Design Standards 2015

Index Number Design Standards Revision (DSR) Index Title Design Information
Instructions for Design Stds (IDS) Data Table Cell Library Borderless DGNs

(PDF)

(PDF) (ZIP) (ZIP)
Terms of Use
 
Complete eBook
(252mb)

2015 Design Standards eBook

Effective Jan 1 - December 31

 

Combined Available IDS
(11mb)
Combined Available CELs
(1mb)
Combined Available DGNs
(57mb)
 COVER, TABLE OF CONTENTS AND REVISIONS 
Cover  Book Cover Cover  
Content  Table of Contents Content  
Revisions  Revision History Introduction  
Revisions
 ABBREVIATIONS AND SYMBOLSRoadway Contact
001  Standard Abbreviations    
002  Standard Symbols    
 EROSION CONTROL AND WATER QUALITY 
104  Permanent Erosion Control    
105  Shoulder Sodding and Turf on Existing Facilities    
 DRAINAGE 
200 Structure Bottoms - Type J & P   
201 Supplementary Details for Manholes & Inlets   
205 Pipe Backfill   
206 Trench Drain   
210 Curb Inlet Tops - Types 1, 2, 3 & 4   
211 Curb Inlet Tops - Types 5 & 6   
212 Curb Inlet - Type 7   
213 Curb Inlet - Type 8   
214 Curb Inlet Top - Type 9   
215 Curb Inlet Top - Type 10   
216 Closed Flume Inlet   
217 Median Barrier Inlets Types 1, 2, 3, 4 and 5   
218 Barrier Wall Inlet   
219 Concrete Barrier Wall Inlet   
220 Gutter Inlet - Type S   
221 Gutter Inlet - Type V   
230 Ditch Bottom Inlet - Type A   
231 Ditch Bottom Inlet - Type B   
232 Ditch Bottom Inlets - Types C, D, E and H   
233 Ditch Bottom Inlets - Types F and G   
234 Ditch Bottom Inlet - Type J   
235 Ditch Bottom Inlet - Type K   
240 Skimmer for Outlet Control Structures   
241 Skimmers for Frenchdrain Outlets   
245 Underdrain Inspection Box   
250 Straight Concrete Endwalls - Single and Multiple Pipe   
251 Straight Concrete Endwalls - Single and Double 60" Pipe   
252 Straight Concrete Endwalls - Single and Double 66" Pipe   
253 Straight Concrete Endwalls - Single and Double 72" Pipe   
255 Straight Concrete Endwall - Single 84" Pipe   
258 Straight Sand - Cement Endwalls   
260 U-Type Concrete Endwalls With Grates - 15" to 30" Pipe   
261 U-Type Concrete Endwalls - Baffles and Grate Optional - 15" to 30" Pipe   
264 U-Type Concrete Endwall - Energy Dissipator - 30" to 72" Pipe   
266 Winged Concrete Endwalls - Single Round Pipe   
268 U-Type Sand-Cement Endwalls   
270 Flared End Section   
272 Cross Drain Mitered End Section   
273 Side Drain Mitered End Section   
280 Miscellaneous Drainage Details   
281 Ditch Pavement and Sodding   
282 Back of Sidewalk Drainage   
283 Median Opening Flume   
284 Concrete Shoulder Gutter Spillway   
285 French Drain   
286 Underdrain   
287 Concrete Pavement Subdrainage   
288 Deep Well Injection Box   
289 Concrete Box Culvert Details (LRFD)IDS-289CEL-289 DGN-289
291 Supplemental Details for Precast Concrete Box CulvertsIDS-291 DGN-291
292 Standard Precast Concrete Box CulvertsIDS-292 DGN-292
293 Safety Modifications for Inlets In Box Culverts   
295 Safety Modifications for Endwalls   
 CURBS, CONCRETE PAVEMENT & SIDEWALKS  
300 Curb & Curb And Gutter   
301 Turn Lanes   
302 Traffic SeparatorsIDS-302  
303 Curb Return Profiles   
304 Detectable Warnings and Sidewalk Curb RampsIDS-304  
305 Concrete Pavement Joints   
306 Bridge Approach Expansion Joint - Concrete Pavement   
307 Miscellaneous Utility Details   
308 Concrete Slab Replacement   
310 Concrete Sidewalk   
 

