9191 search results for test
9320103Origin
by the manufacturer. When a manufacturer’s product is tested and approved by the Department using, TYPE Test Method Type A TypeB TypeC TypeD Flow(maximum) MIL S 8802 0.3 inches [7.6 mm, SEALANT TYPE Test Method Type A TypeB TypeC TypeD Tack-freetime at 77 ± 3ºF [25 ± 1.5ºC] and 45, ] minimum 9320103.doc All Jobs 4 SILICONE SEALANT TYPE Test Method Type A TypeB TypeC TypeD, failure and adhesion, 10 cycles at +100/-50 % (joints 2” wide) 932-1.3.3 Methods of Test: Flow
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan07/files/9320103origin.pdf?sfvrsn=8e2c3a31_04500000Respon
. The producer should address the aforementioned testing requirements as part of the proposed operation, Inspection and Testing: The Engineer will perform periodic inspections, sampling, and testing, . The quality assurance inspection and testing will be performed in accordance with Section 8.1, specifications that place contractual requirements upon the Engineer to "run tests to ensure, is necessary to verify the accuracy and integrity of the contractor's tests. This spec revision now
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul06/files/4500000respon.pdf?sfvrsn=504f6aa1_0FHWA Memos
: 455-2.10 Disposition of Tested Piles/Shafts: After completing testing, cut off the tested piles/shafts, two Quality Control (QC) density tests with a 12 inch depth of measurement: one QC density test, and test piling, the Contractor may initially predrill holes to a depth up to 20% of the test pile, in the same manner as the test piles. When installing piles in compacted fill, predrill the holes, or equal to 30 tons per square foot of gross pile area as determined by the Dynamic Load Testing
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/fhwa/fhwa-memos.pdf?sfvrsn=851f51e4_2E5P67 WPI 42204217202
. Customer Complaints FDOT’s unilateral and unwavering testimony regarding “Resolution for Customer, . The majority of exhibits and verbal testimony by Foundation Services attempting to support
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/construction/constadm/drb/decisions/d5/e5p67-wpi-42204217202.pdf?sfvrsn=6aaf7812_2D7 plan quantities for Embankment and Excavation
and the hearing testimony, it appears that K&R was required to import additional embankment material, in the previous Issue 1 and will not be repeated here. 1. Hearing testimony and documentation submitted
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/constadm/drb/decision/d7/d7-plan-quantities-for-embankment-and-excavation.pdf?sfvrsn=25c2f0d9_06840000.FHWA
General: Subject the MFES to field acceptance tests (FATs). Develop and submit a test plan for FATs, . Complete the tests within five calendar days. 6840000.D01 All Jobs 7684-1.4.2 Field Testing: Once, and replaced. 7684-2.4 Testing: 7684-2.4.1 General: Subject the Device Server to field acceptance tests, . 7684-2.4.2 Field Testing: Perform local field operational tests at device server field sites, acceptance tests (FATs). Develop and submit a test plan for FATs to the Engineer for consideration
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/january-2014/review/fhwa/6840000.fhwa.pdf?sfvrsn=af2bb97e_03370206.impl
compliance with the above tests. 337-2.7.2 Cellulose Fibers: Use cellulose fibers meeting the following, tests. SUBARTICLE 337-3.2.1 (of the Supplemental Specifications) is deleted and the following, to testing) will not be required as part of 334-5.1.1.1. 3.ThestandardLOTsizeofFC-5willbe2,000tons, with 334-5.1.8. No density testing will be required for these mixtures. Table 337-2 FC-5 Master Production, size of n = 1 from the verified mix design 337-6.2.1.1 Individual Test Tolerances for FC-5
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul10/files/3370206.impl.pdf?sfvrsn=c6f83548_01050000
Certification of Compliance. 105-2.1 General: Provide qualified personnel for sampling, testing, the course of sampling, testing and inspection. Continuance of the Department’s qualifications, with their Training Identification Numbers (TIN) for all technicians performing sampling, testing and inspection for both field and laboratory tests. Include employed and subcontracted technicians, that are supplemental to the Quality Control sampling and testing program described in the Contract
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul03/files/1050000.pdf?sfvrsn=7934f546_024.25_FDOT_Annual_Report_Final_Signed
Department equipment and vehicles in the course of the test proctoring. The OIG provided, ., (CMEC) Construction Training and Qualification Program. Two concrete field-testing kits. Docusign, accolade is more than a symbol of our success, it's a testament to our team's relentless
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/ig/reports/24-25_fdot_annual_report_final_signed.pdf?sfvrsn=750a6271_1SS4130000
test data and results showing the product has been tested in accordance with the requirements, pounds/yd 3 0.00 pounds/yd (criteria of 1.5) at 1/2 inch level; 3 Water absorption test (ASTM C, Series II - cube test Water weight gain 85% reduction minimum Absorbed chloride 87% reduction, numbers of the containers certified. 413-2.4.3 Materials Sampling for Tests: The Engineer may, or equal to 35 at 7 days. Coordinate with the Engineer to conduct a preliminary on-site friction test
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2014/files/ss4130000.pdf?sfvrsn=807a8441_0SS7820000
