9199 search results for test
SS7090201
with the Department’s Sampling, Testing and Reporting Guide schedule. SUBARTICLE 709-4.1 (Pages 793 and 794, FM-5-541. TheDepartment reserves the right to test the markings within 3 days of receipt of the Contractor’s certification. Failure to afford the Department opportunity to test the markings will result in non-payment. The test readings should be representative of the Contractor’s striping performance
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2010/january-2010/workbook/ss7090201.pdf?sfvrsn=3f296c26_04600000.D03FHWA
, and perform all nondestructive testing for structural steel or miscellaneous metal structures, Testing and Certifications ....................Section 962 Galvanizing, , clearly addressing the methods used, frequency of inspections or tests, and personnel responsible, g.Installationofhighstrengthboltsandrotationalcapacity(RC) tests; and Direct Tension Indicator (DTI) Verification tests h. F i e l d w e l d i n g ; i . B l a s t c l e a n i n g , p a i n t i n g , g a l v a n
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan07/files/4600000.d03fhwa.pdf?sfvrsn=43fa1e5e_09710800Origin
tested in accordance with ASTM D 638. 971-108.9 Plastic Pull test: The stripes and markings shall, : Component Test M e t h o d White Yellow Binder 2 0 . 0 % minimum 20.0% minimum TiO 2 , Type II, be prepared in accordance with ASTM D 4960 and shall meet the following criteria: Property Test M, : Component Test M e t h o d White Yellow Binder 2 0 . 0 % minimum 20.0% minimum TiO 2 , Type II, the following criteria: Property Test M e t h o d M i n i mum Maximum Water Absorption ASTMD570 - 0.5
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul06/files/9710800origin.pdf?sfvrsn=e5b6afbb_03340203.resp2
time dealing with paperwork instead of testing. DAB typically performs 1 to 2 QC tests and an additional 2 to 3 PC tests per day, that's a substantial increase in reporting. I cannot put into words, data comparison they put together for the IV-QC test failures. It will open up a can a worms, . The contractors need to be able to perform any test he deems fit at any time without someone looking over his shoulder. I believe that contractors will reduce their testing just to reduce the amount
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul10/files/3340203.resp2.pdf?sfvrsn=f1b3ae1e_05340000.impl
of all quality control testing and inspections required by Sections 346 and 400 for the precast component construction. Perform all Quality Control Testing using CTQP qualified testing personnel. Perform compressive strength testing in a laboratory inspected by CCRL or CMEC, with all, certified test reports, and written certification that the product meets the requirements, . L.Providetheconcretewall(PrecastorCast-in-Place)withauniform color, pattern, and texture. 534-8 Test Wall
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/programmanagement/implemented/workbooks/history/jul09/files/5340000.impl.pdf?sfvrsn=4f937962_05340000ORGIN
acceptance; therefore, assume responsibility for performance of all quality control testing, Control Testing using CTQP qualified testing personnel. Perform compressive strength testing, . ManufacturersseekingevaluationofproductsforinclusionontheQPLmustsubmit an application in accordance with Section 6, independently certified test reports, , pattern, and texture. 534-8 Test Wall. Erectatestwallsectionnotlessthan50feet[15.0m] in length before, of the test wall to determine if the Contractor’s methods and equipment are sufficient to produce a sound
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul06/files/5340000orgin.pdf?sfvrsn=fb4530d7_09310201.origind
Materials Office/352-955-6620 Problem statement: 1. This article requires a certified test report, . This is confusing. 2. The term “certified test report” should be “certified mill analysis” to align with STRG requirements. 3. Acceptance is based on the certified test report. Acceptance should be based on SMO’s review of the certified mill analysis. 931-2 currently requires a certified test report, in the certified test report. This material is not QPL and is accepted by certification. The term certified test
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul09/files/9310201.origind.pdf?sfvrsn=cce43b06_04100000Origin
not be shipped to the project. Reduce the frequency of absorption tests to one test every five LOTs, for connection to endwalls or cast-in- place sections. 410-3 Materials Acceptance and Testing of Precast, : Prepare, cure, and test the test cylinders in accordance with ASTM C 31 [ASTM C 31M] and ASTM C 39 [ASTM C 39M] test methods. The use of 4 x 8 inch [100 x 200 mm] test cylinders is allowed for the testing of precast concrete box culverts, provided that it meets the requirements of 450-4.1. Follow
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan07/files/4100000origin.pdf?sfvrsn=25b40fcb_01050000.resp
, testing and inspection for both field and laboratory tests. Include employed and subcontracted, . (3)- Article 105-6 Delete the last sentence of this Article, , which reads: " Ensure the testing, Engineering & Testing, Inc. 813.299.2416 Comments: 105-1.2.3 1st Paragraph, 2nd Sentence place comma, QC submit quantites and how exactly do you track quantities on a STRG anyway? Testing is done by lineal distance, billing is done by SY, and the materials are ordered by the ton. Testing
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul08/files/1050000.resp.pdf?sfvrsn=a5ea2d58_0SP3300802.comm
acronyms; QC, LOT, ASTM, FM, etc. Response: 2. Definition for Process Control Testing seems to define a role, rather than a testing process. Response: 3. Some bullet points seem to be definitions, Comments: (1-18-18) 1. Please list the areas not suitable for testing with laser profiler. You, not suitable for testing with the laser profiler……….” Define areas not suitable. We’ve had FC-9.5, to schedule equipment(laser), confirm this is required each time prior to testing
