4643 search results for fla
9160000.origind
)) Flash Point, AASHTO T 48-06 (20102015) Cleveland Open Cup Minimum 450ºF Rotational Viscosity
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/july-2016/review/internal/9160000.origind.pdf?sfvrsn=78a70e8f_09160000.FHWA
in Trichloroethylene Minimum 99.0% (Not applicable for PG 76-22 (ARB)) Flash Point, AASHTO T 48-06
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/july-2016/review/fhwa/9160000.fhwa.pdf?sfvrsn=81171748_09710000SS
* Shore Durometer, A2 40 75 Impact Resistance ASTM D 256, Method A 1.0 N·m - Flash Point ASTM D, - Flash Point ASTM D 92 475ºF [245ºC] - *The durometer and panel shall be at 110ºF [45ºC] with a 4.4 lb, * Shore Durometer, A2 65 - Impact Resistance ASTM D 256, Method A 10 inch pound [1.0 N·m] - Flash, , A2 45 - Impact Resistance ASTM D 256, Method A 10 in-lb [1.0 N·m] - Flash Point ASTM D 92 475ºF
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2006/january-2006/workbook/9710000ss.pdf?sfvrsn=372070c8_09710000SS
* Shore Durometer, A2 40 75 Impact Resistance ASTM D 256, Method A 1.0 N·m - Flash Point ASTM D, - Flash Point ASTM D 92 475ºF [245ºC] - *The durometer and panel shall be at 110ºF [45ºC] with a 4.4 lb, * Shore Durometer, A2 65 - Impact Resistance ASTM D 256, Method A 10 inch pound [1.0 N·m] - Flash, , A2 45 - Impact Resistance ASTM D 256, Method A 10 in-lb [1.0 N·m] - Flash Point ASTM D 92 475ºF
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2006/january-2006/workbook/9710000ss417312f3c76e41e7b042e9ce33967fa3.pdf?sfvrsn=8d6bd458_09160000.origind
in Trichloroethylene Minimum 99.0% (Not applicable for PG 76-22 (ARB)) 9160000 All Jobs Flash Point
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/january-2016/review/internal/9160000.origind.pdf?sfvrsn=44a268f5_09160000.FHWA
% (Not applicable for PG 76-22 (ARB)) 9160000 All Jobs Flash Point, AASHTO T48-06 (2010
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/january-2016/review/fhwa/9160000.fhwa.pdf?sfvrsn=ed64908c_09160300-723origind
99.0% (Not applicable for PG 76-22 (ARB)) Flash Point, AASHTO T 48-18 Cleveland Open Cup
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/internal/9160300-723origind.pdf?sfvrsn=644524cb_1PublicHearing_MIAMI_DADE COUNTY_Summary
$2,250,000 $2,250,000 $2,250,000 $2,250,000 $2,250,000 420452-2 - SOUTH FLA COMMUTER SERVICES IN MIAMI-DADE, $800,000 $800,000 $800,000 $800,000 420462-9 - SOUTH FLA COMMUTER SERVICES IN MIAMI-DADE I-95, $138,029 $138,029 $138,029 $138,029 $138,029 422242-2 - SOUTH FLA COMMUTER SERVICES IN MIAMI-DADE, $953,334 $2,672,224 418423-6 - SR 826/PALMETTO EXPY FROM SR 968/W FLAGLER ST TO S OF NW 154 STREET Type
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/d6_documents/publichearing_miami_dade-county_summary.pdf?sfvrsn=c801358d_1Tom Deines TNT Consulting Professional Resume _DRB 10 4 21
Training Traffic Flagger certification Excavation Competent Person SAFETY CONSULTANT, ], ODOT FLAGGER TRAINING INSTRUCTOR ACI: CONCRETE QUALITY CONTROL TECHNICIAN (QCT) [Previous
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/constadm/drb/resume/tom-deines-tnt-consulting-professional-resume-_drb-10-4-21.pdf?sfvrsn=b89ae12f_51020602.FHWA
application and installation. Vendor drawings for Category III devices and automated flagger assistance, and installation. Vendor drawings for Category III devices and automated flagger assistance devices (AFADs
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/january-2018/review/fhwa/1020602.fhwa.pdf?sfvrsn=91310a9c_0E58F9BidTabs
160,001.92000 160,001.92 153,000.00000 153,000.00 0015 0102 5 PEDESTRIAN ESCORT/FLAGGER 192.000 HR, 381,950.00000 381,950.00 0015 0102 5 PEDESTRIAN ESCORT/FLAGGER 192.000 HR 50.00000 9,600.00 45.00000
