2219 search results for bridge inspection

ScopeOfServices_StageII

/A) ....................................................................................................................................................... 42 10 STRUCTURES - BRIDGE, BRIDGE (N/A).................................................................. 42 12 STRUCTURES - SHORT SPAN CONCRETE BRIDGE (N/A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 13 STRUCTURES - MEDIUM SPAN CONCRETE BRIDGE (N/A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 14 STRUCTURES - STRUCTURAL STEEL BRIDGE (N

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/procuement_marketingd1/documents/fy24-25/ad--25112/scopeofservices_stageii.pdf?sfvrsn=81019660_1

Chapter5s8Redline

References Standard Specifications for Road and Bridge Construction Federal-Aid Policy Guide, 23 Code, methods of material acceptance: 1) certification; 2) visual inspection; and 3) sampling and testing, into Witness-and-Hold projects. Visual Inspection may also be an alternate method of acceptance

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/manuals/cpam/newhistory/chapter5s8redline.pdf?sfvrsn=b76cc5c0_9

SS5610000

Inspection: Meet the requirements of 560-5.3. 561-5 Qualifications. 561-5.1 Field Contractor: Meet, and sealed by a Contractor’s Engineer of Record qualified in Type Work Category 4.3, Complex Bridge, for inspection. All drawings and calculations must be submitted and accepted before any work begins. Include

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2011/january-2011/workbook/ss5610000.pdf?sfvrsn=c43fcaa8_0

SS5610000

Inspection: Meet the requirements of 560-5.3. 561-5 Qualifications. 561-5.1 Field Contractor: Meet, and sealed by a Contractor’s Engineer of Record qualified in Type Work Category 4.3, Complex Bridge, for inspection. All drawings and calculations must be submitted and accepted before any work begins. Include

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2012/january-2012/workbook/ss5610000.pdf?sfvrsn=739e295e_0

SS1040000

an appreciable number of stream crossings are necessary at any one location, use a temporary bridge or other, is required, the Engineer will base acceptance on visual inspection. The Contractor may use new or used, by the Engineer. 104-6.4.6.3 Inspection and Maintenance: Inspect all silt fences immediately after each

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2012/january-2012/workbook/ss1040000.pdf?sfvrsn=474755c0_0

section115-012012

Officials (AASHTO)/AWS D1.5, Bridge Welding Code American Welding Society (AWS) D1.1/D1.1M, inspection/testing of steel and other miscellaneous metal products. 11.5.5 GENERAL INFORMATION, to the FDOT inspection agency. Topic No.: 675-000-000 Materials Manual Effective: January 20, 2012

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2012/january-2012/materials-manual/section115-012012.pdf?sfvrsn=26b840fd_1

Chapter11s5

Operations, Part 637 - Construction Inspection and Approval Section 330, Standard Specifications for Road and Bridge Construction 11.5.4 General The FDOT's intent is for the friction course, of Construction, Form No. 700-010-13, will reflect this inspection. (3) After each s traightedging

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/manuals/cpam/newcleanchapters/chapter11s5.pdf?sfvrsn=856d0be9_8

Material Manual

mix designs, and inspection and testing of production concrete. Obtain SCC, of the concrete mixes, and inspection and testing of production concrete, Testing on Florida Department of Transportation structural steel bridge

https://www.fdot.gov/specifications/material-manual

4550701.FHWA

of fill. 14. Provide the make and model of the shaft inspection device, if applicable. 15. Details, Inspection Device (SID): When shown in the Plans, furnish all power and equipment necessary, of the excavation. Include all cost related to the inspection device in the cost of drilled shaft items, camera sealed inside a watertight bell housing. 2. Provides a clear view of the bottom inspection, inspection with voice annotation on a quality DVD with a resolution of not less than 720 x 480

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2019/january-2019/review/fhwa/4550701.fhwa.pdf?sfvrsn=19f4c507_0

CAV Guidance LL&BP_2026 Edition

 Florida Design Manual (FDM), latest version  FDOT Standard Plans for Road and Bridge Construction, latest version  FDOT Standard Specifications for Road and Bridge Construction, latest version, CAV Connected and Autonomous Vehicles CEI Construction, Engineering, Inspection CFP Cost, is the bridge between planning, programming, and the Systems Engineering Analysis required for implementation

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/traffic/cav-guidance-ll-bp_2026-edition.pdf?sfvrsn=f72b3f7_1

