455-101FHWAApproved

. Spiral Ties: b. Carbon FRP: Meet the requirements of Specification Section 933. strand, meeting, . Prestressing Strands: b. Carbon FRP: Meet the requirements of Specification Section 932. 304, Grade 75, : c. All Strand diameters are nominal. b. Carbon FRP: Meet the requirements of Specification, -wire HSSS, Grade 240 B. Prestressing Strands: b. Carbon FRP: Meet the requirements of Specification

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/irr/2026/455-101fhwaapproved.pdf?sfvrsn=228e8511_1

9320300comm

: (8-29-19) The proposed revision of 9320300 includes the use of basalt FRP bars, however consensus, material standard such as D7957 that includes basalt fiber. If basalt FRP bars are not part of AASHTO, and will help the industry in general to adapt FRP products in general by giving civil engineers and specifiers, that the results may not be meaningful from a FRP system with a high fiber content like a rebar

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2020/january-2020/review/comments-responses/9320300comm.pdf?sfvrsn=b9ad3f61_2

4710100.FHWA

and the following substituted: 471-1 Description. Constructfiberreinforcedpolymer (FRP) fender, a design for the FRP fender system in accordance with 471- 4.2. ARTICLE 471-3 is deleted, . Constructfiberreinforcedpolymer (FRP) fender systems using components in accordance with this Section and the Plans. Submit a design for the FRP fender system in accordance with 471-4.2. ARTICLE 471-3

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/july-2016/review/fhwa/4710100.fhwa.pdf?sfvrsn=fea41c7e_0

4500203-722origind

for positions of reinforcing and prestressing steel or FRP. Apply the tolerances during and after, , FRP reinforcing, prestressing steel, FRP prestressing strands, or any other metallic or polymeric, steel, FRP reinforcing, prestressing steel, FRP prestressing strands, or any other metallic, for all pretensioned prestressed concrete products containing FRP bars, FRP strands, or stainless

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/internal/4500203-722origind.pdf?sfvrsn=cd8dd3d6_2

4100200.FHWA

for stainless steel and FRP reinforcing and prestressing strand into the Standard Specifications. Please, , including reinforcing steel grade or FRP reinforcing type, sizes and spacings, concrete cover, with modifications to the wall and slab thickness, or haunch dimensions, or the use of FRP reinforcing, pay items for concrete (culverts), and reinforcing steel (roadway), and FRP reinforcing. 4100200, : Provide precast box segments identical to the plan details, including reinforcing steel grade or FRP

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/july-2016/review/fhwa/4100200.fhwa.pdf?sfvrsn=15d740c3_0

9320103int

. 932-4.3.1 Changes to FRP sampling will also save contractors money. What impact does the change have on production or construction schedules? 932-4.3.1 Changes to FRP sampling rate and test location, of the materials in place. 932-4.3.1 Changes in FRP sampling rate and test location will improve, from the producer of the FRP reinforcing bars, confirming compliance with the requirements, LOT, per bar size of or a combined length of more than 20,000-feet of FRP reinforcing for testing

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2026-27/review/internal/9320103int.pdf?sfvrsn=16a0335a_1

9320103ind

. 932-4.3.1 Changes to FRP sampling will also save contractors money. What impact does the change have on production or construction schedules? 932-4.3.1 Changes to FRP sampling rate and test location, of the materials in place. 932-4.3.1 Changes in FRP sampling rate and test location will improve, from the producer of the FRP reinforcing bars, confirming compliance with the requirements, LOT, per bar size of or a combined length of more than 20,000-feet of FRP reinforcing for testing

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2026-27/review/industry/9320103ind.pdf?sfvrsn=51ab7486_1

4500203-122FHWA

the tolerances shown for positions of reinforcing and prestressing steel or FRP. Apply the tolerances, for reinforcing steel, FRP reinforcing, prestressing steel, FRP prestressing strands, or any other metallic, for reinforcing steel, FRP reinforcing, prestressing steel, FRP prestressing strands, or any other, to violate the tolerances shown for positions of reinforcing and prestressing steel or FRP. Apply, for reinforcing steel, FRP reinforcing, prestressing steel, FRP prestressing strands, or any other

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/january-2022/review/fhwa/4500203-122fhwa.pdf?sfvrsn=8a49cff4_2

4500203-122origind

and prestressing steel or FRP. Apply the tolerances during and after the fabrication of prestressed products. Do not reduce the concrete cover for reinforcing steel, FRP reinforcing, prestressing steel, FRP, 1/4 inch. Do not reduce the concrete cover for reinforcing steel, FRP reinforcing, prestressing steel, FRP prestressing strands, or any other metallic or polymeric objects when the cover specified

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/january-2022/review/internal/4500203-122origind.pdf?sfvrsn=f3f24978_2

4150000.origind

. Obtain all FRP reinforcing bars from a producer on the Department’s Production Facility Listing. 415-2, prior to incorporation into the work. 415-3.2 FRP Reinforcing: Store FRP reinforcement above, and direct exposure to UV light and mechanical injury. When placing FRP reinforcement in the work, ensure that the FRP reinforcement is free for dirt, paint, oil, and other foreign material. 415-4, , or thermal cut reinforcing steel. 415-4.2 FRP Reinforcing: No field fabrication of FRP reinforcing

