9191 search results for test
7-20eBook
ASTM American Society for Testing and Materials AWG American Wire Gauge AWPA American Wood, designation, or combination of numbers and letters, designates a specification, test method, or other code, , test methods, or other codes as specified in the current edition at the time of the bid opening, furnished and of the work performed by the Contractor. Laboratory. The official testing laboratory used
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2020/july-2020/ebook/7-20ebook.pdf?sfvrsn=c1f3424e_49480107Orign
been tested at the plant hydrostatically at the specified pressure using test methods in ASTM D, that the pipe joints have been tested at the plant hydrostatically at the specified pressure using test, by citing the soil-tight criteria, (3) Eliminate repetitious references to pipe joint testing, combining, . Test pipe joints at the plant hydrostatically using test methods in ASTM D 3212 [ASTM D 3212M, in the pipe joint, the gasket shall be the sole element relied on to maintain a tight joint. Test
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan07/files/9480107orign.pdf?sfvrsn=c0834ee_06840100-724FHWA
. 684-2.4 Field Acceptance Testing: Develop and submit a field acceptance test FAT plan, field operational tests at device server field sites according to the test procedures stated herein, /TIA-568-B standard. 684-3.4 Field Acceptance Testing: Develop and submit a field acceptance test FAT, with the EIA/TIA-568-B standard. 684-1.4 Field Acceptance Testing: Conduct field acceptance testing, field site according to the approved test plan. Perform the following: 684-2.3 Managed Hub Ethernet
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/fhwa/6840100-724fhwa.pdf?sfvrsn=6361881d_19750900.origind
of the structure. 975-9.2 Material Tests: Meet the following requirements: Additional Laboratory Performance and Tests Test Method Limits Accelerated Weathering AASHTO R-31 No blistering, cracking, rating) 9750900 Jobs with structures Additional Laboratory Performance and Tests Test Method Limits, . In addition, the current specification does not require any graffiti- removal performance based testing, Per Manufacturer’s specifications: 6 months exposure at FDOT test site Complete removal
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul08/files/9750900.origind.pdf?sfvrsn=1ac492cb_09750900Orgin
inspection but not detract from visual impact of the structure. 975-9.2 Material Tests: Meet the following requirements: Additional Laboratory Performance and Tests Test Method Limits Accelerated, Laboratory Performance and Tests Test Method Limits Fluid Resistance ASTM D1308; Paint Thinner, . In addition, the current specification does not require any graffiti- removal performance based testing, and Transportation Officials Regional Testing Program, June 1997. Both of these documents outlined performance
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan07/files/9750900orgin.pdf?sfvrsn=6a9c8b2e_09750900Orgin
inspection but not detract from visual impact of the structure. 975-9.2 Material Tests: Meet the following requirements: Additional Laboratory Performance and Tests Test Method Limits Accelerated, Laboratory Performance and Tests Test Method Limits Fluid Resistance ASTM D1308; Paint Thinner, . In addition, the current specification does not require any graffiti- removal performance based testing, and Transportation Officials Regional Testing Program, June 1997. Both of these documents outlined performance
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul06/files/9750900orgin.pdf?sfvrsn=9946ea3e_09750900orgin
inspection but not detract from visual impact of the structure. 975-9.2 Material Tests: Meet the following requirements: Additional Laboratory Performance and Tests Test Method Limits Accelerated, Laboratory Performance and Tests Test Method Limits Fluid Resistance ASTM D1308; Paint Thinner, . In addition, the current specification does not require any graffiti- removal performance based testing, and Transportation Officials Regional Testing Program, June 1997. Both of these documents outlined performance
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan07/files/9750900orgina24616f4ed3444a5bf454d7497b81b9b.pdf?sfvrsn=936772f3_01-21eBook (signed and sealed)
Society of Mechanical Engineers ASTM American Society for Testing and Materials AWG American, a specification, test method, or other code or recommendation of the particular authority or organization shown. Use standards, specifications, test methods, or other codes as specified in the current, . Laboratory. The official testing laboratory used by the Department. 5 January 2021 Major Item
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2021/january-2021/ebook/1-21ebook-(signed-and-sealed).pdf?sfvrsn=26f29044_21-21eBook
Society of Mechanical Engineers ASTM American Society for Testing and Materials AWG American, a specification, test method, or other code or recommendation of the particular authority or organization shown. Use standards, specifications, test methods, or other codes as specified in the current, . Laboratory. The official testing laboratory used by the Department. 5 January 2021 Major Item
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2021/january-2021/ebook/1-21ebook.pdf?sfvrsn=1c62cb58_2SS9140000
exceeding limits defined by EPA, qualifying tests shall be performed. Test methods, . The maximum allowable test result is 4.7%. Materials that contain hazardous substances or contaminates
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2012/files/ss9140000.pdf?sfvrsn=b9241cad_0SS9140000
exceeding limits defined by EPA, qualifying tests shall be performed. Test methods, . The maximum allowable test result is 4.7%. Materials that contain hazardous substances or contaminates
