5763 search results for Standard Specifications
SPI-509-070
Standard Plans Instructions Topic No. 625-010-003 Railroad Grade Crossing Traffic Control Devices FY 2025-26 1 Index 509-070 Railroad Grade Crossing Traffic Control Devices Design Criteria FDOT Design Manual (FDM), FDOT Traffic Engineering Manual (TEM); FHWA Manual on Uniform Traffic, 509-070 , provides standard signing and pavement marking for active at-grade railroad crossing (i.e., Crossing EA See the BOE and Specifications for information on payment, pay item use, and compensation
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/spi/spi-509-070.pdf?sfvrsn=91355c3e_1SPI-700-104Series
and pavement marking. See the BOE , Specifications 700, 706, & 711 , and the Standard Plans, Standard Plans Instructions Topic No. 625-010-003 Indexes 700-104 Through 700-108 FY 2025-26 1 Indexes 700-104 through 700-108 Miscellaneous Signing and Pavement Marking Applications Design Criteria Manual on Uniform Traffic Control Devices ( MUTCD ); FDOT Traffic Engineering Manual (TEM) ; FDOT Design Manual (FDM) Design Assumptions and Limitations Indexes 700-104 through
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/spi/spi-700-104series.pdf?sfvrsn=39a3c055_1SPI-460-250
Standard Plans Instructions Topic No. 625-010-003 Index 460-250 Series Access Hatch Assembly FY 2025-26 1 Index 460-250 Series Access Hatch Assembly Design Criteria AASHTO LRFD Bridge Design Specifications; Structures Design Guidelines (SDG); Structures Detailing Manual (SDM) Design Assumptions and Limitations The Access Hatch Assembly series includes Index 460-250 for use with steel, and include a cross reference to Standard Plans Index 460-250 or 460-251 as appropriate. Payment
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/spi/spi-460-250.pdf?sfvrsn=69336e45_1InternalCommentResponse1020304
Specification Section 102 Subarticle 102-3, etc. ORIGINATION Date: 6-18-24 Name: Olivia Townsend Email: olivia.townsend@dot.state.fl.us COMMENTARY This type of operation has been traditionally handled by MSP, but use has grown over the last few years and is now better served as a Standard Specification. Establishment of a standard pay item will aid in cost tracking. INTERNAL COMMENTS AND RESPONSES BLACK = Comment BLUE = Specifications Response GREEN = Change Made
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2025-26/review/internal/comments-responses/internalcommentresponse1020304.pdf?sfvrsn=ce943149_1SPI-460-250
Standard Plans Instructions Topic No. 625-010-003 Index 460-250 Series Access Hatch Assembly FY 2026-27 1 Index 460-250 Series Access Hatch Assembly Design Criteria AASHTO LRFD Bridge Design Specifications; Structures Design Guidelines (SDG); Structures Detailing Manual (SDM) Design Assumptions and Limitations The Access Hatch Assembly series includes Index 460-250 for use with steel, and include a cross reference to Standard Plans Index 460-250 or 460-251 as appropriate. Payment
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2027/spi/spi-460-250.pdf?sfvrsn=9676451b_1SPI-102-660&661
Standard Plans Instructions Topic No. 625-010-003 Index 102-660 Sidewalk Closure & Index 102-661 Bicycle Lane Closure FY 2026-27 1 Index 102-660 Sidewalk Closure & Index 102-661 Bicycle Lane Closure Design Criteria Manual on Uniform Traffic Control Devices (MUTCD) ; FDOT Design Manual (FDM) Design Assumptions and Limitations See the Standard Plans Instructions for the 102 Series, Pedestrian and Bicycle Special Detour LS See the BOE and Specifications 102 for information
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2027/spi/spi-102-660-661.pdf?sfvrsn=facf4b9_1SPI-509-070
Standard Plans Instructions Topic No. 625-010-003 Railroad Grade Crossing Traffic Control Devices FY 2026-27 1 Index 509-070 Railroad Grade Crossing Traffic Control Devices Design Criteria FDOT Design Manual (FDM), FDOT Traffic Engineering Manual (TEM); FHWA Manual on Uniform Traffic, 509-070, provides standard signing and pavement marking for active at-grade railroad crossing (i.e., See the BOE and Specifications for information on payment, pay item use, and compensation
