4220 search results for drainage
TP-02-13-25WorkClassBreakout
Experience in Drainage Repair Required E8V93-R0 PROPOSAL E8V55 E8V85-R0 E8V86-R0 No Pre
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/tp/lettings/2025/feb13/tp-02-13-25workclassbreakout.pdf?sfvrsn=e284625e_2E55F6
, Signing/Pavement Marking, Drainage Inlet and Pipe, Bridge Approach Slab Joint Repair, And Traffic
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d5/lettings/2025/mar04/e55f6.pdf?sfvrsn=8363d543_1EnvironmentalFeatures
• Drainage swales impacts only • Cultural Resources Assessment Surveys were prepared in 2018
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/i95-858-820-docs/april2025publicmtg/environmentalfeatures.pdf?sfvrsn=71c2503_3SPM4270000-724-i19416
SEALING OF DRAINAGE STRUCTURES. (REV 3-9-18) (FY 2024-25) The following new Section is added after Section 425: SECTION 427 SEALING OF DRAINAGE STRUCTURES 427-1 Description. Seal inlets, manholes, and junction boxes, including the structure’s base, walls, top slab, riser, cone, and inlet, with the manufacturer’s procedures. 427-5 Materials. 425-5.1 Chemical Sealing of Drainage Structures: All, . Apply non-shrink cement grout to the structure walls. Reconstruct or repair the drainage structure
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/maintenance/finalized/spm4270000-724-i19416.pdf?sfvrsn=6b123346_1SPM4250600-724-i19202
: 1. The number of existing drainage structures modified, 2. The number of inlets relocated, 3
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/maintenance/finalized/spm4250600-724-i19202.pdf?sfvrsn=cac27056_1SPM1205000-724-i19415
ROADSIDE DITCH OR CANAL CLEANING AND GRADING. (REV 10-1-15) (FY 2024-25) The following new Section is added after Section 120: SECTION 120-50 ROADSIDE DITCH OR CANAL CLEANING AND GRADING 120-50.1 Description. Clean and grade ditch and canal to allow free and unobstructed flow of drainage water. Reshape and remove undesirable materials in ditches, slopes, or canal restoration according to the line, grade, and typical section for the particular roadway or special grades, as provided
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/maintenance/finalized/spm1205000-724-i19415.pdf?sfvrsn=9b8845d5_1SPM5360100-725-i19898
and shaped to allow unobstructed drainage. 536-3.15.2 Galvanizing: Apply coating of galvanized
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2025-26/maintenance/finalized/spm5360100-725-i19898.pdf?sfvrsn=ac91bf21_1SPM5360100-725
and shaped to allow unobstructed drainage. 536-3.15.2 Galvanizing: Apply coating of galvanized
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2025-26/maintenance/finalized/spm5360100-725.docx?sfvrsn=602c9a80_1SPM4270000-725-i19886
SEALING OF DRAINAGE STRUCTURES. (REV 3-9-18) (FY 2025-26) The following new Section is added after Section 425: SECTION 427 SEALING OF DRAINAGE STRUCTURES 427-1 Description. Seal inlets, manholes, and junction boxes, including the structure’s base, walls, top slab, riser, cone, and inlet, with the manufacturer’s procedures. 427-5 Materials. 425-5.1 Chemical Sealing of Drainage Structures: All, . Apply non-shrink cement grout to the structure walls. Reconstruct or repair the drainage structure
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2025-26/maintenance/finalized/spm4270000-725-i19886.pdf?sfvrsn=1b900a03_1SPM4250600-725-i19885
: 1. The number of existing drainage structures modified, 2. The number of inlets relocated, 3
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2025-26/maintenance/finalized/spm4250600-725-i19885.pdf?sfvrsn=c8c54e28_1SPM1205000-725-i19882
ROADSIDE DITCH OR CANAL CLEANING AND GRADING. (REV 10-1-15) (FY 2025-26) The following new Section is added after Section 120: SECTION 120-50 ROADSIDE DITCH OR CANAL CLEANING AND GRADING 120-50.1 Description. Clean and grade ditch and canal to allow free and unobstructed flow of drainage water. Reshape and remove undesirable materials in ditches, slopes, or canal restoration according to the line, grade, and typical section for the particular roadway or special grades, as provided
