5764 search results for Standard Specifications

SS7860000

in accordance with the AASHTO 1994 Standard Specifications for Structural Supports for Highway Signs, either in serial format using an Electronic Industries Alliance (EIA) standard EIA-232 communication, device requiring a source input other than the standard 120 V AC , supply the appropriate means, Note (FPN) No. 4, and meet all other applicable standards, specifications and local code, Requirements: Provide detection systems that meet all specifications during and after being subjected

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2007/january-2007/workbook/ss7860000.pdf?sfvrsn=c23d1e59_0

SS7860000

in accordance with the AASHTO 1994 Standard Specifications for Structural Supports for Highway Signs, either in serial format using an Electronic Industries Alliance (EIA) standard EIA-232, device requiring a source input other than the standard 120 V AC , supply the appropriate means, Print Note (FPN) No. 4, and meet all other applicable standards, specifications and local code, Requirements: Provide detection systems that meet all specifications during and after being subjected

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2008/january-2008/workbook/ss7860000.pdf?sfvrsn=a93a92be_0

SS7860000

in accordance with the AASHTO 1994 Standard Specifications for Structural Supports for Highway Signs, either in serial format using an Electronic Industries Alliance (EIA) standard EIA-232 communication, device requiring a source input other than the standard 120 V AC , supply the appropriate means, Note (FPN) No. 4, and meet all other applicable standards, specifications and local code, Requirements: Provide detection systems that meet all specifications during and after being subjected

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2009/january-2009/workbook/ss7860000c0e85d9b8c934ac1ac8f18532a453ff0.pdf?sfvrsn=984735fe_0

9950100-722impl

: The light intensity of the yellow indications shall meet the minimum specifications of Society of Automotive Engineers (SAE) standard J595 for Class 1 (Directional Flashing Optical Warning Devices, Electrical Specifications: Equipment must operate on solar power or a nominal voltage of 120 V, Environmental Specifications: All electronic assemblies shall operate as specified during and after being, with a standard traffic signal's two inch I.D. opening and must be capable of providing positive

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/implemented/9950100-722impl.pdf?sfvrsn=4ee62e95_2

Chapter1s2Redline

No. 700-010-04 , Form No. 700-010-04, FDOT Standard Specifications for Road & Bridge Construction Standard Specifications for Road and Bridge Construction 1.2.4 Scope This document was created to assist, conflicts or due to other unforeseeable conditions as spelled out in Standard Specifications 8-7.3.2, Contract Durations 1-2-3 1.2.7 Initiating Specifications/Alternative Contracting Techniques, with the project specifications and may require the addition of other specifications. Make sure these do

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/manuals/cpam/newhistory/chapter1s2redline.pdf?sfvrsn=135c9a41_8

TP-12-19-25BSN

of the Standard Specifications for Road and Bridge Construction, or as amended by the project Specifications Package or any Supplemental Specifications Packages, if it is determined that multiple responsive, specified in the most current edition of the Department’s Standard Specifications for Road, and 3-7 of the Standard Specifications, the successful bidder shall execute the necessary contract, description and specifications. If deemed necessary by the Department, certain maintenance contracts

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/tp/lettings/2025/dec19/tp-12-19-25bsn.pdf?sfvrsn=546f4e73_1

D1-01-15-26BSN

in the most current edition of the Department’s Standard Specifications for Road and Bridge Construction, .) EXECUTION OF CONTRACT Pursuant to Subsections 3-6 and 3-7 of the Standard Specifications, in the project description and specifications. If deemed necessary by the Department, certain, on this website. IDENTICAL BIDS After consideration in accordance with Article 3-1 of the Standard Specifications for Road and Bridge Construction, or as amended by the project Specifications Package or any

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d1/lettings/2026/jan15/d1-01-15-26bsn.pdf?sfvrsn=b93e086_1

TP-05-14-24BSN

After consideration in accordance with Article 3-1 of the Standard Specifications for Road and Bridge, of the Department’s Standard Specifications for Road and Bridge Construction. Insurance companies, Solicitation Notice Page 4 Pursuant to Subsections 3-6 and 3-7 of the Standard Specifications, https://www.fdot.gov/contracts/cpp-online- ordering/bidder-assist.shtm, Standard Specifications, description and specifications. If deemed necessary by the Department, certain maintenance

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/tp/lettings/2024/may14/tp-05-14-24bsn.pdf?sfvrsn=bc5408ec_3

2024FDM232Signalization

complement the basic highway design and comply with: • Standard Specifications , • Standard Plans, . 232.1.1 Structural Supports AASHTO’s LRFD Specifications for Structural Supports for Highway Signs, ) is the standard light source for all signal indications. 232.1.5 Retroreflective Signal Backplates Install, ) based on the Department’s Standard K factor and not a peak to daily (P/D) ratio based, in the Standard Plans , Index 660-001 and are suitable for most locations. Index 600-001 allows for minor

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/review/2024fdm232signalization.pdf?sfvrsn=15204b38_1

2024FDM232Signalization

complement the basic highway design and comply with: • Standard Specifications , • Standard Plans, . 232.1.1 Structural Supports AASHTO’s LRFD Specifications for Structural Supports for Highway Signs, Diode (LED) is the standard light source for all signal indications. 232.1.5 Retroreflective Signal, Hourly Volume (DHV) based on the Department’s Standard K factor and not a peak to daily (P/D, detection loops are detailed in the Standard Plans , Index 660-001 and are suitable for most

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/2024/2024fdm232signalization.pdf?sfvrsn=696f6a75_1