to witness all tests. 782-1.4.2 Field Test Requirements: Perform local field operational tests, Testing: 782-2.5.1 General: Submit a detailed system acceptance test plan to the Engineer, of the equipment’s installation. At minimum, include in the video display system test the testing of each color, performs all required functions during and after being subjected to the environmental testing procedures, repellant product prior to final acceptance. 782-1.4 Testing: 782-1.4.1 General: Subject
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2013/files/ss7820000.pdf?sfvrsn=68cb07c9_07820000.FHWA
to witness all tests. 7820000 All Jobs 782-1.4.2 Field Test Requirements: Perform local field, on an as-needed basis. 782-2.5 Testing: 782-2.5.1 General: Submit a detailed system acceptance test, test the testing of each color video monitor type, each secondary display output at workstations, during and after being subjected to the environmental testing procedures described in NEMA TS2, repellant product prior to final acceptance. 782-1.4 Testing: 782-1.4.1 General: Subject the equipment
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/january-2014/review/fhwa/7820000.fhwa.pdf?sfvrsn=93166e1e_00060100LS.fhwa
Requirements: Material is accepted by material sampling and testing requirements for the following, , title of certification person and test results in each product listed in the Department, prior to placement or utilization. Retain test results for a minimum of three years. 6-1.3.5, , identification and type of material, FPID, Contract Number, county, test results of the material, that the date of the manufacturer’s certification is current to the shelf life of the product. Retain test
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan10/files/0060100ls.fhwa.pdf?sfvrsn=c5281c6c_06950000-122impl
polling and processing software. Any substitute software modules submitted must be tested, the bonding agent ensuring the slot is completely full with no voids beneath the sensor. 695-3.2.2 Test Requirements: Perform the manufacturer’s recommended on-site pre-installation test to determine, that pass the pre-installation test. Record all test results by lane on the warranty form provided by the manufacturer and leave a copy in the cabinet. Repeat the test at the termination point
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/january-2022/review/implemented/6950000-122impl.pdf?sfvrsn=b26633ad_2SS7850000
resistance, soil resistivity, and current flow. Conduct the test by using the fall-of-potential method. Provide the Engineer with written, certified test results for each testing location. Illegible hand, , or certifying the test; 6. The local environmental and soil conditions at the time of testing; 7, accessible for inspection, testing, and maintenance. Place the main ground rod in the electrical pullbox, of influence radius is maintained. 785-2.3.3 Ground Resistance Testing and Certification: Measure the ground
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2012/january-2012/workbook/ss7850000.pdf?sfvrsn=9c00c44d_04620702-724IMPL
pounds per gallon. a. Test for presence of chlorides and oils in discharged water before placing, not install permanent tendons before completion of testing as required by this Section or the Contract Documents. The only two exceptions are: a. Tendon to be tested by “Theoretical Elongation Verification” may be installed for test; and, b. Transverse tendons may be pre-installed in precast, tolerances, additional tests may be required, at the Engineer’s discretion and without additional
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/implemented/4620702-724impl.pdf?sfvrsn=7b8125e0_1CM-650-02 Vehicular Traffic Signal Assembly
. Physical Inspection TERL Test Cases (Steps): VTSA002 (Step 1) FORMTEXT FORMTEXT Init, in submittal. TERL Test Cases (Steps): VTSA001 (Step 1) FORMTEXT FORMTEXT Init, of requested information in submittal. TERL Test Cases (Steps): VTSA001 (Step 2) FORMTEXT, Inspection FORMTEXT Indicate location of requested information in submittal. TERL Test Cases (Steps, . Physical Inspection TERL Test Cases (Steps): VTSA002 (Step 3) FORMTEXT FORMTEXT Init
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/traffic/traf_sys/compliance-matrices-2022/cm-650-02-vehicular-traffic-signal-assembly.docx?sfvrsn=33da1e24_1SS3300000
until the proper conditions h been restored. 330-2.2 Minimum Process Control Testing Requirements: Perform, as a inimu,thefoll mmng activities at the testing frequencies provided below: Asphalt Plant, 1,000 tons, perform these tests a minimum of two times incoming material as it is stockpiled, day. Quality Control tests used in the acceptance decision may be used to fulfill this requirement, or equal to 105 lb/yd 2 ) and an approved rolling pattern is used in lieu of density testing
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2009/files/ss3300000.pdf?sfvrsn=9b33ca44_0chgtab
. For test piles, to include the costs of dynamic load tests in the cost of the test piles. For production piles, to pay dynamic load tests in additional feet of piling. Usage note: All Jobs 3-31-08, 3-13-08 5-28-08 1-09 SS3360000 New SS. To modify the equipment, testing and certification requirements, . To require signed and sealed test reports and clarify the requirements for a restrained test. Usage, no longer used by t he Department and to include test methods for evaluation of Types A and B
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2009/january-2009/workbook/chgtab.pdf?sfvrsn=91462f13_09710107.FHWA
of lead or arsenic in accordance with Environmental Protection Agency testing methods 3052, 6010B, stripe materials shall contain no more that 5.0 ppm lead by weight when tested in accordance, Agency testing methods 3052, 6010B, 6010C
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul13/files/9710107.fhwa.pdf?sfvrsn=cb6e4316_0