9274 search results for test
3460000.origind
cylindrical test specimens to the Engineer for resistivity testing before mix design approval. Take, the Engineer at least 48 hours before performing such tests. Perform slump loss testing of the drilled shaft, strength tests. Record the ambient air temperature during the test. Ensure that the concrete, samples. Perform surface resistivity tests on the core samples or test cylinders at 28 days. Submit the results of the laboratory trial batch tests and field demonstration of verified test data
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul11/files/3460000.origind.pdf?sfvrsn=3b36aa77_09160000.impl
. 916-2.3 Reporting: Specification compliance testing results shall be reported for the tests, in accordance with Section 6. Any marked variation from the original test values for a material below, additional requirements: 1. The intermediate test temperature at 10 rad/sec. for the Dynamic Shear Rheometer (DSR) test (AASHTO T315-12 (2016)) shall be 26.5ºC for PG grades PG 67 and higher. 2. An additional high temperature grade of PG 67 is added for which the high test temperature at 10 rad
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2019/january-2019/review/implemented/9160000.impl.pdf?sfvrsn=d3b55520_09210000.FHWA
or verification test results. Discontinuance of approval may be based on testing at the point of use, of quality control or verification test results. Discontinuance of approval may be based on testing, plus 0.658% K2O), may be used with no further testing. High Alkali Cement containing a maximum, cement is used in cConcrete, the test results shall verify improved or comparable strength, sulfate, %. The strength and durability tests of concrete shall be performed in accordance with AASHTO T358, ASTM
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul19/files/9210000-fhwa.pdf?sfvrsn=6f2011db_24510405-723impl
and mixed in accordance with the manufacturer's recommendations. Do not perform strength testing as system performance will be measured by proof-testing each anchor. The Department may require cylinder testing if the Contractor uses admixtures or irregularities occur in anchor testing. Cast a set, of 3,400 psi within seven days, when tested in accordance with ASTM C39
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/implemented/4510405-723impl.pdf?sfvrsn=4c1977c3_19750000COMM
testing does not include measuring test panels for color and/or gloss retention, yet this data, resistance testing, ASTM D5894). Field test data regarding color and gloss retention would serve as vital, - With reference to the statement, furnish product testing information according to AASHTO R31, define the reference to the specific section number(s) for product testing and certification. Section 975-5.2, system for testing and certification as long as it meets the performance requirements defined within
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan06/files/9750000comm.pdf?sfvrsn=d9e9bcf1_09480100COMM
9480100 Jobs with pipe *********************************************************************************************** Paul Harkins File: 9480100 - Miscellaneous Types of Pipe Username: Paul Harkins UserEmail: paul.harkins@hardiepipe.com UserTel: 813-478-6240 UserFAX: 866-329-3727 Date: Tuesday, April 05, 2005 Time: 07:49:12 AM Comments: 1. Is it clear that testing of joint, as tested in the plant and refer back to the individual material specifications
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan06/files/9480100comm.pdf?sfvrsn=85046f46_09710107.impl
, retroreflective elements shall contain no more that 200 ppm by weight of lead or arsenic when tested in accordance with the Environmental Protection Agency (EPA) Testing Methods 3052, 6010B, and 6010C
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul13/files/9710107.impl.pdf?sfvrsn=145fd03d_0SS9710107
, retroreflective elements shall contain no more that 200 ppm by weight of lead or arsenic when tested in accordance with the Environmental Protection Agency (EPA) Testing Methods 3052, 6010B, and 6010C
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2013/files/ss9710107.pdf?sfvrsn=631f0a67_09430100COMM
that testing of joint is not required to be done in the field? 2. Each of the materials, is considered to be water and soil tight as tested in the plant and refer back to the individual material
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan06/files/9430100comm.pdf?sfvrsn=a6f8bbc_09450100COMM
that testing of joint is not required to be done in the field? 2. Each of the materials specifications, to be water and soil tight as tested in the plant and refer back to the individual material
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan06/files/9450100comm.pdf?sfvrsn=fc1226d5_09940203.impl
Requirements: 994-2.3.1 General: Sheeting, process inks and overlay materials must be tested, requirements that are color dependent, each color included in the APL application must be tested, systems consisting of inks and/or overlays will be tested as a system consisting of white base sheeting and each color of ink and/or overlay. Panels for testing sheeting must be prepared in accordance with 994-3 for testing. The in-service life for the sign sheeting system will equal the life
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/july-2018/review/implemented/9940203.impl.pdf?sfvrsn=6a54f94e_0SP4570000
