4318 search results for fdot standard plans
SPI-415-001
Standard Plans Instructions Topic No. 625-010-003 Index 415-001 Standard Bar Bending Details (Steel) FY 2025-26 1 Index 415-001 Standard Bar Bending Details (Steel) Design Criteria AASHTO, . This standard works with the REINFORCING BAR LIST that must be completed and included in the plans, information and guidance see the Specifications, Standard Plans and/or Standard Plans Instructions, to Standard Plans Index 415-001 on the REINFORCING BAR LIST sheets. Payment Item number Item
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/spi/spi-415-001.pdf?sfvrsn=b7fc7516_1SPI-415-001
Standard Plans Instructions Topic No. 625-010-003 Index 415-001 Standard Bar Bending Details (Steel) FY 2026-27 1 Index 415-001 Standard Bar Bending Details (Steel) Design Criteria AASHTO, . This standard works with the REINFORCING BAR LIST that must be completed and included in the plans, information and guidance see the Specifications, Standard Plans and/or Standard Plans Instructions, to Standard Plans Index 415-001 on the REINFORCING BAR LIST sheets. Payment Item number Item
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2027/spi/spi-415-001.pdf?sfvrsn=70ca4f04_1654-001-IndustryReviewResponse
Industry Review Comments and Responses FDOT – Standard Plans 1 Index 654-001 Rectangular Rapid Flashing Beacon Assembly ORIGINATION Date: 7/7/25 Name: Dibakar Saha Phone: (850)410-5417, of W11-2 sign panel, a note 13 was added to send the user to Standard Plans Index 700-010 for the appropriate dimensions. COMMENTS AND RESPONSES BLACK = Industry Review Comments BLUE = Standard Plans, 654-001 - Recommend the proposed Note 13, "See Standard Plans Index 700-010 for sign dimensions" replace
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/irr/2027/654-001-industryreviewresponse.pdf?sfvrsn=b70fdc6a_1546-020-IndustryReviewResponse
Industry Review Comments and Responses FDOT – Standard Plans 1 Index 546-020 Ground-In Rumble, width shoulders. Industry Review Comments and Responses FDOT – Standard Plans 2 RESPONSE: Thanks, /No) Other Standard Plans No FDOT Design Manual No Standard Specifications No Basis of Estimates Manual, or greater. COMMENTS AND RESPONSES BLACK = Industry Review Comments BLUE = Standard Plans Response, 50 mph or greater. The change to Standard Plans Index 711-001 in relation, will not move forward
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/irr/2026/546-020-industryreviewresponse.pdf?sfvrsn=36b9f51f_1460-475-IndustryReviewResponse
Industry Review Comments and Responses FDOT – Standard Plans 1 Index 460-475 Traffic Railing - (Thrie-Beam Retrofit) Wide Curb Type 1 ORIGINATION Date: 5/15/24 Name: Joshua Turley Phone: 414-4475 Email: Joshua.turley@dot.state.fl.us COMMENTARY We have recently finished research into screw anchors and are now allowing them as an option on this Standard and we needed to add a note, . COMMENTS AND RESPONSES BLACK = Industry Review Comments BLUE = Standard Plans Response GREEN
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/irr/2026/460-475-industryreviewresponse.pdf?sfvrsn=28e11884_1460-473-IndustryReviewResponse
Industry Review Comments and Responses FDOT – Standard Plans 1 Index 460-473 Traffic Railing - (Thrie-Beam Retrofit) Wide Strong Curb Type 2 ORIGINATION Date: 5/15/24 Name: Joshua Turley Phone: 414-4475 Email: Joshua.turley@dot.state.fl.us COMMENTARY Sheet 2, 4: We have recently finished research into screw anchors and are now allowing them as an option on this Standard and we, is the only option. COMMENTS AND RESPONSES BLACK = Industry Review Comments BLUE = Standard Plans
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/irr/2026/460-473-industryreviewresponse.pdf?sfvrsn=777a727b_1460-474-IndustryReviewResponse
Industry Review Comments and Responses FDOT – Standard Plans 1 Index 460-474 Traffic Railing - (Thrie-Beam Retrofit) Intermediate Curb ORIGINATION Date: 5/15/24 Name: Joshua Turley Phone: 414-4475 Email: Joshua.turley@dot.state.fl.us COMMENTARY We have recently finished research into screw anchors and are now allowing them as an option on this Standard and we needed to add a note, option. COMMENTS AND RESPONSES BLACK = Industry Review Comments BLUE = Standard Plans Response GREEN
