4676 search results for Standard Specifications

Section111-102714

Florida Department of Transportation Standard Specifications for Road and Bridge Construction (Standard, activities involving high strength bolting as described in Section 460 of the Standard Specifications, 460 of the Florida DOT Standard Specifications and the Department’s Materials Manual. -2- Topic, the following documentation at the fabrication shop:  applicable current standard specifications, supplements,  AWS A3.0, Standard Welding Terms and Definitions  applicable ASTM or AASHTO specifications

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/july-2014/materials-manual/section111-102714.pdf?sfvrsn=813e6eaa_1

CM-700-05 Dynamic Message Sign

of Section 995 of the FDOT Standard Specifications for Road and Bridge Construction and all implemented, of the letter or symbol. FORMDROPDOWN Provide product literature, specifications, user manual, (AASHTO) LRFD (Load and Resistance Factor Design) Specifications for Structural Supports for Highway, , and inspected in accordance with the requirements of the current American National Standard Institute/American, of the sign housing in accordance with the Standard Plans. These structural members run parallel

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/traffic/traf_sys/compliance-matrices-2022/cm-700-05-dynamic-message-sign.docx?sfvrsn=a53358c8_1

1-13WorkbookFINAL

of the Florida Department of Transportation Standard Specifications is revised as follows: DRAFT January, Control Signals and Devices (MSTCSD) and Standard Specifications for Road and Bridge Construction, dates. To incorporate current standard warranty language for consistency with other specifications, . To incorporate current standard warranty language for consistency with other specifications, to clarify,  January 2013 Workbook.....1 Revised 9-6-12 FLORIDA DEPARTMENT OF TRANSPORTATION STANDARD

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2013/january-2013/workbook/1-13workbookfinal.pdf?sfvrsn=78a00731_0

Agency Term Contracts - Printing of Educational Materials

Standard Packaging Quantity Min. Order Qty. 1,000 5,000 10,000 50,000 100,000 150,000 200,000, to School Program Item No. Description Estimated Quantities Avg. Cost Per Unit Standard Packaging, of the vendor. Contract No. CR13984 10 13) PRODUCT REQUIREMENTS/SPECIFICATIONS Items furnished shall be standard products of the manufacturer or their suppliers, shall be new, unused, clean, and free, in normal intended use. Any deviation from specifications indicated herein must be clearly pointed out

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/procurement/files_agency_term_contracts/9100---contract-document.pdf?sfvrsn=331de585_8

4620702-724FHWA

as per manufacturer’s current standard technical specifications. Spray application is preferred, Tallahassee, Florida 32312 Re: State Specifications Office Section: 462 Proposed Specification, State Specifications Engineer DS/dh Attachment cc: Florida Transportation Builders' Assoc, , place filler inlets, outlets or ports in the following positions and those shown in Standard Plans, the following at anchorages as shown on Standard Plans, Index 462-002: a. Temporary drain holes at the bottom

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/fhwa/4620702-724fhwa.pdf?sfvrsn=23de2b5_1

Chapter5s14Redline

./ft 3 ,Standard Plans will be paid per Specifications SectionSpecification 530-4.1. Delivery (1, , 2023TBD Field Records and Contractor's Certifications 5.14-2 (A) Types of Field Records (1) Standard, over standard bound field books, since it results in savings to the Department and it can, (1) Identify the front cover of each Standard Field Book used by including the Federal Aid, in (A) aboverequired on the cover of the Standard Field Book at the top of each form used. It is recommended

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/manuals/cpam/newhistory/chapter5s14redline.pdf?sfvrsn=3734a131_5

2023FloridaGreenbookRulemaking

Traffic Operations FDOT – Central Office Richard Stepp, P.E. Standard Plans Engineer FDOT, are applied. For all projects, there may be practical reasons a certain standard is not met. A process

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/floridagreenbook/2023/2023floridagreenbookrulemaking.pdf?sfvrsn=b48a7760_4

2023FloridaGreenbookRulemakingDraftAWatermark

Richard Stepp, P.E. Standard Plans Engineer FDOT - Central Office Benjamin J. Gerrell, P.E. Quality, are applied. For all projects, there may be practical reasons a certain standard is not met

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/floridagreenbook/2023floridagreenbookrulemakingdraftawatermark.pdf?sfvrsn=22e1ea95_9

REACT350 - NCHRP350 - NARROW (36) - Assembly Manual

specifications for new concrete pads can be found on the standard drawings. Asphalt Anchoring, of the REACT 350 ® Narrow system. These instructions are for standard assemblies specified, , or repair would require a deviation from standard assembly parameters, contact the appropriate highway, , and specifications in this Manual are based on the latest REACT 350 ® Narrow system information available, in conjunction with the assembly of the REACT 350 ® Narrow system and are for standard assemblies only

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/maintenance/rdw/ispe/crash-cushion/react350---nchrp350---narrow-(36)---assembly-manual.pdf?sfvrsn=8538b8c0_1

1-17WorkbookFINAL

OF TRANSPORTATION STANDARD SPECIFICATIONS for ROAD and BRIDGE CONSTRUCTION JANUARY 2017 WORKBOOK Effective, Standard Specifications is revised as follows: January 2017 Workbook…..2 8/25/2016 10:16 AM, and 3-7. SP0030200 When necessary to change standard “Award and Execution”. *Contracts Office, DEVELOPMENTAL SPECIFICATIONS SPY000008 When called for January 2017 Workbook…..16 8/25/2016 10:16 AM SUPPLEMENTAL SPECIFICATIONS SS0000001 USAGE NOTE REMARKS 003 AWARD AND EXECUTION OF CONTRACT

