3724 search results for fla
5600201-724IMPL
Type M coal tar or modified glass flake epoxy coatings meeting the requirements of Section 926, or modified glass flake epoxy coatings to the exposed side of sheet piles from the top of the piles, . Apply the coal tar or modified glass flake epoxy in accordance with the following specific requirements: 1. Apply the coal tar or modified glass flake epoxy system in strict accordance, thickness (zinc primer and coal tar epoxy) at a minimum 18 mils (on each side). Modified glass flake
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/implemented/5600201-724impl.pdf?sfvrsn=dc5cccb1_1Exhibit 210-2
EXISTING ROADWAY WITHOUT PAVED SHOULDERS CONNECTING FLARE WITH PAVED SHOULDERS TO CONNECTING SIMILAR WIDTH PAVEMENTS CONNECTING DIFFERENT WIDTH PAVEMENTS EXISTING SYMMETRICAL FLARE WITHOUT PAVED SHOULDERS CONNECTING ROADWAY WITH PAVED SHOULDERS TO EXISTING ASYMMETRICAL FLARE WITHOUT PAVED SHOULDERS CONNECTING ROADWAY WITH PAVED SHOULDERS TO FLARED - PAVED SHOULDERS 200' 200' 200' 200' L
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/2025/review/exhibit-210-2.pdf?sfvrsn=6bb6c024_1Exhibit 210-2
EXISTING ROADWAY WITHOUT PAVED SHOULDERS CONNECTING FLARE WITH PAVED SHOULDERS TO CONNECTING SIMILAR WIDTH PAVEMENTS CONNECTING DIFFERENT WIDTH PAVEMENTS EXISTING SYMMETRICAL FLARE WITHOUT PAVED SHOULDERS CONNECTING ROADWAY WITH PAVED SHOULDERS TO EXISTING ASYMMETRICAL FLARE WITHOUT PAVED SHOULDERS CONNECTING ROADWAY WITH PAVED SHOULDERS TO FLARED - PAVED SHOULDERS 200' 200' 200' 200' L
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/2025/exhibit-210-2.pdf?sfvrsn=3fc6e6f4_26700200.impl
controller, traffic controller accessories (including monitors, load switches, flasher, flash, of Section 676. 670-2.4 Flashing Intersection Control Beacon Controller Assembly: A flashing intersection control beacon controller assembly must consist of a Type 3 flasher wired into a Type 1
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/january-2018/review/implemented/6700200.impl.pdf?sfvrsn=6d0eb006_0F4009TechnicalSpecialProvisions
manufacturer. 3.6 FLASHING AND ACCESSORIES INSTALLATION A. Install flashings, including laps, splices, of flashing will not completely cover the metal flange, install additional piece of flashing to cover, . Scuppers: Set in sealant and secure to structure; flash as recommended by manufacturer. E. Flashing, clamping bolts to achieve constant compression. G. Flashing at Penetrations: Flash all penetrations, Supports, and Similar Items: Flash with specified pre -molded pipe flashings wherever practical
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d4/fcp/f4009/f4009technicalspecialprovisions.pdf?sfvrsn=96d9cd9c_1Formet
Formet FX Flared (27) - Drawings.pdf Formet FX Tangent (27) - Drawings.pdf
https://www.fdot.gov/contracts/district-offices/d5/lettings/dist-letting-project-info.shtm/lists/end-treatments/formetQuick Reference for Requesting Product Sample
Power Supply Unit Load Switches (16 each) Flasher Flash Transfer Relay or Model 430 Flash, ) Flasher Flash Transfer Relay Power Distribution Assembly Input File Time Switch Generator, of Traffic Automated Flagger Assistance Device (AFAD) Item with all options maximizing battery draw 1 system (2 AFADs) Freight on flatbed or towed For flatbed, written authorization from vendor, draw 1 each Freight on flatbed or towed For flatbed, written authorization from vendor to offload
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/traffic/traf_sys/procedural-docs-2022/quick-reference-for-requesting-product-sample.docx?sfvrsn=5120f4d6_1Invasive Species Program Information
;amp;amp;lt;p>Sorry, but you do not have the most current Flash Player plugin for viewing this Phone Directory. In order to view this Phone Directory you need to install Flash Player, ;Get Flash</a></p&gt
https://www.fdot.gov/maintenance/divisions.shtm/roadway/invasivespecies.shtm/invasivesinfo.shtmChapter_11
storage shall be permanently marked, “Hydrogen - Flammable Gas - No Smoking - No Open Flames.” [29 CFR, (d)(3)(ii)] (B) Safety cans or other portable containers of flammable liquids that have a flash, liquids having a flash point at or below 80º F, table containers of flammable liquids (open cup, liquids having a flash point at or below 80º F, table containers of flammable liquids (open cup, CFR 1910.107(g)(7)] 11.2.5 Maintenance Shop Signage (A) Flammable and combustible liquid storage
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/safety/industrialsafety/chapter_11.pdf?sfvrsn=49b454eb_11020916.FHWA
either by a single flagger at one end of the traffic control zone, from a central location, or by a separate flagger near each device’s location. Use only flaggers trained in accordance with Section, , the AFAD and the flagger are less than 800 feet apart. d4. Two flaggers are available on-site to provide, Strickland of the State Roadway Design Office to allow for the use of Automated Flagger Assistance, 102-9.16 is deleted and the following substituted: 102-9.16 Automated Flagger Assistance Devices (AFAD
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/july-2016/review/fhwa/1020916.fhwa.pdf?sfvrsn=fe7a9c2e_01020916.resp
