1785 search results for fdm

SPI-715Series

Manual (SM) Introduction, I.6 References; FDOT Design Manual (FDM) Design Assumptions and Limitations See notes on Indexes 715-001 & 002, FDM 231, FDM 261, and Structures Manual (SM), Volume 3, in accordance with FDM 231 for Lighting along with FDM 215 for Roadside Safety and FDM 222, Mounted lighting should not be used on bridges unless the light level requirement of FDM 231 cannot, FDM 943. Payment Item number Item Description Unit Measure 715-4-AB Light Pole, Complete EA See

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2027/spi/spi-715series.pdf?sfvrsn=6d8bd42e_1

SPI-425-010

 Standard Plans Instructions Topic No. 625-010-003 Index 425-010 Structure Bottoms Type J and P FY 2026-27 1 Index 425-010 Structure Bottoms Type J and P Design Criteria and Guidance FDOT Design Manual (FDM) ; Drainage Manual (DM) ; Drainage Design Guide (DDG) Structures Manual (SM) Design Assumptions and Limitations Check structures with depths over 14' below the mean high-water, ) and the FDM. Specify Class IV Concrete were required for extremely aggressive environments, see

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2027/spi/spi-425-010.pdf?sfvrsn=e71c9cbe_1

SPI-425-050

 Standard Plans Instructions Topic No. 625-010-003 Index 425-050 Ditch Bottom Inlet Type A FY 2026-27 1 Index 425-050 Ditch Bottom Inlet Type A Design Criteria and Guidance FDOT Design Manual (FDM) ; Drainage Manual (DM) ; Drainage Design Guide (DDG) Design Assumptions and Limitations This inlet is designed for ditches, medians, or other areas subject to traffic loads on limited, ) and the FDM. Payment Item number Item Description Unit Measure 425-150- INLETS, DT BOT, TYPE A EA 570-1

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2027/spi/spi-425-050.pdf?sfvrsn=13e6e208_1

SPI-425-055

 Standard Plans Instructions Topic No. 625-010-003 Index 425-055 Ditch Bottom Inlet Type K FY 2026-27 1 Index 425-055 Ditch Bottom Inlet Type K Design Criteria and Guidance FDOT Design Manual (FDM) ; Drainage Manual (DM) ; Drainage Design Guide (DDG) Design Assumptions and Limitations This inlet is to be used at locations having high flow rates, usually where an endwall could, in the Plans in accordance with the requirements of the Basis of Estimates Manual ( BOE ) and the FDM

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2027/spi/spi-425-055.pdf?sfvrsn=4f2a771a_1

SPI-425-060

 Standard Plans Instructions Topic No. 625-010-003 Index 425-060 Back of Sidewalk Drainage FY 2026-27 1 Index 425-060 Back of Sidewalk Drainage Design Criteria and Guidance FDOT Design Manual (FDM) ; Drainage Manual (DM) ; Drainage Design Guide (DDG) Design Assumptions and Limitations Maximum Pipe size for Special Concrete Endwall is 24”. Locate Yard Drains outside the Right of Way, in accordance with the requirements of the Basis of Estimates Manual ( BOE ) and the FDM

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2027/spi/spi-425-060.pdf?sfvrsn=93e24eba_1

SPI-425-061

 Standard Plans Instructions Topic No. 625-010-003 Index 425-061 Closed Flume Inlet FY 2026-27 1 Index 425-061 Closed Flume Inlet Design Criteria and Guidance FDOT Design Manual (FDM) ; Drainage Manual (DM) ; Drainage Design Guide (DDG) Design Assumptions and Limitations Closed Flume Inlets are designed for use with Type F curb and gutter only. Locate inlets outside of curb ramp, ) and the FDM. Specify the Flume type, Flume Length and number of barrels. Specify when energy

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2027/spi/spi-425-061.pdf?sfvrsn=1d40a985_1

SPI-430-021Series

 Standard Plans Instructions Topic No. 625-010-003 Index 430-021 and 430-022 Mitered End Section FY 2026-27 1 Index 430-021 and 430-022 Mitered End Section Design Criteria and Guidance FDOT Design Manual (FDM) ; Drainage Manual (DM) ; Drainage Design Guide (DDG) Design Assumptions and Limitations Locate mitered end sections in accordance with the Drainage Manual Chapter 3, Items in accordance with FDM 916 . Clearly show the location of each Mitered End Section

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2027/spi/spi-430-021series.pdf?sfvrsn=bfc9eafd_1

SPI-430-030Series

 Standard Plans Instructions Topic No. 625-010-003 Index 430-030 to 430-034 Straight Concrete Endwalls FY 2026-27 1 Index 430-030 to 430-034 Straight Concrete Endwalls Design Criteria and Guidance FDOT Design Manual (FDM) ; Drainage Manual (DM) ; Drainage Design Guide (DDG) Design Assumptions and Limitations Locate endwalls in accordance with the Drainage Manual Chapter 3, of Drainage or Summary of Miscellaneous Drainage Items in accordance with FDM 916 . Clearly show

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2027/spi/spi-430-030series.pdf?sfvrsn=4238fb17_1