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/irr/2026/460-474-industryreviewresponse.pdf?sfvrsn=6097cbf1_1649-030-IndReviewResponse
Industry Review Comments and Responses FDOT – Standard Plans 1 Index 649-030 Standard Mast Arm Assemblies ORIGINATION Date: 4/18/25 Name: Josh Turley Phone: 414-4475 Email: Joshua.turley@dot.state.fl.us COMMENTARY Some fabricators have to ability and desire to fabricate these particular lengths as one piece and it is more economical to do so. This allows them to do so. COMMENTS AND RESPONSES BLACK = Industry Review Comments BLUE = Standard Plans Response GREEN = Change Made
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/irr/2027/649-030-indreviewresponse.pdf?sfvrsn=99d598f1_11020100-723FHWA
not addressed by the TTCP follow the Standard Plans. For all other applications, comply with the MUTCD and Standard Plans, Index 102-600. Device location or the number of devices, may be adjusted as recommended by the Work Zone Traffic Supervisor and approved by the Engineer. FDOT Standard Plans, the language that was removed from the Standard Plans. The revision is associated with spec revision, of Section 990, Section 994, Standard Plans and the Manual on Uniform Traffic Control Devices (MUTCD
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/fhwa/1020100-723fhwa.pdf?sfvrsn=b43fd612_2400-011IndCommentResponse
Industry Review Comments and Responses FDOT – Standard Plans 1 Index 400-011 Gravity Wall, BLUE = Standard Plans Response GREEN = Change Made to Index Name: Alex Lawrence Date: 6/19/24, ’s too short and not a standard hook. Followed up with a fabricator and the fabricator agreed a 3, in the Standard. If these comments were upheld, they should be a change to the Spec not the Standard. The Standard still needs to reference a Spec. CHANGE MADE TO INDEX: No Response Date: 7/10/24
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/irr/2026/400-011indcommentresponse.pdf?sfvrsn=7286b08_11020100-723FHWA2
in accordance with the Standard Plansuse temporary sign criteria provided in Standard Plans, Index, of Section 990, Section 994, Standard Plans and the Manual on Uniform Traffic Control Devices (MUTCD, conditions not addressed by the TTCP follow the Standard Plans. For all other applications, comply with the MUTCD and Standard Plans, Index 102-600. Device location or the number of devices, may be adjusted as recommended by the Work Zone Traffic Supervisor and approved by the Engineer. FDOT Standard
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/fhwa/1020100-723fhwa2.pdf?sfvrsn=1759a383_2102-201-Answers to Exec Mgmt
FY 2026-27 Standard Plans – 102-201 Temporary Acrow 700XS Series Detour Bridge General Notes, with FY 2026-27 Standard Plans (Effective July 1, 2026). Standard Plans Update Training, for implementation? The FY 2026-27 Standard Plans will be published on or before November 1, 2025. Standard Plans Update Training webinars will be provided for revisions in December of 2025. The FY 2026-27 Standard Plans will be effective for all projects let in July 2026 or after
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/irr/2027/102-201-answers-to-exec-mgmt.pdf?sfvrsn=55cf41b5_1SPI-415-010
Standard Plans Instructions Topic No. 625-010-003 Index 415-010 Bar Bending Details (FRP) FY, Standard Plans Index 415-010 includes commonly used types, shapes and configurations of straight, composite shapes that can obtained using the single shapes located on Standard Plans Index 415-010, and panels. For additional information and guidance see the Specifications, Standard Plans and/or Standard Plans Instructions for a given component. Standard Plans Instructions Topic No. 625-010-003
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/spi/spi-415-010.pdf?sfvrsn=fbc86ab5_11020917.resp
