5200 search results for Standard Specifications
19-08-LewisMUTCDUpdates
references to the MUTCD FDOT Standard Specifications for Road and Bridge Construction 53, Standard Specifications for Road and Bridge Construction Bulletin – 11/04/2024 ✓ 2023 Manual, Greenbook) – 03/13/2025 ✓ FY 2026-27 Standard Specifications for Road and Bridge Construction, Standard Specifications for Road and Bridge Construction 47 48 6/30/2025 25 Contact Us TRAFFIC, Rick Jenkins, P. E. State Standard Plans Engineer, Roadway Design Office Mariano Amicarelli, P
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/training/transportationsymposium/2025-june/19-08-lewismutcdupdates.pdf?sfvrsn=c6ebfdf8_12026FDM216Earthwork
the excavated areas and the embankments of a project. FDOT’s Standard Specifications Sections 110, 120, of existing pavement to prepare the area for proposed construction. See Standard Specifications, the roadway. See Standard Specifications Section 120 for additional requirements. • Regular Excavation – See Standard Specifications Section 120 for additional requirements. • Subsoil Excavation – See Standard Specifications Section 120 for additional requirements. • Excavation for Structures
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/2026/review/2026fdm216earthwork.pdf?sfvrsn=b7f7f167_8SPI-400-010
Standard Plans Instructions Topic No. 625-010-003 Index 400-010 Cantilever Retaining Wall (C-I, Bridge Design Specifications ; Structures Design Guidelines (SDG), FDOT Design Manual (FDM) Design Assumptions and Limitations Use this standard with Indexes in the 521-600 Series as appropriate. The Retaining Wall Standard Drawings consist of Standard Plans Index 400-010 and companion Data Tables located in the FDOT Structures Bar Menu as MicroStation CADD cells. These Standard Plan Indexes
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/spi/spi-400-010.pdf?sfvrsn=41084603_2SPI-400-010
Standard Plans Instructions Topic No. 625-010-003 Index 400-010 Cantilever Retaining Wall (C-I, Bridge Design Specifications; Structures Design Guidelines (SDG), FDOT Design Manual (FDM) Design Assumptions and Limitations Use this standard with Indexes in the 521-600 Series as appropriate. The Retaining Wall Standard Drawings consist of Standard Plans Index 400-010 and companion Data Tables located in the FDOT Structures Bar Menu as MicroStation CADD cells. These Standard Plan Indexes
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/spi/spi-400-010.pdf?sfvrsn=6b71ed92_3CM-620-01 Surge Protective Device at Point of Use
and understands the provisions of Sections 620 and 996 of the FDOT Standard Specifications for Road and Bridge, product literature, specifications, user manual, or similar information that shows the product meets, . FORMDROPDOWN Provide product literature, specifications, user manual, or similar information, literature, specifications, user manual, or similar information that shows the product meets, . FORMDROPDOWN Provide product literature, specifications, user manual, or similar information
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/traffic/traf_sys/compliance-matrices-2022/cm-620-01-surge-protective-device-at-point-of-use.docx?sfvrsn=505d58ae_19440200-724origind
ORIGINATION FORM Proposed Revisions to the Specifications (Please provide all information, changes to the following Publications: Publication Yes No Office Staff Contacted Standard Plans Index, the changes affect either of the following types of specifications (Hover over type to go to site.): Special Provisions Developmental Specifications List Specifications Affected: (ex. SP3270301, Specifications Office for assistance completing this form. Daniel Strickland 850-414-4130
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/internal/9440200-724origind.pdf?sfvrsn=c6f8dd2d_46800000-723origind
ORIGINATION FORM Proposed Revisions to the Specifications (Please provide all information - incomplete forms will be returned) Contact the State Specifications Office for assistance, : Will the proposed revision require changes to: Publication Yes No Office Staff Contacted Standard Plans, of the following types of specifications (Hover over type to go to site.): Special Provisions Developmental Specifications List Specifications Affected: (ex. SP3270301, Dev330TL, Dev334TL etc
