Office of Design
To skip directly to groups of Indexes, click on the index series: 100, 200, 300, 400, 500, 600, 700, 800, 5200, 6000, 11200, 13000, 17300, 17500, 17700, 17900, 18100, 20000, 20500, 20600, 20900, 21100, 21200, 21300, 21600, 21800, 21900 | ||||||
---|---|---|---|---|---|---|
Design Standards eBook | Index Title | Revision | Design Information | |||
Index No | Total Sheets | Instructions for Design Stds (IDS) | Data Table Cell Library | Borderless DGNs | ||
(PDF) | (PDF) | (ZIP) | (ZIP) Terms of Use | |||
| ||||||
Complete eBook (257mb) | 934 | Year 2013 Design
2013 Design Standards eBook Effective Jan 1 - December 31 | | Combined Available IDS (10mb) | Combined Available CELs (1mb) | Combined Available DGNs (55mb) |
| COVER, TABLE OF CONTENTS AND REVISIONS | | ||||
Cover | 3 | Book Cover | | Cover | | |
Content | 2 | Table of Contents | | Content | | |
Revisions | 2 | Revision History | | Introduction | | |
Revisions | ||||||
| ABBREVIATIONS AND SYMBOLS | | ||||
001 | 4 | Standard Abbreviations | | | | |
002 | 3 | Standard Symbols | | | | |
| EROSION CONTROL AND WATER QUALITY | | ||||
104 | 2 | Permanent Erosion Control | | | | |
105 | 1 | Shoulder Sodding and Turf on Existing Facilities | | | | |
| | |||||
199 | 1 | Geotextile Criteria | | | | |
200 | 5 | Structure Bottoms - Type J & P | | | | |
201 | 5 | Supplementary Details for Manholes & Inlets | | | | |
205 | 6 | Cover Height | | | | |
206 | 2 | Trench Drain | | | | |
210 | 1 | Curb Inlet Tops - Types 1, 2, 3 & 4 | | | | |
211 | 5 | Curb Inlet Tops - Types 5 & 6 | | | | |
212 | 1 | Curb Inlet - Type 7 | | | | |
213 | 1 | Curb Inlet - Type 8 | | | | |
214 | 1 | Curb Inlet Top - Type 9 | | | | |
215 | 1 | Curb Inlet Top - Type 10 | | | | |
216 | 3 | Closed Flume Inlet | | | | |
217 | 2 | Median Barrier Inlets Types 1, 2, 3, 4 and 5 | | | | |
218 | 2 | Barrier Wall Inlet | | | | |
219 | 3 | Concrete Barrier Wall Inlet | | | | |
220 | 3 | Gutter Inlet - Type S | | | | |
221 | 2 | Gutter Inlet - Type V | | | | |
230 | 2 | Ditch Bottom Inlet - Type A | | | | |
231 | 3 | Ditch Bottom Inlet - Type B | | | | |
232 | 7 | Ditch Bottom Inlets - Types C, D, E and H | | | | |
233 | 2 | Ditch Bottom Inlets - Types F and G | | | | |
234 | 2 | Ditch Bottom Inlet - Type J | | | | |
235 | 2 | Ditch Bottom Inlet - Type K | | | | |
240 | 2 | Skimmer for Outlet Control Structures | | | | |
241 | 1 | Skimmers for Frenchdrain Outlets | | | | |
245 | 1 | Underdrain Inspection Box | | | | |
250 | 2 | Straight Concrete Endwalls - Single and Multiple Pipe | | | | |
251 | 2 | Straight Concrete Endwalls - Single and Double 60" Pipe | | | | |
252 | 2 | Straight Concrete Endwalls - Single and Double 66" Pipe | | | | |
253 | 2 | Straight Concrete Endwalls - Single and Double 72" Pipe | | | | |
255 | 1 | Straight Concrete Endwall - Single 84" Pipe | | | | |
258 | 1 | Straight Sand - Cement Endwalls | | | | |
260 | 1 | U-Type Concrete Endwalls With Grates - 15" to 30" Pipe | | | | |
