9199 search results for test
6300000.FHWArevised
or a similar sealant suitable for the application and approved by the Engineer. Perform continuity tests and insulation resistance tests on all locate wires. Provide the Engineer with all test results, and insulation resistance tests on all locate wires. Provide the Engineer with all test results. Replace, in the plans and Design Standards. 630-2 Materials. Use materials that have been tested and listed, , installing, and testing the locate wire is included in the cost of the conduit. Furnishing and installing
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan13/files/6300000.fhwarevised.pdf?sfvrsn=9474ae9e_01450302.FHWA
material, as determined by FM 1-T 267 and by averaging the test results for three randomly selected, the stratum or stockpile unsuitable for construction of the reinforced fill volume if an individual test, approved by the Engineer. Submit a copy of certified test results and a certificate of compliance, prior to delivering the backfill to the site. Use a Department-approved testing laboratory for all testing. Submit an alternate design, prepared in accordance with 145-2, when backfill meeting
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan13/files/1450302-fhwa.pdf?sfvrsn=285f69cc_4informational-guide-design-of-traffic-signal-detection-technologies_september-2022
and the shielded lead-in cable. 5.1.4.2 Calibration and Testing • Each loop is required to be tested for conformance to FDOT requirements. Tests include: o Measuring the series resistance along the loop, the resistance of the insulation, using an insulation tester (“megger”). If the insulation is less than
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/traffic/cmtp/stamp/informational-guide-design-of-traffic-signal-detection-technologies_september-2022.pdf?sfvrsn=52d7d577_1BMRM Chapter 5
of field testing is that no cores are taken, i.e., the test is performed on the concrete surface, be obtained and lab tested if more accurate values are needed. Chloride Profile This test determines, Testing, Flow Test .......................................................... 5-16 Figure 5.2 Concrete, Tests: Hammer (left) and Chain Drag (right) .......................................... 5-28 Figure
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/maintenance/maintenance/str/bi/reference-manual/bmrm-chapter-5.pdf?sfvrsn=7f21f2f_0Chapter 5: Concrete Basics
of field testing is that no cores are taken, i.e., the test is performed on the concrete surface, be obtained and lab tested if more accurate values are needed. Chloride Profile This test determines, Testing, Flow Test .......................................................... 5-16 Figure 5.2 Concrete, Tests: Hammer (left) and Chain Drag (right) .......................................... 5-28 Figure
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/maintenance/str/bi/reference-manual/chapter-5-concrete-basics.pdf?sfvrsn=13f9d595_09310101.FHWA
of reinforcing steel shall be based on test samples taken randomly by the Department and manufacturer’s certified mill analysis of test results meeting the specification limits of the ASTM or AASHTO designation for the particular size, grade and any additional requirements. Randomly taken test samples and certification of test values, representing each production LOT of reinforcing steel, shall be provided to the Engineer for each Contract prior to use. Randomly taken test samples shall be cut from
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan11/files/9310101.fhwa.pdf?sfvrsn=a6d9f0ab_09710302.comm
karen.byram@dot.state.fl.us Comments: (12-2-11) A 5 year test deck seems impractical. Additionally, test. To avoid confusion, the 3year test deck performance requirement can be clearly identified as different from the 'service life' to avoid confusion. A 3 year test deck is much more manageable, and at traffic volumes at the QPL Test deck requirement I would think that the extension to 5 years, and yellow thermoplastic test deck sections were not installed correctly in accordance
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul12/files/9710302.comm.pdf?sfvrsn=b402feb2_04550501-122resp
) 942-1405 aprasad@ftba.com Comments: (5-25-21, Internal) 455-5.1 In the setting of permanent and test, piles in the same manner and to the same depth test piles were predrilled, unless required otherwise, depth as the test piles. This would provide relationship of driving data to the test pile, predrill depth of the test piles. We agreed with this request because the driving criteria is based on the test piles conditions. In order not to alter the driving criteria the predrilling should
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/january-2022/review/comments-responses/4550501-122resp.pdf?sfvrsn=c94af689_29140000.FHWA
), qualifying tests shall be performed. Test methods for these substances shall be those mandated by EPA, of gradation analysis) in lieu of FM 1-T267 after mixing. The maximum allowable test result is 4.7, of gradation analysis) in lieu of FM 1-T267 after mixing. The maximum allowable test result is 4.7
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/july-2014/review/fhwa/9140000.fhwa.pdf?sfvrsn=30760c59_0DEV705-993LBD (10-22-20)
. The yellowness index shall not exceed 12 when tested in accordance with ASTM E313. The daytime 45 degrees, 0 degrees luminance factor, Cap Y, shall be a minimum of 70, tested in accordance with ASTM E1347, with no delaminating. No post shall split, crack, break, or separate from base. Posts shall be tested and evaluated according to the National Testing Product Evaluation Program (NTPEP) Evaluation of Temporary, with a minimum of 10 impacts (default testing procedure uses a maximum of 200 impacts). 993-2.2.4.2 Ground