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2027/spi/spi-509-070.pdf?sfvrsn=562bc5b_1SPI-700-104Series
the BOE, Specifications 700, 706, & 711, and the Standard Plans Instructions for Index 706-001, Index, Standard Plans Instructions Topic No. 625-010-003 Indexes 700-104 Through 700-108 FY 2026-27 1 Indexes 700-104 through 700-108 Miscellaneous Signing and Pavement Marking Applications Design Criteria Manual on Uniform Traffic Control Devices (MUTCD); FDOT Traffic Engineering Manual (TEM); FDOT Design Manual (FDM) Design Assumptions and Limitations Indexes 700-104 through 700-108
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2027/spi/spi-700-104series.pdf?sfvrsn=73a8eb43_19950100-723impl
://www.fdot.gov/traffic/traf-sys/product- specifications.shtm Manufacturer’s Product Specifications Include product specifications showing electrical requirements, voltages, etc. Product Drawings or Cut Sheet, ://www.fdot.gov/traffic/Traf- Sys/Product-Specifications.shtm. 7.For WWVDS installed on ramps, Specifications: Equipment shall operate on solar power or with an input voltage ranging from 89, the requirements of Section 603 and the ITE Standard for Vehicle Traffic Control Signal Heads
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/implemented/9950100-723impl.pdf?sfvrsn=a31ccb0a_19710104-122resp
to implement the use of such products independent of the Standard Specifications. Implementation, : “For standard paint, durable paint, preformed thermoplastic, two reactive component material, high, Evaluation Program (NTPEP) field test data.” Should be reworded to read: “For standard paint, and standard 711 long-line thermo specs will remain under the guidance of FDOT FM-541, while all, component. The Department will test standard thermoplastic and profiled thermoplastic pavement marking
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/january-2022/review/comments-responses/9710104-122resp.pdf?sfvrsn=a731b128_4E1W36Addendum003
. Specifications, , Calculations, and Computations: ................................. 32 I. Specifications, Specifications A03_Award and Execution of Contract – Public Records (SP0030900DX) A04_Legal Requirements, : ................................. 3 3 I. Specifications, Advertisement A02_Design Build Division I Specifications A03_Award and Execution of Contract
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d1/designbuild/e1w36/e1w36addendum003.pdf?sfvrsn=be545167_1E1W36Addendum004
A15 to this RFP. Replace guardrail at both bridges. Utilize Standard Plan Index No. 536-002, Scheme, , and Computations: ................................. 3 3 I. Specifications, Advertisement A02_Design Build Division I Specifications A03_Award and Execution of Contract – Public Records, Standard Plan Index No. 536-002, Scheme III to construct the guardrail at the bridges (see Attachment, and principles. The Design-Build Firm’s standard of care shall not be altered by the application
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d1/designbuild/e1w36/e1w36addendum004.pdf?sfvrsn=4b465263_17100401-724FHWA
Tallahassee, Florida 32312 Re: State Specifications Office Section: 710 Proposed Specification, State Specifications Engineer DS/jb Attachment cc: Florida Transportation Builders' Assoc. State, (final surface) will include one application of standard paint applied to the final surface, except, marking is placed within the grinding, apply a second application of standard paint within 24 hours, one application of standard paint applied to the final surface, except as noted herein. For center
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/fhwa/7100401-724fhwa.pdf?sfvrsn=78f19347_1SP0070104-7.FHWA
: State Specifications Office Section: 007 Proposed Specification: SP0070104-7 Legal Requirements, Specifications Engineer DH/rf Attachment cc: Florida Transportation Builders' Assoc. State Construction, the Standard Protection Measures for the Eastern Indigo Snake published by the US Fish and Wildlife Service, _Standard_Prot ection_Measures.htm SP0070104-7 Use when called for by the District Environmental, . Implement the Standard Protection Measures for the Eastern Indigo Snake published by the US Fish
