8976 search results for test
1250009SSFHWA
and testing at a minimum frequency of one test per soil type. The Verification test will be at a minimum of one test per soil type: Test Name Quality Control Verification Standard Proctor Maximum, will perform Resolution testing. The material will be sampled and tested in accordance with AASHTO T 99, Method C. TheEngineerwillcompare the Resolution test result with the Quality Control test, results if the results compare within 4.5 PCF [72 kg/m 3 ] of the Verification test result
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan05/files/1250009ssfhwa.pdf?sfvrsn=4fc2f99d_09930202.impl
Performance: Posts shall be tested and evaluated according to the National Testing Product Evaluation, . The yellowness index shall not exceed 12 when tested in accordance with ASTM D 1925 or ASTM E 313. The daylight 45 degree, 0 degree luminous directional reflectance shall be a minimum of 70 when tested
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan11/files/9930202.impl.pdf?sfvrsn=de45ea14_01600100FHWA
by the SMO will perform Resolution testing. If the Resolution test results satisfy the required, Testing: Perform soil classification tests on the sample collected in 160-4.2.1.2, in accordance, ). The following testing requirements must be met. Table 160-3 Test Method Criteria AASHTO M145 Soil, Resolution testing on the additional sample. The material will be sampled and tested in accordance, Classification and Organic Content Testing: Perform soil classification tests on the sample collected
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2026-27/review/fhwa/1600100fhwa.pdf?sfvrsn=4a3c6a5f_1CR-07A (18-19) (Clean)
testing in accordance with the requirements specified in 334- 5.5.1 and the same sample verification testing as specified in 334-5.5.2 in order to determine the validity of the Contractor’s QC test, by the failing test result shall be evaluated in accordance with 334-5.9.5. If two consecutive QC tests, Technician is aware of and enforcing the requirements that when an individual QC test result of a sublot, resolved and the material represented by the failing test result shall be evaluated in accordance
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/construction/constadm/guidelist/criticalreq/fy1819/cr-07a-(18-19)-(clean).pdf?sfvrsn=5e46fada_0FDOT Recruitment: Get On Board
. Testimonials Ann Mary Thekanal Right of Way Agent I
https://www.fdot.gov/agencyresources/employment.shtmSS3300000
not suitable for testing with the Laser Profiler will be tested and accepted with the straightedge, Minimum Process Control Testing Requirements: Perform, as a inimu,thefoll mmng activities at the testing frequencies provided below: Asphalt Plant 1.AsphaltMix:Determine the asphalt binder content, Test one sample per 1000 tons of incoming material (prior ple ut ntractor) for rocessontro that the daily production exceeds 1,000 tons, perform these tests a minimum of two tim per day. Quality
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2010/files/ss3300000.pdf?sfvrsn=5f7888b9_04551604-723origind
on the TITDS tests and other testing, or observes problems during drilled shaft construction, core the shaft, Specialty Engineer to satisfactorily perform the testing. When a shaft contains four tubes, test every, tube pair tested with any defect zones identified on the logs and discussed in the test report, a drilled shaft is unacceptable based on the CSL test and other testing, core the shaft to allow, : 455-16.4 Nondestructive Integrity Testing Access Tubes: Install access tubes full length in all
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/internal/4551604-723origind.pdf?sfvrsn=87196184_14551604-723impl
tests and other testing, or observes problems during drilled shaft construction, core the shaft, to satisfactorily perform the testing. When a shaft contains four tubes, test every possible tube, based on the CSL test and other testing, core the shaft to allow further evaluation and repair, is deleted and the following substituted: 455-16.4 Nondestructive Integrity Testing Access Tubes, top of shaft to allow thermal integrity testing for drilled shafts (TITDS) and cross-hole sonic
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/implemented/4551604-723impl.pdf?sfvrsn=42689d34_11050404-MM84VII.resp
dmoody@seminoleprecast.com Comments: (4-27-17) My concerns are with the addition of three new tests to every lot, . By adding these test we are taking away valuable time that could be used pouring. I also have concerns with having to buy new testing equipment for the field that is normally used only in the lab, and is a process that is not currently taught in the ACI Concrete Field Technician Test. I have concerns about having an ACI certified tech performing tests that are not covered in the training. I believe
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/january-2018/review/comments-responses/1050404-mm84vii.resp.pdf?sfvrsn=a8197ca2_09160000.FHWA
be reported for the tests in the table below, unless noted otherwise. Quality control (QC) testing, be reported for the tests in the table below, unless noted otherwise. Quality control (QC) testing results, , in addition to the above, producers shall include a report of test results from an independent laboratory confirming the material meets the requirements of this section. In lieu of submitting test, Evaluation Section. Any marked variation from the original test values for a material below
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2019/january-2019/review/fhwa/9160000.fhwa.pdf?sfvrsn=f230dc49_01250816.fhwa
of one LOT. Perform five QC tests at random locations within the test section. All five tests must, of 125-9.2 or when the QC tests cannot be verified, construct a new test section. The Contractor may, section of the length of one LOT. Perform five QC tests at random locations within the test, test fails the requirements of 125-9.2 or when the QC tests cannot be verified, construct a new test, Envelope if he can demonstrate with a successful test section that density can be achieved. Notify
