4324 search results for fdot standard plans

SPI-700-013

 Standard Plans Instructions Topic No. 625-010-003 Index 700-013 Single Post Median Barrier, and designed for a wind speed of up to 110 mph when installed on existing FDOT Standard concrete traffic, are designed for temporary placement on all standard FDOT barriers, including installations, by Index 102-600 . Standard Plans Instructions Topic No. 625-010-003 Index 700-013 Single Post Median, and Traffic Signals (LRFDLTS-1) ; Structures Manual (SM) , Volume 3, FDOT Modifications to LRFDLTS-1

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2027/spi/spi-700-013.pdf?sfvrsn=b9179b41_1

2024FDM900NexGenPlans

 Topic #625-000-002 FDOT Design Manual 900 - Production of NexGen Plans 900 Production of NexGen Plans 900.1 General The requirements provided in the FDM 900 series and the FDOT CADD Manual, Manual 900 - Production of NexGen Plans 900.1.2 Symbols and Abbreviations Standard symbols, . A list of standard abbreviations is contained in the Standard Plans . Minor deviations from, than available space allows Topic #625-000-002 FDOT Design Manual 900 - Production of NexGen Plans

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/review/2024fdm900nexgenplans.pdf?sfvrsn=9f7f15c5_1

2024FDM900NexGenPlans

 Topic #625-000-002 FDOT Design Manual 900 - Production of NexGen Plans 900 Production of NexGen Plans 900.1 General The requirements provided in the FDM 900 series and the FDOT CADD Manual, #625-000-002 FDOT Design Manual 900 - Production of NexGen Plans 900.1.2 Symbols and Abbreviations, to save space. A list of standard abbreviations is contained in the Standard Plans . Minor, , 2024 2 Topic #625-000-002 FDOT Design Manual 900 - Production of NexGen Plans • Box or Three

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/2024/2024fdm900nexgenplans.pdf?sfvrsn=fd9761a4_1

2024FDM215RoadsideSafety

to the FDOT Drainage Manual Mailboxes Locate in accordance with Standard Plans, Index 110-200, Standard Plans, Index or APL drawing. January 1, 2024 50 Topic #625-000-002 FDOT Design Manual, for the development of specific criteria contained in this Chapter and the Standard Plans, feet 8 feet 8 feet 8 feet Clear zone widths for work zones are provided in Standard Plans, Index, Control Signs Single and Multi-Column Locate in accordance with Standard Plans . Overhead Sign

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/2024/2024fdm215roadsidesafety.pdf?sfvrsn=66e0f4a3_2

2025FDM215RoadsideSafety

) Refer to the FDOT Drainage Manual Mailboxes Locate in accordance with Standard Plans, Index, are provided in Standard Plans, Index 102-600. 215.2.4 Lateral Offset Lateral offset is the distance from, in accordance with Standard Plans , Index 509-100 and Index 509-070 Roadways Overpassing, by the maximum taper rates given in the Standard Plans Instructions for Index 521-001 . Modifications, ) Single-Slope Concrete Barriers (roadside applications): (a) Median – Standard Plans , Index

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/2025/review/2025fdm215roadsidesafety.pdf?sfvrsn=da6d8549_3

2025FDM215RoadsideSafety

with Standard Plans . Overhead Sign Structures (Includes DMS) Outside Clear Zone Trees Where, Crossing Traffic Control Device Locate in accordance with Standard Plans, Index 509-100 and Index, in accordance with Standard Plans, Index 110-200 Bus Benches and Transit Shelters Locate in accordance, offset blocks on wood or steel posts are detailed in Standard Plans , Index 536-001 . W-Beam, given in the Standard Plans Instructions for Index 521-001 . Modifications to Rigid Barriers

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/2025/2025fdm215roadsidesafety.pdf?sfvrsn=f3a40d5_1

2024FDM907RFPConceptPlans

 Topic #625-000-001 FDOT Design Manual 907-RFP Concept Plans 907 RFP Concept Plans 907.1, ) Architectural Plan Topic #625-000-001 FDOT Design Manual 907-RFP Concept Plans (15) Structures Plan, of completion for higher risk elements. Topic #625-000-001 FDOT Design Manual 907-RFP Concept Plans, Developmental Standard Plans (when required in RFP) Contract plans and component plans list (lead component, of wetlands Topic #625-000-001 FDOT Design Manual 907-RFP Concept Plans Table 907.3.1 RFP Concept Plans

