4868 search results for Standard Specifications
CM-663-01 Signal Priority and Preemption System
the provisions of Sections 663 and 995 of the FDOT Standard Specifications for Road and Bridge, , GPS, or radio frequency technologies. FORMDROPDOWN Provide product literature, specifications, to authorized users and vehicles only. FORMDROPDOWN Provide product literature, specifications, user, , specifications, user manual, or similar information that shows the product meets this requirement. Document, Provide product literature, specifications, user manual, or similar information that shows the product
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/traffic/traf_sys/compliance-matrices-2022/cm-663-01-signal-priority-and-preemption-system.docx?sfvrsn=f58ce266_1SPI-534-200
Standard Plans Instructions Topic No. 625-010-003 Index 534-200 Precast Noise Walls FY 2024-25 1 Index 534-200 Precast Noise Walls Design Criteria AASHTO LRFD Bridge Design Specifications, . This Standard Plan is designed for noise walls outside the clear zone. If noise walls cannot be placed, of SDG 2.4 and SDG 3.16. Velocity Pressure Exposure Coefficient (Kz) is 1.0 for all standard, Granular Soil (Type 2) Standard Penetration Test (SPT) N Values between 10 and 40 o Effective
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/spi/spi-534-200.pdf?sfvrsn=82ce9d1f_2SPI-534-200
Standard Plans Instructions Topic No. 625-010-003 Index 534-200 Precast Noise Walls FY 2025-26 1 Index 534-200 Precast Noise Walls Design Criteria AASHTO LRFD Bridge Design Specifications, Design Assumptions and Limitations See SDG 3.16 for structural design criteria. This Standard, and SDG 3.16. Velocity Pressure Exposure Coefficient (Kz) is 1.0 for all standard wall heights, (Type 2) Standard Penetration Test (SPT) N Values between 10 and 40 o Effective Soil Unit Weight
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/spi/spi-534-200.pdf?sfvrsn=269b11e_15270100-122FHWA
, Florida 32312 Re: State Specifications Office Section: 527 Proposed Specification: 5270100, State Specifications Engineer DS/dh Attachment cc: Florida Transportation Builders' Assoc. State, , shared use paths, etc.). constructed in accordance with Standard Plans, Index 522-002. 527-2, of truncated domes aligned in parallel rows in accordance with Standard Plans, Index 522-002. Do, in accordance with the following: PROPERTY STANDARD TEST VALUE Slip Resistance FM 3-C1028 Dry
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/january-2022/review/fhwa/5270100-122fhwa.pdf?sfvrsn=bce4984_29710700.origind
not been any products that want to qualify as Standard Tape. Summary of the changes: Eliminated the category and references to Standard Tape. Are these changes applicable to all Department jobs? Yes, these changes? Specifications, Construction and Maintenance What other offices will be impacted, Specifications Office for assistance in completing this form. Frances Thomas 850-414-4101, 19, 2013 TO: Specification Review Distribution List FROM: Daniel Scheer, P.E., State Specifications
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/january-2014/review/internal/9710700.origind.pdf?sfvrsn=b91b2781_0400-010IntReviewPkg
Affected (Yes/No) Other Standard Plans No FDOT Design Manual No Standard Specifications No Basis, Origination Form Proposed Revisions to a Standard Plans Index Originator: Turley, Joshua Index, "Work with Specifications 400 and 415. See the Retaining Wall Control Drawings and Data Tables, No Implementation ["FY-Standard Plans (Next Release)"] 9 / 1 0 / 2 0 2 4 1 1 : 2 6 : 5 1 A M R E V I S I O N DESCRIPTION: REVISION LAST of STANDARD PLANS FY 2025-26 SHEET INDEX
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/irr/2027/400-010intreviewpkg.pdf?sfvrsn=401ad53e_1400-010IndReviewPkg
Affected (Yes/No) Other Standard Plans No FDOT Design Manual No Standard Specifications No Basis, Origination Form Proposed Revisions to a Standard Plans Index Originator: Turley, Joshua Index, "Work with Specifications 400 and 415. See the Retaining Wall Control Drawings and Data Tables, No Implementation ["FY-Standard Plans (Next Release)"] 9 / 1 0 / 2 0 2 4 1 1 : 2 6 : 5 1 A M R E V I S I O N DESCRIPTION: REVISION LAST of STANDARD PLANS FY 2025-26 SHEET INDEX
