8978 search results for test

Final Grouting Training Manual 7-30-02

time based on ASTM C939 standard and modified tests. The efflux test essentially measures, until this test has been passed. The ASTM C939 tests were conceived to ensure the proper consistency, testing. Figure 14, Wick induced bleed tests 21 3) Density Another viable measure to be used, ............................................................. 15 A. Leak Testing, .................................................................................................................................... 15 C. Fluidity, Temperature and Bleed Testing

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/training/selfstudy/tutorial/final-grouting-training-manual-7-30-02.pdf?sfvrsn=73e9fe50_0

2000702-722FHWA

sampling and testing at a minimum frequency listed in the table below. The Engineer will perform Verification sampling and tests at a minimum frequency listed in the table below. Table 200-1, Systems Test Name Quality Control Verification Modified Proctor Maximum Density One per eight, 200-2 Shoulder-Only, Shared Use Path and Sidewalk Construction Test Name Quality Control, substituted: 200-7.3.1.2 Depth and Surface Testing Requirements: Notify the Engineer a minimum of 24

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/fhwa/2000702-722fhwa.pdf?sfvrsn=32da2670_2

GL-6 Base (2017-2018) clean

6 inches has the approval of the Engineer based on results of a test section constructed using, ] 17. Ensure density tests for the lower course are taken and passed prior to spreading material, sampling and testing are performed at the minimum frequency required. [Spec. 200-7] 20. Enforce the requirement that all required density test results are documented on current forms provided, that the Pit Proctor approval, IV testing frequency and comparison are met in accordance

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/construction/constadm/guidelist/inspectguidelist/fy1718/gl-6-base-(2017-2018)-clean.pdf?sfvrsn=c2f01700_0

GL-6 Base (2016-2017) 7-12-16 clean

has the approval of the Engineer based on results of a test section constructed using, density tests for the lower course are taken and passed prior to spreading material for the top course, and testing are performed at the minimum frequency required. [Spec. 200-7] 20.Enforce the requirement that all required density test results are documented on current forms provided by the Department, approval, IV testing frequency and comparison are met in accordance with the Specs. [Spec. 200-7

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/construction/constadm/guidelist/inspectguidelist/fy1617/gl-6-base-(2016-2017)-7-12-16-clean.pdf?sfvrsn=9b46d675_0

2000702.origind

to reduce the frequency of Verification Testing for density on Streamline Contracts, ) is deleted and the following substituted: 200-7.2.2 Frequency: Conduct QC sampling and testing at a minimum frequency listed in the table below. The Engineer will perform Verification sampling and tests, Lots, Concrete Box Culverts and Retaining Wall Systems Test Name QualityControl Verification, Witness Shoulder-Only, Bike/Shared Use Path and Sidewalk Construction Test Name QualityControl

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul10/files/2000702.origind.pdf?sfvrsn=d8c7d665_0

GL-6 Base (2018-2019) clean

6 inches has the approval of the Engineer based on results of a test section constructed using, ] 17. Ensure density tests for the lower course are taken and passed prior to spreading material, sampling and testing are performed at the minimum frequency required. [Spec. 200-7] 20. Enforce the requirement that all required density test results are documented on current forms provided, that the Pit Proctor approval, IV testing frequency and comparison are met in accordance

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/construction/constadm/guidelist/inspectguidelist/fy1819/gl-6-base-(2018-2019)-clean.pdf?sfvrsn=9d34e407_0

section62-061312

) American Society for Testing and Materials (ASTM) Standard Test Methods and Specifications, the quality control test methods, inspections, and minimum frequency of tests that are used, , hydrostatic testing equipment. (I) Joint forming equipment and gaskets, and Pipe test results. (J) LOT, (AASHTO), Part I Specifications, and Part II Tests, Washington, D.C. (E) Approved Product List (APL), Florida Department of Transportation. (F) Field sampling and Testing Manual, Florida Department

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2012/january-2012/materials-manual/section62-061312.pdf?sfvrsn=23b04fad_1

1600000.resp

and increasing the distance/total number of tests - how does one handle a project that is built, to to be a push toward larger Lots and longer consecutive distances before reduced testing is an option. My, to reduce testing requirements. Traffic construction sections are not expanded, comments for your consideration. 1. Under 160-7.2.4, add Soil Classification test at the same frequency of LBR test. 160-2, last paragraph – 2. the reference to Section 290 is a bad reference as 290

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul07/files/1600000.resp.pdf?sfvrsn=746159e7_0

fm5-572

Gainesville, Florida 32609 September 10, 2025 FM 5-572 Page 1 of 17 Florida Method of Test for Determining Stress Crack Resistance of HDPE Corrugated Pipes Designation: FM 5-572 1. SCOPE This test method subjects a dumbbell-shaped, notched or un-notched test-specimen to a constant ligament stress, % IGEPAL solution or water at an elevated temperature. The test consists of three procedures to assess, . This test method measures the failure time associated with a given test specimen at a constant

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/materials/administration/resources/library/publications/fstm/methods/fm5-572.pdf?sfvrsn=7c1aea49_3

SS9480000

copies of mill analysis covering chemical and physical test results. 948-1.5 Underdrain: PVC pipe, the following requirements: Table 1 Stress Crack Resistance of Pipes Pipe Location Test Method Test, , Procedure B and FM 5-573 Full Test (2)(3) Test at 3 temperature/stress combinations: 176°F at 650 psi 176°F at 450 psi 158°F at 650 psi; 5 replicates at each test condition Determine failure, ) The tests for each condition can be terminated at duration equal to or greater than

