4324 search results for fdot standard plans
SPI-649-020
Standard Plans Instructions Topic No. 625-010-003 Index 649-020 Steel CCTV Pole FY 2026-27 1 Index 649-020 Steel CCTV Pole Design Criteria AASHTO LRFD Specifications for Structural Supports, . Standard Plans Instructions Topic No. 625-010-003 Index 649-020 Steel CCTV Pole FY 2026-27 2 Plan Content Requirements Intelligent Transportation Systems (ITS) Plans: See FDM 942. Include poles, , FDOT Modifications to LRFDLTS-1; Structures Manual (SM) Introduction, I.6 References; FDOT Design
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2027/spi/spi-649-020.pdf?sfvrsn=cafe024a_1ChristianaHolmes-ProfilesVerticalGeometryTools
for roadway design and for plans development. For that reason we have created 2 new training manuals for SS4: 1. FDOT Roadway Design and 3D Modeling for SS4 2. FDOT Plans Development Wo r k flows, • Used to export chains and/or profiles to the GPK file for plans production. Viewing Existing, Standard Checks • Profile Reports Profile from Surface To o ls Profile by B e s t Fit Profile by V, ope From Element Quick Profile Tr a n s i t i o n Profile by 3 D Element Design Standard Checks
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/cadd/downloads/archived-documentations/christianaholmes-profilesverticalgeometrytools.pdf?sfvrsn=bd06b95d_2SPI-430-020
Standard Plans Instructions Topic No. 625-010-003 Index 430-020 Flared End Section FY 2024-25 1 Index 430-020 Flared End Section Design Criteria Drainage Manual (DM) ; FDOT Design Manual, and/or highly erosive soils may cause disjointing. Show location(s) of reinforced concrete jackets in Plans, disjointing would occur if the ditch pavement should fail. Show toe wall location(s) in the Plans. When, In the Roadway Plans: Summarize quantity by location in the Summary of Drainage Structures, Summary
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/spi/spi-430-020.pdf?sfvrsn=26ceaac1_2SPI-430-020
Standard Plans Instructions Topic No. 625-010-003 Index 430-020 Flared End Section FY 2025-26 1 Index 430-020 Flared End Section Design Criteria Drainage Manual (DM) ; FDOT Design Manual, and/or highly erosive soils may cause disjointing. Show location(s) of reinforced concrete jackets in Plans, disjointing would occur if the ditch pavement should fail. Show toe wall location(s) in the Plans. When, In the Roadway Plans: Summarize quantity by location in the Summary of Drainage Structures, Summary
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/spi/spi-430-020.pdf?sfvrsn=69f4a91e_1SPI-430-020
Standard Plans Instructions Topic No. 625-010-003 Index 430-020 Flared End Section FY 2026-27 1 Index 430-020 Flared End Section Design Criteria and Guidance Drainage Manual (DM) ; FDOT, jackets in Plans. Use toe walls whenever the anticipated velocity of discharge and soil type, ) in the Plans. When steel fiber-reinforcing is proposed as an alternative to the conventional reinforcing, Requirements In the Roadway Plans: Summarize quantity by location in the Summary of Drainage or Summary
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2027/spi/spi-430-020.pdf?sfvrsn=38d40b44_12024FDM914GenNotes
or curtail requirements in the Standard Specifications or Standard Plans . General notes, in the Standard Specifications and Standard Plans . Other rules to follow include: (1) Do, Topic #625-000-002 FDOT Design Manual 914 - General Notes 914 General Notes 914.1 General Place general notes on a 11” x 17” plan sheet available in the FDOT CADD Software. Place the General Notes sheet before the first roadway plan-profile sheet in the plans set. See Exhibit 914-1
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/2024/2024fdm914gennotes.pdf?sfvrsn=d4e7bbac_2Standard Plans - FY 2018-19 Errata
Standard Plans - FY 2018-19 Errata, Standard Plans - FY 2018-19 Errata The Standard Plans Indexes on the website have been updated to contain the Errata listed below. The only action, Standard Plans Index Number 700-020. 425-030 1 of 2 03/21/2018 Median Barrier Inlets Types 1 and 2 Added, Standard Plans Index Number 649-010. 649-031 2 of 6 09/20/2018 Mast Arm Assemblies Corrected Note 3, Helene, the Florida Department of Transportation (FDOT) is now focusing on supporting local
