9185 search results for test

1250009SSFHWA

and testing at a minimum frequency of one test per soil type. The Verification test will be at a minimum of one test per soil type: Test Name Quality Control Verification Standard Proctor Maximum, will perform Resolution testing. The material will be sampled and tested in accordance with AASHTO T 99, Method C. TheEngineerwillcompare the Resolution test result with the Quality Control test, results if the results compare within 4.5 PCF [72 kg/m 3 ] of the Verification test result

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan05/files/1250009ssfhwa.pdf?sfvrsn=4fc2f99d_0

3460000.comm

properties tests as soon as the test results are known. Perform slump tests on all trucks that arrive, sampling and testing or performing the verification tests. The Materials Manual does not limit, and verification “hold” cylinders are tested within seven days of the acceptance strength tests.” I’m not sure, to be tested outside of the 42 days. The allowance to test cores outside of the specified timeframe, temperature of the slump loss test. This could dictate several slump loss tests to complete a single day

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan13/files/3460000-comm.pdf?sfvrsn=9065da8d_4

CR-07A (18-19) (Clean)

testing in accordance with the requirements specified in 334- 5.5.1 and the same sample verification testing as specified in 334-5.5.2 in order to determine the validity of the Contractor’s QC test, by the failing test result shall be evaluated in accordance with 334-5.9.5. If two consecutive QC tests, Technician is aware of and enforcing the requirements that when an individual QC test result of a sublot, resolved and the material represented by the failing test result shall be evaluated in accordance

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/construction/constadm/guidelist/criticalreq/fy1819/cr-07a-(18-19)-(clean).pdf?sfvrsn=5e46fada_0

1250816.fhwa

of one LOT. Perform five QC tests at random locations within the test section. All five tests must, of 125-9.2 or when the QC tests cannot be verified, construct a new test section. The Contractor may, section of the length of one LOT. Perform five QC tests at random locations within the test, test fails the requirements of 125-9.2 or when the QC tests cannot be verified, construct a new test, Envelope if he can demonstrate with a successful test section that density can be achieved. Notify

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul08/files/1250816.fhwab99e02c2eec144ff949f81d56ee73874.pdf?sfvrsn=bce75241_0

1250816.FHWA

of one LOT. Perform five QC tests at random locations within the test section. All five tests must, of 125-9.2 or when the QC tests cannot be verified, construct a new test section. The Contractor may, section of the length of one LOT. Perform five QC tests at random locations within the test, test fails the requirements of 125-9.2 or when the QC tests cannot be verified, construct a new test, Envelope if he can demonstrate with a successful test section that density can be achieved. Notify

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul08/files/1250816.fhwa.pdf?sfvrsn=50d02a69_0

1600100FHWA

by the SMO will perform Resolution testing. If the Resolution test results satisfy the required, Testing: Perform soil classification tests on the sample collected in 160-4.2.1.2, in accordance, ). The following testing requirements must be met. Table 160-3 Test Method Criteria AASHTO M145 Soil, Resolution testing on the additional sample. The material will be sampled and tested in accordance, Classification and Organic Content Testing: Perform soil classification tests on the sample collected

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2026-27/review/fhwa/1600100fhwa.pdf?sfvrsn=4a3c6a5f_1

3501600.comm

test cylinders, made in accordance with ASTM C 31 and tested in accordance with ASTM C 39, . joshua.carter@gbfinc.net (863)284-1090 Comments: If cylinders are to be tested rather than beams, shouldn’t, Bowles tom.b@russellengineering.com Comments: I do not know the content of the ASTM Test procedure, at an earlier time provided that representative test beams cylinders, made in accordance with ASTM C 31 and tested in accordance with ASTM C 7839, indicate a flexural COMPRESSIVE strength of at least 550

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul08/files/3501600.comm.pdf?sfvrsn=127dd046_0

1050404-MM84VII.resp

dmoody@seminoleprecast.com Comments: (4-27-17) My concerns are with the addition of three new tests to every lot, . By adding these test we are taking away valuable time that could be used pouring. I also have concerns with having to buy new testing equipment for the field that is normally used only in the lab, and is a process that is not currently taught in the ACI Concrete Field Technician Test. I have concerns about having an ACI certified tech performing tests that are not covered in the training. I believe

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/january-2018/review/comments-responses/1050404-mm84vii.resp.pdf?sfvrsn=a8197ca2_0

4600604-724FHWA

shall be tested. Perform Magnetic Particle Testing at the following frequencies: A minimum of 25, shall be tested. Perform Magnetic Particle Testing at the following frequencies: A minimum of 25, ultrasonic testing (UT) or radiographic testing (RT) on full penetration groovecomplete joint, . If discontinuities are found in the joint, the remainder of the joint shall be tested. Perform Magnetic Particle Testing at the following frequencies: A minimum of 25% of all fillet or partial penetration

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/fhwa/4600604-724fhwa.pdf?sfvrsn=e9e8acb_1

4551604-723impl

tests and other testing, or observes problems during drilled shaft construction, core the shaft, to satisfactorily perform the testing. When a shaft contains four tubes, test every possible tube, based on the CSL test and other testing, core the shaft to allow further evaluation and repair, is deleted and the following substituted: 455-16.4 Nondestructive Integrity Testing Access Tubes, top of shaft to allow thermal integrity testing for drilled shafts (TITDS) and cross-hole sonic

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/implemented/4551604-723impl.pdf?sfvrsn=42689d34_1