TRAFFIC RAILINGS

 
400 GuardrailIDS-400  
402 Guardrail Transitions and Connections for Existing BridgesIDS-402   
403 Guardrail Transitions for Existing Bridge Traffic Railing RetrofitsIDS-403   
404 Guardrail Transitions - Existing Post & Beam Bridge Railings (Narrow & Recessed Curbs)IDS-404 DGN-404
405 Guardrail Transitions - Existing Post & Beam Bridge Railings (Wide Curbs)IDS-405 DGN-405
410 Concrete Barrier Wall   
411 Pier Protection BarrierIDS-411  
412DSRLow Profile Barrier   
414 Type K Temporary Concrete Barrier SystemIDS-414   
415 Temporary Concrete Barrier   
420 Traffic Railing - (32" F Shape)IDS-420 DGN-420
421 Traffic Railing - (Median 32" F Shape)IDS-421  DGN-421
422 Traffic Railing - (42" Vertical Shape)IDS-422  DGN-422
423 Traffic Railing - (32" Vertical Shape)IDS-423 DGN-423
424 Traffic Railing - (Corral Shape)IDS-424 DGN-424
425 Traffic Railing - (42" F Shape)IDS-425 DGN-425
430 Crash Cushion DetailsIDS-430  
461 Opaque Visual Barrier   
470 Traffic Railing - (Thrie Beam Retrofit) General Notes & DetailsIDS-470 DGN-470
471 Traffic Railing - (Thrie Beam Retrofit) Narrow Curb DGN-471
472 Traffic Railing - (Thrie Beam Retrofit) Wide Strong Curb Type 1 DGN-472
473 Traffic Railing - (Thrie Beam Retrofit) Wide Strong Curb Type 2 DGN-473
474 Traffic Railing - (Thrie Beam Retrofit) Intermediate Curb DGN-474
475 Traffic Railing - (Thrie Beam Retrofit) Wide Curb Type 1 DGN-475
476 Traffic Railing - (Thrie Beam Retrofit) Wide Curb Type 2 DGN-476
477 Thrie-Beam Panel Retrofit (Concrete Handrail)IDS-477 DGN-477
480 Traffic Railing - (Vertical Face Retrofit) General Notes & DetailsIDS-480 DGN-480
481 Traffic Railing - (Vertical Face Retrofit) Narrow Curb DGN-481
482 Traffic Railing - (Vertical Face Retrofit) Wide Curb DGN-482
483 Traffic Railing - (Vertical Face Retrofit) Intermediate Curb DGN-483
484 Traffic Railing - (Vertical Face Retrofit) Spread Footing Approach DGN-484
 

GENERAL

 
500 Removal of Organic and Plastic Material   
501DSRGeosynthetic Reinforced SoilsIDS-501  DGN-501
505 Embankment Utilization   
506 Miscellaneous Earthwork Details   
510 Superelevation - Rural Highways, Urban Freeways and High Speed Urban Highways   
511 Superelevation - Urban Highways and Streets   
514 Optional Base Group and Structural Numbers   
515 Turnouts   
516 Turnouts - Resurfacing Projects   
517 Raised Rumble Strips   
518 Shoulder Rumble Strips   
519DSRRumble Striping   
521 Concrete StepsIDS-521   
525 Ramp Terminals   
526 Roadway Transitions   
527 Directional Median Openings   
530 Rest Area Pavilion   
532 Mailboxes   
535 Tractor Crossings   
540 Settlement Plate  DGN-540
544 Landscape Installation   
546 Sight Distance at Intersections   
560 Railroad Crossings   
 TRAFFIC CONTROL THROUGH WORK ZONES  
600DSRGeneral Information for Traffic Control Through Work Zones   
601 Two-Lane, Two-Way, Work Outside Shoulder   
602 Two-Lane, Two-Way, Work on Shoulder   
603DSRTwo-Lane, Two-Way, Work Within the Travel Way   
604 Two-Lane, Two-Way, Work in intersection   
605 Two-Lane, Two-Way, Work Near Intersection   
606 Two-Lane, Two-Way, Work Within the Travel Way - Signal Control   
607DSRTwo-Lane, Two-Way, Mobile Operation, Work on Shoulder, Work Within the Travel Way   
608 Two-Lane, Two-Way, Temporary Diversion Connection   
611 Multilane, Work Outside Shoulder   
612 Multilane, Work on Shoulder   
613 Multilane, Work Within the Travel Way - Median or Outside Lane   
614 Multilane, Work Within the Travel Way - Center Lane   
615 Multilane, Work in Intersection   
616 Multilane, Work Near Intersection - Median or Outside Lane   
617 Multilane, Work in Intersection - Center Lane   
618 Multilane, Work in Intersection - Two Lanes Closed - 45 mph or Less   
619DSRMultilane, Mobile Operations, Work on Shoulder, Work Within the Travel Way   
620 Multilane, Divided, Temporary Diversion Connection   
621 Multilane, Undivided, Temporary Diversion Connection   
622 Multilane, Work Near Intersection-Temporary Diversion Connection-35 mph or Less   
623 Multilane, Work Within the Travel Way Double Lane Closure   
625 Temporary Road Closure - 5 Minutes or Less   
628 Two-Way Left Turn Lane Closure   
630 Crossover for Paving Train Operations, Rural   
631 Temporary Crossover   
635 Work in Vicinity of Railroad Crossing   
640 Converting Two-Lanes to Four-Lanes Divided, Rural   
641 Converting Two-Lanes to Four-Lanes Divided, Urban   
642 Transitions for Temporary Concrete Barrier Wall on Freeway Facilities   
650 Two-Lane, Two-Way Rural Structure Replacement   
651 Multilane, Divided, Maintenance and Construction   
655 Traffic Pacing   
660 Pedestrian Control for Closure of Sidewalks   
665 Limited Access, Temporary Opening   
667 Toll Plaza, Traffic Control Standards   
670 Motorist Awareness System   
 