https://www.fdot.gov/design/standardplans/2019/Errata.shtm7150100-724FHWA
in the Standard Plans when standard aluminum pole assemblies or standard high mast light assemblies, mast lighting, with internal vibration damping devices in accordance with Standard Plans, Index, shown in the Plans. Use pole assemblies as shown in the Standard Plans when standard aluminum pole, , with internal vibration damping devices in accordance with Standard Plans, Index 715-002 in all, to remove the requirement to have oversight by FDOT audit program. Please review and transmit your
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/fhwa/7150100-724fhwa.pdf?sfvrsn=32953f64_17150100-724origind
Publications: Publication Yes No Office Staff Contacted Standard Plans Index Traffic Engineering Manual FDOT Design Manual ConstructionProject Administration Manual Basis of Estimate/Pay Items, shown in the Plans. Use pole assemblies as shown in the Standard Plans when standard aluminum pole assemblies or standard high mast light assemblies are required by the Contract Documents. Include, damping devices in accordance with Standard Plans, Index 715-002 in all installations on bridges
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/internal/7150100-724origind.pdf?sfvrsn=151aa814_11200603int
Affected: Other Affected Documents/Offices Contacted Yes/No Other Standard Plans Rick Jenkins/Shae, shoulder drop-off soil in accordance with Section 570 and Standard Plans 570-010. Meet the requirements, Origination Form Specifications Name: Jason Russell Standard Specification Section: 120 Email, . Establishing "Shoulder Dropoff Soil" within the Specification/Standard and giving guidance on it, to the Districts/Contractors. Which FDOT offices does the change impact? Design and Construction What
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2026-27/review/internal/1200603int.pdf?sfvrsn=b15a49cb_11200603ind
Affected: Other Affected Documents/Offices Contacted Yes/No Other Standard Plans Rick Jenkins/Shae, shoulder drop-off soil in accordance with Section 570 and Standard Plans 570-010. Meet the requirements, Origination Form Specifications Name: Jason Russell Standard Specification Section: 120 Email, . Establishing "Shoulder Dropoff Soil" within the Specification/Standard and giving guidance on it, to the Districts/Contractors. Which FDOT offices does the change impact? Design and Construction What
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2026-27/review/industry/1200603ind.pdf?sfvrsn=be9e872c_1570-010IntReviewPkg
Origination Form Proposed Revisions to a Standard Plans Index Originator: Gibbs, Shae Index, Construction office. Other Affected Documents/Offices Person Contacted Affected (Yes/No) Other Standard Plans No FDOT Design Manual Ben Gerrell Yes Standard Specifications Daniel Strickland Yes Basis, : 2 5 : 4 4 A M R E V I S I O N DESCRIPTION: REVISION LAST of STANDARD PLANS FY, O N DESCRIPTION: REVISION LAST of STANDARD PLANS FY 2026-27 SHEET INDEX Sod Width Per Plans
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/irr/2027/570-010intreviewpkg.pdf?sfvrsn=3ced1bd1_2570-010IndReviewPkg
Origination Form Proposed Revisions to a Standard Plans Index Originator: Gibbs, Shae Index, Construction office. Other Affected Documents/Offices Person Contacted Affected (Yes/No) Other Standard Plans No FDOT Design Manual Ben Gerrell Yes Standard Specifications Daniel Strickland Yes Basis, : 2 5 : 4 4 A M R E V I S I O N DESCRIPTION: REVISION LAST of STANDARD PLANS FY, N DESCRIPTION: REVISION LAST of STANDARD PLANS FY 2026-27 SHEET INDEX Sod Width Per Plans
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/irr/2027/570-010indreviewpkg.pdf?sfvrsn=1e8a7166_12025FDM913TypSect
