9006 search results for test

5560102.FHWA

by the owner. If the owner does not require pressure testing, the Engineer may require at least one test, test required (2) Dimensional tolerances only Unless otherwise tested and approved, one test. 556-4.3.2 Drainage Application Testing (Under Pavement): When under pavement (including, (RTRP) ASTM D2996 or ASTM D2997 ASTM D2996 or ASTM D2997 (1) No hydrostatic test required (2) Dimensional tolerances only Unless otherwise tested and approved by the Department, only use

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/january-2018/review/fhwa/5560102.fhwa.pdf?sfvrsn=bdfb13ce_0

Asphalt-Asphalt Acceptance - Musselman

• Payment based on Contractor’s Q u a l i t y C o ntrol test data that has been validated by the Department • FDOT runs verification tests at a lesser frequency to validate the QC results • Payment, of Transportation QC Te sting at Plant QC randomly tests one per sublot. VT randomly tests one split per lot, • If not….samples go to Resolution testing – District Materials Office Florida Department of Transportation Ve r i f i cation Te sting Sublot 1 Sublot 2 Sublot 3 Sublot 4 LOT = 4 0 0 0 To n s QC tests one

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/training/2025-spring-construction-academy/asphalt-asphalt-acceptance---musselman.pdf?sfvrsn=6006bb8a_1

Asphalt Acceptance Musselman

• Payment based on Contractor’s Q u a l i t y C o ntrol test data that has been validated by the Department • FDOT runs verification tests at a lesser frequency to validate the QC results • Payment, of Transportation QC Te sting at Plant QC randomly tests one per sublot. VT randomly tests one split per, • If not….samples go to Resolution testing – District Materials Office Florida Department of Transportation Ve r i f i cation Te sting Sublot 1 Sublot 2 Sublot 3 Sublot 4 LOT = 4 0 0 0 To n s QC tests

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/training/2025-fall-construction-academy/asphalt-acceptance-musselman.pdf?sfvrsn=a00683b5_1

D3 WP 2025 HPH FAR Ad Confirmation

of the proceeding is made, which record includes the testimony and evidence from which the appeal, that a verbatim record of the proceeding is made, which record includes the testimony and evidence from

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/d3_documents/d3-wp-2025-hph-far-ad.pdf?sfvrsn=17189481_4

QF-671-01-1 ATC 5201 7.7.1-7.10.3 Checklist

are for the Vibration Tests. 1 7.8 (NEMA TS2 2.2.8.2) Test equipment meets the stated requirements. FORMDROPDOWN, frequency has been recorded in accordance with NEMA TS2 Section 2.2.8.3 Item 4, equally divide the test period of 1 hour between the resonant frequencies. The total time of the endurance test is limited,       FORMTEXT       Init.: FORMTEXT       The following criteria are for the Shock (Impact) Tests. 6 7.9 (NEMA TS2 2.2.9.2) Test equipment meets the stated requirements. FORMDROPDOWN Document Review

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/traffic/traf_sys/compliance-matrices-2022/qf-671-01-1-atc-5201-7-7-1-7-10-3-checklist.docx?sfvrsn=56599ceb_1

D9950003.do

 995 DEMOUNTABLESIGNFACEMATERIALS-CERTIFICATION. (REV11-27-00)(FA3-7-01)(1-02) ARTICLE995-3(Page976)isdeletedandthefollowingsubstituted: 995-3Certification. TheContractorshallprovidetheEngineeracertifiedtestreportfrom the manufacturer of the demountable sign face materials confirming that the requirements of this Section are met. The certified test report shall conform to the requirements of Section 6 and include test results for entrance angle, observation angle, specific brightness

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2003/files/d9950003.do.pdf?sfvrsn=dc5c08_0

D9820002.do

 982 COMMERCIALFERTILIZER - CERTIFICATION. (REV11-27-00)(FA3-28-01)(1-02) SECTION982(Page951)isexpandedasfollows: 982-2Certification. TheContractorshallprovidetheEngineeracertifiedtestreportfrom the manufacturer of the commercial fertilizer confirming that the requirements of this Section are met. The certified test report shall conform to the requirements of Section 6 and include test results for total nitrogen, available phosphoric acid, water-soluble potash, and sulfur. Each

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2003/files/d9820002.do.pdf?sfvrsn=24339e05_0

3340102.comm

 3340102 SUPERPAVE ASPHALT CONCRETE COMMENTS FROM INTERNAL/INDUSTRY REVIEW Karen Byram 414-4353 karen.byram@dot.state.fl.us Comments: (5-22-17, Internal) I thought that we were not including test method dates unless the test method was changed and we were still working on the FM. Those dates (-13, -14, 2015, etc.) should be removed. Response: ******************************************************************************

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/january-2018/review/comments-responses/3340102.comm.pdf?sfvrsn=b64ef95e_0

9160203.comm

 9160203 BITUMINOUS MATERIALS COMMENTS FROM INTERNAL/INDUSTRY REVIEW Karen Byram 414-4353 karen.byram@dot.state.fl.us Comments: (5-22-17, Internal) I thought that we were not including test method dates unless the test method was changed and we were still working on the FM. Those dates (-13, -14, 2015, etc.) should be removed. Response: ******************************************************************************

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/january-2018/review/comments-responses/9160203.comm.pdf?sfvrsn=ac7dd7f8_0