ROADSIDE SAFETY

 
700 Roadside OffsetsIDS-700  
 

FENCING AND PEDESTRIAN RAILINGS

 
800 Fence Location   
801 Fence - Type A   
802 Fence - Type B   
803 Cantilever Slide Gate - Type B Fence   
810 Bridge Fencing (Vertical)IDS-810 DGN-810
811 Bridge Fencing (Curved Top)IDS-811 DGN-811
812 Bridge Fencing (Enclosed)IDS-812 DGN-812
820 Bridge Pedestrian/Bicycle Bullet RailingIDS-820 DGN-820
821 Bridge Aluminum Pedestrian/Bicycle Bullet Railing for Traffic Railing (32" F Shape)IDS-821 DGN-821
822 Bridge Aluminum Pedestrian/Bicycle Bullet Railing DetailsIDS-822 DGN-822
825 42" Concrete Pedestrian/Bicycle RailingIDS-825 DGN-825
851 Bridge Pedestrian/Bicycle Railing (Steel)IDS-851 DGN-851
852 Steel Pedestrian/Bicycle RailingIDS-852CEL-852

CEL-852-CTIP

DGN-852
861 Bridge Pedestrian/Bicycle Railing (Aluminum)IDS-861 DGN-861
862 Aluminum Pedestrian/Bicycle RailingIDS-862CEL-862

CEL-862-CTIP

DGN-862
870 Aluminum Pipe GuiderailIDS-870  
880 Steel Pipe GuiderailIDS-880  
 

NOISE AND PERIMETER WALL SYSTEMS

 
5200 Precast Noise WallsIDS-5200CEL-5200

CEL-5200-Graphics

DGN-5200
5210 Traffic Railing/Noise Wall (8'-0")IDS-5210 DGN-5210
5211 Traffic Railing/Noise Wall (14'-0")IDS-5211 DGN-5211
5212 Traffic Railing/Noise Wall (8'-0") Junction SlabIDS-5212 DGN-5212
5213 Traffic Railing/Noise Wall T-Shape Spread FootingIDS-5213 DGN-5213
5214 Traffic Railing/Noise Wall L-Shaped Spread FootingIDS-5214 DGN-5214
5215 Traffic Railing/Noise Wall Trench FootingIDS-5215 DGN-5215
5250 Perimeter WallsIDS-5250CEL-5250DGN-5250
 

WALL SYSTEMS

 
6010 C-I-P Cantilever Retaining WallIDS-6010CEL-6010DGN-6010
6011 Gravity WallIDS-6011 DGN-6011
6020 Permanent MSE Retaining Wall SystemsIDS-6020CEL-6020DGN-6020
6030 Temporary MSE Retaining Wall SystemsIDS-6030CEL-6030DGN-6030
6040 Precast Concrete Sheet Pile WallIDS-6040CEL-6040-CSPDA