261 | 3 | U-Type Concrete Endwalls - Baffles and Grate Optional - 15" to 30" Pipe | | | | |
264 | 2 | U-Type Concrete Endwall - Energy Dissipator - 30" to 72" Pipe | | | | |
266 | 1 | Winged Concrete Endwalls - Single Round Pipe | | | | |
268 | 1 | U-Type Sand-Cement Endwalls | | | | |
270 | 1 | Flared End Section | | | | |
272 | 6 | Cross Drain Mitered End Section | | | | |
273 | 7 | Side Drain Mitered End Section | | | | |
280 | 3 | Miscellaneous Drainage Details | | | | |
281 | 2 | Ditch Pavement and Sodding | | | | |
282 | 3 | Back of Sidewalk Drainage | | | | |
283 | 1 | Median Opening Flume | | | | |
284 | 1 | Concrete Shoulder Gutter Spillway | | | | |
285 | 2 | French Drain | | | | |
286 | 2 | Underdrain | | | | |
287 | 4 | Concrete Pavement Subdrainage | | | | |
288 | 1 | Deep Well Injection Box | | | | |
289 | 8 | Concrete Box Culvert Details (LRFD) | | IDS-289 | CEL-289 | DGN-289 |
291 | 5 | Supplemental Details for Precast Concrete Box Culverts | | IDS-291 | | DGN-291 |
292 | 14 | Standard Precast Concrete Box Culverts | | IDS-292 | | DGN-292 |
293 | 1 | Safety Modifications for Inlets In Box Culverts | | | | |
295 | 1 | Safety Modifications for Endwalls | | | | |
| CURBS, CONCRETE PAVEMENT & SIDEWALKS | | ||||
300 | 2 | Curb & Curb And Gutter | | | | |
301 | 1 | Turn Lanes | | | | |
302 | 4 | Traffic Separators | | IDS-302 | | |
303 | 1 | Curb Return Profiles | | | | |
304 | 6 | Public Sidewalk Curb Ramps | | | | |
305 | 4 | Concrete Pavement Joints | | | | |
306 | 1 | Bridge Approach Expansion Joint - Concrete Pavement | | | | |
307 | 3 | Miscellaneous Utility Details | | | | |
308 | 2 | Concrete Slab Replacement | | | | |
310 | 2 | Concrete Sidewalk | | | | |
| | |||||
400 | 26 | Guardrail | | | | |
402 | 24 | Guardrail Transitions and Connections for Existing Bridges | | IDS-402 | | |
403 | 3 | Guardrail Transitions for Existing Bridge Traffic Railing Retrofits | | IDS-403 | | |
410 | 25 | Concrete Barrier Wall | | | | |
411 | 10 | Pier Protection Barrier | | IDS-411 | | |
412 | 5 | Low Profile Barrier | | | | |
414 | 15 | Type K Temporary Concrete Barrier System | | IDS-414 | | |
415 | 7 | Temporary Concrete Barrier | | | | |
420 | 4 | Traffic Railing - (32" F Shape) | | IDS-420 | | DGN-420 |
421 | 4 | Traffic Railing - (Median 32" F Shape) | | IDS-421 | | DGN-421 |
422 | 3 | Traffic Railing - (42" Vertical Shape) | | IDS-422 | | DGN-422 |
423 | 3 | Traffic Railing - (32" Vertical Shape) | | IDS-423 | | DGN-423 |
424 | 7 | Traffic Railing - (Corral Shape) | | IDS-424 | | DGN-424 |
425 | 3 | Traffic Railing - (42" F Shape) | | IDS-425 | | DGN-425 |
430 | 2 | Crash Cushion Details | R2013-05 | IDS-430 | | |
461 | 1 | Opaque Visual Barrier | | | | |
470 | 3 | Traffic Railing - (Thrie Beam Retrofit) General Notes & Details | | IDS-470 | | DGN-470 |
471 | 4 | Traffic Railing - (Thrie Beam Retrofit) Narrow Curb | | | DGN-471 | |
472 | 4 | Traffic Railing - (Thrie Beam Retrofit) Wide Strong Curb Type 1 | | | DGN-472 | |
