9037 search results for test
3340000.resp
3340000- SUPERPAVE ASPHALT CONCRETE RESPONSE TO COMMENTS FROM INDUSTRY REVIEW ****************************************************************************** Steven A. Sheffield steven.sheffield@dot.state.fl.us 407-264-3444 407-822-6663 Fax Comments: In section 334-5.1.1.1 Sampling and Testing requirements: Last sentence on page nine should be reviewed. “The Contractor can retain additional split samples their option.” I thought the Department was using active voice and the specs
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan09/files/3340000.resp.pdf?sfvrsn=10cea4c_0SP1200100A
scientific field testing equipment. (4) Installation and operation of equipment for dewatering. (5
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2011/files/sp1200100a.pdf?sfvrsn=e31c2ce5_03300904.impl
330 HOTMIXASPHALT–GENERALCONSTRUCTIONREQUIREMENTS. (REV1-18-12)(FA2-6-12)(7-12) SUBARTICLE330-9.4.5.2(oftheSupplemental Specifications) is deleted and the following substituted: 330-9.4.5.2 Straightedge Exceptions: Straightedge testing will not be required in the following areas: shoulders, intersections, tapers, crossovers, sidewalks, bicycle/shared use paths, parking lots and similar areas, or in the following areas when they are less than 250 feet in length: turn lanes
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul12/files/3300904.impl.pdf?sfvrsn=b86645c4_03200000.comm
Materials Testing Frequencies Do not agree with new frequencies for the properties of • Asphalt Binder
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan12/files/3200000.comm.pdf?sfvrsn=a1399e73_07130200.FHWA
of the materials in accordance with the Department’s Sampling, Testing and Reporting Guide schedule, the paving operation. Conduct field testing in accordance with FM 5-541 and FM 5-579. Remove, in accordance with the Department’s Sampling, Testing and Reporting Guide schedule. SUBARTICLE, immediately following the paving operation. Conduct field testing in accordance with FM 5-541
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan10/files/7130200.fhwa.pdf?sfvrsn=bf2f1f54_01050806comm
Plant Manager of Quality Control, Concrete Mix Designer and Testing Technicians are not needed
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul19/files/1050806comm.pdf?sfvrsn=27bf536f_27130200OrignX
Sampling, Testing and Reporting Guide schedule
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul06/files/7130200orignx.pdf?sfvrsn=cd70768e_01200100A.impl
) Soil sampling. (2) Earth work. (3) Operating scientific field testing equipment. (4
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul13/files/1200100a.impl.pdf?sfvrsn=f82e1f49_09940033FHWA
D9940033.D01 All Jobs 994 PHYSICAL REQUIREMENTS – COLOR. (REV 1-6-042-25-04) (FA 3-10-04) (1-05) SUBARTICLE 994-3.3 (Page 948) is deleted and the following substituted: 994-3.3 C o l o r : T h e r e t r o r e f l e c t i v e a n d n o n r e f l e c t i v e s h e e t i n g o r f i l m shall have the same daytime and nighttime color when viewed by reflective light regardless of type classification. The diffused color of the retroreflective sheeting, through instrumental color testing
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan05/files/9940033fhwa.pdf?sfvrsn=f91c9636_05210000SS
; therefore, assume responsibility for performance of all quality control testing and inspections required by Sections 346 and 400 for Barrier Wall construction. Perform all Quality Control Testing and inspections using CTQP qualified testing personnel. Perform compressive strength testing
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2006/files/5210000ss.pdf?sfvrsn=64184015_04551604.impl
455 REINFORCINGSTEELCONSTRUCTIONANDPLACEMENT-CROSS-HOLE SONICLOGGING(CSL) TUBES. (REV10-2-07)(FA10-17-07)(7-08) SUBARTICLE455-16.4(Page543)isdeletedandthefollowingsubstituted: 455-16.4Cross-HoleSonicLogging(CSL)Tubes:Install CSL access tubes full length in all drilled shafts from the tip of shaft to a point high enough above top of shaft to allow cross- hole-sonic-logging testing, but not less than 30 inches above the top of the drilled shaft, ground surface or water surface
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul08/files/4551604.impl.pdf?sfvrsn=d181f56c_05210000SS
responsibility for performance of all quality control testing and inspections required by Sections 346 and 400 for Barrier Wall construction. Perform all Quality Control Testing and inspections using CTQP qualified testing personnel. Perform compressive strength testing in a laboratory inspected by CCRL
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2005/files/5210000ss.pdf?sfvrsn=146f51f5_07060400.impl
706 RAISED R E T R O R E F L E C T I V E P A V E MENT MARKERS AND BITUMINOUS ADHESIVE. (REV6-20-12)(FA8-28-12)(1-13) ARTICLE706-4(Pages791-792)isdeletedandthefollowingsubstituted: 706-4Application. ApplyRPMstothebonding surface using bituminous adhesives only. The Engineer will conduct field testing in accordance with FM 5-566. Correct RPMs not applied in accordance with these requirements at no cost to the Department. Priortoapplicationofadhesive,cleantheportion of the bonding
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan13/files/7060400-impl.pdf?sfvrsn=e7c02b0_49940033SS
994 PHYSICALREQUIREMENTS–COLOR. (REV2-25-04)(FA3-10-04)(7-04) SUBARTICLE994-3.3(Page948)isdeletedandthefollowingsubstituted: 994-3.3 C o l o r : T h e r e t r o r e f l e c t i v e a n d n o n - r e f l e c t i v e s h e e t i ng or film shall have the same daytime and nighttime color when viewed by reflective light regardless of type classification. The diffused color of the retroreflective sheeting, through instrumental color testing, shall conform to the requirements of ASTM D4956
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2004/files/9940033ss.pdf?sfvrsn=528d637_0SP1200100A_Man08
. (2) Earth work. (3) Operating scientific field testing equipment. (4) Installation and operation
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2016/files/sp1200100a_man08.pdf?sfvrsn=96b8273a_06490500.comm
6490500, Steel Strain Poles, Mast Arms and Monotube Assemblies – Installation. Comments from Industry Review ****************************************************************************** Melissa Hollis 850-414-4182 melissa.hollis@dot.state.fl.us Comment: Text: The foundation is currently included in the cost of the pole assembly. Is the intent of this change to include the additional testing in the cost of the asssembly also? If so, what is the expected financial impact
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul09/files/6490500.comm.pdf?sfvrsn=2a1e2515_0NOTICE - FDOT ITSFM Web Based GPS Mapping Solution Website Update
Acceptance Testing for CEI” personnel. Need to replace the statement below with the updated
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/traffic/itsfm/documents/notice---fdot-itsfm-web-based-gps-mapping-solution-website-update.docx?sfvrsn=26df4b66_1SPM6330600-724-i19217
, will include furnishing, placement, and testing of all material, and for all tools, labor, equipment
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/maintenance/finalized/spm6330600-724-i19217.pdf?sfvrsn=3ed91d75_1SPM6330600-725-i19915
, will include furnishing, placement, and testing of all material, and for all tools, labor, equipment
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2025-26/maintenance/finalized/spm6330600-725-i19915.pdf?sfvrsn=b50bcae1_1SPM6330600-723-i18595
cable, furnished and installed, will include furnishing, placement, and testing of all material
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/maintenance/finalized/spm6330600-723-i18595.pdf?sfvrsn=f67f0b3_2