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2012/files/ss9480000.pdf?sfvrsn=6847db9a_0

9480000.impl

submit to the Engineer the mill analysis covering chemical and physical test results. 948-1.5, Pipe Location Test Method Test Conditions Requirement Pipe Liner FM 5-572, Procedure A 10, . Junction FM 5-572, Procedure B and FM 5-573 Full Test (2)(3) Test at 3 temperature/stress combinations: 176°F at 650 psi 176°F at 450 psi 158°F at 650 psi; 5 replicates at each test, failure time values (4) The tests for each condition can be terminated at duration equal

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/january-2018/review/implemented/9480000.impl.pdf?sfvrsn=6ca0d45f_0

9480000.impl

to the Engineer six copies of mill analysis covering chemical and physical test results. 948-1.5, for reworked plastic. Table 948-1 Stress Crack Resistance of Pipes Pipe Location Test Method Test, , Procedure B and FM 5-573 Full Test Test at 3 temperature/stress combinations: (2)(3) 176°F at 650 psi 176°F at 450 psi 158°F at 650 psi; 5 replicates at each test condition Determine failure time at 500 psi at 73.4°F ≥ 100 years (95% lower confidence) using 15 failure time values The tests

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2015/january-2015/review/implemented/9480000.impl.pdf?sfvrsn=20bb0b65_0

Section82V2-726

that testing equipment is properly maintained in accordance with the applicable test methods, . QC TESTING AND INSPECTION OF STRUCTURES General Perform QC inspections and tests at frequencies, , the strength test is the average compressive strength of two test cylinders, tested at the same age, No. 625-010-003, Florida Department of Transportation (FDOT) American Society for Testing and Materials (ASTM) Standard Test Methods and Specifications American Association of State Highway

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2026-27/materials-manual/section82v2-726.pdf?sfvrsn=ffb977ad_1

3340000.COMM

. This wording needs to be deleted. 334-5.1.2: The word "testing" needs to be added to the end, for option 2 – Regardless of mix type or placement this is how you handle PC testing. Another, placing these requirements in the test method and not the specification. 334-5.1.2 First paragraph, we should require the contractor to perform PC tests not make it optional. 334-5.1.2 Second paragraph, need to require density testing on all 10 foot shoulders on the interstate, regardless

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul07/files/3340000.comm.pdf?sfvrsn=1a733f8b_0

3460202.impl

a resistivity of 29 KOhm-cm at 28 days, when tested in accordance with AASHTO T358. Submit three 4 x 8 inch cylindrical test specimens to the Engineer for resistivity testing before mix design approval. Take the resistivity test specimens from the concrete of the laboratory trial batch or from the field, representative samples of trial batch concrete for the required plastic and hardened property tests. Cure, the resistivity test specimens at least 7 calendar days prior to the scheduled 28 day test. The average

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2017/july-2017/review/implemented/3460202.impl.pdf?sfvrsn=b9f6cb37_0

3460202.FHWA

a resistivity of 29 KOhm-cm at 28 days, when tested in accordance with AASHTO T358. Submit three 4 x 8 inch cylindrical test specimens to the Engineer for resistivity testing before mix design approval. Take the resistivity test specimens from the concrete of the laboratory trial batch or from the field, representative samples of trial batch concrete for the required plastic and hardened property tests. Cure, the resistivity test specimens at least 7 calendar days prior to the scheduled 28 day test. The average

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2017/july-2017/review/fhwa/3460202.fhwa.pdf?sfvrsn=aed6015c_0

3470000.impl

with Specification requirements. 347-4.2 Sampling and Testing: The Engineer may sample and test the concrete, test results are obtained from the use of the substituted material(s). 347-2.4 Material Storage: Use, Design: Before producing any concrete, submit the proposed mix design with compressive strength test results, tested in accordance with ASTM C39 and demonstrating the mix meets the minimum 28 day compressive strength requirement, to the Engineer on a form provided by the Department. The strength test

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2016/january-2016/review/implemented/3470000.impl.pdf?sfvrsn=4c036351_0

9940700FHWA

resistivity. The certified test report shall affirm the product meets all the requirements specified. If test results indicate significant inconsistencies in material properties, new qualification tests, shall be required to furnish to the Engineer one certified test report from the sheeting, . The certified test report shall include test results for retroreflectivity, color, adhesive backing, ,theContractorshallberequiredto furnish to the Engineer one certified test report from the sheeting manufacturer

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan06/files/9940700fhwa.pdf?sfvrsn=92e69c68_0

fdot-bdv25-977-03-sum

soil must also be noncorrosive, and it is tested for corrosive properties — pH, minimum resistivity, objective was to assure that testing methods were sufficiently precise so that variability, of soil were tested with Florida Methods (FMs) for pH, minimum resistivity, water-soluble chloride, of testing. Also, researchers visited six FDOT laboratories and nine independent laboratories to observe the testing methods and results. Field sampling methods were also studied. Samples were

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/research/reports/fdot-bdv25-977-03-sum.pdf?sfvrsn=e4c254c7_4

SS9320100

damage to the material. Materials for pavement joints shall be tested according to ASTM D 5329, of the sealant showing the defect. At least two test samples in a group of three representing, of the sealant showing the defect. At least two test samples in a group of three representing, , performance test reports from an independent laboratory showing the product meets the requirements, product is tested and approved by the Department using a primer, primer will be required for project

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2012/files/ss9320100.pdf?sfvrsn=abc4809c_0
20 of 8978 results