4673 search results for Standard Specifications
6590000.impl
. Surfaces that mate to vehicular and pedestrian traffic signals must have a standard circular 72 tooth, as shown in Design Standards Index No. 17727. Torque specifications must be included with all assembly installation instructions if torque specifications are specified by the manufacturer. 659-2.2, with mill scale removed in accordance with Military Standard MIL-PRF-24712A or AAMA 2603-02 and must, hub must be powder-coat painted dull black (Federal Standard 595A-37038) with a reflectance value
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2015/january-2015/review/implemented/6590000.impl.pdf?sfvrsn=5985d372_05340000.FHWA
Re: State Specifications and Estimates Office Section 534 Proposed Specification: 5340000 Concrete, change, please call me at 414-4130. Sincerely, Daniel Scheer, P.E. State Specifications Engineer, 7. Utility locations 78. Non-standard precast componentost and panel details 89. Non-standard post and pile connection details 10. Non-standard Post Cap Details 911. Lifting devices 534-5, , and panel joints 6. Existing and proposed ground elevations 7. Non-standard precast component
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/july-2014/review/fhwa/5340000.fhwa.pdf?sfvrsn=b2203209_02007_Use of Nondestructive Techniques to Estimate the Allowable Vibratory Compaction Level during Construction
. This standard is very conservative (Henwood and Haramy 2002). 2.3.2.3 FDOT Construction Specifications Section 455 of the FDOT Standard Specifications for Road and Bridge Construction (FDOT 2004, specifications have generally been implemented by highway agencies. Larger vibratory rollers are often, blasting level criteria, and the German DIN 4150 Standard level for human annoyance) were selected, of Specifications worksheet..................................................5-4 FL/DOT
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/materials/pavement/research/reports/fcpe/2007_use-of-nondestructive-techniques-to-estimate-the-allowable-vibratory-compaction-level-during-construction.pdf?sfvrsn=e1e3bf6a_1D2-03-13-24BSN
in accordance with Article 3-1 of the Standard Specifications for Road and Bridge Construction, or as amended by the project Specifications Package or any Supplemental Specifications Packages, if it, Pursuant to Subsections 3-6 and 3-7 of the Standard Specifications, the successful bidder shall execute, /contracts/cpp_online_ordering/bidder_assist.shtm , Standard Specifications for Road and Bridge, , unless stipulated in the project description and specifications. If deemed necessary
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d2/lettings/2024/mar13/d2-03-13-24bsn.pdf?sfvrsn=541bd96c_1Motorola steel post 7-25-24 plans
2015 W/ 2017-2022 AMMENDMENTS & FDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION FY, Specifications Xcessories Squared Development & MFG., INC. Part #: SB8‐CTA‐36‐G NSA Field Service Site, specifications. o The contractor shall provide shop drawings to POD Group prior to material ordering, will be built in accordance with the manufacturer’s specifications. 2. The Camera Post will be maintained in accordance with the manufacturer’s specifications. 3. Material grades are assumed as provided
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/traffic/test/approved-lpr/motorola-steel-post-7-25-24-plans.pdf?sfvrsn=a5978062_19960202-723FHWA
Specifications Office Section: 996 Proposed Specification: 9960202 Intelligent Transportation System, , Signature on file Daniel Strickland, P.E. State Specifications Engineer DS/ra Attachment cc: Florida, . 996-2.2.2 Lens: Standard definition PTZ cameras shall include a minimum 22x motorized optical zoom, with the ISO and IEC requirements detailed in the ISO/IEC 14496-10:2009 Standard. Cameras shall, Standard for 10/100 Ethernet connections. The camera shall have a minimum of one 10/100 Base-TX
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/fhwa/9960202-723fhwa.pdf?sfvrsn=4a119bf9_29900200-723FHWA
