9038 search results for f

4610000SS

using a heat cured, high temperature epoxy capable of withstanding temperatures of -40 o F to 250 o F [-40 o C to 121 o C] 461-3 Design. Design all bearings to be replaceable without

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2006/january-2006/workbook/4610000ss.pdf?sfvrsn=6e4d8643_0

1050101.impl

r i b e c a l i b r a t i o n f r e q u e n c i e s , maintenance schedule and procedures, and feature intersected. Detailed d e scriptions o f e a c h b r i d g e c o n s t r u c t i o n

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/july-2016/review/implemented/1050101.impl.pdf?sfvrsn=b359373_0

9920000.impl

Height Aspermanufacturer’s recommendation Setback 12 f e e t T i l t 0 ° O p t i mization Criteria, range of minus40°F to plus 190°F. Hardness of the molded rubber shall be 65 durometer. 992-2.8.2, of the mated connectors shall not exceed a temperature rise of 54°F referenced to 73°F ambient, temperature rise of the mated connectors and the cable shall not be greater than 54°F referenced to 73°F, Lighting. 992-5.1 L u m i n a i r e s : U n d e r d e c k f i x t u r e s s h a l l b e w a l l

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/july-2016/review/implemented/9920000.impl.pdf?sfvrsn=70edb14e_0

0083700SP

t o f members pre-selected by the Engineer and the President of the Florida Transportation Builders, : T h e C o n t r a c t o r s h a l l f u r n i s h t o e a c h B o a r d member a set of all

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2006/january-2006/workbook/0083700sp.pdf?sfvrsn=d6402d05_0

0090503.impl

specifications. 3. T h e t o t a l q u a n t i t y f o r w h i c h p a r t i a l p a y ment is made shall, in the Contract. 5. D e l i v e r y c h a r g e s f o r materials delivered to the jobsite will be included

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/july-2016/review/implemented/0090503.impl.pdf?sfvrsn=93926379_0

1090000SP

to maintain an ambient air temperature of 70 ± 5°F [20 ± 3°C]. (c) Desks (with drawers and locks) 1 3 5 8 10 (d) Office chairs 1 3 5 8 10 (e) Stackable chairs 4 8 10 12 16 (f) Fire Resistant Cabinet: fire

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2006/january-2006/workbook/1090000sp.pdf?sfvrsn=f17f90b5_0

7450000SP

equipment, materials, and labor necessary for a complete and accepted installation. 745-5.3 F u r n i s, s t a l l : T h e C o n t r a c t u n i t p r i c e p e r a s s e m b l y f o r I n d u c t i v e L

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2006/january-2006/workbook/7450000sp.pdf?sfvrsn=c60294ee_0

SP7450000

installation. 745-5.3 F u r n i s h : T h e C o n t r a c t u n i t p r i c e p e r a s s e mbly, b l y f o r I n d u c t i v e L o o p A s s e mbly, installed, will include all materials and labor

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2007/january-2007/workbook/sp7450000.pdf?sfvrsn=fba546fc_0

3300000.origind

TO: SpecificationReviewDistributionList FROM: DanielScheer,P.E.,StateSpecificationsEngineer SUBJECT:Proposed S p e c i f i c, Binder Type Minimum Temperature (°F) ≤ 1 inch 50 Any mixture > 1 inch containing a PG asphalt binder

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/january-2016/review/internal/3300000.origind.pdf?sfvrsn=3708aae9_0

6460000.origind

TO: SpecificationReviewDistributionList FROM: DanielScheer,P.E.,StateSpecificationsEngineer SUBJECT:Proposed S p e c i f i c, certification letter for product approval. 7. I d e n t i f i c a t i o n : I s l e g i b l y a n d v i s i b l

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/january-2016/review/internal/6460000.origind.pdf?sfvrsn=260be6f_0

0071201FGT.origind

TO: SpecificationReviewDistributionList FROM: DanielScheer,P.E.,StateSpecificationsEngineer SUBJECT:Proposed S p e c i f i c a t i o n : S P 0 0 7 1 1 0 5 F G T L e g a l R e q u i r e m e n t s a n d R e s p o n s i b i l i