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/review/2024fdm907rfpconceptplans.pdf?sfvrsn=ff772dd6_1

2024FDM131PlansProcessing

 Topic #625-000-002 FDOT Design Manual 131-Plans Processing 131 Plans Processing 131.1 General This chapter describes the critical activities required to process the contract plans, ) Contract Bond, (h) Standard Specifications and Plans (including revisions thereto issued during, 131.2.2.3 . Topic #625-000-002 FDOT Design Manual 131-Plans Processing 131.3 Central Office Plans, date in PSEE. For letting date changes under a new Specification Workbook and new Standard Plans

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/review/2024fdm131plansprocessing.pdf?sfvrsn=966fc248_1

653-001-IndustryReviewResponse

 Industry Review Comments and Responses FDOTStandard Plans 1 Index 653-001 Pedestrian, FDOTStandard Plans 2 Name: Bijan Behzadi Date: 8/6/25 COMMENT: Suggest adding a note to state, to 620-3.3. COMMENTS AND RESPONSES BLACK = Industry Review Comments BLUE = Standard Plans Response GREEN, – Standard Plans 3 Name: Malcom Tomatani Date: 8/16/25 COMMENT: For the Concrete Pole Mounted Signal, and regulations, including standard requirements and practices of local traffic engineering offices

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/irr/2027/653-001-industryreviewresponse.pdf?sfvrsn=5e06829a_1

SPI-700-030

 Standard Plans Instructions Topic No. 625-010-003 Index 700-030 Wind and Hanger Beams for Overhead Signs FY 2024-25 1 Index 700-030 Wind and Hanger Beams for Overhead Signs Design Criteria, (LRFDLTS) ; Structures Manual (SM) , Volume 3, FDOT Modifications to LRFDLTS; Structures Manual (SM) , Introduction, I.6 References; FDOT Design Manual (FDM) Design Assumptions, 3. FDOT Design wind Speed is by County and are based on a maximum height of 32 feet

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/spi/spi-700-030.pdf?sfvrsn=388f425b_2

SPI-700-030

 Standard Plans Instructions Topic No. 625-010-003 Index 700-030 Wind and Hanger Beams for Overhead Signs FY 2025-26 1 Index 700-030 Wind and Hanger Beams for Overhead Signs Design Criteria, (LRFDLTS) ; Structures Manual (SM) , Volume 3, FDOT Modifications to LRFDLTS; Structures Manual (SM) , Introduction, I.6 References; FDOT Design Manual (FDM) Design Assumptions, 3. FDOT Design wind Speed is by County and are based on a maximum height of 32 feet

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/spi/spi-700-030.pdf?sfvrsn=21e74acd_1

FDOTC3DDrainageWkflwsQA

, not the design parameters. Please refer to the video portion where we cover Inventor. Q: Does the FDOT State Pack include pre-created parts for typical FDOT structures? A: Yes, there is an existing parts list called FDOT Drainage that has proposed pipes and structures that are based off of Standard Detail Plans. You can also refer over to the Drainage Manual for the other parts that are used. Q

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/cadd/downloads/webinars/files/2025caddwebinarseries/fdotc3ddrainagewkflwsqa.pdf?sfvrsn=4f5c7f99_1

2018FDM130SandS

Bridge Plans,  Developmental Standard Plans, and  Plans that are prepared by an employee,  Topic #625-000-002 FDOT Design Manual 130-Signing and Sealing Documents 130 Signing and Sealing Documents 130.1 General The act of signing, dating and sealing transmitted plans, provides the Department’s requirements for signing and sealing plans and documents in conformance, professionals that are required to sign and seal plans or documents are to follow the Laws and Rules

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/2018/2018fdm130s-s.pdf?sfvrsn=476fc29_6

2025FDM130SandS

set: • Existing Bridge Plans, • Developmental Standard Plans, and • Plans that are prepared, is comprised of the following: (1) Roadway Plans January 1, 2025 2 Topic #625-000-002 FDOT Design,  Topic #625-000-002 FDOT Design Manual 130 - Signing and Sealing Documents 130 Signing, and sealing. This chapter provides the Department’s requirements for signing and sealing plans, . Other licensed professionals that are required to sign and seal plans or documents are to follow

