9191 search results for test

719eBook

American Society of Mechanical Engineers ASTM American Society for Testing and Materials AWG, , test method, or other code or recommendation of the particular authority or organization shown. Use standards, specifications, test methods, or other codes as specified in the current edition, furnished and of the work performed by the Contractor. Laboratory. The official testing laboratory used

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2019/july-2019/ebook/719ebook.pdf?sfvrsn=bf366a48_2

719eBook_SS_DLH

American Society of Mechanical Engineers ASTM American Society for Testing and Materials AWG, , test method, or other code or recommendation of the particular authority or organization shown. Use standards, specifications, test methods, or other codes as specified in the current edition, furnished and of the work performed by the Contractor. Laboratory. The official testing laboratory used

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2019/july-2019/ebook/719ebook_ss_dlh.pdf?sfvrsn=76a63a43_2

119eBookRedline

Engineers ASME American Society of Mechanical Engineers ASTM American Society for Testing, designation, or combination of numbers and letters, designates a specification, test method, or other code, , specifications, test methods, or other codes as specified in the current edition at the time of the bid opening, . The official testing laboratory used by the Department. R e d l i n e V e r s i o n - F, of the work, together with samples that may be subjected to the tests provided

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2019/january-2019/ebook/119ebookredline86e831a5ccd14cf79a27632da0ce823c.pdf?sfvrsn=b33bde59_0

7110402.resp

 7110402 THERMOPLASTIC TRAFFIC STRIPES AND MARKINGS COMMENTS FROM INTERNAL/INDUSTRY REVIEW Tim Ruelke 352-955-6620 timothy.ruelke@dot.state.fl.us Comments: (6-9-13) Do you want to consider adding “resolution” language in case the Engineer’s verification tests fail? Response: No, the specification addresses the resolution. No changes made. ****************************************************************************** Paul Gentry paul.gentry@dot.state.fl.us Comments: (6-17-13) Why

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan14/files/7110402.resp.pdf?sfvrsn=72b5d061_0

InternalCommentResponse1200101-dj

Name: Charles Miller Date: 7-31-24 COMMENT: Language: 120-10.2.2 Density Testing Requirements, for density requirement. Language: 120-10.2.5 Test Selection and Reporting: Determine test locations, testing on each LOT prior to placing another lift on top. Comment: Language should be added to clarify, Test Selection and Reporting: Determine test locations including stations and offsets, using, for later transfer to the ERS. Notify the Engineer upon successful completion of QC testing

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2025-26/review/internal/comments-responses/internalcommentresponse1200101-dj.pdf?sfvrsn=470a7a50_1

4100200.origind

absorption tests on specimens from each LOT of dry-cast production in accordance with the test methods, tests to one test every five LOTs when the results of five consecutive LOTs meet the specified limit, Materials Office. Background data: The hydrostatic testing requirements of ASTM C-1677 meet, General: Meet the requirements of Section 346, except as modified herein: Prepare, cure, and test the test cylinders in accordance with ASTM C-31 and ASTM C-39 test methods. Follow the alternative

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul12/files/4100200.origind.pdf?sfvrsn=9f30e2b2_0

5600000impl

. Conduct the non-abrasive residue and lead content tests as directed by the Engineer. If test, salts test kits meeting the requirements of 560-2.4. Perform the tests after washing and after each, Conductivity ≤ 7 µg/cm 2 Chlorides Between Coats 3 tests (first 1,000 ft 2 ) 1 test (ea, by the coating manufacturer as part of the coating system. 560-2.4 Soluble Salts Test Kit: Measure, conductivity meter, fiber strip or multi-step patch, cell, or ring. Ensure the test sleeve or cell

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul19/files/5600000impl.pdf?sfvrsn=db3bccf8_2

119eBook

of Civil Engineers ASME American Society of Mechanical Engineers ASTM American Society for Testing, , designates a specification, test method, or other code or recommendation of the particular authority or organization shown. Use standards, specifications, test methods, or other codes as specified, testing laboratory used by the Department. 5 Major Item of Work. Any item of work having

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2019/january-2019/ebook/119ebook.pdf?sfvrsn=abd5f2d5_6

119eBook_SS_DLH

of Civil Engineers ASME American Society of Mechanical Engineers ASTM American Society for Testing, , designates a specification, test method, or other code or recommendation of the particular authority or organization shown. Use standards, specifications, test methods, or other codes as specified, testing laboratory used by the Department. 5 Major Item of Work. Any item of work having

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2019/january-2019/ebook/119ebook_ss_dlh.pdf?sfvrsn=9d1a277_0

D4490000.do

removed from the form. (d)Ensurethemanufacturer has a suitable apparatus for testing each product in accordance with ASTM C 497 [ASTM C 497M] and performs all tests outlined in ASTM C 497 [ASTM C 497M, as required in Section 10.2 of ASTM C 1450 except the specimen will be tested by the appropriate section of ASTM C 497 [ASTM C 497], External Load Crushing Strength by the Three-Edge Bearing Test, . InlieuofSection7.1ofASTMC1450meet the following: All material tested under this Specification must be tested in the saturated