cathodic protection jackets are specified. 457-2.6.2 Testing: No test report for tests made more than, to the materials tested. Attach current test reports to the certificate. Submit certified test results, sampling and testing using Quality Control technicians meeting the requirements of Section 105. Test, for the Department approved design mixes. Test the materials at a frequency of one set of tests per, strength testing at the required test date. The Engineer may adjust the frequency of testing based
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2020/january-2020/workbook/sp4570000.pdf?sfvrsn=e0250b2_2SP4570000
cathodic protection jackets are specified. 457-2.6.2 Testing: No test report for tests made more than, to the materials tested. Attach current test reports to the certificate. Submit certified test results, sampling and testing using Quality Control technicians meeting the requirements of Section 105. Test, for the Department approved design mixes. Test the materials at a frequency of one set of tests per, strength testing at the required test date. The Engineer may adjust the frequency of testing based
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2019/july-2019/workbook/sp4570000.pdf?sfvrsn=ca9c07b9_2SP4570000
cathodic protection jackets are specified. 457-2.6.2 Testing: No test report for tests made more than, to the materials tested. Attach current test reports to the certificate. Submit certified test results, sampling and testing using Quality Control technicians meeting the requirements of Section 105. Test, for the Department approved design mixes. Test the materials at a frequency of one set of tests per, strength testing at the required test date. The Engineer may adjust the frequency of testing based
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/january-2018/workbook/sp4570000.pdf?sfvrsn=f7ce1cde_0SP4570000
protection jackets are specified. 457-2.6.2 Testing: No test report for tests made more than two years, and testing using Quality Control technicians meeting the requirements of Section 105. Test properties, for the Department approved design mixes. Test the materials at a frequency of one set of tests per load of the mixer. For each set of tests, cast three 4 inch by 8 inch cylinders for compressive strength testing at the required test date. The Engineer may adjust the frequency of testing based on consistency
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2017/january-2017/workbook/sp4570000.pdf?sfvrsn=32923393_0SP4570000
protection jackets are specified. 457-2.6.2 Testing: No test report for tests made more than two years, and testing using Quality Control technicians meeting the requirements of Section 105. Test properties, for the Department approved design mixes. Test the materials at a frequency of one set of tests per load of the mixer. For each set of tests, cast three 4 inch by 8 inch cylinders for compressive strength testing at the required test date. The Engineer may adjust the frequency of testing based on consistency
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2017/july-2017/workbook/sp4570000.pdf?sfvrsn=b81b6a42_06600202ind
Way Vehicle (WWVDS) Detection System: Submit a test plan for the field acceptance test (FAT) to the Engineer a minimum of 30 calendar days before commencement of testing for review and approval; tests cannot commence or be scheduled until test plans are approved by the Engineer. For each testing, Testing: Conduct this test on a closed ramp using Contractor-provided test vehicles while lanes, the highlighted signs. N = Total number of test vehicle runs. 660-4.4.2 False Positive Testing
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2026-27/review/industry/6600202ind.pdf?sfvrsn=601a42fb_16600202int
Way Vehicle (WWVDS) Detection System: Submit a test plan for the field acceptance test (FAT) to the Engineer a minimum of 30 calendar days before commencement of testing for review and approval; tests cannot commence or be scheduled until test plans are approved by the Engineer. For each testing, Testing: Conduct this test on a closed ramp using Contractor-provided test vehicles while lanes, the highlighted signs. N = Total number of test vehicle runs. 660-4.4.2 False Positive Testing
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2026-27/review/internal/6600202int.pdf?sfvrsn=c14eaed7_14570000.FHWA
are specified. 457-2.6.2 Testing: No test report for tests made more than one yeartwo years prior, jackets are specified. 457-2.6.2 Testing: No test report for tests made more than two years prior, and conform in all respects to the materials tested. Attach copies of current test reports, design mixes. Test the materials at a frequency of one set of tests per load of the mixer. For each set of tests, cast three 4 inch by 8 inch cylinders for compressive strength testing at the required
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul12/files/4570000.fhwa.pdf?sfvrsn=d020eabe_04551508.FHWA
to perform testing. The Department may also perform comparison tests. Provide equipment, to perform testing. The Department may also perform comparison tests. Provide equipment for such comparison, to certain testing when slurry is not used in shaft excavation. Please review and transmit your, shafts to support miscellaneous structures, the applicable test methods and reporting requirements described in 455-15.8.1 apply to tests of fluid in the shaft prior to placing the concrete
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/july-2014/review/fhwa/4551508.fhwa.pdf?sfvrsn=6b6058b7_0