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2012/january-2012/workbook/ss9140000.pdf?sfvrsn=b4d3978_02011_Load_Rating_Manual_01-01-11
Structures . 7-10 8 Lo ad Testin g o f Bridges, Load Test Candidate ........................................................................................... 8-2 8.3 Load Test Reports, , recognized formulae, computer programs, or load tests. Such judgment should be used to evaluate, and Engineering Judgment. Load tests may be used as load rating provided that all the trucks
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/maintenance/maintenance/str/lr/2011_load_rating_manual_01-01-11.pdf?sfvrsn=1d23100b_09380602.origind
by the Post-Tensioning Institute. Report the percent bleed for the grout tested. Test grout at the specified pressure of 100 psi. An acceptable test will result in no bleed water (0.0 percent)., to the Specification for Grouting of Post-Tensioned Structures. The Schupak Pressure Bleed Test Procedure has, : The cross reference to the Schupak Pressure Bleed Test Procedure in 938-6.2 has been revised from "Appendix, the Schupack Pressure Bleed Test Procedure for Cement Grouts for Post-Tensioned Structures as outlined
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/january-2014/review/internal/9380602.origind.pdf?sfvrsn=b73e9e79_025thAACMinutes
to go by as early as July 2002. 13. P e rformance Testing – Do we have a simple test to measure, as a “performance/strength test” but relating it to performance as well as the testing variability has, in the support of research in this area, and some potential tests have been identified. Test methods, in regards to rutting on some test projects and in accelerated load testing at the State Materials, of last year. During a one-year testing period, we have the test results of four projects (two from
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/construction/publications/meetingminutes/asphalt/asphaltconf/25thaacminutes.pdf?sfvrsn=da4df165_09480000.origind
copies of mill analysis covering chemical and physical test results. 948-1.5 Underdrain, Meet the following requirements: Table 1 Stress Crack Resistance of Pipes Pipe Location Test Method Test Conditions Requirement 9480000 All Jobs Table 1 Pipe Liner FM 5-572, Procedure A 10, . Junction FM 5-572, Procedure B and FM 5-573 Full Test (2)(,3) : Test at 3 temperature/stress combinations: 176°F at 650 psi 176°F at 450 psi 158°F at 650 psi; 5 replicates at each test
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul12/files/9480000.origind.pdf?sfvrsn=6884140e_09480000-721impl
to the Engineer the mill analysis covering chemical and physical test results. 948-1.5 Underdrain: PVC, for reworked plastic. Table 948-1 Stress Crack Resistance of Pipes Pipe Location Test Method Test, , Procedure B and FM 5-573 Full Test (2)(3) Test at 3 temperature/stress combinations: 176°F at 650 psi 176°F at 450 psi 158°F at 650 psi; 5 replicates at each test condition Determine failure time, ) The tests for each condition can be terminated at duration equal to or greater than the following
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2021/july-2021/review/implemented/9480000-721impl.pdf?sfvrsn=fc67aa88_29480000.origind
to the Engineer the mill analysis covering chemical and physical test results. 948-1.5 Underdrain, Test Method Test Conditions Requirement 9480000 All Jobs Table 948-1 Pipe Liner FM 5-572, than 17.0 hours. Junction FM 5-572, Procedure B and FM 5-573 Full Test (2)(3) Test at 3, at each test condition Determine failure time at 500 psi at 73.4°F ≥ 100 years (95% lower confidence) using 15 failure time values (4) The tests for each condition can be terminated
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/january-2018/review/internal/9480000.origind.pdf?sfvrsn=7aba3cf7_09480000.FHWA
covering chemical and physical test results. 948-1.5 Underdrain: PVC pipe for use as underdrain, of Pipes Pipe Location Test Method Test Conditions Requirement Pipe Liner FM 5-572, Procedure, hours. Junction FM 5-572, Procedure B and FM 5-573 Full Test (2)(3) Test at 3 temperature/stress combinations: 176°F at 650 psi 176°F at 450 psi 158°F at 650 psi; 5 replicates at each test, 15 failure time values (4) The tests for each condition can be terminated at duration equal
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/january-2018/review/fhwa/9480000.fhwa.pdf?sfvrsn=e60fa60b_09480000.origind
test results. 948-1.5 Underdrain: PVC pipe for use as underdrain shall conform to the requirements, : Table 948 -1 Stress Crack Resistance of Pipes Pipe Location Test Method Test Conditions Requirement, , Procedure B and FM 5-573 Full Test Test at 3 temperature/stress combinations: (2)(3) 176°F at 650 psi 176°F at 450 psi 158°F at 650 psi; 5 replicates at each test condition Determine failure, The tests for each condition can be terminated at duration equal to or greater than the following
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2015/january-2015/review/internal/9480000.origind.pdf?sfvrsn=4e0dc3e8_09480000.FHWA
of mill analysis covering chemical and physical test results. 948-1.5 Underdrain: PVC pipe for use, Pipe Location Test Method Test Conditions Requirement 9480000.D01 All Jobs Table 948 -1 Pipe Liner, shall be less than 17.0 hours. Junction FM 5-572, Procedure B and FM 5-573 Full Test Test at 3, replicates at each test condition Determine failure time at 500 psi at 73.4°F ≥ 100 years (95% lower confidence) using 15 failure time values The tests for each condition can be terminated
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2015/january-2015/review/fhwa/9480000.fhwa.pdf?sfvrsn=cdf23697_0