2223 search results for bridge inspection

E50D2

 Florida Department of Transportation Bid Solicitation Notice and Approximate Quantities Letting:05240507Call Order:004Proposal:E50D2District:05 Counties:ORANGE, OSCEOLA Road Name:Site Specific Pipe & Box Culvert Desilting Limits:Midpoint Project(s):44400217206(*)Federal Aid No:N/A Total Roadway Length:0.000MilesContract Days:170 Total Bridge Length:0.000MilesLetting Date:05/07/24, " OR GREATERLF650.000 E432- 4-STORM SEWER INSPECTION (VIDEO CAMERA)LF5,400.000 Page 6 Bid

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d5/lettings/2024/may07/e50d2.pdf?sfvrsn=105d8e2f_1

Section112-33017

Transportation Officials/National Steel Bridge Alliance (AASHTO/NSBA) Steel Bridge Collaboration, Steel Bridge Fabrication QC/QA Guide Specification S4.1 American Welding Society (AWS) AASHTO/AWS D1.5/D1.5M, Bridge Welding Code American Welding Society (AWS) D1.1/D1.1M, Structural Welding Code – Steel, , and the consultants who are involved in the verification and other quality assurance inspection and testing, verification inspection consultant. WPSs that require qualification testing shall be submitted

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2017/july-2017/materials-manual/section112-33017.pdf?sfvrsn=b82433fa_1

Section111V2-726redln

. Quality Based Traveler System C16. Fracture Control Plan (Bridge Only) D. Inspection Page/Section, ........................................................................... 10 11.1.13 COMMERCIAL INSPECTION, 11.1.17 PRE-QUALIFICATION OF BRIDGE BEARINGS.......................................... 13 11.1.18, Highway Transportation Officials (AASHTO) Load Resistance and Factor Design (LFRD) Bridge Construction, D1.5, Bridge Welding Code American Welding Society (AWS) D1.1 Structural Welding Code - Steel

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2026-27/materials-manual/redline/section111v2-726redln.pdf?sfvrsn=1875a4d5_1

2024nov-thu03-SRCUpdate

, and two semi-trucks with steel blocks for bridge testing.  Indoor facility: 50’ x 100’ strong floor, .  Projects: 3 in-house, 10 contracted, 2 bridge tests. Ready to Use To p i c s Source: https, Footings 06/28/2022 Aluminum Lightweight Orthotropic Deck Evaluation Project 2/17/ 2 0 17 Inspection, /structuresresearchcenter/completedresearch.shtm 9 INITIAL INSPECTION: 1. Perform a close investigation, : Prefabricated bridge substructure elements can be used to accelerate construction. UHPC is an ideal

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/training/transportationsymposium/2024-november/2024nov-thu03-srcupdate.pdf?sfvrsn=4eb49c14_1

2024nov-thu03-SRCUpdate

, and two semi-trucks with steel blocks for bridge testing.  Indoor facility: 50’ x 100’ strong floor, .  Projects: 3 in-house, 10 contracted, 2 bridge tests. Ready to Use To p i c s Source: https, Footings 06/28/2022 Aluminum Lightweight Orthotropic Deck Evaluation Project 2/17/ 2 0 17 Inspection, /structuresresearchcenter/completedresearch.shtm 9 INITIAL INSPECTION: 1. Perform a close investigation, : Prefabricated bridge substructure elements can be used to accelerate construction. UHPC is an ideal

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/training/transportationsymposium/2024-june/2024nov-thu03-srcupdate.pdf?sfvrsn=3d994966_1

Sample Resumes

inspection of the bridge. John supervised the inspection of the girders and deck for this bridge, Engineer and supervised the inspection of pile bents, abutments, and deck using AASHTO LRFD Bridge, . Rev. 10/31/25 www.fdot.gov Tips for Prequalification in Work Group 4 – Bridge Design Please refer, . in the package for bridge qualification. Qualifications are based upon design experience of the individual, corridor/road and/or bridge projects. Each candidate must validate work experience demonstrating

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/procurement/prequalification-applications/sample-resumes.pdf?sfvrsn=4038eb2e_3

