9037 search results for test

GL-All-FY1415

Proctor tests with a minimum frequency of one test per soil type [Spec. 125-9] 26. If Density tests, equipment used on this project? 120-10.1.1 9. Is the CEI ensuring that all sampling and testing requirements are met and enforcing the requirement that all samples and test are taken randomly? Does the field test verify this? [Spec 120-10] 10. Does the CEI have an appropriate process to ensure that the correct proctor is used when density tests results are evaluated for material acceptance

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/construction/constadm/guidelist/inspectguidelist/fy1415/gl-all-fy1415.pdf?sfvrsn=f366f8e5_0

1050404-MM9.2VII.resp

"unsatisfactory results", is this data from a single a compressive strength test, a series of strength tests, : (11-21-16) 1. MM 9.2VII. Section 9.2.7 Design Mixes (7) Slump loss test data with an elapsed time, will require a new slump loss test. Assuming the mix design contained the same class of fly ash, loss test. Response: Statement added at the request of the concrete materials technical advisory

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2017/july-2017/review/comments-responses/1050404-mm9.2vii.resp.pdf?sfvrsn=e042e5fa_0

SS9940000

. Evaluation of test samples shall be field tested in accordance with FM 5-571 for each color, with their approved usage. Samples shall be taken in accordance with the Department’s Sampling, Testing, l b e t e s t e d i n a c c o r d a nce with ASTM D4956 and the Florida Test Method, acceptance will be based on tests and verification in accordance with this Specification, FM 5-571, , Testing and Reporting Guide Schedule

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2008/files/ss9940000050ee83915bf4d5aa4b9f6d31040fe22.pdf?sfvrsn=18b22cc3_0

SS9940000

D4956. Evaluation of test samples shall be field tested in accordance with FM 5-571 for each color, shall be taken in accordance with the Department’s Sampling, Testing and Reporting Guide Schedule, o r d a nce with ASTM D4956 and the Florida Test Method for retroreflective and nonreflective, product. Final acceptance will be based on tests and verification in accordance, with the Department’s Sampling, Testing and Reporting Guide Schedule. affect the intended sign use. The process inks

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2009/files/ss9940000.pdf?sfvrsn=3082bf4a_0

SS9940000

. Evaluation of test samples shall be field tested in accordance with FM 5-571 for each color, with their approved usage. Samples shall be taken in accordance with the Department’s Sampling, Testing, l b e t e s t e d i n a c c o r d a nce with ASTM D4956 and the Florida Test Method, acceptance will be based on tests and verification in accordance with this Specification, FM 5-571, , Testing and Reporting Guide Schedule

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2008/files/ss9940000.pdf?sfvrsn=ce39db38_0

9210200.origind

, and the silo numbers where the cement is stored. The mill test report must identify that there is limestone in the cement, if limestone is included. An acceptable mill test report is found in the appendix, for plan approval. In addition to the QC Plan, the supplier must submit test reports from an approved, to these Specifications. Upon initial QC Plan approval and receipt of the cement mill test report, the suppliers, laboratory shall perform one quality control test per day. Submit a copy of the monthly mill test report

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/july-2016/review/internal/9210200.origind.pdf?sfvrsn=21415755_0

7150000.origind

. Determine concrete strength from tests on a minimum of two test cylinders sampled and tested in accordance with ASTM C 31 and ASTM C 39 and verifying test results have been provided to the Engineer. Fill, . Place markers flat on the ground with 1 inch projecting above finished grade. 715-14 Tests of Installation. Upon completion of the work, test the installation to ensure that the installation, working condition. Furnish all labor, materials, and apparatus necessary for making the required tests

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul12/files/7150000.origind.pdf?sfvrsn=46a72800_0

3340104.FHWA

precision values for roadway density being measured by use of the vacuum drying test machine, change, ). An individual test result of a sublot for air voids does not meet the requirements of Table 334-5, consecutive test results within the same LOT for gradation or asphalt binder content do not meet, resuming production, sample and test the material to verify that the changes have corrected, test result differs by more than 0.040 from the mix design Gmm, investigate the causes

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/january-2016/review/fhwa/3340104.fhwa.pdf?sfvrsn=746ab769_0

3340104.origind

to the appropriate testing size, and conditioned and tested as described in 334-5.1.1. In lieu of the 1-1/2 hours, measured by use of the vacuum drying test machine, change reference from "CPF" to "PF”, and change, of the following QC failures occur: 1). An individual test result of a sublot for air voids does, of Table 334-5, 3.) Two consecutive test results within the same LOT for gradation or asphalt, made to correct the problem. After resuming production, sample and test the material to verify

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/january-2016/review/internal/3340104.origind.pdf?sfvrsn=9fd3ec1_0

1050302.comm

of performing the required ASTM test methods for laboratories testing concrete and concrete aggregates, in performance of required QC tests and statistical evaluation of QC test results. Comment- Based, Standard test method for Automated Slump Monitoring System or correlation data shall be provided to relate the standard slump test with this automated slump monitoring system. Response: 3, : 9. Section 9.2.14.1.1.1: Provide applicable ASTM and AASHTO test methods. Response

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul11/files/1050302.comm.pdf?sfvrsn=7640e759_0

5460200IMP

these requirements. Submit a certified test report to the Engineer indicating that the materials meet all, inspection by the Engineer with no further testing required

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/programmanagement/implemented/workbooks/history/jul06/files/5460200imp.pdf?sfvrsn=afd9ef55_0

5460200SS

dimensions by using a self bonding overlay meeting these requirements. Submit a certified test report, with no further testing required

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2006/files/5460200ss.pdf?sfvrsn=afbf9227_0

5460200IMP

these requirements. Submit a certified test report to the Engineer indicating that the materials meet all, inspection by the Engineer with no further testing required

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan06/files/5460200imp.pdf?sfvrsn=3b536b28_0

5460200.impl

dimensions by using a self bonding overlay meeting these requirements. Submit a certified test report, with no further testing required

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan10/files/5460200.impl.pdf?sfvrsn=ea27bc50_0

SS5460200

dimensions by using a self bonding overlay meeting these requirements. Submit a certified test report, with no further testing required

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2010/files/ss5460200.pdf?sfvrsn=8ccf6581_0

1050404-MM92V2.comm

) 9.2.13.2 Qualified Technicians If personnel perform concrete placment, plastic properties test, to cementitious materials ratio, they shall be certified as an ACI Concrete Field Testing

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2019/january-2019/review/comments-responses/1050404-mm92v2.comm.pdf?sfvrsn=e0b4dc21_0

1050404-MM92V2.resp

Technicians If personnel perform concrete placment, plastic properties test, such as slump, materials ratio, they shall be certified as an ACI Concrete Field Testing Technician Grade I Please

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2019/january-2019/review/comments-responses/1050404-mm92v2.resp.pdf?sfvrsn=6d751199_0

5460200SS

dimensions by using a self bonding overlay meeting these requirements. Submit a certified test report, with no further testing required

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2006/january-2006/workbook/5460200ss838a9468ea6e464d98ccfffbee523174.pdf?sfvrsn=d38cc4e5_0

5460200SS

dimensions by using a self bonding overlay meeting these requirements. Submit a certified test report, with no further testing required

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2006/january-2006/workbook/5460200ss.pdf?sfvrsn=2f3e0c5c_0

SS5460200

dimensions by using a self bonding overlay meeting these requirements. Submit a certified test report, with no further testing required

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2010/january-2010/workbook/ss5460200.pdf?sfvrsn=1503e428_0
20 of 9037 results