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d5/bid-tabs/2025/dec02/e58f9bidtabs.pdf?sfvrsn=d7902a3a_1E58F8BidTabs
137,000.00 98,850.00000 98,850.00 0015 0102 5 PEDESTRIAN ESCORT/FLAGGER 96.000 HR 65.00000 6,240.00, 225,471.00 0015 0102 5 PEDESTRIAN ESCORT/FLAGGER 96.000 HR 50.00000 4,800.00 1,000.00000 96,000.00
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d5/bid-tabs/2025/dec02/e58f8bidtabs.pdf?sfvrsn=e7bc7510_1SPM7000106-723origind
head bolts on the sign surface using stainless steel flat head machine screws with nuts and lock washers to give a flat surface for the overlay panel. Install the overlay panels starting at the edge, and Standard Plans, Index 700-120. 700-4.2 Materials: Use flashing beacons, highlighted signs, : The Contract unit price per each for sign beacon will consist of the flashing beacons, cabinet
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/maintenance/review-package/spm7000106-723origind.pdf?sfvrsn=bca0e302_2Pt2Ch16_073124_clean
, Fla. Const. , entrusted to “exercise the regulatory and executive powers of the state with respect
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/environment/pubs/pdeman/2024/pt2ch16_073124_clean.pdf?sfvrsn=284cd6c8_1E4X30
0654- 2- 22 MIDBLOCK CROSSWALK: RECTANGULAR RAPID FLASHING BEACON, FURNISH & INSTALL- SOLAR, FLASHING BEACON, REMOVE COMPLETE SIGN ASSEMBLY AS 8.000 0665- 1- 11 PEDESTRIAN DETECTOR, FURNISH
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d4/lettings/2024/dec06/e4x30.pdf?sfvrsn=9964b874_1E1X83
VEHICULAR TRAFFIC SIGNAL, INSTALL AS 5.000 0654- 2- 21 MIDBLOCK CROSSWALK: RECTANGULAR RAPID FLASHING, MIDBLOCK CROSSWALK: RECTANGULAR RAPID FLASHING BEACON, FURNISH & INSTALL- SOLAR, COMPLETE SIGN ASSEMBLY
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d1/lettings/2025/mar20/e1x83.pdf?sfvrsn=8539068e_1SP0080410redline
1 PROSECUTION AND PROGRESS - EQUIPMENT. (REV 9-24-15) (1-16) ARTICLE 8-4 is expanded by the addition of the following new Subarticle: 8-4.10 Equipment: Equip vehicles and mobile equipment used on the project with a minimum of one class 2 amber or white flashing light that meets the Society of Automotive Engineers recommended practice SAE J845 and SAE J1318. The Engineer may require a white flashing light meeting the above requirements when conditions reduce the effectiveness of amber
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/january-2016/maintenance/review-package/sp0080410redline.pdf?sfvrsn=74392431_0SP0080410
1 PROSECUTION AND PROGRESS - EQUIPMENT. (REV 9-24-15) (1-16) ARTICLE 8-4 is expanded by the addition of the following new Subarticle: 8-4.10 Equipment: Equip vehicles and mobile equipment used on the project with a minimum of one class 2 amber or white flashing light that meets the Society of Automotive Engineers recommended practice SAE J845 and SAE J1318. The Engineer may require a white flashing light meeting the above requirements when conditions reduce the effectiveness of amber
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/january-2016/maintenance/implemented/sp0080410.pdf?sfvrsn=68c4fe9_1Z4148
- POLE/PEDESTAL TO REMAIN AS 5.000 0654- 2- 28 MIDBLOCK CROSSWALK: REC RAPID FLASHING BEACON, CROSSWALK: RECTANGULAR RAPID FLASHING BEACON, REMOVE COMPLETE SIGN ASSEMBLY AS 5.000 0660- 3- 11
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d4/lettings/2025/jun12/z4148.pdf?sfvrsn=38b1a71a_1E1Y13
: RECTANGULAR RAPID FLASHING BEACON, FURNISH & INSTALL- SOLAR, COMPLETE SIGN ASSY- SINGLE DIRECTION AS 2.000 0654- 2- 22 MIDBLOCK CROSSWALK: RECTANGULAR RAPID FLASHING BEACON, FURNISH & INSTALL- SOLAR
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d1/lettings/2025/oct16/e1y13.pdf?sfvrsn=6599969a_1