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2003/files/d4490000.do.pdf?sfvrsn=871f2108_0

5480203int

independent testing laboratory prior to placement. Have all backfill material tested for electro-chemical properties as specified in Table 548-1 and 548-2. All electro-chemical testing shall be performed, : Summary: Clarification on how to address high water elevations and environmental testing, and environmental testing for corrosivity. Do the changes affect other types of specifications? Neither, the requirements of Sections 105 and 120 except as noted within this Section. Have the backfill material tested

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2026-27/review/internal/5480203int.pdf?sfvrsn=7cf07a70_1

5480203ind

independent testing laboratory prior to placement. Have all backfill material tested for electro-chemical properties as specified in Table 548-1 and 548-2. All electro-chemical testing shall be performed, : Summary: Clarification on how to address high water elevations and environmental testing, and environmental testing for corrosivity. Do the changes affect other types of specifications? Neither, the requirements of Sections 105 and 120 except as noted within this Section. Have the backfill material tested

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2026-27/review/industry/5480203ind.pdf?sfvrsn=1bf2657b_1

9300000.comm

and Ultra-high Performance? Will the pourable version of the vertical products be tested for all, ? Have the products currently listed been tested this way (pourable)? Response, the test results. 4. I think the intent is to have the strength of the repair material approximately match, bond testing, using a high strength substrate thatis quite rough and in a SSD condition creates, very dry or saturated wet.Tensile adhesion testing per ASTM C1583 with defined substrate properties

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul12/files/9300000.comm.pdf?sfvrsn=ba74d57_0

4300048SSFHWA

further testing of the pipe as a result of the inspection. If so directed by the Engineer, test pipe, for deflection. The Engineer may require further testing of the pipe as a result of the inspection. If so directed by the Engineer, test pipe 36 inches [900 mm] and less in diameter using a mandrel, . If use of a mandrel is selected as the means of further testing, the mandrels diameter, length, test prove that the pipe met specifications, the Department will bear the cost of the deflection

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan05/files/4300048ssfhwa.pdf?sfvrsn=f0de4170_0

4551508.impl

. Perform the following tests on the polymer slurry in the shaft excavation and ensure that the results, to be measured Range of Results at 68ºF Test Method Density 62 to 65 lb/ft 3 (fresh water) 64, of the shaft in accordance with the manufacturer’s published procedures. Test and verify the polymer slurry, : 455-17.6.1.2 Procedure: Perform CSL testing between 120 hours and 25 calendar days of shaft concrete, of testing. Verify access tube lengths and their condition in the presence of the Department, at least 24

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2017/january-2017/review/implemented/4551508.impl.pdf?sfvrsn=522cc119_0

D4530000.do

, modify the ASTM test procedures as noted. The components of the epoxy-bonding agent shall be conditioned to the temperature at which testing is to be done prior to mixing the test specimen. 453-4.5.2, if a slant cylinder test specimen, prepared and tested in accordance with the conditions below, ] at 28 days when tested to ASTM C39. The slant- cylinder test procedure must be in accordance, . Forslow-setepoxy, an additional test specimen shall be made and tested to failure at 24 hours

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2003/files/d4530000.do.pdf?sfvrsn=aebce8f3_0

D4530000.do

, modify the ASTM test procedures as noted. The components of the epoxy-bonding agent shall be conditioned to the temperature at which testing is to be done prior to mixing the test specimen. 453-4.5.2, if a slant cylinder test specimen, prepared and tested in accordance with the conditions below, ] at 28 days when tested to ASTM C39. The slant- cylinder test procedure must be in accordance, . Forslow-setepoxy, an additional test specimen shall be made and tested to failure at 24 hours

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2003/files/d4530000.doc50b2ef30e00412dbca43632f7ba7cca.pdf?sfvrsn=a2b8ceed_0

D4530000.do

test procedures as noted. The components of the epoxy-bonding agent shall be conditioned to the temperature at which testing is to be done prior to mixing the test specimen. 453-4.5.2 Contact Time, cylinder test specimen, prepared and tested in accordance with the conditions below, sustains, when tested to ASTM C39. The slant- cylinder test procedure must be in accordance with ASTM C882, , an additional test specimen shall be made and tested to failure at 24 hours. The formulation

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2004/january-2004/workbook/d4530000.do.pdf?sfvrsn=a097ca73_0

7-20eBook(Signed and Sealed)

ASTM American Society for Testing and Materials AWG American Wire Gauge AWPA American Wood, designation, or combination of numbers and letters, designates a specification, test method, or other code, , test methods, or other codes as specified in the current edition at the time of the bid opening, furnished and of the work performed by the Contractor. Laboratory. The official testing laboratory used

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2020/july-2020/ebook/7-20ebook(signed-and-sealed).pdf?sfvrsn=e7b19000_4
20 of 9191 results