9320500-722impl

instructions, and recommended installation materials and equipment as applicable. Test Reports Submit test results and reports as required by Materials Manual, Vol 2 Section 2.4

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/implemented/9320500-722impl.pdf?sfvrsn=479ea43a_2

9310203-722impl

 931 METAL ACCESSORY MATERIALS FOR CONCRETE PAVEMENT AND CONCRETE STRUCTURES. (REV 12-8-21) (FA 12-27-21) (7-22) SUBARTICLE 931-2.3 is deleted and the following substituted: 931-2.3 Dowel Bars: Dowel bars must meet the requirements of Table 931-1. They shall be of the length, size and spacing as shown in the Plans. The Contractor shall submit to the Engineer a certified test report from, . The certified test report shall conform to the requirements of Section 6 and include metallurgical mill

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/implemented/9310203-722impl.pdf?sfvrsn=21235db8_2

9290000.comm

of these materials. For natural pozzolans, the acceptance criteria for each test method needs to be clarified. For example, replacement rates, test ages, mix design (class IV), etc. need to be clarified

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/july-2018/review/comments-responses/9290000.comm.pdf?sfvrsn=1f49cef4_0

9290000.resp

of these materials. For natural pozzolans, the acceptance criteria for each test method needs to be clarified. For example, replacement rates, test ages, mix design (class IV), etc. need to be clarified

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/july-2018/review/comments-responses/9290000.resp.pdf?sfvrsn=209c7bdf_0

D9480023

,thegasketshall bethesole element relied on to maintain a tight joint. Test pipe joints at the plant hydrostatically using test methods in ASTM D 3212 [ASTM D 3212M]. Soil tight joints must

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2002/january-2002/workbook/d9480023.pdf?sfvrsn=c82ebff0_0

9850200.comm

Comment: In Table 1.1 and 1.2 the test for Minimum Sew Strength (lbs) has been replaced with Mass per Unit Area. The criteria for the Mass per Unit Area is to simply “Provide Test Results”. However

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2017/january-2017/review/comments-responses/9850200.comm.pdf?sfvrsn=1173fd4b_0

9850200.resp

Comments: (7-22-16) General Comment: In Table 1.1 and 1.2 the test for Minimum Sew Strength (lbs) has been, Test Results”. However, there are no unit provided in the table to determine the criteria of what

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2017/january-2017/review/comments-responses/9850200.resp.pdf?sfvrsn=fa1721fb_0

6460202.impl

 646 ALUMINUMPOLES,PEDESTALS,ANDPOSTS. (REV10-14-15)(FA12-27-15)(7-16) SUBARTICLE646-2.2isdeletedandthefollowingsubstituted: 646-2.2TransformerBase: Use transformer bases listed on the Department’s Approved Product List (APL). ManufacturersseekingAPLapprovalofproprietarytransformerbasesmust submit an application in accordance with Section 6, independent laboratory test report, an ultimate moment capacity of 10,000 foot-pounds. Submit certified test reports from the manufacturer

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/july-2016/review/implemented/6460202.impl.pdf?sfvrsn=96d9d0bf_0

0060103-2.comm

, required test reports………. Suggested change: Unless defined otherwise, applications must include, . Required test reports ……… Response

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/july-2016/review/comments-responses/0060103-2.comm.pdf?sfvrsn=e1e22975_0

9900600.resp

. 3. . 990-6.1(5) “Prior to approval an impact test shall be performed by the manufacturer to verify, test.’ Response: This comment is beyond the scope of this change and will be considered for future

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/january-2016/review/comments-responses/9900600.resp.pdf?sfvrsn=3ad3149c_0

SS9620102

 962 STRUCTURALSTEELANDMISCELLANEOUSMETALITEMS (OTHER THAN A LUMINUM). (REV6-26-09)(FA7-10-09)(1-10) SUBARTICLE962-1.2(Page914)isdeletedandthefollowingsubstituted: 962-1.2 T e s t i n g : F o r s t r u c t u r a l s t e e l s u b j e c t e d t o t e n s i l e s t r e s s u s e d f o r main load- carrying members or components (as defined in Section 460), meet the ASTM A 709 impact test, (as defined in Section 460) shall meet the impact test requirements of ASTM A 709 for non-fracture

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2010/january-2010/workbook/ss9620102.pdf?sfvrsn=f6a0e94c_0

5340000.comm

: ****************************************************************************** Juan Castellanos Comment: (12-9-13) 534-6 Test Wall: Why adding, by the Engineer.A. Response: 3. 534-6: 534-6 Test Wall. If directed by the Engineer, Eerect a test wall, . The Engineer will use the erection of the test wall to determine ifverify that the Contractor’s, the positioning of the test wall, in order to satisfactorily meet all Contract requirements. Build the test wall at a permanent wall location, as directedagreed to by the Engineer. If the test wall

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/july-2014/review/comments-responses/5340000.comm.pdf?sfvrsn=2739c29b_0