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/special-case/developmental/dev705-993lbd-(10-22-20).pdf?sfvrsn=4d37556a_14500204FHWA
of the shipping strength test, before 28 days, is permitted by testing compressive strength cylinders that are cured under the conditions similar to the product or by testing temperature match cured, , or any other nondestructive test method acceptable to Engineer, is permitted to estimate the strength before its verification by test cylinders. The shipping strength test is the average compressive strength of two test cylinders. Do not ship products until accepted and stamped by the QC
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2025-26/review/fhwa/4500204fhwa.pdf?sfvrsn=e89a140f_16820000.FHWA
all tests. 682-1.4.2 Field Test Requirements: Perform local field operational tests at each, in the video display system test the testing of each color video monitor type, each secondary, the right to witness all tests. 682-1.4.2 Field Test Requirements: Perform local field operational tests, and after being subjected to the environmental testing procedures described in NEMA TS2, Sections 2.2.7, lower half with a clear, rain repellant product prior to final acceptance. 682-1.4 Testing
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/january-2018/review/fhwa/6820000.fhwa.pdf?sfvrsn=2dfc2250_06820000.FHWA2
under test. The Engineer reserves the right to witness all tests. 682-1.4.2 Field Test Requirements, basis. 682-2.5 Testing: 682-2.5.1 General: Submit a detailed system acceptance test plan, acceptance. 682-1.4 Testing: 682-1.4.1 General: Perform a field acceptance test (FAT) on equipment, . The Engineer reserves the right to witness all tests. 682-1.4.2 Field Test Requirements, must performs all required functions during and after being subjected to the environmental testing
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/january-2018/review/fhwa/6820000.fhwa2.pdf?sfvrsn=985d988b_05270000.FHWA
to reflect new standards for testing for detectable warnings on walking surfaces. Please review, : Provide Detectable Warnings that meet the following minimum material property requirements when tested, and include certified test reports from an independent lab showing the product meets, Applications that include certified test reports from an independent laboratory that shows, the following minimum material property requirements when tested in accordance with the indicated
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul11/files/5270000.fhwa.pdf?sfvrsn=74e74fa9_09380402.comm
or ts ,- - - - Mi ke Mi cha elBer gi n, PE Sta teStr uctura l Ma teri a l sEngi neer Sta teMa
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2015/january-2015/review/comments-responses/9380402.comm.pdf?sfvrsn=f57c4103_09380402.resp
or ts ,- - - - Mi ke Mi cha elBer gi n, PE Sta teStr uctura l Ma teri a l sEngi neer Sta teMa
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2015/january-2015/review/comments-responses/9380402.resp.pdf?sfvrsn=3d22a3a1_09320103.origind
if required by the manufacturer. When a manufacturer’s product is tested and approved, substituted: 932-1.3.2 P h y s i c a l R e quirements: Silicone Sealant Type Test Method TypeA TypeB, , 20 ml/min 20 ml/min 20ml/min 20ml/min 9320103 All Jobs Silicone Sealant Type Test Method TypeA, % minimum 1400% minimum 9320103 All Jobs Silicone Sealant Type Test Method TypeA TypeB, of sealant, briquettes shall be tested in accordance with AASHTO T132
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/july-2014/review/internal/9320103.origind.pdf?sfvrsn=ad062c96_06330201-723impl
, and are tested according to the Telcordia/Bellcore GR-326-CORE standard. When tested according to the TIA and EIA’s Fiber Optic Test Procedure (FOTP)- 171 (TIA/EIA-455-171B) at the manufacturer, ensure, and a maximum loss of less than or equal to 0.50 decibel for field-installed temporary connectors. Test, identification on all test results or fiber related documents submitted to the Engineer. Install cable tags
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/implemented/6330201-723impl.pdf?sfvrsn=41f536b7_16330201-723origind
are compliant with the TIA/EIA-604 standards, as applicable, and are tested according to the Telcordia/Bellcore GR-326-CORE standard. When tested according to the TIA and EIA’s Fiber Optic Test, for field-installed temporary connectors. Test the connectors as detailed in FOTP-107 (TIA -455-107A, for the identification of fiber optic cable. Provide cable tag identification on all test results or fiber related
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/internal/6330201-723origind.pdf?sfvrsn=d369b6db_17090201.FHWA
in accordance with the Department’s Sampling, Testing and Reporting Guide schedule. SUBARTICLE, . TheDepartment reserves the right to test the markings within 3 days of receipt of the Contractor’s certification. Failure to afford the Department opportunity to 7090201 All Jobs test the markings will result in non-payment. The test readings should be representative of the Contractor’s striping, with the Department’s Sampling, Testing and Reporting Guide schedule. SUBARTICLE 709-4.1 (pages 793 - 794
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan10/files/7090201.fhwa.pdf?sfvrsn=c34e0ed6_0