13229 search results for DESIGN

444-T01

SPECIAL MANHOLE STRUCTURE A A to verify design capacity. as specified in plans. Contractor, of Casing Varies, 60' min. 1. DESIGN NOTES:

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/idx/444-t01.pdf?sfvrsn=b9f5c8c0_1

Exhibit 913-8

BASE GROUP 1 CONTEXT CLASSIFICATION = N/A DESIGN SPEED = 30 MPH K = 10% D = 100% T = 8% (24 HOUR) ESTIMATED DESIGN YEAR = 2040 AADT = 12,000 ESTIMATED OPENING YEAR = 2020 AADT = 8,800 = 2018 AADT

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/2025/exhibit-913-8.pdf?sfvrsn=638fb648_1

Exhibit 913-10

TRAFFIC DATA CONTEXT CLASSIFICATION = N/A DESIGN HOUR T = 1% K = 6% D = 55% T = 2% (24 HOUR) ESTIMATED DESIGN YEAR = 2040 AADT = 30600 ESTIMATED OPENING YEAR = 2020 AADT = 25800 CURRENT YEAR = 2018

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/2025/exhibit-913-10.pdf?sfvrsn=9eaf2cca_1

ADA Related Links

are to be applied during the design, construction, additions to, and alterations of facilities, Standards for Accessible Design. Florida Accessibility CodeAt this link, click on “Florida Building

https://www.fdot.gov/roadway/ada/adalinks.shtm

FDOTConnectOBMPlaceRebarTableWorkflow

to the Place Ta ble tool. Yo u can also place the table in a design or drawing model if desired. 1. Hit, . If using this method, the table should be placed in a design model, broken up with a table break

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/cadd/downloads/documentation/fdotconnecttraining/obm/fdotconnectobmplacerebartableworkflow.pdf?sfvrsn=ea8610ce_1

E8U72Addenda003

SHEET 314 TEMP. PIPE ADDED 334 REMOVED LABEL 336 DRAINAGE TEXT & DESIGN UPDATED 337 DRAINAGE TEXT & DESIGN UPDATED 338 DRAINAGE TEXT & DESIGN UPDATED 340 DRAINAGE TEXT & DESIGN UPDATED 341 DRAINAGE TEXT & DESIGN UPDATED 342 REMOVED LABEL 343 TEMP. DRAINAGE LABELS & TABLE ADDED 344 REVISED TEMP WALL, TEMP. DRAINAGE LABELS & TABLE ADDED 345 DRAINAGE TEXT & DESIGN UPDATED 346 TEMP, AND LABELS ADDED 350 DRAINAGE PIPES REMOVED 351 TEMP. DRAINAGE UPDATED 352 DRAINAGE TEXT & DESIGN

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/tp/lettings/2024/dec09/e8u72addenda003.pdf?sfvrsn=6597c64a_1

Email-Access MangtCoordin-21stSt-2023-07-27

not agree to combine the driveways so there are no signal heads for NB. Design will need to follow up, Department of Transportation 3 Engineering, Design and Project Management Tel: 863.800.9549, Cell

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/procuement_marketingd1/documents/fy-25-26/ad--26106/email-access-mangtcoordin-21stst-2023-07-27.pdf?sfvrsn=de465cce_1

SR 869/SW 10th Street Connector from Florida-s Turnpike/Sawgrass Expressway to SR 9/I-95 - DRAFT

) is in the preliminary design phase for the SW 10th Street Connector Project. FDOT will continue its close, and residential property owners in the area, and other interested stakeholders, throughout the design

https://www.fdot.gov/projects/sr869-sw10st-i95/sr-869-sw-10th-street-connector-from-florida-s-turnpike-sawgrass-expressway-to-sr-9-i-95---draft

QF-635-01-1 ANSI SCTE 77 6.2-7.7 Checklist

Document Review FORMTEXT       FORMTEXT       Init.: FORMTEXT       17 Design load of 2400 lbs, deflection. Document Review FORMTEXT       FORMTEXT       Init.: FORMTEXT       21 Design load, .: FORMTEXT       29 For Tier 15: A design load of 66.7 kN (15000 lbs) is applied to the enclosure ten times and the corresponding deflections of each cycle are recorded. For Tier 22: A design load,       FORMTEXT       Init.: FORMTEXT       36 For Tier 15: A design load of 66.7 kN (15000 lbs) is applied