473 | 4 | Traffic Railing - (Thrie Beam Retrofit) Wide Strong Curb Type 2 | | | DGN-473 | |
474 | 4 | Traffic Railing - (Thrie Beam Retrofit) Intermediate Curb | | | DGN-474 | |
475 | 4 | Traffic Railing - (Thrie Beam Retrofit) Wide Curb Type 1 | | | DGN-475 | |
476 | 4 | Traffic Railing - (Thrie Beam Retrofit) Wide Curb Type 2 | | | DGN-476 | |
480 | 2 | Traffic Railing - (Vertical Face Retrofit) General Notes & Details | | IDS-480 | | DGN-480 |
481 | 3 | Traffic Railing - (Vertical Face Retrofit) Narrow Curb | | | DGN-481 | |
482 | 4 | Traffic Railing - (Vertical Face Retrofit) Wide Curb | | | DGN-482 | |
483 | 3 | Traffic Railing - (Vertical Face Retrofit) Intermediate Curb | | | DGN-483 | |
484 | 10 | Traffic Railing - (Vertical Face Retrofit) Spread Footing Approach | | | DGN-484 | |
| | |||||
500 | 2 | Removal of Organic and Plastic Material | | | | |
501 | 12 | Geosynthetic Reinforced Soils | | IDS-501 | | DGN-501 |
505 | 4 | Embankment Utilization | | | | |
506 | 1 | Miscellaneous Earthwork Details | | | | |
510 | 2 | Superelevation - Rural Highways, Urban Freeways and High Speed Urban Highways | | | | |
511 | 3 | Superelevation - Urban Highways and Streets | | | | |
514 | 2 | Optional Base Group and Structural Numbers | | | | |
515 | 7 | Turnouts | | | | |
516 | 1 | Turnouts - Resurfacing Projects | | | | |
518 | 3 | Rumble Strips | | | | |
521 | 1 | Concrete Steps | | IDS-521 | | |
525 | 5 | Ramp Terminals | | | | |
526 | 8 | Roadway Transitions | | | | |
527 | 3 | Directional Median Openings | | | | |
530 | 3 | Rest Area Pavilion | | | | |
532 | 3 | Mailboxes | | | | |
535 | 1 | Tractor Crossings | | | | |
540 | 1 | Settlement Plate | | | | DGN-540 |
544 | 3 | Landscape Installation | | | | |
546 | 6 | Sight Distance at Intersections | | | | |
560 | 2 | Railroad Crossings | | | | |
591 | 1 | Landscape Irrigation Sleeves | | | | |
| TRAFFIC CONTROL THROUGH WORK ZONES | | ||||
600 | 13 | General Information for Traffic Control Through Work Zones | | | | |
601 | 1 | Two-Lane, Two-Way, Work Outside Shoulder | | | | |
602 | 1 | Two-Lane, Two-Way, Work on Shoulder | | | | |
603 | 2 | Two-Lane, Two-Way, Work Within the Travel Way | | | | |
604 | 1 | Two-Lane, Two-Way, Work in intersection | | | | |
605 | 1 | Two-Lane, Two-Way, Work Near Intersection | | | | |
606 | 4 | Two-Lane, Two-Way, Work Within the Travel Way - Signal Control | | | | |
607 | 1 | Two-Lane, Two-Way, Mobile Operation, Work on Shoulder, Work Within the Travel Way | | | | |
608 | 1 | Two-Lane, Two-Way, Temporary Diversion Connection | | | | |
611 | 1 | Multilane, Work Outside Shoulder | | | | |
612 | 1 | Multilane, Work on Shoulder | | | | |
613 | 2 | Multilane, Work Within the Travel Way - Median or Outside Lane | | | | |
614 | 2 | Multilane, Work Within the Travel Way - Center Lane | | | | |
615 | 1 | Multilane, Work in Intersection | | | | |
616 | 3 | Multilane, Work Near Intersection - Median or Outside Lane | | | | |
617 | 1 | Multilane, Work in Intersection - Center Lane | | | | |
