2236 search results for bridge inspection
Bridge Inspection
Bridge Inspection, Bridge Inspection STATE OF FLORIDA TEAM, Inspection Team Leader will be reviewed on the third Thursday of April and October. Bridge, Inspection Field Guide Adobe PDF - 882 KB, Rev. Date 06-06-19 Florida Safety Bridge Inspection Team Leader, . Date 12-03-25 CONTACTS Bridge Inspection Program Manager Bruno Vasconcelos (850, Lessard (954) 934-1234 DOCUMENTS Bridge Inspection Program Manager Duties and Responsibilities Adobe PDF
https://www.fdot.gov/maintenance/divisions.shtm/structures/inspection.shtmOOM_20231222_FDOT Bridge Inspection Program Manager Duties
OOM_20231222_FDOT Bridge Inspection Program Manager Duties, Inspection Program Manager Duties The Bridge Inspection Program Manager is responsible for ensuring that the FDOT bridge inspection program meets the requirements of the National Bridge Inspection Standards (NBIS). The duties and responsibilities include: Ensure that bridge inspection team leaders meet the requirements of the NBIS. Update bridge inspection and operations procedures as required including: o 850-010-011 – Bridge and Other Structures Inspection and Reporting o
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/maintenance/str/bi/oom_20231222_fdot-bridge-inspection-program-manager-duties.pdf?sfvrsn=548798c5_1Safety Bridge Inspection Team Leader Requirements in Florida
Safety Bridge Inspection Team Leader Requirements in Florida, bridge inspections under the direct supervision of a qualified bridge inspection team leader. o, Bridge Inspection Team Leader Requirements in Florida The requirements for a bridge inspection team leader are listed in the National Bridge Inspection Standards (NBIS). The Florida Department, of 6 months’ experience conducting NBIS compliant bridge inspections. Professional engineers must, worked in these areas. Submission of form 850-010-16 “Application for Bridge Inspection
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/maintenance/str/bi/safety-bridge-inspection-team-leader-requirements-in-florida.pdf?sfvrsn=7dbf3e56_1OOM_20240403_Safety-Bridge-Inspection-Team-Leader-Requirements-in-Florida
OOM_20240403_Safety-Bridge-Inspection-Team-Leader-Requirements-in-Florida, compliant bridge inspections under the direct supervision of a qualified bridge inspection team leader, Inspection Team Leader Requirements in Florida The requirements for a bridge inspection team leader are listed in the National Bridge Inspection Standards (NBIS) §650.309(b). The Florida Department, . A minimum of 6 months’ experience conducting NBIS compliant bridge inspections. Professional, for the period worked in these areas. Submission of form 850-010-16 “Application for Bridge Inspection
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/maintenance/str/bi/oom_20240403_safety-bridge-inspection-team-leader-requirements-in-florida.pdf?sfvrsn=1a08f50f_12014eBook-editable
. Anindividual,firm,orcorporationsubmittingaproposalfortheproposedwork. Bridge. Astructure
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/ebook/2014ebook-editable.pdf?sfvrsn=33045af2_0Section112-032212
Bridge Alliance (AASHTO/NSBA) Steel Bridge Collaboration, Steel Bridge Fabrication QC/QA Guide Specification S4.1 American Welding Society (AWS) AASHTO/AWS D1.5/D1.5M, Bridge Welding Code American, inspectionandtestingofthesteelandmiscellaneousmetalproducts. 11.2.5GENERALINFORMATION
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2012/january-2012/materials-manual/section112-032212.pdf?sfvrsn=8d8b7746_1section112-32212
Bridge Alliance (AASHTO/NSBA) Steel Bridge Collaboration, Steel Bridge Fabrication QC/QA Guide Specification S4.1 American Welding Society (AWS) AASHTO/AWS D1.5/D1.5M, Bridge Welding Code American, inspectionandtestingofthesteelandmiscellaneousmetalproducts. 11.2.5GENERALINFORMATION
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2012/january-2012/materials-manual/section112-32212.pdf?sfvrsn=8edd1aa1_1OOM_20250702_Florida-Bridge-Information-2025-1st-Quarter
OOM_20250702_Florida-Bridge-Information-2025-1st-Quarter, Florida Bridge Information Q1 2025 COUNTYOWNERBRIDGESTRUCTURE NAMEROADWAYFACILITY CROSSEDADTYEAR BUILTLAST INSPECTIONCONDITIONSTATUS AlachuaState Highway Agency260001US-301 (SR-200)US-301, 1 of 348 Florida Bridge Information Q1 2025 COUNTYOWNERBRIDGESTRUCTURE NAMEROADWAYFACILITY CROSSEDADTYEAR BUILTLAST INSPECTIONCONDITIONSTATUS AlachuaState Highway Agency260057I-75 SB SR-93I-75 SB, )US-301 NB (SR-200)SANTA FE RIVER14,62519943/7/2024GoodOpen 7/2/2025Page 2 of 348 Florida Bridge