9700000.resp

 9700000 MATERIALS FOR RAISED RETROREFLECTIVE PAVEMENT MARKERS AND BITUMINOUS ADHESIVE COMMENTS FROM INTERNAL/INDUSTRY REVIEW Maria Connolly 954-934-1209 maria.connolly@dot.state.fl.us Comments: (11-20-15) 970-1 Retroreflective Pavement Markers (RPM): Suggest changing "The Department will test all retroreflective pavement markers in accordance with FM 5-566." to "The Department will test all RPMs in accordance with FM 5-566." Response: Agree. Change made ******************************************************************************

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/july-2016/review/comments-responses/9700000.resp.pdf?sfvrsn=bc3f57f1_0

Mix Designs

Mix Designs Asphalt Mix Design Part 1 Creating and Initiating the Mix Design Video (17:20) Asphalt Mix Design Part 2 Entering the Test Data Video (12:31) Asphalt Mix Design Part 3 Revising a Mix Design Video (12:30) Concrete Mix Design Part 1 Creating a Mix Design and Entering Test Data Video (28:11) Concrete Mix Design Part 2 Revising an Existing Mix Design Video (28:11)

https://www.fdot.gov/contracts/district-offices/d5/lettings/dist-letting-project-info.shtm/lists/mix-designs/mix-designs

5600000.comm

560-7.5; Per this section salt tests are required after washing & between each coat. Please consider, for new zinc primed steel, that after the initial tests are performed prior to the first coat subsequent tests will be required between coats only if the time between coats exceeds 30 days or some other time at the states discretion. This will reduce the cost of testing. Keep in mind that testing requires not only the personnel and countless tests kits but the equipment to access the area

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul09/files/5600000.comm.pdf?sfvrsn=7b35ea33_0

5600000.comm

560-7.5; Per this section salt tests are required after washing & between each coat. Please consider, for new zinc primed steel, that after the initial tests are performed prior to the first coat subsequent tests will be required between coats only if the time between coats exceeds 30 days or some other time at the states discretion. This will reduce the cost of testing. Keep in mind that testing requires not only the personnel and countless tests kits but the equipment to access the area

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan10/files/5600000.comm.pdf?sfvrsn=db53cb7f_0

fdot-bed65-sum

a testing program to assess the fatigue sensitivity of HRBS connections over intermediate supports, connection using AASHTO LRFD fatigue categories based on test results; and developing a corrosion, bridges for parametric studies. The team developed a detailed fatigue testing plan, focusing, prevention methods. The test plan for fatigue involved different specimen configurations to determine, conditions. Fatigue testing highlighted that welded stiffeners improve the long-term performance

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/research/reports/fdot-bed65-sum.pdf?sfvrsn=1879d9fc_1

3460202.origind

tested in accordance with AASHTO T358. Submit three 4 x 8 inch cylindrical test specimens to the Engineer for resistivity testing before mix design approval. Take the resistivity test specimens from, for the required plastic and hardened property tests. Cure the field trial batch specimens similar to the standard laboratory curing methods. Submit the resistivity test specimens at least 7 calendar days prior to the scheduled 28 day test. The average resistivity of the three cylinders, eight

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2017/july-2017/review/internal/3460202.origind.pdf?sfvrsn=3481fe5e_0

1050511.D01.IMP

Manufacturing Facilities: 105-5.11.1.4.1 Testing Personnel: Ensure the personnel performing plastic property tests have ACI Concrete Field Testing Technician-Grade I certification. Ensure the personnel performing laboratory compressive strength testing have ACI Concrete Laboratory Testing Technician-Grade 1 certification or ACI Concrete Strength Testing Technician certification. 105-5.11.1.4.2: Batch

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan07/files/1050511.d01.imp.pdf?sfvrsn=cd59d678_0

9320100.impl

or discontinuities and without damage to the material. Materials for pavement joints shall be tested according, perpendicular to the side of the sealant showing the defect. At least two test samples in a group of three, perpendicular to the side of the sealant showing the defect. At least two test samples in a group of three, datasheets, performance test reports from an independent laboratory showing the product meets, a manufacturer’s product is tested and approved by the Department using a primer, primer

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan12/files/9320100.impl.pdf?sfvrsn=1b0a904c_0

4551206-722FHWA

performance tests within the costs of temporary sheet piling. Please review and transmit your, wales, anchor bars, dead men, soil anchors, proof tests, performance tests, creep tests, and other, , and including wales, anchor bars, dead men, soil anchors, proof tests, performance tests, creep tests

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/fhwa/4551206-722fhwa.pdf?sfvrsn=39a96868_2

5480206.origind

= 4.5 to 4.99. To document the laboratory testing procedure to be followed when MSE shop drawings, under certain circumstances. Incorporation in the Specification of the current lab testing, MSE walls may be constructed using backfill with a pH as low as 4.5 and to include the testing, of Sections 105 and 120 except as noted within this Section. Have the backfill material tested for every, testing laboratory prior to placement. Provide certification to the Engineer that the results have

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul13/files/5480206.origind.pdf?sfvrsn=e026d348_0

9320100.FHWA

, and meet the following minimum testing requirements: TEST PROPERTY DESCRIPTIONTESTMETHODTYPEV1, Specification with current ASTM Specifications and delete a field test for low modulus silicone, shall be tested according to ASTM D 5329. 932-1.2.2.1 Physical Requirements of Joint Sealants, . At least two test samples in a group of three representing a given sample of sealant shall meet, two test samples in a group of three representing a given sample of sealant shall meet

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan12/files/9320100.fhwa.pdf?sfvrsn=94925b6_0
20 of 9006 results