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/january-2016/review/internal/0071201fgt.origind.pdf?sfvrsn=67cfa129_0

9380000.origind

TO: SpecificationReviewDistributionList FROM: DanielScheer,P.E.,StateSpecificationsEngineer SUBJECT:Proposed S p e c i f i c, methods conducted at normal laboratory temperature (65°F-7890°F) and conditions. Conduct all grout

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/january-2016/review/internal/9380000.origind.pdf?sfvrsn=740b216c_0

9230000.origind

TO: SpecificationReviewDistributionList FROM: DanielScheer,P.E.,StateSpecificationsEngineer SUBJECT:Proposed S p e c i f i c a t i o n : 9 2 3 0 0 0 0 W a t e r f or Concrete. Inaccordance with Specification Development

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/january-2016/review/internal/9230000.origind.pdf?sfvrsn=35baf66_0

5560200.origind

TO: SpecificationReviewDistributionList FROM: DanielScheer,P.E.,StateSpecificationsEngineer SUBJECT:Proposed S p e c i f i c, with no bell modification (f)6. No elliptical reinforcing steel is allowed (g)7. Single cage

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/january-2016/review/internal/5560200.origind.pdf?sfvrsn=5290f40e_0

SP0080307SDRB

i s t o f members pre-selected by the Engineer and the President of the Florida Transportation, t y : T h e C o n t r a c t o r s h a l l f u r n i s h t o e a c h B o a r d member a set of all

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2007/january-2007/workbook/sp0080307sdrb7b716ef725e946998e85ae2adaba18e6.pdf?sfvrsn=eb329c48_0

3000000.FHWA

at 414-4130. Sincerely, S i g n a t u r e o n f i l e D a n i e l S c h e er, P . E . State S p e c i f i c a t i o n s E n g i n e e r D S / o t A t t a c h ment cc: FloridaTransportationBuilders, for volumetric change: 1 + 60) - (T K V = V 1 Where: 3000000.D01 All Jobs V= V o l ume o f t h e b i t, =Correctionfactor(Coefficient of Expansion). T= T e mperature ( i n º F ) , o f t h e b i t u m i n o u s, l u me o f b i t u minous material at 60ºF (pay volume). 3000000.D01 All Jobs V1

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/january-2016/review/fhwa/3000000.fhwa.pdf?sfvrsn=79e920e1_0

3340802.impl

b l o t ) n = n u mber o f t e s t s ( s u b l o t s ) s = s a mple s t a n d a r d d e v i a t i, ) will be 100. (7) I f Q U o r Q L i s a n e g a t i v e n u mber, then calculate the percent within

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/january-2016/review/implemented/3340802.impl.pdf?sfvrsn=b85506fb_0

SS0060000

Certification: 6-1.3.1 P r o d u c e r C e r t i f i c a t i o n : P r o v i d e c o mplete, by a legally responsible person from the producer and notarized. 6-1.3.1.1 Q u a l i f i e d P r o d u c t s L i s t : T h e P r o d u c t E v a l u a t i o n S e c t i o n i n t h e S t a t e S p e c i f i c, s u c c e s s f u l l y c o mpleting the Department’s evaluation are eligible for inclusion, , c.LaboratoryIdentificationandName, d. T r a i n i n g I d e n t i f i c a t i o n N u mbers (TIN

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2008/january-2008/workbook/ss006000032b8ea40f0b44fe5b995174f2f2b5cab.pdf?sfvrsn=dec3ffe5_0

SS0060000

Certification: 6-1.3.1 P r o d u c e r C e r t i f i c a t i o n : P r o v i d e c o mplete, by a legally responsible person from the producer and notarized. 6-1.3.1.1 Q u a l i f i e d P r o d u c t s L i s t : T h e P r o d u c t E v a l u a t i o n S e c t i o n i n t h e S t a t e S p e c i f i c, s u c c e s s f u l l y c o mpleting the Department’s evaluation are eligible for inclusion, , c.LaboratoryIdentificationandName, d. T r a i n i n g I d e n t i f i c a t i o n N u mbers (TIN

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2008/january-2008/workbook/ss0060000.pdf?sfvrsn=358ac3da_0
20 of 9038 results