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/irr/2027/400-010indreviewpkg.pdf?sfvrsn=da6579f7_1FM1-T310
as per subsection 120-10.1.1 of the Department’s Standard Specifications for Road and Bridge, and Soil Aggregates by Nuclear Methods Designation: FM 1-T310 This standard supersedes former FM, referenced within. ASTM D6938 - Standard Test Methods for In-Place Density and Water Content of Soil, - Standard Test Method for In-Place Bulk Density of Soil and Soil- Aggregate by a Low-Activity, on meeting Department Specifications and having a proven history of reliable results. 5.2 Reference
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/materials/administration/resources/library/publications/fstm/methods/fm1-t310.pdf?sfvrsn=40ad05d8_2SPM5360100 InternalCommentResponses
and responses are verbatim as received. The Specifications Office does not alter typos or grammar.) BLACK = Comment BLUE = Specifications Response GREEN = Change Made to Specification Name: James Read, of the guardrail and end treatments and extending out as far as required per Standard Plans or Manufacturer Specifications. RESPONSE: The intent of this revision is to establish a method of measurement
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2025-26/maintenance/comments-responses/spm5360100-internalcommentresponses.pdf?sfvrsn=5441f4c7_16410500-722origind
ORIGINATION FORM Proposed Revisions to the Specifications (Please provide all information - incomplete forms will be returned) Contact the State Specifications Office for assistance in completing this form. Daniel Strickland 850-414-4130 Daniel.Strickland@dot.state.fl.us Rebecca Arcia, : Will the proposed revision require changes to: Publication Yes No Office Staff Contacted Standard Plans, , State Specifications Engineer SUBJECT: Proposed Specification: 6410500 Prestressed Concrete Poles
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/internal/6410500-722origind.pdf?sfvrsn=5724509d_23371100-722origind
ORIGINATION FORM Proposed Revisions to the Specifications (Please provide all information - incomplete forms will be returned) Contact the State Specifications Office for assistance in completing this form. Daniel Strickland 850-414-4130 Daniel.Strickland@dot.state.fl.us Rebecca Arcia, : Will the proposed revision require changes to: Publication Yes No Office Staff Contacted Standard Plans, , State Specifications Engineer SUBJECT: Proposed Specification: 3371100 Asphalt Concrete Friction
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/internal/3371100-722origind.pdf?sfvrsn=c89238d_21040400-722origind
ORIGINATION FORM Proposed Revisions to the Specifications (Please provide all information - incomplete forms will be returned) Contact the State Specifications Office for assistance in completing this form. Daniel Strickland 850-414-4130 Daniel.Strickland@dot.state.fl.us Rebecca Arcia, : Will the proposed revision require changes to: Publication Yes No Office Staff Contacted Standard Plans, , State Specifications Engineer SUBJECT: Proposed Specification: 1040400 Prevention, Control
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/internal/1040400-722origind.pdf?sfvrsn=4c439002_21600405-722origind
ORIGINATION FORM Proposed Revisions to the Specifications (Please provide all information - incomplete forms will be returned) Contact the State Specifications Office for assistance in completing this form. Daniel Strickland 850-414-4130 Daniel.Strickland@dot.state.fl.us Rebecca Arcia, : Will the proposed revision require changes to: Publication Yes No Office Staff Contacted Standard Plans, , State Specifications Engineer SUBJECT: Proposed Specification: 1600405 Stabilizing. In accordance
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/internal/1600405-722origind.pdf?sfvrsn=2bbf9018_45200100-722origind