618 | 1 | Multilane, Work in Intersection - Two Lanes Closed - 45 mph or Less | | | | |
619 | 2 | Multilane, Mobile Operations, Work on Shoulder, Work Within the Travel Way | | | | |
620 | 2 | Multilane, Divided, Temporary Diversion Connection | | | | |
621 | 1 | Multilane, Undivided, Temporary Diversion Connection | | | | |
622 | 1 | Multilane, Work Near Intersection-Temporary Diversion Connection-35 mph or Less | | | | |
623 | 1 | Multilane, Work Within the Travel Way Double Lane Closure | | | | |
625 | 1 | Temporary Road Closure - 5 Minutes or Less | | | | |
628 | 1 | Two-Way Left Turn Lane Closure | | | | |
630 | 2 | Crossover for Paving Train Operations, Rural | | | | |
631 | 2 | Temporary Crossover | | | | |
635 | 1 | Work in Vicinity of Railroad Crossing | | | | |
640 | 2 | Converting Two-Lanes to Four-Lanes Divided, Rural | | | | |
641 | 3 | Converting Two-Lanes to Four-Lanes Divided, Urban | | | | |
642 | 1 | Transitions for Temporary Concrete Barrier Wall on Freeway Facilities | | | | |
650 | 2 | Two-Lane, Two-Way Rural Structure Replacement | | | | |
651 | 2 | Multilane, Divided, Maintenance and Construction | | | | |
655 | 3 | Traffic Pacing | | | | |
660 | 1 | Pedestrian Control for Closure of Sidewalks | | | | |
665 | 1 | Limited Access, Temporary Opening | | | | |
667 | 6 | Toll Plaza, Traffic Control Standards | | | | |
670 | 1 | Motorist Awareness System | | | | |
| | |||||
700 | 2 | Roadside Offsets | | | | |
| | |||||
800 | 2 | Fence Location | | | | |
801 | 3 | Fence - Type A | | | | |
802 | 3 | Fence - Type B | | | | |
803 | 1 | Cantilever Slide Gate - Type B Fence | | | | |
810 | 4 | Bridge Fencing (Vertical) | | IDS-810 | | DGN-810 |
811 | 3 | Bridge Fencing (Curved Top) | | IDS-811 | | DGN-811 |
812 | 4 | Bridge Fencing (Enclosed) | | IDS-812 | | DGN-812 |
820 | 1 | Bridge Pedestrian/Bicycle Bullet Railing | | IDS-820 | | DGN-820 |
821 | 1 | Bridge Aluminum Pedestrian/Bicycle Bullet Railing for Traffic Railing (32" F Shape) | | IDS-821 | | DGN-821 |
822 | 3 | Bridge Aluminum Pedestrian/Bicycle Bullet Railing Details | | IDS-822 | | DGN-822 |
825 | 1 | 42" Concrete Pedestrian/Bicycle Railing | | IDS-825 | | DGN-825 |
851 | 3 | Bridge Pedestrian/Bicycle Railing (Steel) | | IDS-851 | | DGN-851 |
852 | 8 | Steel Pedestrian/Bicycle Railing | | IDS-852 | CEL-852 | DGN-852 |
861 | 3 | Bridge Pedestrian/Bicycle Railing (Aluminum) | | IDS-861 | | DGN-861 |
862 | 8 | Aluminum Pedestrian/Bicycle Railing | | IDS-862 | CEL-862 | DGN-862 |
870 | 5 | Aluminum Pipe Guiderail | | IDS-870 | | |
880 | 5 | Steel Pipe Guiderail | | IDS-880 | | |
| | |||||
5200 | 16 | Precast Sound Barriers | | IDS-5200 | CEL-5200 | DGN-5200 |
5210 | 5 | Traffic Railing/Sound Barrier (8'-0") | | IDS-5210 | | DGN-5210 |
5211 | 3 | Traffic Railing/Sound Barrier (14'-0") | | IDS-5211 | | DGN-5211 |
5212 | 2 | Traffic Railing/Sound Barrier (8'-0") Junction Slab | | IDS-5212 | | DGN-5212 |