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/2025/2025fdm130sands.pdf?sfvrsn=8305b933_2

SPI-425-055

 Standard Plans Instructions Topic No. 625-010-003 Index 425-055 Ditch Bottom Inlet Type K FY 2024-25 1 Index 425-055 Ditch Bottom Inlet Type K Design Criteria FDOT Design Manual (FDM) ; Drainage Manual (DM) ; Drainage Design Guide (DDG) Design Assumptions and Limitations This inlet, structure bottoms. Plan Content Requirements Include Drainage Structure information in the Plans, length (L) in Plans. Payment Item number Item Description Unit Measure 425-161- Inlets, Ditch

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/spi/spi-425-055.pdf?sfvrsn=a215b34f_2

SPI-425-060

 Standard Plans Instructions Topic No. 625-010-003 Index 425-060 Back of Sidewalk Drainage FY 2024-25 1 Index 425-060 Back of Sidewalk Drainage Design Criteria FDOT Design Manual (FDM) ; Drainage Manual (DM) ; Drainage Design Guide (DDG) Design Assumptions and Limitations Maximum Pipe, (minimum). Plan Content Requirements Include Drainage Structure information in the Plans in accordance, (Yard Drain, Concrete Endwall, etc.) in the Plans. Payment Item number Item Description Unit

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/spi/spi-425-060.pdf?sfvrsn=f2785396_2

SPI-524-001

 Standard Plans Instructions Topic No. 625-010-003 Index 524-001 Ditch Pavement and Sodding FY 2024-25 1 Index 524-001 Ditch Pavement and Sodding Design Criteria FDOT Design Manual (FDM) ; Drainage Manual (DM); Drainage Design Guide (DDG) Design Assumptions and Limitations See General, Riprap (Ditch Lining TN TN Moderate-High Plan Content Requirements Include Ditch Pavement in the Plans, of ditch pavement. If weep hole spacing needs to be reduced to 5’ minimum, detail in Plans. Payment

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/spi/spi-524-001.pdf?sfvrsn=313e9192_2

SPI-425-055

 Standard Plans Instructions Topic No. 625-010-003 Index 425-055 Ditch Bottom Inlet Type K FY 2025-26 1 Index 425-055 Ditch Bottom Inlet Type K Design Criteria FDOT Design Manual (FDM) ; Drainage Manual (DM) ; Drainage Design Guide (DDG) Design Assumptions and Limitations This inlet, structure bottoms. Plan Content Requirements Include Drainage Structure information in the Plans, length (L) in Plans. Payment Item number Item Description Unit Measure 425-161- Inlets, Ditch

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/spi/spi-425-055.pdf?sfvrsn=cffd9e85_1

SPI-425-060

 Standard Plans Instructions Topic No. 625-010-003 Index 425-060 Back of Sidewalk Drainage FY 2025-26 1 Index 425-060 Back of Sidewalk Drainage Design Criteria FDOT Design Manual (FDM) ; Drainage Manual (DM) ; Drainage Design Guide (DDG) Design Assumptions and Limitations Maximum Pipe, (minimum). Plan Content Requirements Include Drainage Structure information in the Plans in accordance, (Yard Drain, Concrete Endwall, etc.) in the Plans. Payment Item number Item Description Unit

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/spi/spi-425-060.pdf?sfvrsn=e856d986_1

SPI-524-001

 Standard Plans Instructions Topic No. 625-010-003 Index 524-001 Ditch Pavement and Sodding FY 2025-26 1 Index 524-001 Ditch Pavement and Sodding Design Criteria FDOT Design Manual (FDM); Drainage Manual (DM); Drainage Design Guide (DDG) Design Assumptions and Limitations See General, Lining TN TN Moderate-High Plan Content Requirements Include Ditch Pavement in the Plans, . If weep hole spacing needs to be reduced to 5’ minimum, detail in Plans. Payment Item number Item

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/spi/spi-524-001.pdf?sfvrsn=130c93fa_2
20 of 4324 results