. This sheet is produced on a standard-format sheet (11”x17”) provided in the FDOT CADD Software, Topic #625-000-002 FDOT Design Manual 913 - Typical Sections 913 Typical Sections 913.1, , the FDOT CADD Software contains templates for generic typical sections that can be modified to reflect, Section sheets in the plans in the following order: (1) Roadway mainline (2) Bridges for projects, #625-000-002 FDOT Design Manual 913 - Typical Sections (6) Sideroads or streets when significant work
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/2025/review/2025fdm913typsect.pdf?sfvrsn=f93b5b0a_7SPI-550-013
Standard Plans Instructions Topic No. 625-010-003 Index 550-013 Bridge Fencing On Barrier, Series Traffic Railings, certain non-FDOT standard concrete traffic railings meeting, Standard Plans Instructions Index 536-002. Evaluate the expansion joint movements of the bridge, : Standard Plans Instructions Topic No. 625-010-003 Index 550-013 Bridge Fencing On Barrier (Curved Top, Content Requirements In the Structures and/or Roadway Plans: Show and label, by name or Index number
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/spi/spi-550-013.pdf?sfvrsn=1311e118_1SPI-425-001
Standard Plans Instructions Topic No. 625-010-003 Index 425-001 Manhole Covers, Frames, Tops, with ½” seat. Standard Plans Instructions Topic No. 625-010-003 Index 425-001 Manhole Covers, Frames, , and Supplementary Inlet Details Design Criteria FDOT Design Manual (FDM) ; Drainage Manual (DM, 8 in the Plans when depths shown in the Manhole Tops details can be maintained. • Verify, the requirement for a 2-piece cover on the Drainage Structure sheets in the Plans. • 2-piece covers
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/spi/spi-425-001.pdf?sfvrsn=5192cb6e_2SPI-425-001
Standard Plans Instructions Topic No. 625-010-003 Index 425-001 Manhole Covers, Frames, Tops, with ½” seat. Standard Plans Instructions Topic No. 625-010-003 Index 425-001 Manhole Covers, Frames, , and Supplementary Inlet Details Design Criteria FDOT Design Manual (FDM) ; Drainage Manual (DM, 8 in the Plans when depths shown in the Manhole Tops details can be maintained. • Verify, the requirement for a 2-piece cover on the Drainage Structure sheets in the Plans. • 2-piece covers
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/spi/spi-425-001.pdf?sfvrsn=baea4ca2_1SPI-550-013
Standard Plans Instructions Topic No. 625-010-003 Index 550-013 Bridge Fencing On Barrier, Series Traffic Railings, certain non-FDOT standard concrete traffic railings meeting, Standard Plans Instructions Index 536-002. Evaluate the expansion joint movements of the bridge, : Standard Plans Instructions Topic No. 625-010-003 Index 550-013 Bridge Fencing On Barrier (Curved Top, Content Requirements In the Structures and/or Roadway Plans: Show and label, by name or Index number
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/spi/spi-550-013.pdf?sfvrsn=9bc9443a_10010200.impl
, Executed Form of Contract, Performance Bond and Payment Bond, Specifications, Plans (including revisions thereto issued during construction), Standard Plans, Addenda, or other information mailed, and Payment Bond. ARTICLE 1-3: The following definition is added: Standard Plans. “Standard Plans, of the United States Government FDOT Florida Department of Transportation FHWA Federal Highway, . Where the term Design Standards appears in the Contract Documents, it will be synonymous with Standard
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/july-2018/review/implemented/0010200.impl.pdf?sfvrsn=b790c387_05460100-723origind
to: Publication Yes No Office Staff Contacted Standard Plans Index Traffic Engineering Manual FDOT Design Manual Construction Project Administration Manual Basis of Estimate/Pay Items, . Construct rumble strips in accordance with the details shown in the Plans and Standard Plans, to monitor tolerances specified in Standard Plans, Index 546-010. For arterial and collector roadways, in Standard Plans Index 546-020. If measurements are outside tolerances, immediately stop grinding
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/internal/5460100-723origind.pdf?sfvrsn=768c04f7_1