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/maintenance/str/bi/oom_20250702_florida-bridge-information-2025-1st-quarter.pdf?sfvrsn=3b32b9e4_1OOM_20251001_Florida-Bridge-Information-2025-4th-Quarter
OOM_20251001_Florida-Bridge-Information-2025-4th-Quarter, COUNTY OWNER BRIDGE STRUCTURE NAME ROADWAY FACILITY CROSSED ADTYEAR BUILTLAST INSPECTIONCONDITION, BRIDGE STRUCTURE NAME ROADWAY FACILITY CROSSED ADTYEAR BUILTLAST INSPECTIONCONDITION STATUS Bay, OWNER BRIDGE STRUCTURE NAME ROADWAY FACILITY CROSSED ADTYEAR BUILTLAST INSPECTIONCONDITION STATUS, COUNTY OWNER BRIDGE STRUCTURE NAME ROADWAY FACILITY CROSSED ADTYEAR BUILTLAST INSPECTIONCONDITION STATUS, Florida Bridge Information Q4 2025 COUNTY OWNER BRIDGE STRUCTURE NAME ROADWAY FACILITY CROSSED
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/maintenance/str/bi/oom_20251001_florida-bridge-information-2025-4th-quarter.pdf?sfvrsn=f589699b_1section8-2_3-5-12
, vibration, finishing and curing (Pre-pour inspection) (N) Inspectionofstructuresafterconcreteplacement, for the development and implementation of the inspection and testing programs for the manufacture, storage, cifications for Road and Bridge Construction (E) QualifiedProductsList, Structures Plants (Plants). These requirements and activities pertain to the inspections, measurements, N F O R M A T ION The Plants are responsible for production, inspection, storage, and shipment
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2012/january-2012/materials-manual/section8-2_3-5-12.pdf?sfvrsn=2e1363d2_1OOM_20230928_FDOT-Guidance-for-Highway-Tunnel-Inspection
OOM_20230928_FDOT-Guidance-for-Highway-Tunnel-Inspection, September 28, 2023 www.fdot.gov Inspection – Inspections shall be performed in compliance, in between the routine inspections. These inspections will be documented in the Tunnel module of the Bridge, of the Bridge Management System. • In-depth inspection – An in-depth inspection may be required, division Bridge Engineer and the Tunnel Inspection Program Manager a summary report of the current, Bridge Engineer and the Tunnel Inspection Program Manager that there are currently no critical findings
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/maintenance/str/ti/oom_20230928_fdot-guidance-for-highway-tunnel-inspection.pdf?sfvrsn=f026de4_1OOM_20240403_FDOT-Guidance-for-Highway-Tunnel Inspection
OOM_20240403_FDOT-Guidance-for-Highway-Tunnel Inspection, for Highway Tunnel Inspection Inspection – Inspections shall be performed in compliance, the routine inspections. These inspections will be documented in BrM. Damage Inspection – After, if a damage inspection is required and what portions of the tunnel require inspections. These inspections will be documented in BrM. In-depth inspection – An in-depth inspection may be required, the FHWA division Bridge Engineer and the Tunnel Inspection Program Manager a summary report
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/maintenance/str/ti/oom_20240403_fdot-guidance-for-highway-tunnel-inspection.pdf?sfvrsn=4da6e42f_1Section111-102714
with the verification inspection on a particular project conduct Independent Assurance inspections and perform, inspection must be a Certified Welding Inspector (CWI) or equivalent, in accordance with the Bridge, Fabrication Inspection and Testing of Structural Metal Products11-1-1 Topic No.: 675-000-000, , 2014 CHAPTER 11.1 FABRICATION INSPECTION AND TESTING OF STRUCTURAL METAL PRODUCTS 11.1.1, the inspection and acceptance criteria of metal products for Department projects statewide. 11.1.2
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/july-2014/materials-manual/section111-102714.pdf?sfvrsn=813e6eaa_1Section62V2
(FAPG), Subchapter G – Engineering and Traffic Operations, Part 637 – Construction Inspection, and Bridge Construction, Topic No. 625-010-003, Florida Department of Transportation (FDOT) Florida Department of Transportation Standard Specifications for Road and Bridge Construction American Society, to the inspections, measurements, and necessary tests to substantiate materials and Pipe in conformity, for the production, inspection, storage, and shipment of the Pipe. The Ensure that the delivered Pipe