Specifications Office Section: 990 Proposed Specification: 9900200 Temporary Traffic Control Device, Design to include the language that was removed from the Standard Plans. The revision is associated, . Sincerely, Signature on file Daniel Strickland, P.E. State Specifications Engineer DS/vc Attachment, Protocol (NTCIP) 1101 base standard, including all amendments as published at the time of contract, objects implemented by the software do not interfere with the standard operation of mandatory objects
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/fhwa/9900200-723fhwa.pdf?sfvrsn=1c8d4d40_1Agency Term Contract - Barricades
of Transportation Standard plans, 2024-2025, Index No. 102, Florida Department of Transportation Standard Specifications Section 102, and bear the DOT approval number. Only barricade brands l isted, shall be the responsibility of the vendor. 13) PRODUCT REQUIREMENTS/SPECIFICATIONS Items furnished shall be standard products of the manufacturer or their suppliers, shall be new, unused, clean, in normal intended use. Any deviation from specifications indicated herein must be clearly
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/procurement/files_agency_term_contracts/agency-term-contract---barricades.pdf?sfvrsn=cb2fbc9a_194620702-724IMPL
manufacturer’s current standard technical specifications. Spray application is preferred; roller, positions and those shown in Standard Plans, Index 462-001: a. Top of tendon anchorage; b. Top, oriented 90 degrees from horizontal. 2. Provide the following at anchorages as shown on Standard, elastomeric coatings at anchorages as indicated in the Contract Documents and as shown on Standard, . See Standard Plans Index 462-002 and the Contract Documents for details on anchorages which
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/implemented/4620702-724impl.pdf?sfvrsn=7b8125e0_1F6011Non-TechSpecs
4.4.1.1 National Electrical Codes (NEC) 4.4.1.2 Standard Building Code 4.4.1.3 Standard Plumbing, in codes and/or standards the Contractor shall apply the most stringent code and/or standard, , locations, specifications, site layout and conditions. It shall be the Contractors responsibility to field, or manufacturer equipment component capabilities. 460-3-60 152 Tons • STANDARD TIER, supplies as required by the suggested manufacturing equipment specifications. 7.2.7 The Contractor
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d6/fco/f6011/f6011non-techspecs.pdf?sfvrsn=65ca2ece_1Chapter11s4Redline
Standard Specifications for Road and Bridge Construction 11.4.4 Overview of Adjustment Types Adjustments, the requirements in MAC and in the Standard Specifications. Any actions taken per Specification, Adjustments Non-asphalt Base Courses (white base) listed in Specifications Section 285, including, quantity pay items subject to Specifications Section 9-3.2 square yard pay items. Thickness is calculated in accordance with Specifications Section 285-7., and deficiencies are resolved per
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/manuals/cpam/newhistory/chapter11s4redline.pdf?sfvrsn=b134dd7b_37850000.FHWA
requirements from the Minimum Specifications for Traffic Control Signals and Devices (MSTCSD) and the Standard Specifications for Road and Bridge Construction (SSRBC). This activity is a planned part, 32303 Re: State Specifications and Estimates Office Section 785 Proposed Specification: 7850000, on file Daniel Scheer, P.E. State Specifications Engineer DS/dt Attachment cc: Florida, that meet the requirements of these minimum specifications, and are listed on the Department’s Approved
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2015/january-2015/review/fhwa/7850000.fhwa.pdf?sfvrsn=68e90a2_01200000.FHWA-REVISED
and clarify LOT as related to shoulders; define and clarify the terminology “standard minimum slope, the percentage of fines passing the No. 200 US Standard sieve in the A-2-4 material does not exceed 15%. 120-8.2.1.2 For A-1, Plastic materials (As designated in Design Standard Index 505) and A-2-4, is to be placed. 120-8.2.4 Placing Outside Standard Minimum Slope: The standard minimum slope is defined, that is unsuitable for normal embankment construction is to be used in the embankment outside the standard
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/july-2014/review/fhwa/1200000.fhwa-revised.pdf?sfvrsn=6f8b56a5_02025-FPDM