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul08/files/1250816.fhwab99e02c2eec144ff949f81d56ee73874.pdf?sfvrsn=bce75241_01250816.FHWA
of one LOT. Perform five QC tests at random locations within the test section. All five tests must, of 125-9.2 or when the QC tests cannot be verified, construct a new test section. The Contractor may, section of the length of one LOT. Perform five QC tests at random locations within the test, test fails the requirements of 125-9.2 or when the QC tests cannot be verified, construct a new test, Envelope if he can demonstrate with a successful test section that density can be achieved. Notify
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul08/files/1250816.fhwa.pdf?sfvrsn=50d02a69_09160201.impl
/URLinSpecs/Section35V2.shtm. 916-2.3 Reporting: Specification compliance testing results shall be reported for the tests in the table below, unless noted otherwise. Quality control (QC) testing results shall be reported, test temperature at 10 rad/sec. for the Dynamic Shear Rheometer (DSR) test (AASHTO T 315-12) shall, . 2.AnadditionalhightemperaturegradeofPG67isaddedforwhichthehightest temperature at 10 rad/sec for the DSR test (AASHTO T 315-12) shall be 67ºC, a vacuum tower and have an initial boiling point of 385°C (725°F) or lower when tested
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2017/january-2017/review/implemented/9160201.impl.pdf?sfvrsn=69bff517_09920012SP
. FaultTest-Themated connectors shall be fault tested by applying a test current of .l,000 amperes, 60 HZ, . 992-12.2.1 Testing and Performance Criteria: The system shall pass the following performance criteria, conductors and the protective ground conductor. When tested at the rated operating voltage, and the leakage current measured between the primary conductors and the foil wrap. When tested at the rated operating voltage, the leakage current shall not exceed 0.5 mA. Flame Retardant Test
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2005/files/9920012sp.pdf?sfvrsn=9b344409_09920012SS
connectors shall be fault tested by applying a test current of .l,000 amperes, 60 HZ, for a minimum, of -40 to 190ºF [-40 to 85ºC]. Hardness of the molded rubber shall be 65 durometer. 992-12.2.1 Testing, and the protective ground conductor. When tested at the rated operating voltage, the leakage current, current measured between the primary conductors and the foil wrap. When tested at the rated operating voltage, the leakage current shall not exceed 0.5 mA. Flame Retardant Test - Flammability
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2006/january-2006/workbook/9920012ss8b9ed7b827ff4591a08bcd4d914f114d.pdf?sfvrsn=cb0570f2_09920012SS
connectors shall be fault tested by applying a test current of .l,000 amperes, 60 HZ, for a minimum, of -40 to 190ºF [-40 to 85ºC]. Hardness of the molded rubber shall be 65 durometer. 992-12.2.1 Testing, and the protective ground conductor. When tested at the rated operating voltage, the leakage current, current measured between the primary conductors and the foil wrap. When tested at the rated operating voltage, the leakage current shall not exceed 0.5 mA. Flame Retardant Test - Flammability
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2006/january-2006/workbook/9920012ss.pdf?sfvrsn=6f896469_06330201-724FHWA
tests at 1,310 and 1,550 nanometer wavelengths and include the last calibration date of all test, and termination tested to the Engineer in an approved electronic format. Ensure all OTDR testing, to commencement of testing. Perform all tests at 1,310 and 1,550 nanometer wavelengths and include the last, the tensile load is removed. Ensure that optical fiber is proof-tested by the fiber manufacturer, and the change in attenuation does not exceed 0.2 decibel at 6330201 1,550 nanometers when tested
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/fhwa/6330201-724fhwa.pdf?sfvrsn=4f1ec305_19600202comm
This testing criteria has been revised multiple times over the evolution of the Florida DOT specifications: 1. 9-26-2002 Revision on 2-20-2003 “Test the finished material for these ancillary items, an endurance rating of not less than 192 hours”. 2. Revision 5-7-2003 Test the finished material, . Revision 10-15-2003 Test the finished polyolefin material for stress crack resistance using ASTM F, . Revision 5-7-2004 Test the remolded finished polyolefin material for stress crack resistance using
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul19/files/9600202comm.pdf?sfvrsn=1418270b_29850000.comm
, it can then be tested as a system to do the job for which it is designed. It should be tested under full scale testing procedures as listed by NTPEP as TM 11340 (Test method for determination, third party testing. Response: 4. Section 985-3.2 In lieu of the manufacturer’s “test records, Comment: (7-17-14) Section 985, you address geotextiles with various subtitles. Table 2 refers to test, of the system. A true test of a product cannot be made without considering the combination of materials
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2015/january-2015/review/comments-responses/9850000.comm.pdf?sfvrsn=dd0c41a2_09940201-724IMPL
evaluation of their products need to submit product data sheets, performance test reports from, inks and overlay materials shall be tested in accordance with, and meet all the performance, included in the APL application shall be tested and meet the requirements identified in ASTM D4956, will be tested as a system consisting of white base sheeting and each color of ink and/or overlay. Panels for testing sheeting shall be prepared in accordance with 994-3 for testing. The in-service life
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/implemented/9940201-724impl.pdf?sfvrsn=d44e8955_1