9037 search results for test

1630000.origind

in the contract documents. 163-4 Acceptance Testing. Prior to placement, provide to the Engineer, . Provide certification of testing as required in 987-2.4.from a soil testing laboratory approved, ) test per specifications in FM 1-T267. Prior to installation of plants, perform a field percolation test that consists of the following: d 1. Dig or drill a hole at least 6 inches in diameter, in all holesat eacha test site, then notify the engineer of the a failed test. 163-3 Method

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2017/july-2017/review/internal/1630000.origind.pdf?sfvrsn=65e4e284_0

D0050085.do

testing and material sampling activities. Make copies of the completed forms available, . Ensure that the QC test data is entered into the Department’s database on a daily basis

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2003/january-2003/workbook/d0050085.do.pdf?sfvrsn=6bd5f867_0

5440000.impl

listed on the APL. Manufacturers seeking approval must submit and meet all crash testing requirements, submitted to and received by FHWA after January 1, 2011 must meet the crash test requirements

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/july-2016/review/implemented/5440000.impl.pdf?sfvrsn=6a8798dd_0

4550103DB.comm2

): The specification needs to define ‘reputable testing laboratory’. I suggest replacing ‘reputable, splices, what is going to require them to allow us to test? Doesn’t the text in red above deal just

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/july-2016/review/comments-responses/4550103db.comm2.pdf?sfvrsn=1d1754ad_0

4550103.comm2

to define ‘reputable testing laboratory’. I suggest replacing ‘reputable’ with a definition, to allow us to test? Doesn’t the text in red above deal just with unexpected pile extensions

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/july-2016/review/comments-responses/4550103.comm2.pdf?sfvrsn=731a65ed_0

1050404MM84V2-723comm

design approval process. Additionally, the test methods listed are not specific to the mix design, as applicable. For these reasons, I recommend the title of Table I be changed to ‘ SCC Testing

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/comments-responses/1050404mm84v2-723comm.pdf?sfvrsn=725cb4c8_1

1050404MM84V2-723resp

document and the mix design approval process. Additionally, the test methods listed are not specific, to ‘ SCC Testing Requirements’. Remove the Minimum Target Slump Flow Value: In Table I, the main

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/comments-responses/1050404mm84v2-723resp.pdf?sfvrsn=e4b6e98a_1

Spec and Plan form 700-020-02

and Quality Control sampling and testing results are in substantial compliance with the contract, the input of test results into the Department’s MAC database within 24 hours of results being received

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/designsupport/districts/d4lap/projectmanagementanddistrictresources/construction/spec-and-plan-form-700-020-02.pdf?sfvrsn=a118d6c9_1

TERL Product Certification Handbook

Process PCH-06 APL Quality Management System Requirements PCH-07 Testing Laboratory and Test Reporting

https://www.fdot.gov/traffic/traf-sys/terl-pch.shtm

Home

multiple pilot programs across Florida, and our partners are developing, testing, and implementing, organizations to test and develop cutting-edge technologies. Whether we are serving on multi-state

https://www.fdot.gov/traffic/its/home

1020200.resp

stands would sit? What material would that be, something to match the test set up? RESPONSE: It means, sign substrate are being added as I write this . This is from WZ-85 1. The crash-tested signs, that any portable sign stand or other device successfully crash tested with one brand, laminates called Reynalite, Alpolic, and DiBond have been crash tested on certain portable sign, sign stand or other device successfully crash tested with one brand will be acceptable when used

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan09/files/1020200.resp.pdf?sfvrsn=359e6d6f_0

4070000.D01.FHWA

quality control testing and inspections in accordance with Sections 346. Prepare,cure,andtest the test cylinders in accordance with ASTM C 31 and ASTM C 39 test methods. The use of 4 x 8 inch test cylinders is allowed for the testing of precast culverts, provided that it meets the requirements, . The use of 4 x 8 inch test cylinders is allowed for the testing of precast culverts, provided that it, . 407-4 Materials Acceptance and Testing. 407-4.1 General: Meet concrete materials, testing, inspection

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul08/files/4070000.d01.fhwa.pdf?sfvrsn=4a60bf66_0

