trailer combination vehicle, for each, in the Contract Documents, plus all shipping and handling costs involved in the delivery
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2008/january-2008/workbook/sp7410000.pdf?sfvrsn=50cfd323_0SP7410000
. UseaVehicleSensorcurrentlylistedontheDepartment’s Approved Products List (APL) and compatible with the electronic unit to which, OutputSignal 250mV for 400 pound wheel load at 70ºF Minimum 1 volt signal for average passenger, site cabinet. Remove and replace any sensor which fails the test at no additional cost to the Department. Recordrepresentativewaveforms for a passenger car, single unit truck, and a tractor/semi, and handling costs involved in the delivery as specified in the Contract Documents. 741-6.4 I n s t a l
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2009/january-2009/workbook/sp7410000.pdf?sfvrsn=841eaa03_0SP7410000
. UseaVehicleSensorcurrentlylistedontheDepartment’s Approved Products List (APL) and compatible with the electronic unit to which, OutputSignal 250mV for 400 pound wheel load at 70ºF Minimum 1 volt signal for average passenger, site cabinet. Remove and replace any sensor which fails the test at no additional cost to the Department. Recordrepresentativewaveforms for a passenger car, single unit truck, and a tractor/semi, and handling costs involved in the delivery as specified in the Contract Documents. 741-6.4 I n s t a l
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2010/january-2010/workbook/sp7410000.pdf?sfvrsn=f95575bd_06330201-724FHWA
allowable attenuation at no cost to the Department. 633-3.1.8.1.1 OTDR Tracing: Test all fibers, a maximum bidirectional average of 0.1 decibel per splice when measured using an OTDR. Repair or replace splices that exceed allowable attenuation at no cost to the Department. 633-3.1.8.1.3 Connector, exceeding allowable attenuation at no cost to the Department. SUBARTICLE 633-3.2 is deleted, , for defective parts and equipment during the warranty period at no cost to the Department
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/fhwa/6330201-724fhwa.pdf?sfvrsn=4f1ec305_14550300.FHWA
to the natural ground surface at no additional cost to the Department. When using low displacement, read out, and control unit that allows the operator to read and adjust the hammer energy, penetration, the Department will pay the costs for such removal as Unforeseeable Work. 455-5.10 Preformed, blows after filling all of the voids between the pile and soil with sand at no additional cost, in the Plans, include the cost in the price for piles. In the event that the Engineer determines
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/january-2018/review/fhwa/4550300.fhwa.pdf?sfvrsn=47362d2e_06820000.origind
in an increase or decrease in project costs? If yes, what is the estimated change in costs? No increase or decrease in project costs is expected. With who have you discussed these changes? In-house, -selectable automatic gain control (AGC) that is peak- average adjustable to 28 decibels (dB). 54. A minimum, -pressurized dome-type housing enclosure is used, ensure that the unit is vented with a thermostat, outputs and streaming video feeds. Ensure that the unit provides direct digital streaming video through
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/january-2014/review/internal/6820000.origind.pdf?sfvrsn=53df3f05_07820000.origind
in an increase or decrease in project costs? If yes, what is the estimated change in costs? No increase or decrease in project costs is expected. With who have you discussed these changes? In-house, ) that is peak- average adjustable to 28 decibels (dB). 5. A minimum signal-to-noise ratio of 50 dB, , ensure that the unit is vented with a thermostat-controlled heater and blower. Ensure, that the unit provides direct digital streaming video through cable feeds using a digital video decoder
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/january-2014/review/internal/7820000.origind.pdf?sfvrsn=d6d950cb_06600000.origind
No Construction staff contact ed ( name ) : Will the proposed revision involve Pay Item changes, Interface (API) and software development kit available to the Department at no cost, at no cost for integration with third party software and systems. 660-2.1.2.3.2 C o m m u n i c, development kit available to the Department at no cost for integration with third party software, : N PA PA N i EM EM i 1 det , Where: EM PA = Average accuracy of all
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/january-2016/review/internal/6600000.origind.pdf?sfvrsn=c60a868b_0Agency Term Contracts - Printing of Educational Materials
: The Average Cost Per Unit will be used for award purposes ONLY. Bidders are required to bid on all, unit for all items. The Average Cost Per Unit will be obtained by adding the columns bid straight across. Then the sum is divided by the number of items bid for an Average Cost Per Unit. Prices Bid, + .10 = $1.50 1.50 ÷ 5 = .30 Item No. Description Estimated Quantities Avg. Cost Per Unit, to School Program Item No. Description Estimated Quantities Avg. Cost Per Unit Standard Packaging
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/procurement/files_agency_term_contracts/9100---contract-document.pdf?sfvrsn=331de585_82010Master
detailed in the plans. Controlling Work Items. Theactivity or work item on the critical path having the least amount of total float. The controlling item of work will also be referred to as a Critical, time of performance of any controlling work item under the Contract. The term “delay” is intended, . Theofficialtestinglaboratory used by the Department. Major Item of Work. Anyitem of work having, or the expedite program generated bid item sheets on which the Department requires formal bids
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2010/ebook/2010master.pdf?sfvrsn=a427c160_0ch09s01
in the United States. Appurtenance: Something added as an accessory or adjunct to a more important item, occurs, a business or farm operation: (A) Had average annual gross receipts of a least $5,000; or (B) Had average annual net earnings of at least $1,000; or (C) Contributed at least 33 1/3 percent of the owner's or operator's average annual income from all sources. (D) If these two (2) years, a single family house; a single family unit in a two family, multifamily, or multipurpose property
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/rightofway/documents/rowmanual/ch09s01.pdf?sfvrsn=a2f14742_3