9274 search results for test
0060000SS
of materials that have been tested and accepted at the source of supply, or may require the testing, not exist for a particular test, perform the testing in accordance with the method specified, may inspect and test any materials, at points of production, distribution and use. 6-1.2 Sampling and Testing: Use the Department’s current sample identification and tracking system to provide, certified manufacturer’s test results to the Engineer for qualification and use on Department
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2006/files/0060000ss.pdf?sfvrsn=49f215b5_0SS0060000
in such references. 6-3.2 Test Methods: Methods of sampling and testing materials are in accordance, the testing in accordance with the method specified in the Specification. When test methods or other, inspect and test any material, at points of production, distribution and use. 6-1.2 Sampling and Testing: Use the Department’s current sample identification and tracking system to provide related, : Submit certified manufacturer’s test results to the Engineer for qualification and use
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2007/files/ss0060000.pdf?sfvrsn=312c78c5_0SS0060000
in such references. 6-3.2 Test Methods: Methods of sampling and testing materials are in accordance, the testing in accordance with the method specified in the Specification. When test methods or other, . Testing without Department’s qualification may result in a rejection of the test results. Continued, may inspect and test any material, at points of production, distribution and use. 6-1.2 Sampling and Testing: Use the Department’s current sample identification and tracking system to provide related
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2008/january-2008/workbook/ss006000032b8ea40f0b44fe5b995174f2f2b5cab.pdf?sfvrsn=dec3ffe5_0SS0060000
in such references. 6-3.2 Test Methods: Methods of sampling and testing materials are in accordance, the testing in accordance with the method specified in the Specification. When test methods or other, . Testing without Department’s qualification may result in a rejection of the test results. Continued, may inspect and test any material, at points of production, distribution and use. 6-1.2 Sampling and Testing: Use the Department’s current sample identification and tracking system to provide related
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2008/january-2008/workbook/ss0060000.pdf?sfvrsn=358ac3da_03460000.COMM
“hold” cylinders are tested within seven days of the 28-day strength tests.” Question: Who, were tested at a w/c ratio of 0.35. It is well known within the concrete testing community, regarding reduced frequency for acceptance testing? ************************************************************************ Ghulam Mujtaba: General Comment: 1- The nondestructive tests are used to estimate the strength of concrete. It should be verified by Destructive testing. 2- In the other
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/programmanagement/implemented/workbooks/history/jul07/files/3460000.comm.pdf?sfvrsn=38149fbc_03460100FHWA
determined by the concrete producer for each mix design to be tested. Record and certify test results, for verification (VT) testing. When the Engineer’s VT test results do not compare with the QC plastic, for Verification (VT) testing. When the Engineer’s VT test results do not compare with the QC plastic, and testing in accordance with this Section. The acceptance sample and plastic properties tests may, size meeting the requirements of ASTM C31, and secure area for testing and initial curing of test
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2026-27/review/fhwa/3460100fhwa.pdf?sfvrsn=c3e07a79_1SS1200000
, reduce the QC density testing to one test every two LOTs by identifying the substantiating tests, a test section of the length of one full LOT. Perform five QC tests at random locations within the test section. All five QC tests and a Department Verification test must meet the density required, or when the QC tests cannot be verified, construct a new test section. The Contractor may elect to place, meet the following conditions: QC tests must meet the specifications. Verification test must meet
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2014/files/ss1200000.pdf?sfvrsn=c8d5b1f1_04550510.FHWA
testing prior to driving. All test piles will have dynamic load tests. The Engineer will perform Dynamic, Load Tests: Dynamic load testing consists of predicting estimating pile capacity from blows, which are to be statically (or Statnamically) load tested, drive test piles their full length, will be paid for as Pile Redrive. Install instruments on test piles when dynamic load tests are included, dowel splices in the Pay Item 455-34. No payment will be made for dynamic load tests on test piles
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul11/files/4550510.fhwa.pdf?sfvrsn=f283df9b_09750900.impl
from visual impact of the structure. 975-9.2 Material Tests: Meet the following requirements: Additional Laboratory Performance and Tests Test Method Limits Cyclic Weather Testing AASHTO R-31, through (4 minimum rating) Additional Laboratory Performance and Tests Test Method Limits Fluid, Coating removability Per Manufacturer’s specifications: 6 months exposure at FDOT test site
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul08/files/9750900.impl.pdf?sfvrsn=250688f2_0SS9750900
of the structure. 975-9.2 Material Tests: Meet the following requirements: Additional Laboratory Performance and Tests Test Method Limits Cyclic Weather Testing AASHTO R-31 No blistering, cracking, checking, ) Additional Laboratory Performance and Tests Test Method Limits Fluid Resistance ASTM D1308; Paint, Manufacturer’s specifications: 6 months exposure at FDOT test site Complete removal of material
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/programmanagement/implemented/workbooks/revisions/july08/ss9750900.pdf?sfvrsn=e2315aac_0SS9750900