E8U74

Contract Days: 1693 Total Bridge Length: 0.000 Miles Letting Date: 05/10/24 Total Proposal Length, 0107- 2- MOWING AC 7,509.520 0108- 1- MONITOR EXISTING STRUCTURES- INSPECTION AND SETTLEMENT MONITORING (44622315201) LS 1.000 0108- 1- MONITOR EXISTING STRUCTURES- INSPECTION AND SETTLEMENT, 0400- 4- 5 CONCRETE CLASS IV, BRIDGE SUBSTRUCTURE CY 1.500 0400- 4- 8 CONC CLASS IV, BULKHEAD CY, - 4-640 OVERHEAD STATIC SIGN STRUCTURE, REMOVE BRIDGE MOUNT EA 2.000 0700- 13- 12 RETROREFLECTIVE

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/tp/lettings/2024/may10/e8u74.pdf?sfvrsn=e5a90fae_1

D0090000.do

at all times. 9-1.6 Ladders and Instrument Stands for Bridge Projects: On bridge projects, in order, of the project, (except materials exempted by 9-6.2), preserve for the Department’s inspection the invoices, the work provided for under the Contract and the Engineer has performed a final inspection and made, and bridge is less than $1,000,000. 9-9 Interest Due on Delayed Payments. TheDepartment

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2003/january-2003/workbook/d0090000.do.pdf?sfvrsn=564555a9_0

D0090000.DO

at all times. 9-1.6 Ladders and Instrument Stands for Bridge Projects: On bridge projects, in order, of the project, (except materials exempted by 9-6.2), preserve for the Department’s inspection the invoices, the work provided for under the Contract and the Engineer has performed a final inspection and made, and bridge is less than $1,000,000. 9-9 Interest Due on Delayed Payments. TheDepartment

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2003/january-2003/workbook/d0090000.do3616fd0a27c84a5f8ecccbf624a699e9.pdf?sfvrsn=2733a76b_0

TP-05-02-25BSN

in accordance with Article 3-1 of the Standard Specifications for Road and Bridge Construction, Standard Specifications for Road and Bridge Construction. Insurance companies must be authorized, Specifications for Road and Bridge Construction and the Special Provisions for instructions, ): 44089735201(*) Federal Aid No: N/A Total Roadway Length: 3.000 Miles Contract Days: 1669 Total Bridge, Quantity Section 0001 Structures 0400- 2- 4 CONC CLASS II, BRIDGE SUPERSTRUCTURE CY 5,478.300 0400- 2

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/tp/lettings/2025/may02/tp-05-02-25bsn.pdf?sfvrsn=a7e81972_1

Special Provisions Workbook July 2018

INSPECTION REQUIREMENTS - COOPERATION BY THE CONTRACTOR. (REV 2-10-94) (7-18) Changes to: 5-9.1 SP0050901 Long bridge jobs (1500 feet or longer); modify to suit. CONTROL OF MATERIALS

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/july-2018/workbook/special-provisions-workbook-july-2018.pdf?sfvrsn=a36b737b_1

FMTP24_TM2_Conditions_Performance

Linder International Airport MPO Metropolitan Planning Organization NBI National Bridge Inspection, Bridge Conditions, ...........................................................................................................................13 Table 5 | FHWA NHS Bridge, measures required by the Federal Highway Administration (FHWA), such as bridge and pavement conditions, Planning Time Index • Truck Bottlenecks • Highway Pavement Conditions • Bridge Conditions

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/rail/plans/fmtp/fmtp24/fmtp24_tm2_conditions_performance.pdf?sfvrsn=309c826a_4

4550201-724IMPLrev

the piles to facilitate inspection. Provide individual straight-line marks at 1-ft intervals legibly, Pile Inspection Device : Provide a pile inspection device that displays and stores electronically, Record form. Use this device during the inspection of test piles and production piles. SUBARTICLE, tested concrete piles in accordance with 455-5.14 will not require inspection during handling. Keep, as all the piles within one bent or pile footing for a specific bridge for each phase of construction

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/implemented/4550201-724implrev.pdf?sfvrsn=ca68c24e_1

4550201-724IMPL

the piles to facilitate inspection. Provide individual straight-line marks at 1-ft intervals legibly, Pile Inspection Device : Provide a pile inspection device that displays and stores electronically, Driving Record form. Use this device during the inspection of test piles and production piles, tested concrete piles in accordance with 455-5.14 will not require inspection during handling. Keep, as all the piles within one bent or pile footing for a specific bridge for each phase

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/implemented/4550201-724impl.pdf?sfvrsn=5be8e41b_1
20 of 2219 results