SP4570000

. 457-2.1 Stay-In-Place Forms: Use forms composed of a durable, inert, corrosion resistant material, in place around the pile. Fabricate the forms from fiberglass and polyester resins, having, inhibiting agents in contact with the filler material. Provide the forms with bonded or bolted-on, non-corrosive standoffs to maintain the forms in the required positions. Sandblast or score the inside surface of the forms with an abrasive material to provide a rough surface texture. Equip

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2012/january-2012/workbook/sp4570000.pdf?sfvrsn=c1be79db_0

SP4570000

. 457-2.1 Stay-In-Place Forms: Use forms composed of a durable, inert, corrosion resistant material, in place around the pile. Fabricate the forms from fiberglass and polyester resins, having, with the filler material. Provide the forms with bonded or bolted-on, non-metallic standoffs to maintain the forms in the required positions. Sandblast or score the inside surface of the forms with an abrasive material to provide a rough surface texture. Equip the forms with a compressible sealing strip

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2013/january-2013/workbook/sp4570000.pdf?sfvrsn=bd2325cb_0

SP4570000

. 457-2.1 Stay-In-Place Forms: Use forms composed of a durable, inert, corrosion resistant, and sealed in place around the pile. Fabricate the forms from fiberglass and polyester resins, having, with the filler material. Provide the forms with bonded or bolted-on, non-metallic standoffs to maintain the forms in the required positions. Sandblast or score the inside surface of the forms with an abrasive material to provide a rough surface texture. Equip the forms with a compressible sealing strip

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/january-2014/workbook/sp4570000.pdf?sfvrsn=49dbe5e2_0

Claims

Statement. Please allow extra time for manual processing. Links to these forms are provided below. Claims, the form and other documents to dotclaims.review@dot.state.fl.us Forms Lien Disclosure

https://www.fdot.gov/legal/claims/claimshomepage.shtm

Utilities

is to develop and maintain rules, policies, procedures, forms and agreements for utility accommodation, Training Modules UAM Archives Utility Forms UAO/FDOT Utility Agreements Buy America Guidance

https://www.fdot.gov/programmanagement/utilities/default.shtm

Post-WWII Survey and Evaluation Methodology

forms and receive evaluations. If significant under Criteria A or B, the remaining structures, the APE are NOT individually recorded nor evaluated on FMSF forms. FDOT Procedure IF the Resource, forms for the appropriate resources per methods chosen • Conduct survey in accordance with the methodologies for Post-WWII residential structures • Evaluate resources recorded on FMSF forms • Determine the need (or not) for additional FMSF forms based on methodology • Apply criteria of adverse

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/environment/pubs/cultural-resources/post-wwii-survey-and-evaluation-methodology.pdf?sfvrsn=b9f665ca_2

6110402-724IMPL

FDOT forms, evaluate ITS devices as per Contract Documents and as approved by the Engineer. Complete approved data forms and turn them over to the Engineer for approval. Provide a minimum notice

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/implemented/6110402-724impl.pdf?sfvrsn=5e8d6feb_1

9320501-724origind

- incomplete forms will be returned) Design Bulletin Construction (DCE Memo) EstimatesBulletin, polymer Pproducts may come inbe formulated in powder, granular or liquid forms. Products and shall

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/internal/9320501-724origind.pdf?sfvrsn=82d8373c_2

D4000000.do

and deflection of falsework. Give bridges permanent camber only when shown in the plans. 400-5 Forms, the neat lines, contours, and shapes shown in the plans. Design forms to withstand the additional forces of vibration without apparent deviation from the desired shape or position. Assemble forms to be mortar-tight. If using lumber forms, construct them of dressed wood of uniform thickness. Use form liners on wooden forms where Class 3 surface finish is specified. Construct assembled forms

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2003/january-2003/workbook/d4000000.doea4bb3f151dd46a8830de389a3d5532a.pdf?sfvrsn=670d9459_0

D4570001.DO

forms composed of a durable, inert, corrosion resistant material with an interlocking joint along, the forms from fiberglass and polyester resins, having a minimum thickness of 1/8 inch [3 mm] unless, inhibiting agents in contact with the cementitious or epoxy grouts. Provide the forms with bonded-on, non-corrosive standoffs, which will maintain the forms in the required positions. Sandblast or score the inside surface of the forms with an abrasive material to provide a texture equal to a sandblasted

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2003/january-2003/workbook/d4570001.do.pdf?sfvrsn=ed8037ad_0

D0050085.do

forms provided by the Engineer, summarize the daily quality control program activities including testing and material sampling activities. Make copies of the completed forms available

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2003/january-2003/workbook/d0050085.do.pdf?sfvrsn=6bd5f867_0

D4570001.DO

forms composed of a durable, inert, corrosion resistant material with an interlocking joint along, the forms from fiberglass and polyester resins, having a minimum thickness of 1/8 inch [3 mm] unless, inhibiting agents in contact with the cementitious or epoxy grouts. Provide the forms with bonded-on, non-corrosive standoffs, which will maintain the forms in the required positions. Sandblast or score the inside surface of the forms with an abrasive material to provide a texture equal to a sandblasted

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2004/january-2004/workbook/d4570001.do.pdf?sfvrsn=70e8098d_0

7140000SS

Construction of Concrete Pads. 714-3.1 Forms: Provide forms as specified in 520-3. 714-3.2 Foundations

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2005/january-2005/workbook/7140000ss.pdf?sfvrsn=8d67eff0_0

4001604.comm

 4001604 CONCRETE STRUCTURES COMMENTS FROM INTERNAL/INDUSTRY REVIEW Ghulam Mujtaba 352- 955-6685 ghulam.mujtaba@dot.state.fl.us Comments: (5-27-15) 1. On the first paragraph, change 'the entire top surface" to "top surface of the entire placed concrete". Response: 2- Change "Bridge deck bottom and side forms may be removed after 72 hours in compliance with 400-14." to "Bridge deck bottom and side forms may be removed after 72- hour curing, provided that concrete meets

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/january-2016/review/comments-responses/4001604.comm.pdf?sfvrsn=343cbbcc_0