5213 | 2 | Traffic Railing/Sound Barrier T-Shape Spread Footing | | IDS-5213 | | DGN-5213 |
5214 | 4 | Traffic Railing/Sound Barrier L-Shaped Spread Footing | | IDS-5214 | | DGN-5214 |
5215 | 1 | Traffic Railing/Sound Barrier Trench Footing | | IDS-5215 | | DGN-5215 |
| | |||||
6010 | 2 | C-I-P Cantilever Retaining Wall | | IDS-6010 | CEL-6010 | DGN-6010 |
6011 | 1 | C-I-P Gravity Wall | | IDS-6011 | | DGN-6011 |
6020 | 1 | Permanent MSE Retaining Wall Systems | | IDS-6020 | CEL-6020 | DGN-6020 |
6030 | 1 | Temporary MSE Retaining Wall Systems | | IDS-6030 | CEL-6030 | DGN-6030 |
6040 | 4 | Precast Concrete Sheet Pile Wall | | IDS-6040 | CEL-6040-CSPDA | DGN-6040 |
6100 | 2 | MSE Wall Coping (Precast or C-I-P) | | IDS-6100 | | DGN-6100 |
6110 | 6 | Wall Coping With Traffic Railing/Junction Slab | | | DGN-6110 | |
6120 | 3 | Wall Coping With Traffic Railing/Raised Sidewalk | | | DGN-6120 | |
6130 | 2 | Wall Coping/Parapet With C-I-P Sidewalk | | | DGN-6130 | |
6200 | 3 | Coping Mounted Light Pole Pedestal | | | | DGN-6200 |
6201 | 1 | Junction Slab at Drainage Inlet Openings | | | | DGN-6201 |
| | |||||
11200 | 2 | Multi-Column Ground Sign | | IDS-11200 | | |
11300 | 1 | Steel Overhead Sign Structures | | | | |
11310 | 5 | Cantilever Sign Structure | | IDS-11310 | CEL-11310 | |
11320 | 5 | Span Sign Structure | | IDS-11320 | CEL-11320 | |
11860 | 8 | Single Column Ground Signs | | IDS-11860 | | |
11870 | 2 | Single Post Bridge Mounted Sign Support | | IDS-11870 | | DGN-11870 |
11871 | 2 | Single Post Median Barrier Mounted Sign Support | R2013-01 | IDS-11871 | | |
13417 | 1 | Mounting Exit Number Panels to Highway Signs | | | | |
17302 | 1 | Typical Sections for Placement of Single & Multi-Column Signs | | | | |
17328 | 2 | Typical Signing for Truck Weigh and Inspection Stations | | | | |
17344 | 6 | School Signs & Markings | | | | |
17345 | 4 | Interchange Markings | R2013-02 | | | |
17346 | 14 | Special Marking Areas | R2013-02 | | | |
17347 | 4 | Bicycle Markings | | | | |
17349 | 1 | Traffic Controls for Street Terminations | | | | |
17350 | 1 | Signing for Motorist Services | | | | |
17351 | 2 | Welcome Center Signing | | | | |
17352 | 2 | Typical Placement of Reflective Pavement Markers | | | | |
17354 | 1 | Tourist Oriented Directional Signs | | | | |
17355 | 11 | Special Sign Details | | | | |
17356 | 1 | Span Wire Mounted Sign Details | | | | |
17357 | 1 | Bridge Weight Restrictions | | | | |
17359 | 2 | Rural Narrow Bridge Treatment | | | | |
| | |||||
17500 | 3 | Conventional Lighting | | | | |
17501 | 1 | Highway Lighting General Notes | | | | |
17502 | 6 | Highmast Lighting | | IDS-17502 | | |
17504 | 1 | Service Point Details | | | | |
17505 | 2 | External Lighting for Signs | | | | |
17515 | 8 | Standard Aluminum Lighting | | IDS-17515 | | |
| | |||||
17600 | 3 | Motorist Aid Call Box | | | | |
17700 | 1 | Pull, Splice and Junction Box | | | | |
17721 | 2 | Conduit Installation Details | | | | |
17723 | 3 | Steel Strain Pole | | IDS-17723 | | |