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/internal/6800000-723origind.pdf?sfvrsn=795546f6_1E3Y54
ON THIS PROJECT Marine General Liability Insurance as referenced in Section 7-13.5 of the FDOT Standard Specifications may be required if any work under this Contract is performed using vessel(s)*. Prior, 6,606.000 0710- 11-101 PAINTED PAVEMENT MARKINGS, STANDARD, WHITE, SOLID, 6" GM 28.346 0710- 11-102 PAINTED PAVEMENT MARKINGS, STANDARD, WHITE, SOLID FOR INTERCHANGE AND URBAN ISLAND, 8" GM 0.031 0710- 11-123 PAINTED PAVEMENT MARKINGS, STANDARD, WHITE, SOLID FOR CROSSWALK AND ROUNDABOUT, 12
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d3/lettings/2025/jul10/e3y54.pdf?sfvrsn=f3dae183_1SP0050100PBint
Origination Form Specifications Name: Amanda Ulmer Standard Specification Section: Email, , Internal and Industry Review) What is the schedule for implementation? The Standard Specifications, affect other types of specifications? Special Provisions List Specifications Affected: SP0050100PB Other Affected Documents/Offices Contacted Yes/No Other Standard Plans No Florida Design Manual, hyperlink located on the Specifications landing page: https://www.fdot.gov/programmanagement/Specs.shtm
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2026-27/review/internal/sp0050100pbint.pdf?sfvrsn=6e9a4058_14490100int
Origination Form Specifications Name: Andrew Pinkham Standard Specification Section: 449, ? The Standard Specifications eBook and Workbook are effective July 1st every year. PRECAST CONCRETE, specifications. In addition, the delivery ticket contains Section 6 compliance verbiage. Do the changes affect other types of specifications? Neither List Specifications Affected: Other Affected Documents/Offices Contacted Yes/No Other Standard Plans No Florida Design Manual No Structures Manual
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2026-27/review/internal/4490100int.pdf?sfvrsn=cad4b865_1SP0050100PBind
Origination Form Specifications Name: Amanda Ulmer Standard Specification Section: Email, , Internal and Industry Review) What is the schedule for implementation? The Standard Specifications, affect other types of specifications? Special Provisions List Specifications Affected: SP0050100PB Other Affected Documents/Offices Contacted Yes/No Other Standard Plans No Florida Design Manual, hyperlink located on the Specifications landing page: https://www.fdot.gov/programmanagement/Specs.shtm
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2026-27/review/industry/sp0050100pbind.pdf?sfvrsn=a7d10419_14490100ind
Origination Form Specifications Name: Andrew Pinkham Standard Specification Section: 449, ? The Standard Specifications eBook and Workbook are effective July 1st every year. PRECAST CONCRETE, specifications. In addition, the delivery ticket contains Section 6 compliance verbiage. Do the changes affect other types of specifications? Neither List Specifications Affected: Other Affected Documents/Offices Contacted Yes/No Other Standard Plans No Florida Design Manual No Structures Manual
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2026-27/review/industry/4490100ind.pdf?sfvrsn=26e98099_17050000-722origind
ORIGINATION FORM Proposed Revisions to the Specifications (Please provide all information - incomplete forms will be returned) Contact the State Specifications Office for assistance, : Will the proposed revision require changes to: Publication Yes No Office Staff Contacted Standard Plans, , State Specifications Engineer SUBJECT: Proposed Specification: 7050000 Object Markers, from 993, add references to Standard Plans and Section 700 (sheeting), and renumber articles
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/internal/7050000-722origind.pdf?sfvrsn=743e261a_2SPI-455-400