CEL-6040-CSPC

CEL-6040-CSPSA

DGN-6040
6100 MSE Wall Coping (Precast or C-I-P)IDS-6100 DGN-6100
6110 Wall Coping With Traffic Railing/Junction Slab DGN-6110
6120 Wall Coping With Traffic Railing/Raised Sidewalk DGN-6120
6130 Wall Coping/Parapet With C-I-P Sidewalk DGN-6130
6200 Coping Mounted Light Pole Pedestal  DGN-6200
6201 Junction Slab at Drainage Inlet Openings  DGN-6201
 

SIGNING AND MARKING

 
11200DSRMulti-Column Ground SignIDS-11200  
11300 Steel Overhead Sign Structures   
11310 Cantilever Sign StructureIDS-11310CEL-11310 
11320 Span Sign StructureIDS-11320CEL-11320 
11860DSRSingle Column Ground SignsIDS-11860  
11861 Single Column Cantilever Ground Mounted Sign   
11862DSRRoadside Flashing Beacon Assembly   
11870 Single Post Bridge Mounted Sign SupportIDS-11870 DGN-11870
11871 Single Post Median Barrier Mounted Sign SupportIDS-11871  
13417DSRMounting Exit Number Panels to Highway Signs   
17302DSRTypical Sections for Placement of Single & Multi-Column Signs   
17328 Typical Signing for Truck Weigh and Inspection Stations   
17344 School Signs & Markings   
17345 Interchange Markings   
17346DSRSpecial Marking Areas   
17347DSRBicycle Markings   
17349 Traffic Controls for Street Terminations   
17350 Signing for Motorist Services   
17351 Welcome Center Signing   
17352 Typical Placement of Reflective Pavement Markers   
17354 Tourist Oriented Directional Signs   
17355 Special Sign Details   
17356 Span Wire Mounted Sign Details   
17357 Bridge Weight Restrictions   
17359 Rural Narrow Bridge Treatment   
 

ROADWAY LIGHTING

 
17500 Conventional Lighting   
17501 Highway Lighting General Notes   
17502 High Mast LightingIDS-17502  
17504 Service Point Details   
17505 External Lighting for SignsIDS-17505  
17515 Standard Aluminum LightingIDS-17515  
 

TRAFFIC SIGNAL AND EQUIPMENT

 
17700 Pull and Splice Box   
17721 Conduit Installation Details   
17723 Steel Strain PoleIDS-17723  
17725 Concrete PolesIDS-17725  
17727DSRSignal Cable and Span Wire Installation Details   
17733 Aerial Interconnect   
17736 Electric Power Service   
17743 Standard Mast Arm AssembliesIDS-17743CEL-17743 
17745 Mast Arm AssembliesIDS-17745CEL-17745 
17748 Free-Swinging, Internally-Illuminated Street Sign Assemblies   
17764 Pedestrian Control Signal Installation Details   
17781 Vehicle Loop Installation Details   
17784 Pedestrian Detector Assembly Installation Details   
17841DSRCabinet Installation Details   
17870 Standard Signal Operating Plans   
17881 Advance Warning for R/R Crossing   
17882 Railroad Grade Crossing Traffic Control Devices   
17890 Traffic Control Devices for Movable Span Bridge Signals   
 

PLANNING

 
17900 Traffic Monitoring Site   
 INTELLIGENT TRANSPORTATION SYSTEMS 
18100 CCTV Pole Placement   
18101 Typical CCTV Site   
18102 Grounding and Lightning Protection   
18104 Typical CCTV Cabinet Equipment Layout   
18105 CCTV Block Diagram   
18107 Ground Mounted CCTV Cabinet   
18108 Pole Mounted CCTV Cabinet   
18110 Camera Mounting Details   
18111 Steel CCTV PoleIDS-18111  
18113 Concrete CCTV PoleIDS-18113  
18300 Dynamic Message Sign Walk-In   
 

PRESTRESSED CONCRETE BEAMS

 
20005 Prestressed I-Beam Temporary BracingIDS-20005CEL-20005DGN-20005
20010 Typical Florida-I Beam Details and NotesIDS-20010CEL-20010DGN-20010
20036 Florida-I 36 Beam - Standard DetailsDGN-20036
20045 Florida-I 45 Beam - Standard DetailsDGN-20045
20054 Florida-I 54 Beam - Standard DetailsDGN-20054
20063 Florida-I 63 Beam - Standard DetailsDGN-20063
20072 Florida-I 72 Beam - Standard DetailsDGN-20072
20078 Florida-I 78 Beam - Standard DetailsDGN-20078
20084 Florida-I 84 Beam - Standard DetailsDGN-20084
20096 Florida-I 96 Beam - Standard DetailsDGN-20096
20120 AASHTO Type II BeamIDS-20120CEL-20120DGN-20120
20199 Build-Up & Deflection Data for Prestressed I-BeamsIDS-20199CEL-20199DGN-20199
20210 Typical Florida-U Beam Details and NotesIDS-20210CEL-20210DGN-20210
20248 Florida-U 48 Beam - Standard DetailsDGN-20248
20254 Florida-U 54 Beam - Standard DetailsDGN-20254
20263 Florida-U 63 Beam - Standard DetailsDGN-20263
20272 Florida-U 72 Beam - Standard DetailsDGN-20272
20299 Build-up and Deflection Data for Florida-U BeamsIDS-20299CEL-20299DGN-20299
 