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2025-26/maintenance/finalized/spm1205000-725-i19882.pdf?sfvrsn=229d5d43_1SPM5750000-725-i19904
. For sodding in drainage ditches, stagger the setting of the sod pieces to avoid a continuous seam along
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2025-26/maintenance/finalized/spm5750000-725-i19904.pdf?sfvrsn=b436f254_1SSM4270000-723-i18613
SEALING OF DRAINAGE STRUCTURES. (REV 3-9-18) (FY 2023-24) The following new Section is added after Section 425: SECTION 427 SEALING OF DRAINAGE STRUCTURES 427-1 Description. Seal inlets, manholes, and junction boxes, including the structure’s base, walls, top slab, riser, cone, and inlet, with the manufacturer’s procedures. 427-5 Materials. 425-5.1 Chemical Sealing of Drainage Structures: All, -shrink cement grout to the structure walls. Reconstruct or repair the drainage structure invert bench
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/maintenance/finalized/ssm4270000-723-i18613.pdf?sfvrsn=99541889_2SSM1205000-723-i18612
120-50 ROADSIDE DITCH OR CANAL CLEANING AND GRADING. (REV 10-1-15) (FY 2023-24) The following new Section is added at the end of Section 120: SECTION 120-50 ROADSIDE DITCH OR CANAL CLEANING AND GRADING 120-50.1 Description. Clean and grade ditch and canal to allow free and unobstructed flow of drainage water. Reshape and remove undesirable materials in ditches, slopes, or canal restoration according to the line, grade, and typical section for the particular roadway or special grades
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/maintenance/finalized/ssm1205000-723-i18612.pdf?sfvrsn=453f2ad7_2SPM4250600-723-i18580
: 1. The number of existing drainage structures modified, 2. The number of inlets relocated, 3
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/maintenance/finalized/spm4250600-723-i18580.pdf?sfvrsn=bda9945c_2SSM1205000-122
120-50 ROADSIDE DITCH OR CANAL CLEANING AND GRADING. (REV 10-1-15) (1-22) The following new Section is added at the end of Section 120: SECTION 120-50 ROADSIDE DITCH OR CANAL CLEANING AND GRADING 120-50.1 Description. Clean and grade ditch and canal to allow free and unobstructed flow of drainage water. Reshape and remove undesirable materials in ditches, slopes, or canal restoration according to the line, grade, and typical section for the particular roadway or special grades
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/january-2022/maintenance/finalized/ssm1205000-122.pdf?sfvrsn=10765509_2SPM4250600-122
. The number of existing drainage structures modified, 2. The number of inlets relocated, 3
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/january-2022/maintenance/finalized/spm4250600-122.pdf?sfvrsn=5416f71d_2SSM4270000-122
SEALING OF DRAINAGE STRUCTURES. (REV 3-9-18) (1-22) The following new Section is added after Section 425: SECTION 427 SEALING OF DRAINAGE STRUCTURES 427-1 Description. Seal inlets, manholes, and junction boxes, including the structure’s base, walls, top slab, riser, cone, and inlet tops, with the manufacturer’s procedures. 427-5 Materials. 425-5.1 Chemical Sealing of Drainage Structures: All materials, cement grout to the structure walls. Reconstruct or repair the drainage structure invert bench
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/january-2022/maintenance/finalized/ssm4270000-122.pdf?sfvrsn=4eea932d_2SSM4270000-722-i17982
SEALING OF DRAINAGE STRUCTURES. (REV 3-9-18) (7-22) The following new Section is added after Section 425: SECTION 427 SEALING OF DRAINAGE STRUCTURES 427-1 Description. Seal inlets, manholes, and junction boxes, including the structure’s base, walls, top slab, riser, cone, and inlet tops, with the manufacturer’s procedures. 427-5 Materials. 425-5.1 Chemical Sealing of Drainage Structures: All materials, cement grout to the structure walls. Reconstruct or repair the drainage structure invert bench
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/maintenance/finalized/ssm4270000-722-i17982.pdf?sfvrsn=f802d1f5_2SPM4250600-722
. The number of existing drainage structures modified, 2. The number of inlets relocated, 3
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/maintenance/finalized/spm4250600-722.pdf?sfvrsn=a152476a_2