Standard Plans Instructions Topic No. 625-010-003 Index 455-400 Precast Concrete Sheet Pile, ) Design Criteria AASHTO LRFD Bridge Design Specifications ; Structures Design Guidelines (SDG) Design, . If the length of piles required for a cantilevered wall exceeds the limits shown on the standard drawings, information on the Standard. Plan Content Requirements In the Structures or Roadway Plans: Standard, of Data Tables. Standard Plans Instructions Topic No. 625-010-003 Index 455-400 Precast Concrete
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/spi/spi-455-400.pdf?sfvrsn=bfa70fdb_2SPI-455-400
Standard Plans Instructions Topic No. 625-010-003 Index 455-400 Precast Concrete Sheet Pile, ) Design Criteria AASHTO LRFD Bridge Design Specifications ; Structures Design Guidelines (SDG) Design, . If the length of piles required for a cantilevered wall exceeds the limits shown on the standard drawings, information on the Standard. Plan Content Requirements In the Structures or Roadway Plans: Standard, of Data Tables. Standard Plans Instructions Topic No. 625-010-003 Index 455-400 Precast Concrete
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/spi/spi-455-400.pdf?sfvrsn=badf7690_17150100-724FHWA
Tallahassee, Florida 32312 Re: State Specifications Office Section: 715 Proposed Specification, at (850) 414-4130. Sincerely, Signature on file Daniel Strickland, P.E. State Specifications, in the Standard Plans when standard aluminum pole assemblies or standard high mast light assemblies, mast lighting, with internal vibration damping devices in accordance with Standard Plans, Index, shown in the Plans. Use pole assemblies as shown in the Standard Plans when standard aluminum pole
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/fhwa/7150100-724fhwa.pdf?sfvrsn=32953f64_17151800-722FHWA
Specifications Office Section: 715 Proposed Specification: 7151800 Highway Lighting System. Dear Mr, Strickland, P.E. State Specifications Engineer DS/dh Attachment cc: Florida Transportation Builders, arm, luminaire with lamp, and all necessary mounting hardware as indicated in the Plans and Standard, , contactors, photo electric switch, grounding, and the concrete pad as shown in the Plans and Standard, mounting hardware as indicated in the Plans and Standard Plans. 6. Pull Box: Payment will be made
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/fhwa/7151800-722fhwa.pdf?sfvrsn=accc42a2_27050000.FHWA
Re: State Specifications Office Section: 705 Proposed Specification: 7050000 Object Markers, Dan Hurtado, P.E. State Specifications Engineer DH/dt Attachment cc: Florida Transportation, or adjacent to the roadway of the types and at the locations called for in the Design Standard Plans, the alignment of the roadway as indicated in the Design Standard Plans or in the Plans. 705-2 Materials, Standard Plans and Plans. Place barrier delineators at a spacing of 25 feet for the first 100 feet
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/july-2018/review/fhwa/7050000.fhwa.pdf?sfvrsn=ddf99b68_07100401.FHWA
Re: State Specifications Office Section: 710 Proposed Specification: 7100401 Painted Pavement, . Sincerely, Signature on file Dan Hurtado, P.E. State Specifications Engineer DH/dt Attachment cc, application of standard paint and one application of Class B retroreflective pavement markers applied, of standard paint and one application of Class B retroreflective pavement markers. Additionally, with the first application of standard paint. Remove Class D markers prior to grinding, and install Class B
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2017/july-2017/review/fhwa/7100401.fhwa.pdf?sfvrsn=89b390e9_05460100-723FHWA
Specifications Office Section: 546 Proposed Specification: 5460100 Rumble Strips. Dear Mr. Nguyen: We, . The changes are proposed by David Amato from the Roadway Design Office to add the Standard Plans Indexes associated and include depth measurement on arterials and collectors in the Standard, State Specifications Engineer DS/dh Attachment cc: Florida Transportation Builders' Assoc, with the details shown in the Plans and Standard Plans, Indexes 546-001, 546-010, and 546-020. SUBARTICLE
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/fhwa/5460100-723fhwa.pdf?sfvrsn=238a0572_1