BRIDGE BEARINGS

 
20502 Beveled Bearing Plate Details - Prestressed Florida-U BeamsIDS-20502CEL-20502DGN-20502
20510 Composite Elastomeric Bearing Pads - Prestressed Florida-I & AASHTO Type II BeamsIDS-20510CEL-20510DGN-20510
20511 Bearing Plates (Type I) - Prestressed Florida-I & AASHTO Type II BeamsIDS-20511CEL-20511DGN-20511
20512 Bearing Plates (Type 2) - Prestressed Florida-I & AASHTO Type II BeamsIDS-20512CEL-20512DGN-20512
 

SQUARE AND ROUND CONCRETE PILES

 
20600 Notes and Details for Square Prestressed Concrete PilesIDS-20600CEL-20600DGN-20600
20601 Square Prestressed Concrete Pile SplicesDGN-20601
20602 EDC Instrumentation for Square Prestressed Concrete PilesDGN-20602
20612 12'' Square Prestressed Concrete PileDGN-20612
20614 14'' Square Prestressed Concrete PileDGN-20614
20618 18'' Square Prestressed Concrete PileDGN-20618
20620 20'' Square Prestressed Concrete PileDGN-20620
20624 24'' Square Prestressed Concrete PileDGN-20624
20630 30'' Square Prestressed Concrete PileDGN-20630
20631 High Moment Capacity 30'' Square Prestressed Concrete PileDGN-20631
20654 54'' Precast/Post-Tensioned Concrete Cylinder PileIDS-20654DGN-20654
20660 60'' Prestressed Concrete Cylinder PileIDS-20660DGN-20660
 

APPROACH SLABS

 
20900 Approach Slabs (Flexible Pavement Approaches)IDS-20900CEL-20900DGN-20900
20910 Approach Slabs (Rigid Pavement Approaches)IDS-20910CEL-20910DGN-20910
 

BRIDGE EXPANSION JOINTS

 
21100 Strip Seal Expansion JointIDS-21100CEL-21100DGN-21100
21110 Poured Joint With Backer Rod Expansion Joint SystemIDS-21110CEL-21110DGN-21110
 

STRUCTURES ACCESS AND LIGHTING


21200 Light Pole PedestalIDS-21200 DGN-21200
21210 Conduit DetailsIDS-21210 DGN-21210
21220 Navigation Light System Details (Fixed Bridges)IDS-21220 DGN-21220
21240 Maintenance Lighting for Box GirdersIDS-21240 DGN-21240
21250 Access Hatch Assembly for Steel Box SectionsIDS-21250 DGN-21250
21251 Access Hatch Assembly for Concrete Box Sections DGN-21251
21252 Access Door Assembly for Steel Box SectionsIDS-21252CEL-21252DGN-21252
 

STANDARD BAR BENDING DETAILS

 
21300 Standard Bar Bending DetailsIDS-21300 DGN-21300
 

TEMPORARY DETOUR BRIDGES

 
21600 Temporary Detour Bridge General Notes and DetailsIDS-21600CEL-21600DGN-21600
21610 Temporary Detour Bridge Details -Timber Pile FoundationsDGN-21610
21620 Temporary Detour Bridge Details -Steel H Pile FoundationsDGN-21620
21630 Temporary Detour Bridge Details -Steel Pipe Pile FoundationsDGN-21630
21640 Temporary Detour Bridge Thrie-Beam GuardrailDGN-21640
 

POST-TENSION DETAILS

 
21801 Post-Tensioning Vertical ProfilesIDS-21800CEL-21800b

CEL-21800t

DGN-21801
21802 Post-Tensioning Anchorage ProtectionDGN-21802
21803 Post-Tensioning Anchorage and Grouting DetailsDGN-21803
 

FENDER SYSTEM DETAILS

 