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2017/january-2017/workbook/1-17workbookfinal.pdf?sfvrsn=f23287be_0

1-17WorkbookREDLINE

AS OF 7-2568-3-168-5-168-15-168-16-168-18-168-23- 16 FLORIDA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS for ROAD and BRIDGE, of the Florida Department of Transportation Standard Specifications is revised as follows: January, . SP0030200 When necessary to change standard “Award and Execution”. *Contracts Office must approve, requested by the DDE. January 2017 Workbook…..15 8/25/2016 10:14 AM DEVELOPMENTAL SPECIFICATIONS, SPECIFICATIONS SS0000001 USAGE NOTE REMARKS 003 AWARD AND EXECUTION OF CONTRACT. (REV6-21-16) (FA6-23-16

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2017/january-2017/workbook/1-17workbookredline.pdf?sfvrsn=aae5749c_0

4320000.review

Davis, State Estimates Office, Maintenance Distribution List CC: Dan Hurtado, State Specifications, Office FROM: FrancesThomas, Specifications Development Specialist SUBJECT: ProposedSpecification, . 430-93-2.1 Inspection and Video: Comply with OSHA Confined Space Standard, 20 CFR Part 1910.146., . ProvideahighqualityDVDinaMPEG2format video in color with a standard resolution of 720 x 480. Include

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2017/january-2017/maintenance/review-package/4320000-review.pdf?sfvrsn=121b7489_1

3460000comm

be defined in the standard specifications. Response: ******************************************************************************, , and the fourth paragraph of 346-10.2 be included. 346-10.1 General: For standard molded and cured, . The specifications seem to remove the contractors ability to know what the initial slump is and how much

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2020/january-2020/review/comments-responses/3460000comm.pdf?sfvrsn=566747d5_2

2000702-722FHWA

Specifications Office Section: 200 Proposed Specification: 2000702 Rock Base. Dear Mr. Nguyen: We, Daniel Strickland, P.E. State Specifications Engineer DS/ra Attachment cc: Florida Transportation, equipment. Traffic control is to be provided in accordance with the standard maintenance of traffic, . Traffic control is to be provided in accordance with the standard maintenance of traffic

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/fhwa/2000702-722fhwa.pdf?sfvrsn=32da2670_2

6530202.FHWA

: State Specifications Office Section: 653 Proposed Specification: 6530202 Pedestrian Signal, on file Dan Hurtado, P.E. State Specifications Engineer DH/dt Attachment cc: Florida, be powder-coat painted black in accordance with Military Standard MIL-PRF-24712A or AAMA-2603-02, in accordance with Military Standard MIL-PRF-24712A or AAMA-2603-02 with a reflectance value

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2019/january-2019/review/fhwa/6530202.fhwa.pdf?sfvrsn=86c50bfa_0

6530202.FHWA2

: State Specifications Office Section: 653 Proposed Specification: 6530202 Pedestrian Signal, Hurtado, P.E. State Specifications Engineer DH/dt Attachment cc: Florida Transportation Builders, -coat painted black in accordance with Military Standard MIL-PRF-24712A or AAMA-2603-02, metal housings and visors must be powder-coat painted black in accordance with Military Standard MIL

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2019/january-2019/review/fhwa/6530202.fhwa2.pdf?sfvrsn=b439ad29_0

9300503.FHWA

: State Specifications Office Section: 930 Proposed Specification: 9300503 Materials, on file Dan Hurtado, P.E. State Specifications Engineer DH/dt Attachment cc: Florida, as determined by the specified standard test methods. If extended, materials shall meet, the physical properties stated in Table 4 as determined by the specified standard test methods

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/july-2018/review/fhwa/9300503.fhwa.pdf?sfvrsn=6b55f6bd_0

1600000.resp

with tolerances. The Department is already holding the contractor to a tighter standard so what, suggest completing the criteria for test AASHTO M145 as follows: Symbol= S (per Standard Plans Index, Mixing Depth Witness. Also section 200 of the specifications for rock base the verification frequency, in the specifications. No change made. 2. 160-2.2.2 – Is testing required if material is coming from

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/july-2018/review/comments-responses/1600000.resp.pdf?sfvrsn=c7529d58_2

4550707.FHWA

: State Specifications Office Section: 455 Proposed Specification: 4550707 Structures Foundations, at 414-4130. Sincerely, Signature on file Dan Hurtado, P.E. State Specifications Engineer DH/dt, in the Standard Indexes or using proprietary splices which are listed on the Department’s Approved Product, with the dowel splice method contained in the Standard Indexes or using proprietary splices which are listed

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/january-2018/review/fhwa/4550707.fhwa.pdf?sfvrsn=20352295_0

4510200.origind

 ORIGINATION FORM Proposed Revisions to the Specifications (Please provide all information - incomplete forms will be returned) Contact the State Specifications Office for assistance in completing this form. Daniel Scheer 850-414-4130 daniel.scheer@dot.state.fl.us Debbie Toole 850-414-4114, /Subarticles: Telephone: email: Will the proposed revision involve Design Standard Index changes, as defined by the specified standard. 23.TendonBondLength

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2017/january-2017/review/internal/4510200.origind.pdf?sfvrsn=918ec69d_0
20 of 4676 results