4070000.d01.fhwa

quality control testing and inspections in accordance with Sections 346. Prepare,cure,andtest the test cylinders in accordance with ASTM C 31 and ASTM C 39 test methods. The use of 4 x 8 inch test cylinders is allowed for the testing of precast culverts, provided that it meets the requirements, . The use of 4 x 8 inch test cylinders is allowed for the testing of precast culverts, provided that it, . 407-4 Materials Acceptance and Testing. 407-4.1 General: Meet concrete materials, testing, inspection

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul08/files/4070000.d01.fhwa6d5728e0bb59401fa4fbb31319cd32f7.pdf?sfvrsn=27c1a05_0

7820000.origind

for the device or system under test. The Engineer reserves the right to witness all tests. 782-1.4.2 Field Test Requirements: Perform local field operational tests at CCTV field sites according, basis. 782-2.5 Testing: 782-2.5.1 General: Submit a detailed system acceptance test plan, to the environmental testing procedures described inan ambient operating temperature range of minus 30°F to 165º F, completed environmental testing as defined in the environmental requirements section of the NEMA TS 2

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul13/files/7820000.origind.pdf?sfvrsn=f514b4a0_0

7820000.FHWA

specified for the device or system under test. The Engineer reserves the right to witness all tests. 782-1.4.2 Field Test Requirements: Perform local field operational tests at CCTV field sites, in the video display system test the testing of each color video monitor type, each secondary, being subjected to the environmental testing procedures described inan ambient operating, its device has successfully completed environmental testing as defined in the environmental

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul13/files/7820000.fhwa.pdf?sfvrsn=b4696cc1_0

1050806impl

, compressive strength testing, and the recording/reporting of all test data. 105-8.7 Structural Concrete, , for personnel performing concrete plastic property tests and ACI Self-Consolidating Concrete Testing, property testing on concrete for materials acceptance are qualified CTQP Concrete Field Technicians Level 1. Plastic property testing will include but not be limited to slump, temperature, air content, will include initial sampling and testing to confirm specification compliance prior to beginning

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul19/files/1050806impl.pdf?sfvrsn=1c2148f7_2

SP6850000

. 685-4 Testing. Provide a field acceptance test plan to the Engineer for approval at least 14 days prior to commencement of testing. After approval of the acceptance test plan, perform testing, subjected SP6850000 685 Items to the environmental testing procedures described in NEMA TS 2, the test. 685-6 Warranty. Ensure the UPS includes a manufacturer’s warranty covering defects, and installed, will include furnishing, placement, and testing of all equipment and materials

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/janworkbook2015/files/sp6850000.pdf?sfvrsn=ae88a7e6_4

6850000.impl

, parts layout and parts lists. 685-4 Testing. Provide a field acceptance test plan to the Engineer for approval at least 14 days prior to commencement of testing. After approval of the acceptance test plan, perform testing of the installed UPS equipment. Furnish all equipment, software, and supplies necessary for conducting the test. 685-6 Warranty. Ensure the UPS includes a manufacturer’s, with specified wattage and operate properly during and after being subjected to the environmental testing

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2015/january-2015/review/implemented/6850000.impl.pdf?sfvrsn=b2d0effa_0

6630000-722origind

Testing: Subject the system to field acceptance tests (FATs). Develop and submit a test plan, and vehicle detection. Detector cards must include a test switch that can be used to manually generate, during and after being subjected to the environmental testing procedures described in NEMA TS 2, , will include furnishing, placement, and testing of all equipment and materials, and for all tools, labor

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/internal/6630000-722origind.pdf?sfvrsn=385319e1_2

6630000.origind

. Ensure that status indicators remain unobstructed and visible. 663-3.1 Field Testing: Subject the system to field acceptance tests (FATs). Develop and submit a test plan for FATs to the Engineer, include indicators for power and vehicle detection. Detector cards must include a test switch, testing procedures described in NEMA TS2, Sections 2.2.7, 2.2.8, and 2.2.9. Detectors and detector, and preemption system, furnished and installed, will include furnishing, placement, and testing

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/july-2014/review/internal/6630000.origind.pdf?sfvrsn=da3a7316_0
20 of 9037 results