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/july-2016/review/internal/4150000.origind.pdf?sfvrsn=5d6e4ec4_0

5560102.impl

tunneling Jacking DI, FRPM, PC, PCCP, RCCP, RCP, Steel Table 556-2.2 Material Standards Acceptable, Installations Material Type Non-Pressure Pressure Fiberglass Reinforced Polymer Mortar (FRPM) ASTM D3262

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/january-2018/review/implemented/5560102.impl.pdf?sfvrsn=933074b6_0

2024nov-thu03-SRCUpdate

of Impact Damaged Utility Poles with FRP 6/30/2015 Large Reinforcing Bars Spliced In Ultra-High, Poles with FRP https://www.fdot.gov/structures/structuresresearchcenter/completedresearch.shtm 5 Objectives: Damaged utility poles can be repaired with fiber- reinforced polymers (FRP) without, and effectively restoring an impact-damaged utility pole. Va riables: FRP repair system, Impact energy, Repair of Impact Damaged Utility Poles with FRP https://www.fdot.gov/structures/structuresresearchcenter

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/training/transportationsymposium/2024-november/2024nov-thu03-srcupdate.pdf?sfvrsn=4eb49c14_1

2024nov-thu03-SRCUpdate

of Impact Damaged Utility Poles with FRP 6/30/2015 Large Reinforcing Bars Spliced In Ultra-High, Poles with FRP https://www.fdot.gov/structures/structuresresearchcenter/completedresearch.shtm 5 Objectives: Damaged utility poles can be repaired with fiber- reinforced polymers (FRP) without, and effectively restoring an impact-damaged utility pole. Va riables: FRP repair system, Impact energy, Repair of Impact Damaged Utility Poles with FRP https://www.fdot.gov/structures/structuresresearchcenter

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/training/transportationsymposium/2024-june/2024nov-thu03-srcupdate.pdf?sfvrsn=3d994966_1

9320200-724origind

, type B, class C). 932-43 Fiber Reinforced Polymer (FRP) Reinforcing Bars. 932-43.1 General: Obtain FRP reinforcing bars from producers currently on the Department’s Production Facility Listing, that meet the requirements of ASTM D578. 932-43.2 Bar Sizes and Loads: The sizes and loads of FRP, 12.1 Volume IITable 932-7. 9320200 Table 932-86 Sizes and Tensile Loads of FRP Reinforcing Bars, for the types and sizes of FRP reinforcing produced. Qualification testing shall be conducted

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/internal/9320200-724origind.pdf?sfvrsn=32f5b967_1

4500204FHWA

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sections 415 and 931 FRP Reinforcing ................................. Sections 415 and 932 FRP Spirals, tensioned strands (dormant strands). *****The FRP spirals cannot be used in combination with steel, ..................................... Sections 415 and 931 FRP Reinforcing ................................. Sections 415 and 932 FRP Spirals ***...................................................Section 932 Embedded

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2025-26/review/fhwa/4500204fhwa.pdf?sfvrsn=e89a140f_1

5560102.FHWA

Micro tunneling Jacking DI, FRPM, PC, PCCP, RCCP, RCP, Steel Table 556-2.2 Material Standards, Mortar (FRPM) ASTM D3262 ASTM D3517 AWWA C950 Polymer Concrete (PC) DIN 54815-1 & 2 N, Jacking DI, FRPM, PC, PCCP, RCCP, RCP, Steel Table 556-2.2 Material Standards Acceptable for J&B, Installations Material Type Non-Pressure Pressure Fiberglass Reinforced Polymer Mortar (FRPM

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/january-2018/review/fhwa/5560102.fhwa.pdf?sfvrsn=bdfb13ce_0

4500100.origind

method. In this method, steel or Fiber Reinforced Polymer (FRP) components are stressed and anchored; the concrete for the product is then cast and cured, and finally the stress in the steel or FRP, of reinforcing and prestressing steel or FRP. Apply the tolerances during and after the fabrication of prestressed products. Do not reduce the concrete cover for reinforcing steel, FRP reinforcing, prestressing steel, FRP prestressing strands, or any other metallic objects specified in the Plans

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/july-2016/review/internal/4500100.origind.pdf?sfvrsn=6ec1feb3_0

4500100.impl

method. In this method, steel or fiber reinforced polymer (FRP) components are stressed and anchored; the concrete for the product is then cast and cured, and finally the stress in the steel or FRP, and prestressing steel or FRP. Apply the tolerances during and after the fabrication of prestressed products. Do not reduce the concrete cover for reinforcing steel, FRP reinforcing, prestressing steel, FRP prestressing strands, or any other metallic objects specified in the Plans more than 1/4

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/july-2016/review/implemented/4500100.impl.pdf?sfvrsn=cd6ef348_0

FY24 Status Report Website 2.16.24

MusselmanExecuted SMO-24-07 Extraction and Physio-Mechanical Testing of FRP Reinforcing from 5-year, under review STR-24-03 Waterline Pile Cap Footings for Bridges Using Large Diameter FRP Renforcing

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/research/docs/fy24-status-report-website-2-16-24.pdf?sfvrsn=af0be6d3_3