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/january-2018/review/fhwa/sp0070104-7.fhwa.pdf?sfvrsn=d5845cce_0SPI-521-005
, and Standard Specifications . Standard Plans Instructions Topic No. 625-010-003 Index 521-005, , and the Standard Specifications . C. Summary of Permanent Barrier Wall Table: Tabulate the individual Pay, Standard Plans Instructions Topic No. 625-010-003 Index 521-005 Concrete Barrier at Toll Sites, Specifications , 7th Edition. Design Assumptions and Limitations For general Concrete Barrier information and additional related guidance, see the Standard Plans Instructions (SPI) for Index 521-001
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/spi/spi-521-005.pdf?sfvrsn=ac36e68d_1InternalCommentResponse1200101-dj
, standard control line, compaction of embankment when no stabilized subgrade is used in between embankment, all comments and responses are verbatim as sent. The Specifications Office does not alter typos or grammar.) BLACK = Comment BLUE = Specifications Response GREEN = Change Made to Specification, is the barrier wall requirement which is in the Standard Plans. If we added something in 120, at the end of the paragraph, in case one thinks that 100% standard Proctor is the requirement
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2025-26/review/internal/comments-responses/internalcommentresponse1200101-dj.pdf?sfvrsn=470a7a50_17150100.origind
ORIGINATION FORM Proposed Revisions to the Specifications (Please provide all information ‐ incomplete forms will be returned) Contact the State Specifications Office for assistance, /Subarticles: Telephone: email: Will the proposed revision involve Design Standard Index changes? Yes, , State Specifications Engineer SUBJECT: Proposed Specification: 7150100 Highway Lighting System, to make verbiage consistent with current and future FDOT Standard Plan Indexes pending release
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/july-2018/review/internal/7150100.origind.pdf?sfvrsn=e7aaef16_0SPI-521-005
, and Standard Specifications . Standard Plans Instructions Topic No. 625-010-003 Index 521-005, , and the Standard Specifications . C. Summary of Permanent Barrier Wall Table: Tabulate the individual Pay, Standard Plans Instructions Topic No. 625-010-003 Index 521-005 Concrete Barrier at Toll Sites, Specifications , 10th Edition. Design Assumptions and Limitations For general Concrete Barrier information and additional related guidance, see the Standard Plans Instructions (SPI) for Index 521-001
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2027/spi/spi-521-005.pdf?sfvrsn=df33b583_1E1W36Addendum002
of advertisement of this contract with the exception of the Standard Specifications for Road, Revisions. The Design-Build Firm shall use the edition of the Standard Specifications for Road and Bridge, . Florida Department of Transportation Standard Specifications for Road and Bridge Construction (Divisions, Division I Specifications A03_Award and Execution of Contract – Public Records (SP0030900DX) A04_Legal, , Calculations, and Computations: ................................. 3 2 I. Specifications
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d1/designbuild/e1w36/e1w36addendum002.pdf?sfvrsn=49bae6d3_1E4X93-R0
and not the contractor s bid total. PLEASE READ STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION FY2024-25, MACHINE) (LM) 0711- 11-102 THERMOPLASTIC, STANDARD, WHITE, SOLID, 8" FOR INTERCHANGE AND URBAN ISLAND GM 3.000 0711- 11-123 THERMOPLASTIC, STANDARD, WHITE, SOLID, 12" FOR CROSSWALK AND ROUNDABOUT LF 200.000 0711- 11-124 THERMOPLASTIC, STANDARD, WHITE, SOLID, 18" FOR DIAGONALS AND CHEVRONS LF 1,000.000 0711- 11-125 THERMOPLASTIC, STANDARD, WHITE, SOLID, 24" FOR STOP LINE AND CROSSWALK LF
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d4/lettings/2025/feb07/e4x93-r0.pdf?sfvrsn=e1e56603_1