2025FDM232Signalization

complement the basic highway design and comply with: • Standard Specifications , • Standard Plans, . 232.1.1 Structural Supports AASHTO’s LRFD Specifications for Structural Supports for Highway Signs, ) is the standard light source for all signal indications. 232.1.5 Retroreflective Signal Backplates, Volume (DHV) based on the Department’s Standard K factor and not a peak to daily (P/D) ratio based, are detailed in the Standard Plans , Index 660-001 and are suitable for most locations. Index

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/2025/review/2025fdm232signalization.pdf?sfvrsn=91ad6b21_5

2025FDM232Signalization

complement the basic highway design and comply with: • Standard Specifications , • Standard Plans, . 232.1.1 Structural Supports AASHTO’s LRFD Specifications for Structural Supports for Highway Signs, Emitting Diode (LED) is the standard light source for all signal indications. 232.1.5 Retroreflective, the Design Hourly Volume (DHV) based on the Department’s Standard K factor and not a peak to daily (P/D, intersection. Vehicle detection loops are detailed in the Standard Plans , Index 660-001

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/2025/2025fdm232signalization.pdf?sfvrsn=cfa6091f_1

6490200FHWA

Tallahassee, Florida 32312 Re: State Specifications Office Section: 649 Proposed Specification, , Signature on File Daniel Strickland, P.E. State Specifications Engineer DS/jb Attachment cc: Florida, Product List (APL). 649-2.21 Pole Assembly: Use pole assemblies as shown in the Standard Plans when standard mast arm assemblies, standard strain pole assemblies, or standard steel CCTV pole, : Use pole assemblies as shown in the Standard Plans when standard mast arm assemblies, standard

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2025-26/review/fhwa/6490200fhwa.pdf?sfvrsn=9b2e9d89_1

6350100FHWA REVISED

Tallahassee, Florida 32312 Re: State Specifications Office Section: 635 Proposed Specification, , P.E. State Specifications Engineer DS/dh Attachment cc: Florida Transportation Builders' Assoc, pull and splice boxes in accordance with Standard Plans, Index 635-001. Ensure pull and splice boxes, Vaults: Install fiber optic vaults in accordance with Standard Plans, Index 635-005. 635-3.4 Toll, with Standard Plans, Index 634-002. 635-3.46 Mounted Junction Boxes: Install mounted junction boxes

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2025-26/review/fhwa/6350100fhwa-revised.pdf?sfvrsn=dff313ae_1

6490202FHWA

, Florida 32312 Re: State Specifications Office Section: Proposed Specification: 6490202 Galvanized, Strickland, P.E. State Specifications Engineer DS/jb Attachment cc: Florida Transportation Builders, pole assemblies as shown in the Standard Plans when standard mast arm assemblies, standard strain pole assemblies, or standard steel CCTV pole assemblies are required by the Contract Documents, in the Standard Plans when standard mast arm assemblies, standard strain pole assemblies

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2026-27/review/fhwa/6490202fhwa.pdf?sfvrsn=702e6219_1

2026FDM232Signalization

of signals should complement the basic highway design and comply with: • Standard Specifications, • Standard Plans, • Traffic Engineering Manual (TEM), • Structures Manual (Volume 3), • Manual, Structural Supports AASHTO’s LRFD Specifications for Structural Supports for Highway Signs, ) is the standard light source for all signal indications. 232.1.5 Retroreflective Signal Backplates, (DHV) based on the Department’s Standard K factor and not a peak to daily (P/D) ratio based

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/2026/review/2026fdm232signalization.pdf?sfvrsn=ebf88f59_2

1450300FHWA

, Suite 4200 Orlando, FL 32801 Re: State Specifications Office Section: 145 Proposed Specification, Specifications Engineer DS/jb Attachment cc: Florida Transportation Builders' Assoc. State Construction, requirements as specified in Standard Plans, Index 120-001. Meet the testing parameters set forth, a minimum density of 100% of the standard Proctor maximum dry density as determined by FM 1-T 099, in 120-10.6.1 “Standard Proctor Maximum Density Determination” except replace FM 1-T099 with FM 1-T180

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2026-27/review/fhwa/1450300fhwa.pdf?sfvrsn=3bbb721a_1

2026FDM232Signalization

of signals should complement the basic highway design and comply with: • Standard Specifications, • Standard Plans, • Traffic Engineering Manual (TEM), • Structures Manual (Volume 3), • Manual, Structural Supports AASHTO’s LRFD Specifications for Structural Supports for Highway Signs, ) is the standard light source for all signal indications. 232.1.5 Retroreflective Signal Backplates, (DHV) based on the Department’s Standard K factor and not a peak to daily (P/D) ratio based

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/2026/2026fdm232signalization.pdf?sfvrsn=b6e7138d_1

25I-006 Jacksonville Port Authority Final

policies and standard operating procedures. The scope of this audit was grant agreement G1V25, Department policies and standard operating procedures. We determined the invoices for grant, Administrative Code, and relevant Department policies and standard operating procedures. 2. Determine whether, Department policies and standard operating procedures. The following criteria were used to determine, , and 2023;  Employment, Procedures and Guidelines, Standard Operating Procedure (SOP) 1104

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/ig/reports/25i-006-jacksonville-port-authority-final.pdf?sfvrsn=30034878_1

Materials Acceptance and Certification Development

-standard JGS to ensure entries for Lump Sum contracts are compliant with Specifications Section 105, , Testing and Reporting Guide Standard JGS Instructions PDF (1.4MB) Non-standard JGS User Instructions PDF (4.4MB) Non-Standard JGS Materials Summary Worksheet by Material Category A spreadsheet, Administrators in creating and reviewing Non-standard JGS grouped by major material category, such as Soils, describes the MAC functions for the PA review of the standard JGS and non-standard JGS in MAC. Additional

https://www.fdot.gov/materials/mac/default.shtm
20 of 5764 results