of the structure. 975-9.2 Material Tests: Meet the following requirements: Additional Laboratory Performance and Tests Test Method Limits Cyclic Weather Testing AASHTO R-31 No blistering, cracking, checking, ) Additional Laboratory Performance and Tests Test Method Limits Fluid Resistance ASTM D1308; Paint, Manufacturer’s specifications: 6 months exposure at FDOT test site Complete removal of material
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2009/january-2009/workbook/ss9750900.pdf?sfvrsn=65ee5f10_04600102-723comm
be tested. Perform Magnetic Particle Testing at the following frequencies: A minimum of 25% of all, by the following: Unless otherwise shown in the Plans, perform ultrasonic testing (UT) or radiographic testing (RT) on full penetration groove welds at the following frequency (use the AWS D1.1 Tubular, be tested. 460-6.4.3 Overhead Sign Structures and Toll Gantries : Comply with the requirements, in the Plans, perform 100 percent ultrasonic testing (UT) or radiographic testing (RT) on all full
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/comments-responses/4600102-723comm.pdf?sfvrsn=bf77fef5_24600102-723resp
be tested. Perform Magnetic Particle Testing at the following frequencies: A minimum of 25% of all, by the following: Unless otherwise shown in the Plans, perform ultrasonic testing (UT) or radiographic testing (RT) on full penetration groove welds at the following frequency (use the AWS D1.1 Tubular, be tested. 460-6.4.3 Overhead Sign Structures and Toll Gantries : Comply with the requirements, in the Plans, perform 100 percent ultrasonic testing (UT) or radiographic testing (RT) on all full
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/comments-responses/4600102-723resp.pdf?sfvrsn=fd23dd7f_29710000-722impl
strength of 40 psi when tested according to ASTM D638. A rectangular test specimen 6 inches by 1 inch, (2.5 to 15 µm) for the vehicle component. The Department will test hot-applied standard, . The Department will test preformed thermoplastic and hot-applied high friction thermoplastic pavement, Product Evaluation Program (NTPEP) field test data meeting FDOT Specification requirements. A notation of the number of coats and the thickness of each coat at which the product passes testing may
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/implemented/9710000-722impl.pdf?sfvrsn=856948e1_29750700.impl
Performance Requirements: For laboratory testing, use flat test panels prepared in accordance, at the Department’s outdoor test site in accordance with ASTM G 7. Laboratory Testing - Non-Sacrificial Property Test M e t h o d Requirement Cyclic Weather Testing (solvent cleanable and water cleanable, , softening or adhesion loss. Outdoor Exposure Testing – Non-Sacrificial Property Test M e t h o d, spray paint. No delamination or visual defects. Laboratory Testing - Sacrificial Property Test M
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul12/files/9750700.impl.pdf?sfvrsn=f3705b09_02000502-724FHWA
locations within the test section. Each set will include five density tests. One set will include, to the entire course thickness. All QC tests and a Department Verification test must meet the density, . If the Verification test fails, and QC test data is not upheld by Resolution testing the QC testing will revert, no Resolution testing is required for 12 consecutive verified LOTs, or if required, the QC test data, of testing. If the Verification test fails, and QC test data is not upheld by Resolution testing
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/fhwa/2000502-724fhwa.pdf?sfvrsn=b7c12d53_1GL-07A
tests are CTQP qualified. All documents are adequately filed. [Spec. 105-5 and 330-2] 14. Testing, conditions are suitable for the paving operations. [Spec. 330-3] 8. Perform verification test to ensure, will facilitate multiple tests being run simultaneously by two technicians. [Spec. 320-2] 16. The lighting, . Calibration of the laboratory testing equipment is performed in accordance with manufacturer’s, and testing equipment and supplies for performing quality control, acceptance and verification
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/construction/constadm/guidelist/inspectguidelist/fy1314/gl-07a.pdf?sfvrsn=16e1bf13_09940700IMP
, the Contractor shall be required to furnish to the Engineer one certified test report from, of this Section. The certified test report shall include test results for retroreflectivity, color, adhesive, and chemical resistivity. The certified test report shall affirm the product meets all the requirements specified. If test results indicate significant inconsistencies in material properties, new qualification tests and/or comparison with original infrared spectroscopic values may be required. Each
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan06/files/9940700imp.pdf?sfvrsn=c39659a1_09330000.impl
Testing Requirements for Qualification of Producers of Prestressing CFRP Strands Property Test M e t h o, 440.4, following the test methods from ACI 440.3. The CFRP strand shall meet the additional, % of the specified ultimate strength for parallel wire assemblies. 933-5 Required Tests for Prestressing Strand and Bar. 933-5.1 General: Tests shall be performed to determine the physical characteristics of prestressing reinforcement. For tests specified to be made by the producer, certified copies
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/july-2016/review/implemented/9330000.impl.pdf?sfvrsn=66eb3ad7_09600100-722FHWA
running the required test methods. 960-3.1.3 System Testing: In lieu of performing PT system tests, all testing, other than field testing, and to submit certified test reports for materials, System Testing: In lieu of performing PT system tests witnessed by and/or performed in a certified, by the Engineer. 960-3.2 Testing Requirements: 960-3.2.1 Component and System Tests: Corrugated duct, Assembly Pressure Test: In addition to the other testing specified in this Section, test all filler
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/fhwa/9600100-722fhwa.pdf?sfvrsn=ee7a2e9c_2