Section113V2-724cln

hours of PAUT inspection specific to AASHTO / AWS D1.5 Bridge Welding Code. 4. Individuals who, Array Ultrasonic Testing on Florida Department of Transportation structural steel bridge projects, /AWS D1.5 Bridge Welding Code Topic No.: 675-000-000 Materials Manual Effective: January 1, 2024, Testing on Structural Steel for use in bridge components. These requirements and activities pertain to the procedure, operator qualification, and inspection process. Provide this information

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/materials-manual/section113v2-724cln.pdf?sfvrsn=38a2c4e2_1

Section113V2-726

of Transportation structural steel bridge projects. 11.3.2 AUTHORITY Section 20.23(3)(a) and 334.048(3, and Certification in Nondestructive Testing AASTHO/AWS D1.5 Bridge Welding Code Topic No.: 675-000-000, on Structural Steel for use in bridge components. These requirements and activities pertain to the procedure, operator qualification, and inspection process. Provide this information, of the ‘Advanced Ultrasonic Examination’ Annex of the AASHTO / AWS D1.5 Bridge Welding Code. 11.3.6

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2026-27/materials-manual/section113v2-726.pdf?sfvrsn=418b472a_1

4002102-724origind

of individual cracks at an inspection interval determined by the Engineer to determine if cracks are active or dormant after initial inspection. The Engineer will perform all final bridge deck crack, , and a minimum of 7 days after the bridge has been opened to full unrestricted traffic. Additionally, for bridge decks that require planing, the Engineer will perform bridge deck crack measurements once

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/internal/4002102-724origind.pdf?sfvrsn=e379f625_1

Asset Maintenance Documents

Number 000-625-001 Environmental Policy Bridge and Overhead Sign and HMLP Damage Assessment DME Memo, - Ch. 13 Manual on Uniform Traffic Control Devices (MUTCD) Open Roads Policy AASHTO Movable Bridge Inspection, Evaluation and Maintenance Manual Utility Accommodations Manual Topic Number 375-040-020 Procurement of Commodities and Contractual Services Topic Number 850-010-035 Bridge Load Rating, Specifications for Road and Bridge Construction (including implemented revisions) Applicable specifications from

https://www.fdot.gov/maintenance/Cont/AM/asset-maintenance-documents

Design-Build Conflict of Interest - Questions and Answers

inspection staffing/availability as it relates to CEI services on a Design-Build type contract involving a movable bridge. Can the engineering firm providing the services, in movable bridge category and this project being a design/build type contract, CEI firms have, the design/build contract. On conventional movable bridge projects, the Engineer of Record (mechanical/electrical) would be available to do periodic inspections thru post design services

https://www.fdot.gov/construction/conflictofinterest/designbuildconflictanswers.shtm

CM-659-01 Mast Arm Span Wire and Pole Mounting Assembly

and understands the provisions of Sections 659 and 995 of the FDOT Standard Specifications for Road and Bridge, Applicant may provide comments in this field. Physical Inspection 2 995-7.1 All fastening hardware, Review and Physical Inspection FORMTEXT Indicate location of requested information in submittal, Inspection FORMTEXT Indicate location of requested information in submittal. 4   Metallic mounting, this requirement. Document Review and Physical Inspection FORMTEXT Indicate location of requested

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/traffic/traf_sys/compliance-matrices-2022/cm-659-01-mast-arm-span-wire-and-pole-mounting-assembly.docx?sfvrsn=3232f6c3_1

OET-25-03

for bridge inspection, maintenance, and monitoring are not often interconnected which causes concerns, transformation and integration of TxDOT bridge inspections, design, and maintenance activities, enabling more scientific decision-making and bridge management practices with broad impacts to TxDOT operations. • “A Bridge Digital Twin for Enhancing Transportation Resilience and Asset Management, ://rip.trb.org/View/1902374 Summary: The results from this study will assist on the bridge inspection

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/research/program_information/contract.development/ballot/oet-25-03.pdf?sfvrsn=be7aaa6_2

OET-25-03

for bridge inspection, maintenance, and monitoring are not often interconnected which causes concerns, transformation and integration of TxDOT bridge inspections, design, and maintenance activities, enabling more scientific decision-making and bridge management practices with broad impacts to TxDOT operations. • “A Bridge Digital Twin for Enhancing Transportation Resilience and Asset Management, ://rip.trb.org/View/1902374 Summary: The results from this study will assist on the bridge inspection