substitution for stabilization (meeting Standard Specifications, Section 290 as discussed below) does, in the Project Specifications. The Standard Specifications also provide that when 12-inches of Type B, of coefficients and variables are specified in this manual. They should be considered as standard values, into the Department’s Standard Operating System, Procedure No. 025-020-002. The final revisions and addenda, extension of weaker layers beyond stronger layers in a pyramidal effect (see Figure 2.1). Standard
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/pm/publications/2025-fpdm.pdf?sfvrsn=cfa567d_12025-FPDM-v2
Subbase substitution for stabilization (meeting Standard Specifications, Section 290 as discussed, in the Project Specifications. The Standard Specifications also provide that when 12-inches, of Standard Specifications, Section 290. The Specifications provide for use of the No Soak LBR Test, of coefficients and variables are specified in this manual. They should be considered as standard values, into the Department’s Standard Operating System, Procedure No. 025-020-002. The final revisions and addenda
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/pm/publications/2025-fpdm-v2.pdf?sfvrsn=7b53982a_1Section111-010120.cln
or Section 105 of the Standard specifications , they will be requested to submit a proposed, Construction Specifications American Institute of Steel Constructors (AISC) Quality Certification Program, Fabricators American Welding Society QC1:2007 Standard for AWS (AWS) Certification of Welding, ) Standard Specification for Road and Bridge Construction Materials Manual Volume I – Chapter 11.1, (NACE) NIICAP Auditing Standard: AS-1 Program for Accreditation of Field and Shop Coatings
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2020/january-2020/materials-manual/section111-010120-cln.pdf?sfvrsn=81421500_4110-200
: REVISION LAST of STANDARD PLANS FY 2024-25 SHEET INDEX 3 1 110-200 MAILBOXES 11/01/17 GENERAL, , for identification letters and numbers. in accordance with this standard; erection; adjustments to suit, specifications of the Domestics Mail Manual of the U. S. Postal Service; The Contractor shall apply box, : REVISION LAST of STANDARD PLANS FY 2024-25 SHEET INDEX 3 2 110-200 MAILBOXES 11/01/17, V I S I O N DESCRIPTION: REVISION LAST of STANDARD PLANS FY 2024-25 SHEET INDEX 3 3
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/idx/110-200.pdf?sfvrsn=615416d5_1425-055
: REVISION LAST of STANDARD PLANS FY 2024-25 SHEET INDEX Type B Fence (See Index 550-002) Steel Grate, or Type A plain installed in accordance with Specifications 416 and 937. Nuts are 8. Anchor Bolts, V I S I O N DESCRIPTION: REVISION LAST of STANDARD PLANS FY 2024-25 SHEET INDEX NOTES, : REVISION LAST of STANDARD PLANS FY 2024-25 SHEET INDEX NOTE: Horizontal Wall Reinforcing Schedules, LAST of STANDARD PLANS FY 2024-25 SHEET INDEX STEEL WEIGHT LENGTH BILL OF STEEL No. REQD
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/idx/425-055.pdf?sfvrsn=c5849432_1110-200
: REVISION LAST of STANDARD PLANS FY 2025-26 SHEET INDEX 3 1 110-200 MAILBOXES 11/01/17 GENERAL, , for identification letters and numbers. in accordance with this standard; erection; adjustments to suit, specifications of the Domestics Mail Manual of the U. S. Postal Service; The Contractor shall apply box, : REVISION LAST of STANDARD PLANS FY 2025-26 SHEET INDEX 3 2 110-200 MAILBOXES 11/01/17, V I S I O N DESCRIPTION: REVISION LAST of STANDARD PLANS FY 2025-26 SHEET INDEX 3 3
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/idx/110-200.pdf?sfvrsn=696ebaa0_1425-055
: REVISION LAST of STANDARD PLANS FY 2025-26 SHEET INDEX Type B Fence (See Index 550-002) Steel, or Type A plain installed in accordance with Specifications 416 and 937. Nuts are 8. Anchor Bolts, R E V I S I O N DESCRIPTION: REVISION LAST of STANDARD PLANS FY 2025-26 SHEET INDEX, DESCRIPTION: REVISION LAST of STANDARD PLANS FY 2025-26 SHEET INDEX NOTE: Horizontal Wall Reinforcing, DESCRIPTION: REVISION LAST of STANDARD PLANS FY 2025-26 SHEET INDEX STEEL WEIGHT LENGTH BILL OF STEEL
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/idx/425-055.pdf?sfvrsn=827703d8_1