17725 | 8 | Concrete Poles | | IDS-17725 | | |
17727 | 2 | Signal Cable and Span Wire Installation Details | R2013-03 | | | |
17733 | 1 | Aerial Interconnect | | | | |
17736 | 1 | Electric Power Service | | | | |
17743 | 2 | Standard Mast Arm Assemblies | | IDS-17743 | CEL-17743 | |
17745 | 5 | Mast Arm Assemblies | | IDS-17745 | CEL-17745 | |
17748 | 1 | Free-Swinging, Internally-Illuminated Street Sign Assemblies | | | | |
17764 | 1 | Pedestrian Control Signal Installation Details | | | | |
17781 | 2 | Vehicle Loop Installation Details | | | | |
17784 | 2 | Pedestrian Detector Assembly Installation Details | | | | |
17841 | 1 | Cabinet Installation Details | | | | |
17870 | 2 | Standard Signal Operating Plans | | | | |
17881 | 1 | Advance Warning for R/R Crossing | | | | |
17882 | 4 | Railroad Grade Crossing Traffic Control Devices | | | | |
17890 | 3 | Traffic Control Devices for Movable Span Bridge Signals | | | | |
| | |||||
17900 | 7 | Traffic Monitoring Site | | | | |
| INTELLIGENT TRANSPORTATION SYSTEMS | | ||||
18100 | 1 | CCTV Pole Placement | | | | |
18101 | 1 | Typical CCTV Site | | | | |
18102 | 2 | CCTV Pole Grounding | | | | |
18104 | 1 | Typical CCTV Cabinet Equipment Layout | | | | |
18105 | 1 | CCTV Block Diagram | | | | |
18107 | 1 | Ground Mounted CCTV Cabinet | | | | |
18108 | 1 | Pole Mounted CCTV Cabinet | | | | |
18110 | 2 | Camera Mounting Details | | | | |
18111 | 2 | Steel CCTV Pole | | | | |
18113 | 2 | Concrete CCTV Pole | | | | |
18202 | 1 | Fiber Optic Trench Details | | | | |
18300 | 10 | Dynamic Message Sign Walk-In | | | | |
| | |||||
20005 | 1 | Prestressed I-Beam Temporary Bracing | | IDS-20005 | CEL-20005 | DGN-20005 |
20010 | 2 | Typical Florida I-Beam Details and Notes | | IDS-20010 | CEL-20010 | DGN-20010 |
20036 | 2 | Florida-I 36 Beam - Standard Details | | DGN-20036 | ||
20045 | 2 | Florida-I 45 Beam - Standard Details | | DGN-20045 | ||
20054 | 2 | Florida-I 54 Beam - Standard Details | | DGN-20054 | ||
20063 | 2 | Florida-I 63 Beam - Standard Details | | DGN-20063 | ||
20072 | 2 | Florida-I 72 Beam - Standard Details | | DGN-20072 | ||
20078 | 2 | Florida-I 78 Beam - Standard Details | | DGN-20078 | ||
20084 | 2 | Florida-I 84 Beam - Standard Details | | DGN-20084 | ||
20096 | 2 | Florida-I 96 Beam - Standard Details | | DGN-20096 | ||
20199 | 1 | Build-Up & Deflection Data for Florida-I Beams | | IDS-20199 | CEL-20199 | DGN-20199 |
20210 | 2 | Typical Florida U Beam Details and Notes | | IDS-20210 | CEL-20210 | DGN-20210 |
20248 | 3 | Florida U 48 Beam - Standard Details | | DGN-20248 | ||
20254 | 3 | Florida U 54 Beam - Standard Details | | DGN-20254 | ||
20263 | 3 | Florida U 63 Beam - Standard Details | | DGN-20263 | ||
20272 | 3 | Florida U 72 Beam - Standard Details | | DGN-20272 | ||
20299 | 1 | Build-up and Deflection Data for Florida U Beams | | IDS-20299 | CEL-20299 | DGN-20299 |
| | |||||
20502 | 1 | Beveled Bearing Plate Details - Prestressed Florida U-Beams | | IDS-20502 | CEL-20502 | DGN-20502 |