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/traffic/traf_sys/compliance-matrices-2022/qf-635-01-1-ansi-scte-77-6-2-7-7-checklist.docx?sfvrsn=434ddfd3_1

SR 869/SW 10th Street Connector from Florida-s Turnpike/Sawgrass Expressway to SR 9/I-95

(FDOT) is in the preliminary design phase for the SW 10th Street Connector Project. FDOT, , throughout the design and construction of the SW 10th Street Connector improvement projects

https://www.fdot.gov/projects/sr869-sw10st-i95/index.shtm

Autonomous-Vehicle-Policy-Guide-for-PublicNOV2017

• Develop conceptual urban design guidance to showcase potential solutions for technology, and Implementation Guidance Task 5 – Conceptual Urban Design Guidance Task 6 – Interim Studio Report Task 7

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/mpoac_website/meetings/2017/autonomous-vehicle-policy-guide-for-publicnov2017.pdf?sfvrsn=3d9e0026_1

SP5500100redline

 SP5500100 All Maintenance Contracts FENCING. (REV 9-24-1428-15) (1-1516) ARTICLE 550-1 is expanded by the following: Remove and replace damaged, destroyed, or deteriorated posts and fence sections meeting the requirements of the Department’s Design Standards, and revisions thereto, current at the time of contract letting. Such work may include the removal of existing fence, removal, or Design Standards for each type and case. Thepayment for additional length of post will include

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/january-2016/maintenance/review-package/sp5500100redline.pdf?sfvrsn=1c111bd9_0

0050104FHWA

with the design shown in the Plans. Prepare all shop drawings using the same units of measure as those used, that are necessary to complete the structure in compliance with the design shown in the Plans. Prepare

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2025-26/review/fhwa/0050104fhwa.pdf?sfvrsn=d18fa1cb_1

9480901FHWA

in accordance with the AASHTO LRFD Bridge Design Specifications. Assume a fully deteriorated condition, Bridge Design Specifications. Assume a fully deteriorated condition with no structural strength from

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2025-26/review/fhwa/9480901fhwa.pdf?sfvrsn=ab7ea5fd_1

9670601FHWA

include relevant details for design and construction, such as quantity tables and the length of need, requirements of Standard Plans, Index 536-001. These drawings must include relevant details for design

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2025-26/review/fhwa/9670601fhwa.pdf?sfvrsn=20c9a7d_1

SP5500100

 FENCING. (REV 9-28-15) (1-16) ARTICLE 550-1 is expanded by the following: Remove and replace damaged, destroyed, or deteriorated posts and fence sections meeting the requirements of the Department’s Design Standards, and revisions thereto, current at the time of contract letting. Such work may include the removal of existing fence, removal of any public or private attachments to existing, in the Plans or Design Standards for each type and case. The payment for additional length of post

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/january-2016/maintenance/implemented/sp5500100.pdf?sfvrsn=860fed7c_1

Responses

occurred with agency during design/permitting to confirm if a permit would be required for the work, occurred with agency during design/permitting to confirm if a permit would be required for the work

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/january-2018/workbook/sp0070104-2resp.pdf?sfvrsn=8930aab2_0

9480203-724IMPL

 948 OPTIONAL DRAINAGE PRODUCTS AND REPAIR SYSTEMS (REV 8-4-23) (FA 11-6-23) (FY 2024-25) SUBARTICLE 948-2.3.2 is expanded by the following: 948-2.3.2 Additional Requirements for Class II (100-Year Design Service Life), Type S HDPE Pipe: Class II HDPE pipe shall meet the requirements in Table 948-1 in addition to those in 948-2.3. Perforations will not be allowed. Manufacturers may only, Additional Requirements for Class II (100-Year Design Service Life) PP Pipe: Meet the requirements

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/implemented/9480203-724impl.pdf?sfvrsn=fd90a127_1

3500200-722FHWA

Product List (APL). Submit a mix design to the Engineer for approval prior to use. Provide concrete, design to the Engineer for approval prior to use. For concrete pavement placed using the slip-form

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/fhwa/3500200-722fhwa.pdf?sfvrsn=514c7f01_2

3200603-722FHWA

Verified Mix Design Any Single Measurement ±25°F 3200603 All Jobs HOT MIX ASPHALT - PLANT METHODS, 320-3 Mix Temperature Tolerance from Verified Mix Design Any Single Measurement ±25°F

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/fhwa/3200603-722fhwa.pdf?sfvrsn=51a5e7b4_2
20 of 13229 results