Comments: (11-19-15) 102-9.16 "d4. Two flaggers are available on-site to provide normal flagging operations should an AFAD malfunction." As read this could be interpreted that you still need 2 flaggers, are less than less 800 feet apart. For one AFAD, the AFAD and the flagger are less than 800 feet, conditions under which only one flagger is needed. Is the intent rather to have a second certified flagger available from somewhere on the project to step in in case of malfunction? Response: Yes
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/july-2016/review/comments-responses/1020916.resp.pdf?sfvrsn=41fc565c_05600201-724FHWA
manufacturer. Use Type M coal tar or glass flake epoxy coatings meeting the requirements of Section 926, or glass flake -epoxy coatings to the exposed side of sheet piles from the top of the piles, . Apply the coal tar or glass flake -epoxy in accordance with the following specific requirements: 1.Apply the coal tar or glass flake -epoxy system in two coats. The time interval between the first, ) at a minimum 18 of the two coats between 16 and 20 mils (on each side). Glass flake epoxies must attain
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/fhwa/5600201-724fhwa.pdf?sfvrsn=b8da282_1SP0071104
or Flagging Services: The railroad company will furnish protective services (i.e., watchman or flagging, of flagging resources. Projects with less than 20 consecutive days of flagging services require a CSXT short-term flagger and 45 days written advance notice. Provide the 45 days written advance notice to the Engineer. Projects with 20 or more consecutive days of flagging services require a CSXT long term flagger. The Department will provide the 6 months written advance notice to CSXT
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/january-2016/workbook/sp0071104.pdf?sfvrsn=598a719b_2SP0071105
the Department can coordinate the scheduling of flagging resources. Projects with less than 20 consecutive days of flagging services require a CSXT short-term flagger and 45 days written advance notice. Provide, of flagging services require a CSXT long term flagger. The Department will provide the 6 months written, right-of-way. 7-11.5.3 Watchman or Flagging Services: The railroad company will furnish protective services (i.e., watchman or flagging services) to ensure the safety of railroad operations during
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2012/january-2012/workbook/sp0071105.pdf?sfvrsn=d5121c1f_0SP0071105
the Department can coordinate the scheduling of flagging resources. Projects with less than 20 consecutive days of flagging services require a CSXT short-term flagger and 45 days written advance notice. Provide, of flagging services require a CSXT long term flagger. The Department will provide the 6 months written, right of way. 7-11.5.3 Watchman or Flagging Services: The railroad company will furnish protective services (i.e., watchman or flagging services) to ensure the safety of railroad operations during
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2013/january-2013/workbook/sp0071105.pdf?sfvrsn=f033fd9c_0F4009Addendum003
cover the metal flange, install additional piece of flashing to cover the metal edge. 6. When, to structure; flash as recommended by manufacturer. E. Flashing at Walls, Curbs, and Other Vertical, compression. G. Flashing at Penetrations: Flash all penetrations passing through the membrane; make flashing seals directly to the penetration. 1. Pipes, Round Supports, and Similar Items: Flash, not exceed 12 inches, flash as for pipes; otherwise, provide a standard curb with flashing. 4. Flexible
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d4/fcp/f4009/f4009addendum003.pdf?sfvrsn=bfca206b_2102-600
flaggers are used, a FLAGGER symbol or legend sign must replace shall be used at night. Flashlight, as required sufficient to permit proper response by the motorist to the flagging The flagger must, turn lanes where two (2) flaggers are required Flag use is limited to immediate emergencies, by the Engineer. Devices include, but are not limited to, flaggers, portable temporary Adjust device, Flagger Work Survey 4 High-Visibility Widths Apparel Safety For Devices Control Work Overhead
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/idx/102-600.pdf?sfvrsn=71aa04ce_1102-600
flaggers are used, a FLAGGER symbol or legend sign must replace shall be used at night. Flashlight, as required sufficient to permit proper response by the motorist to the flagging The flagger must, lanes where two (2) flaggers are required Flag use is limited to immediate emergencies, by the Engineer. Devices include, but are not limited to, flaggers, portable temporary Adjust device, Flagger Work Survey 4 High-Visibility Widths Apparel Safety For Devices Control Work Overhead
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/idx/102-600.pdf?sfvrsn=5e00c8c6_2102-600E
flaggers are used, a FLAGGER symbol or legend sign must replace shall be used at night. Flashlight, as required sufficient to permit proper response by the motorist to the flagging The flagger must, lanes where two (2) flaggers are required Flag use is limited to immediate emergencies, by the Engineer. Devices include, but are not limited to, flaggers, portable temporary Adjust device, Flagger Work Survey 4 High-Visibility Widths Apparel Safety For Devices Control Work Overhead
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/idx/102-600e.pdf?sfvrsn=cd473a3e_1