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2020/july-2020/materials-manual/redline/section62v2.pdf?sfvrsn=9936239c_11020302.FHWA
. 2.Isonsiteduringallsetupandtakedown,andperforms a drive through inspection immediately after set up, . 6.Conductsdailydaytime and weekly nighttime inspections of projects with predominately daytime work activities, and daily nighttime and weekly daytime inspections of projects with predominantly, inspectionsandgivethemtheopportunitytojoinintheinspectionasisdeemed necessary. Submit a comprehensive weekly report, using, devices (including pavement markings) being used. Include assurances in the inspection report Ensure
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/july-2014/review/fhwa/1020302.fhwa.pdf?sfvrsn=4e548c9f_01020302.FHWA-REVISED
. 2.Isonsiteduringallsetupandtakedown,andperforms a drive through inspection immediately after set up, arrangements. 6.Conductsdailydaytime and weekly nighttime inspections of projects with predominately daytime work activities, and daily nighttime and weekly daytime inspections of projects, inspectionsandgivethemtheopportunitytojoinintheinspectionasisdeemed necessary. Submit a comprehensive weekly report, using, control devices (including pavement markings) being used. Include assurances in the inspection report
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/july-2014/review/fhwa/1020302.fhwa-revised.pdf?sfvrsn=a4c28839_0Section113-042214
in Nondestructive Testing AASTHO/AWS D1.5 Bridge Welding Code AWS D1.1 Structural Welding Code-Steel ISO 2400 Non, requirements, calibration, equipment verification, inspection technique, acceptance criteria, information relative to the beam angle or angles used during the inspection. This correction is found to be useful to compensate for surface path distance variations in angle beam inspections. 11.3.7, :Inspectionsshallbeperformedusingphased arraypulse-echoequipmentwhichmeetstherequirementsof6.22(6.15
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/july-2014/materials-manual/section113-042214.pdf?sfvrsn=13116df_1OOM_20240319_DSME-Memo-24-01-Modifications-to-Procedure-850-010-030
: Modifications to the Bridge and Other Structures Inspection and Reporting Procedure, Topic, CFR Part 650, National Bridge Inspection Standards (NBIS). The objectives in implementing, Modifications to sections in the Bridge and Other Structures Inspection and Reporting procedure to meet, to their regulation on the National Bridge Inspection Standards (NBIS) for the first time since 2009. To comply, Structures Inspection Roles and Responsibilities Bridge Inspection Program Manager - responsible
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/maintenance/memos/oom_20240319_dsme-memo-24-01-modifications-to-procedure-850-010-030.pdf?sfvrsn=b3b5e6ce_1OOM_20250611_DSME-Memo-25-02- Inspection-of-Department-Owned-Railroad-Bridges
OOM_20250611_DSME-Memo-25-02- Inspection-of-Department-Owned-Railroad-Bridges, and adds these bridges into the Department’s highway bridge inspection program. Requirements 1. Add, not to exceed 24 months. Railroad bridge inspections shall be conducted in accordance with the state, the Department’s Bridge Management System. The inspection reports will be reviewed by the District Structures Maintenance Offices in the same manner as bridge inspection reports. A copy, to the procedure are effective immediately. Contact Bruno Vasconcelos, P.E. State Bridge Inspection
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/maintenance/memos/oom_20250611_dsme-memo-25-02--inspection-of-department-owned-railroad-bridges.pdf?sfvrsn=f4a2164_11020302.impl
. Advisetheprojectpersonnelofthescheduleofthese inspectionsandgivethem the opportunity to join in the inspection, . 2.Isonsiteduringallsetupandtakedown,andperforms a drive through inspection immediately after set up, nighttime inspections of projects with predominately daytime work activities, and daily nighttime and weekly daytime inspections of projects with predominantly nighttime work activities of all traffic, Standards, Index Nos. 412, 415 or 414. Temporary concrete barrier wall used on bridge and wall
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/january-2016/review/implemented/1020302.impl.pdf?sfvrsn=4df67286_0