4551604-723origind

on the TITDS tests and other testing, or observes problems during drilled shaft construction, core the shaft, Specialty Engineer to satisfactorily perform the testing. When a shaft contains four tubes, test every, tube pair tested with any defect zones identified on the logs and discussed in the test report, a drilled shaft is unacceptable based on the CSL test and other testing, core the shaft to allow, : 455-16.4 Nondestructive Integrity Testing Access Tubes: Install access tubes full length in all

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/internal/4551604-723origind.pdf?sfvrsn=87196184_1

9160000.FHWA

be reported for the tests in the table below, unless noted otherwise. Quality control (QC) testing, be reported for the tests in the table below, unless noted otherwise. Quality control (QC) testing results, , in addition to the above, producers shall include a report of test results from an independent laboratory confirming the material meets the requirements of this section. In lieu of submitting test, Evaluation Section. Any marked variation from the original test values for a material below

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2019/january-2019/review/fhwa/9160000.fhwa.pdf?sfvrsn=f230dc49_0

Section92V2-723

American Society for Testing and Materials (ASTM) Standard Test Methods and Specifications, . The strength test data represents either a group of at least 30 consecutive tests or a statistical, psi. The strength test data represents either a group of at least 30 consecutive tests, at least 48 hours before performing such tests. Perform slumpslump/slump flow loss testing of the drilled, changes, provide uniformity test data, based on ASTM C94 testing. The metal rating plates must

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/materials-manual/redline/section92v2-723.pdf?sfvrsn=1f3da414_1

9930202.impl

Performance: Posts shall be tested and evaluated according to the National Testing Product Evaluation, . The yellowness index shall not exceed 12 when tested in accordance with ASTM D 1925 or ASTM E 313. The daylight 45 degree, 0 degree luminous directional reflectance shall be a minimum of 70 when tested

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan11/files/9930202.impl.pdf?sfvrsn=de45ea14_0

9920012SS

connectors shall be fault tested by applying a test current of .l,000 amperes, 60 HZ, for a minimum, of -40 to 190ºF [-40 to 85ºC]. Hardness of the molded rubber shall be 65 durometer. 992-12.2.1 Testing, and the protective ground conductor. When tested at the rated operating voltage, the leakage current, current measured between the primary conductors and the foil wrap. When tested at the rated operating voltage, the leakage current shall not exceed 0.5 mA. Flame Retardant Test - Flammability

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2006/january-2006/workbook/9920012ss.pdf?sfvrsn=6f896469_0

9920012SP

. FaultTest-Themated connectors shall be fault tested by applying a test current of .l,000 amperes, 60 HZ, . 992-12.2.1 Testing and Performance Criteria: The system shall pass the following performance criteria, conductors and the protective ground conductor. When tested at the rated operating voltage, and the leakage current measured between the primary conductors and the foil wrap. When tested at the rated operating voltage, the leakage current shall not exceed 0.5 mA. Flame Retardant Test

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2005/files/9920012sp.pdf?sfvrsn=9b344409_0

9920012SS

connectors shall be fault tested by applying a test current of .l,000 amperes, 60 HZ, for a minimum, of -40 to 190ºF [-40 to 85ºC]. Hardness of the molded rubber shall be 65 durometer. 992-12.2.1 Testing, and the protective ground conductor. When tested at the rated operating voltage, the leakage current, current measured between the primary conductors and the foil wrap. When tested at the rated operating voltage, the leakage current shall not exceed 0.5 mA. Flame Retardant Test - Flammability

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2006/january-2006/workbook/9920012ss8b9ed7b827ff4591a08bcd4d914f114d.pdf?sfvrsn=cb0570f2_0

9160201.impl

/URLinSpecs/Section35V2.shtm. 916-2.3 Reporting: Specification compliance testing results shall be reported for the tests in the table below, unless noted otherwise. Quality control (QC) testing results shall be reported, test temperature at 10 rad/sec. for the Dynamic Shear Rheometer (DSR) test (AASHTO T 315-12) shall, . 2.AnadditionalhightemperaturegradeofPG67isaddedforwhichthehightest temperature at 10 rad/sec for the DSR test (AASHTO T 315-12) shall be 67ºC, a vacuum tower and have an initial boiling point of 385°C (725°F) or lower when tested

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2017/january-2017/review/implemented/9160201.impl.pdf?sfvrsn=69bff517_0

SS6110000

results from the other tests listed in 611-4. Forty-Eight Hour Test for Traffic Signal installations, , the Engineer will require the satisfactory completion of all field tests of completed installations, satisfactory completion of all field tests of completed installations in accordance with the requirements, otherwise in writing by the Engineer. 611-4 Field Tests of Installations. Perform the following tests, to accept maintenance responsibility. Continuity: Test each signal head circuit, pedestrian detector

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2012/files/ss6110000.pdf?sfvrsn=8da9c926_0

SS6110000

results from the other tests listed in 611-4. Forty-Eight Hour Test for Traffic Signal installations, , the Engineer will require the satisfactory completion of all field tests of completed, satisfactory completion of all field tests of completed installations in accordance with the requirements, otherwise in writing by the Engineer. 611-4 Field Tests of Installations. Perform the following tests, to accept maintenance responsibility. Continuity: Test each signal head circuit, pedestrian detector

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2011/files/ss6110000.pdf?sfvrsn=41c7b75a_0
20 of 9185 results