20510 | 1 | Composite Elastomeric Bearing Pads - Prestressed Florida-I Beams | | IDS-20510 | CEL-20510 | DGN-20510 |
20511 | 2 | Bearing Plates (Type I) - Prestressed Florida-I Beams | | IDS-20511 | CEL-20511 | DGN-20511 |
20512 | 2 | Bearing Plates (Type 2) - Prestressed Florida-I Beams | | IDS-20512 | CEL-20512 | DGN-20512 |
| ||||||
20600 | 1 | Notes and Details for Square Prestressed Concrete Piles | | IDS-20600 | CEL-20600 | DGN-20600 |
20601 | 1 | Square Prestressed Concrete Pile Splices | | DGN-20601 | ||
20602 | 1 | EDC Instrumentation for Square Prestressed Concrete Piles | | DGN-20602 | ||
20612 | 1 | 12'' Square Prestressed Concrete Pile | | DGN-20612 | ||
20614 | 1 | 14'' Square Prestressed Concrete Pile | | DGN-20614 | ||
20618 | 1 | 18'' Square Prestressed Concrete Pile | | DGN-20618 | ||
20620 | 1 | 20'' Square Prestressed Concrete Pile | | DGN-20620 | ||
20624 | 1 | 24'' Square Prestressed Concrete Pile | | DGN-20624 | ||
20630 | 1 | 30'' Square Prestressed Concrete Pile | | DGN-20630 | ||
20631 | 1 | High Moment Capacity 30'' Square Prestressed Concrete Pile | | DGN-20631 | ||
20654 | 2 | 54'' Precast/Post-Tensioned Concrete Cylinder Pile | | IDS-20654 | DGN-20654 | |
20660 | 2 | 60'' Prestressed Concrete Cylinder Pile | | IDS-20660 | DGN-20660 | |
| | |||||
20900 | 2 | Approach Slabs (Flexible Pavement Approaches) | | IDS-20900 | CEL-20900 | DGN-20900 |
20910 | 2 | Approach Slabs (Rigid Pavement Approaches) | | IDS-20910 | CEL-20910 | DGN-20910 |
| | |||||
21100 | 3 | Strip Seal Expansion Joint | | IDS-21100 | CEL-21100 | DGN-21100 |
21110 | 2 | Poured Joint With Backer Rod Expansion Joint System | | IDS-21110 | CEL-21110 | DGN-21110 |
| | |||||
21200 | 3 | Light Pole Pedestal | | IDS-21200 | | DGN-21200 |
21210 | 2 | Conduit Details | | IDS-21210 | | DGN-21210 |
21220 | 2 | Navigation Light System Details (Fixed Bridges) | | IDS-21220 | | DGN-21220 |
21240 | 2 | Maintenance Lighting for Box Girders | | IDS-21240 | | DGN-21240 |
21250 | 1 | Access Hatch Assembly for Steel Box Sections | | IDS-21250 | | DGN-21250 |
21251 | 1 | Access Hatch Assembly for Concrete Box Sections | | | DGN-21251 | |
| | |||||
21300 | 1 | Standard Bar Bending Details | | IDS-21300 | | DGN-21300 |
| | |||||
21600 | 7 | Temporary Detour Bridge General Notes and Details | | IDS-21600 | | DGN-21600 |
21610 | 3 | Temporary Detour Bridge Details -Timber Pile Foundations | | | DGN-21610 | |
21620 | 2 | Temporary Detour Bridge Details -Steel H Pile Foundations | | | DGN-21620 | |
21630 | 3 | Temporary Detour Bridge Details -Steel Pipe Pile Foundations | | | DGN-21630 | |
| | |||||
21801 | 2 | Post-Tensioning Vertical Profiles | | IDS-21800 | CEL-21800b | DGN-21801 |
21802 | 1 | Post-Tensioning Anchorage Protection | | DGN-21802 | ||
21803 | 3 | Post-Tensioning Anchorage and Grouting Details | | DGN-21803 | ||
| | |||||
21900 | 7 | Fender System- Polymeric Piles | | IDS-21900 | CEL-21900 | DGN-21900 |