ORIGINATION FORM Proposed Revisions to the Specifications (Please provide all information - incomplete forms will be returned) Contact the State Specifications Office for assistance in completing this form. Daniel Strickland 850-414-4130 Daniel.Strickland@dot.state.fl.us Rebecca Arcia, : Will the proposed revision require changes to: Publication Yes No Office Staff Contacted Standard Plans, , State Specifications Engineer SUBJECT: Proposed Specification: 5200100 Concrete Gutter, Curb
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/internal/5200100-722origind.pdf?sfvrsn=3e19d2de_24551206-722origind
ORIGINATION FORM Proposed Revisions to the Specifications (Please provide all information - incomplete forms will be returned) Contact the State Specifications Office for assistance in completing this form. Daniel Strickland 850-414-4130 Daniel.Strickland@dot.state.fl.us Rebecca Arcia, : Will the proposed revision require changes to: Publication Yes No Office Staff Contacted Standard Plans, , State Specifications Engineer SUBJECT: Proposed Specification: 4551206 Structures Foundations
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/internal/4551206-722origind.pdf?sfvrsn=f4975f72_22340900-722origind
ORIGINATION FORM Proposed Revisions to the Specifications (Please provide all information - incomplete forms will be returned) Contact the State Specifications Office for assistance in completing this form. Daniel Strickland 850-414-4130 Daniel.Strickland@dot.state.fl.us Rebecca Arcia, : Will the proposed revision require changes to: Publication Yes No Office Staff Contacted Standard Plans, , State Specifications Engineer SUBJECT: Proposed Specification: 2340900 Superpave Asphalt Base
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/internal/2340900-722origind.pdf?sfvrsn=1040e500_26820202-722origind
ORIGINATION FORM Proposed Revisions to the Specifications (Please provide all information - incomplete forms will be returned) Contact the State Specifications Office for assistance in completing this form. Daniel Strickland 850-414-4130 Daniel.Strickland@dot.state.fl.us Rebecca Arcia, : Will the proposed revision require changes to: Publication Yes No Office Staff Contacted Standard Plans, , State Specifications Engineer SUBJECT: Proposed Specification: 6820202 Video Equipment
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/internal/6820202-722origind.pdf?sfvrsn=b50afd72_23340700-722origind
ORIGINATION FORM Proposed Revisions to the Specifications (Please provide all information - incomplete forms will be returned) Contact the State Specifications Office for assistance in completing this form. Daniel Strickland 850-414-4130 Daniel.Strickland@dot.state.fl.us Rebecca Arcia, : Will the proposed revision require changes to: Publication Yes No Office Staff Contacted Standard Plans, , State Specifications Engineer SUBJECT: Proposed Specification: 3340700 Superpave Asphalt Concrete
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/internal/3340700-722origind.pdf?sfvrsn=256d56b4_24460400-722origind
ORIGINATION FORM Proposed Revisions to the Specifications (Please provide all information - incomplete forms will be returned) Contact the State Specifications Office for assistance in completing this form. Daniel Strickland 850-414-4130 Daniel.Strickland@dot.state.fl.us Rebecca Arcia, : Will the proposed revision require changes to: Publication Yes No Office Staff Contacted Standard Plans, , State Specifications Engineer SUBJECT: Proposed Specification: 4460400 Edgedrain (Draincrete
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/internal/4460400-722origind.pdf?sfvrsn=4708bf6_26491000-722origind
ORIGINATION FORM Proposed Revisions to the Specifications (Please provide all information - incomplete forms will be returned) Contact the State Specifications Office for assistance in completing this form. Daniel Strickland 850-414-4130 Daniel.Strickland@dot.state.fl.us Rebecca Arcia, : Will the proposed revision require changes to: Publication Yes No Office Staff Contacted Standard Plans, , State Specifications Engineer SUBJECT: Proposed Specification: 6491000 Galvanized Steel Poles, Mast
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/internal/6491000-722origind.pdf?sfvrsn=e64ed4eb_2