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/july-2018/review/comments-responses/sp3300802.comm.pdf?sfvrsn=fef0b586_09370000.FHWA
Structures Manual. Use only Test undercut anchor systems tested in accordance with the International, in accordance with Section 6 and shall include certified test reports from an independent testing, . The application shall be made in accordance with 6-1Section 6 and shall include certified test reports from an independent testing laboratory which shows the material system meets all, Minimum Performance Requirements (FM 5-568): When tested in accordance with FM 5-568, the adhesive
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan12/files/9370000.fhwa.pdf?sfvrsn=585bd2a5_09370000.fhwa
Structures Manual. Use only Test undercut anchor systems tested in accordance with the International, in accordance with Section 6 and shall include certified test reports from an independent testing, . The application shall be made in accordance with 6-1Section 6 and shall include certified test reports from an independent testing laboratory which shows the material system meets all, Minimum Performance Requirements (FM 5-568): When tested in accordance with FM 5-568, the adhesive
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan12/files/9370000.fhwa4dd8286584de4ef9b9901d845c048c30.pdf?sfvrsn=78f92817_0Staff-Director-Agenda-Package-April-2021_0728
testimony and evidence upon which appeal is to be based. The needs of hearing or visually impaired, offices and is willing to testify at Congressional Hearings. o Chairman DeFazio will be submitting
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/mpoac_website/meetings/2021/staff-director-agenda-package-april-2021_0728.pdf?sfvrsn=fe005c78_14620000.impl
device. When testing the 6.5 gallon device, ensure an accuracy of 3% (test device volume) and 6, , perform a fluidity test on a per batch basis. For fluidity tests done on a per batch basis, perform, requirements are met. Discard grout used for testing fluidity. 3.Perform fluidity test for each tendon, possible subcomponents is required for PT system and component testing; however, subcomponents, filled duct and anchorage assemblies free from leaks, blockages, and voids. Provide sufficient test
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/january-2016/review/implemented/4620000.impl.pdf?sfvrsn=fcd5fdfc_0SS4070000.IMP
of all quality control testing and inspections in accordance with Sections 346. Prepare,cure,andtest the test cylinders in accordance with ASTM C 31 and ASTM C 39 test methods. The use of 4 x 8 inch test cylinders is allowed for the testing of precast culverts, provided that it meets, with debris. 407-4 Materials Acceptance and Testing. 407-4.1 General: Meet concrete materials, testing, shipping strength test cylinders to the same curing conditions as the precast concrete sections. 28-day
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan07/files/ss4070000.imp.pdf?sfvrsn=8ae1789f_0SS4070000
of all quality control testing and inspections in accordance with Sections 346. Prepare,cure,andtest the test cylinders in accordance with ASTM C 31 and ASTM C 39 test methods. The use of 4 x 8 inch test cylinders is allowed for the testing of precast culverts, provided that it meets, with debris. 407-4 Materials Acceptance and Testing. 407-4.1 General: Meet concrete materials, testing, shipping strength test cylinders to the same curing conditions as the precast concrete sections. 28-day
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2007/files/ss4070000.pdf?sfvrsn=38b09cfb_04070000.origind
methods. The use of 4 x 8 inch test cylinders is allowed for the testing of precast culverts, . Themanufacturer is permitted to verify the shipping strength test, before 28 days, by testing, to the potential for clogging with debris. 407-4 Materials Acceptance and Testing. 407-4.1 General: Meet concrete materials, testing, inspection, and acceptance requirements of Section 346, as modified, responsibility for performance of all quality control testing and inspections in accordance
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul08/files/4070000.origind.pdf?sfvrsn=38a9758_0SS4070000
potential for clogging with debris. e ce d test the test cylinders in accordance with ASTM C 31 and cured Test nce with the Structures Design Guidelines, for any design Submit design calculations, shop e ed ould be onstruct the connection 407-4 Materials Acceptance and Testing. 407-4.1 General: Meet concrete materials, testing, inspection, and acceptance requirements of Section 346, ; therefore, assume responsibility for performance of all quality control testing and inspections in accordan
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2010/files/ss4070000.pdf?sfvrsn=c7407e17_0SS4070000
potential for clogging with debris. e ce d test the test cylinders in accordance with ASTM C 31 and cured Test nce with the Structures Design Guidelines, for any design Submit design calculations, shop e ed ould be onstruct the connection 407-4 Materials Acceptance and Testing. 407-4.1 General: Meet concrete materials, testing, inspection, and acceptance requirements of Section 346, ; therefore, assume responsibility for performance of all quality control testing and inspections in accordan
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2009/files/ss407000030f417e1210446a899336eb677ac4405.pdf?sfvrsn=27c265a5_04070000.impl
. The use of 4 x 8 inch test cylinders is allowed for the testing of precast culverts, provided, to verify the shipping strength test, before 28 days, by testing compressive strength cylinders, to the potential for clogging with debris. 407-4 Materials Acceptance and Testing. 407-4.1 General: Meet concrete materials, testing, inspection, and acceptance requirements of Section 346, as modified herein, responsibility for performance of all quality control testing and inspections in accordance with Sections 346
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul08/files/4070000.impl.pdf?sfvrsn=51880d11_0