change: When attenuators are called for in the Plans or Standard Plans Contract Documents. . . Response: November 27, 2017 – Plans and Standard Plans are the Contract Documents that would call, . ****************************************************************************** No Name Comments: (Industry, 10-25-17) "When attenuators are called for in the Plans or Standard Plans, use either a truck mounted attenuator..." Is Standard Plans the new name for Design Standards, and therefore should be NCHRP 350. MASH is a program title. MASH without the year, 2016, is OK because FDOT
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/july-2018/review/comments-responses/1020917.resp.pdf?sfvrsn=ce7d7c0a_01100000.FHWA
ditches, and any other areas shown in the Plans to be cleared and grubbed. Remove and dispose of all, Documents. Meet the requirements for such miscellaneous work as specified in 110-10. 110-2 Standard, , including septic tanks, building foundations, and pipes. Perform Standard Clearing and Grubbing, the right-of-way line. Within all other areas where Standard Clearing and Grubbing is to be performed, , are not to be impacted by standard clearing and grubbing activity. If any impacts to roots or branches
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2017/july-2017/review/fhwa/1100000.fhwa.pdf?sfvrsn=4a004357_02025FDM944LandscapePlans
Topic #625-000-002 FDOT Design Manual 944 - Landscape Plans 944 Landscape Plans 944.1, are produced on a standard- format sheet (11”x17”) created using the FDOT CADD Software. Topic #625-000-002 FDOT Design Manual 944 - Landscape Plans Follow the same requirements contained in FDM 910, site-specific requirements not covered by the Standard Plans or Standard Specifications. Place, FDOT Design Manual 944 - Landscape Plans • Planting Plan • Irrigation Plan • Hardscape Plan
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/2025/review/2025fdm944landscapeplans.pdf?sfvrsn=d7d6e20_1SPI-000-510series
Standard Plans Instructions Topic No. 625-010-003 Index 000-510 and 000-511 Superelevation Transitions FY 2024-25 1 Index 000-510 and 000-511 Superelevation Transitions Design Criteria FDOT Design Manual ( FDM ); AASHTO A Policy on Geometric Design of Highways and Streets Design Assumptions and Limitations Indexes 000-510 and 000-511 provide requirements for installation of superelevation transitions on both low and high-speed highways. For superelevation criteria, see FDM
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/spi/spi-000-510series.pdf?sfvrsn=debd068_2SPI-000-510-511
Standard Plans Instructions Topic No. 625-010-003 Index 000-510 and 000-511 Superelevation Transitions FY 2025-26 1 Index 000-510 and 000-511 Superelevation Transitions Design Criteria FDOT Design Manual (FDM); AASHTO A Policy on Geometric Design of Highways and Streets Design Assumptions and Limitations Indexes 000-510 and 000-511 provide requirements for installation of superelevation transitions on both low and high-speed highways. For superelevation criteria, see FDM 210. Plan
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/spi/spi-000-510-511.pdf?sfvrsn=e9e20db2_1SPI-000-510-511
Standard Plans Instructions Topic No. 625-010-003 Index 000-510 and 000-511 Superelevation Transitions FY 2026-27 1 Index 000-510 and 000-511 Superelevation Transitions Design Criteria FDOT Design Manual ( FDM ); AASHTO A Policy on Geometric Design of Highways and Streets Design Assumptions and Limitations Indexes 000-510 and 000-511 provide requirements for installation of superelevation transitions on both low and high-speed highways. For superelevation criteria, see FDM
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2027/spi/spi-000-510-511.pdf?sfvrsn=53a20538_1550-001 550-002-Answers to Exec Mgmt
FY 2026-27 Standard Plans – 550-001 (Fence Type A), 550-002 (Fence Type B) – Adding Wildlife, Standard Plans (Effective July 1, 2026). Standard Plans Update Training will be provided prior, ? The FY 2026-27 Standard Plans will be published on or before November 1, 2025. Standard, Standard Plans will be effective for all projects let in July 2026 or after., promotes meaningful progress on improving safety as it provides a standard to build wildlife fences along
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/irr/2027/550-001-550-002-answers-to-exec-mgmt.pdf?sfvrsn=ce6e2b42_1