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/research/program_information/contract.development/ballot/oet-25-0.pdf.pdf?sfvrsn=4f170aae_7

CM-700-02 Highlighted Sign

995 of the FDOT Standard Specifications for Road and Bridge Construction and all implemented, . FORMDROPDOWN FORMTEXT Applicant may provide comments in this field. Physical Inspection TERL Test Cases, in this field. Document Review, Physical Inspection, and Functional Inspection The following compliance, and Physical Inspection FORMTEXT Indicate location of requested information in submittal. TERL Test Cases, Review and Physical Inspection FORMTEXT Indicate location of requested information in submittal. TERL

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/traffic/traf_sys/compliance-matrices-2022/cm-700-02-highlighted-sign.docx?sfvrsn=6dc726b6_1

CM-700-05 Dynamic Message Sign

of Section 995 of the FDOT Standard Specifications for Road and Bridge Construction and all implemented, Applicant may provide comments in this field. Physical Inspection TERL Test Cases (Steps): DMS002, , Physical Inspection and Functional Inspection The following compliance matrix criteria (referencing, this requirement. Document Review and Physical Inspection FORMTEXT Indicate location of requested, provide comments in this field. Physical Inspection TERL Test Cases (Steps): DMS002 (Step 2

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/traffic/traf_sys/compliance-matrices-2022/cm-700-05-dynamic-message-sign.docx?sfvrsn=5966df18_1

Scope of Services

Concrete Plant Inspection and Testing:……………………………………………………………………13 15.5 Pre-Stress and Precast Production Facility Inspection and Testing:………………………….13 15.6 Earthwork, of the contract, conduct laboratory inspections, review actual test methods and procedures, review test, and Bridge Scope Doc. November 20, 2025 6 Construction as amended by contract documents • FDOT, Guideline • Southern Pine Inspection Board Standards • Pile Installation Plan (PIP) • Auger Cast

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/materials/contract/documents/scope-of-services.pdf?sfvrsn=2536d968_4

Scope of Service

15.3Laboratory Testing:………………………………………………………………………………………………….13 15.4Concrete Plant Inspection and Testing:……………………………………………………………………13 15.5Pre-Stress and Precast Production Facility Inspection and Testing, inspections, review actual test methods and procedures, review test results and reports, review invoice, Department of Transportation (FDOT) Standard Specification for Road and Bridge Construction, Southern Pine Inspection Board Standards Pile Installation Plan (PIP) Auger Cast pile installation

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/materials/contract/documents/scope-of-service.docx?sfvrsn=d6100b09_4

E4X25

), monitor structures (inspection, settlement), bridge (removal, superstructure, expansion joint, No: N/A Total Roadway Length: 2.044 Miles Contract Days: 224 Total Bridge Length: 0.012 Miles, is required for this project. PLEASE READ STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION, (44766515201) LS 1.000 0400- 2- 4 CONC CLASS II, BRIDGE SUPERSTRUCTURE CY 9.500 0400- 2- 10 CONCRETE CLASS II, APPROACH SLABS CY 14.800 0415- 1- 4 REINFORCING STEEL - BRIDGE SUPERSTRUCTURE LB

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d4/lettings/2024/aug02/e4x25.pdf?sfvrsn=59eaff3f_1

E1W90

COUNTY - BRIDGE-REPAIR/REHABILITATION Limits: 03010000 Project(s): 43504315201(*) Federal Aid No: N/A Total Roadway Length: 0.048 Miles Contract Days: 240 Total Bridge Length: 0.048 Miles Letting Date, countermeasure at Bridge Nos. 030039, 030068 and 030071 in Collier County. Page 7 Bid Solicitation Notice, - INSPECTION AND SETTLEMENT MONITORING (43504315201) LS 1.000 0110- 1- 1 CLEARING & GRUBBING, 0400- 4- 5 CONCRETE CLASS IV, BRIDGE SUBSTRUCTURE CY 202.800 0401- 70- 4 RESTORE SPALLED AREAS

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d1/lettings/2025/jan16/e1w90.pdf?sfvrsn=87e8f633_1
20 of 2223 results