28-08-johnson-russell-srcc-revised

• Background • Actual Project Examples • Summary Poll Question • Significant changes were made to the FDM related to Stormwater Pollution Prevention Plan (FDM Chapter 251) development in which publication, the FDM described the development of the Stormwater Pollution Prevention Plan 5 Poll Question • Tr, Report 23 Poll Question • FDM 251-A is filled out by _____ and is used for ______ • Contractor, / EPA 24 Results 25 Answer • FDM 251-A is filled out by Designer and is used for ERP • Wa s

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/training/transportationsymposium/2025-october/28-08-johnson-russell-srcc-revised.pdf?sfvrsn=f7cff743_1

SPI-110-200

 Standard Plans Instructions Topic No. 625-010-003 Index 110-200 Mailboxes FY 2024-25 1 Index 110-200 Mailboxes Design Criteria FDOT Design Manual (FDM) ; Domestic Mail Manual of the U. S. Postal Service (DMM) Design Assumptions and Limitations See General Notes on Index 110-200 . Plan Content Requirements Include mailbox in the Plans in accordance with the requirements of the Basis of Estimates Manual ( BOE ) . Call-out location of mailboxes. Payment Item number Item

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/spi/spi-110-200.pdf?sfvrsn=80dab5ee_2

SPI-430-001

 Standard Plans Instructions Topic No. 625-010-003 Index 430-001 Miscellaneous Drainage Details FY 2024-25 1 Index 430-001 Miscellaneous Drainage Details Design Criteria FDOT Design Manual (FDM) ; Drainage Manual (DM) ; Design Assumptions and Limitations Supplemental Details for use with other Drainage Indexes. Plan Content Requirements Included with other Drainage items. Payment Item number Item Description Unit Measure N/A Included in other Pay Items N/A Example: Stub

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/spi/spi-430-001.pdf?sfvrsn=f2ae5f91_2

SPI-446-001

 Standard Plans Instructions Topic No. 625-010-003 Index 446-001 Concrete Pavement Subdrainage FY 2024-25 1 Index 446-001 Concrete Pavement Subdrainage Design Criteria FDOT Design Manual (FDM) ; Rigid Pavement Design Manual (RPDM) Design Assumptions and Limitations Edgedrain sections for DRAINCRETE SUBDRAINAGE are applicable to pavement construction identified as RIGID PAVEMENT on Index 120-001 . Plan Content Requirements Location of edgedrain installation and outlet pipes

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/spi/spi-446-001.pdf?sfvrsn=39b88a85_2

SPI-520-005

 Standard Plans Instructions Topic No. 625-010-003 Index 520-005 Concrete Shoulder Gutter Spillway FY 2024-25 1 Index 520-005 Concrete Shoulder Gutter Spillway Design Criteria FDOT Design Manual (FDM) ; Drainage Manual (DM) Design Assumptions and Limitations Use in conjunction with Shoulder Gutter where inlets, pipes and endwalls are not practical. Plan Content Requirements If spillway empties into an unpaved ditch, the detail should be modified and included in the Plans

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/spi/spi-520-005.pdf?sfvrsn=e80d0878_2

SPI-700-041

; Structures Design Guidelines (SDG) ; FDOT Design Manual (FDM) Design Assumptions and Limitations The maximum span length of Span Sign Structures is 220 feet. See the notes on Index 700-041 , FDM 230 , FDM 261 , Structures Manual (SM) , Volume 3 and the SDG for additional information. Use, inches of the truss support welds. Plan Content Requirements See the FDM 940 . Complete the “Span

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/spi/spi-700-041.pdf?sfvrsn=5e333cff_2

Exhibit 230-8

 AND LANE LINE MARKINGS INTO SIGNALIZED INTERSECTION TYPICAL DOTTED LINE MARKINGS TO EXTEND CENTER LINE Legend Lane Assignment Arrow Arterial/Collector Traffic Installation Details 1) 2) FDM 230.4.6. receiving lane meets or exceeds 60 ft. See the side street stop bar to the arterial d ö 60 ft. The distance of the left turn from d 1 9 ' - 6 7 / 1 6 " 4 3 ' - 3 1 / 2 " be dotted guide yellow lines. Center line extensions in the intersection shall d 1 9

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/2025/review/exhibit-230-8.pdf?sfvrsn=6829daa2_1

Exhibit 230-8

 AND LANE LINE MARKINGS INTO SIGNALIZED INTERSECTION TYPICAL DOTTED LINE MARKINGS TO EXTEND CENTER LINE Legend Lane Assignment Arrow Arterial/Collector Traffic Installation Details 1) 2) FDM 230.4.6. receiving lane meets or exceeds 60 ft. See the side street stop bar to the arterial d ö 60 ft. The distance of the left turn from d 1 9 ' - 6 7 / 1 6 " 4 3 ' - 3 1 / 2 " be dotted guide yellow lines. Center line extensions in the intersection shall d 1 9

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/2025/exhibit-230-8.pdf?sfvrsn=42215c31_1

SPI-110-200

 Standard Plans Instructions Topic No. 625-010-003 Index 110-200 Mailboxes FY 2025-26 1 Index 110-200 Mailboxes Design Criteria FDOT Design Manual (FDM) ; Domestic Mail Manual of the U. S. Postal Service (DMM) Design Assumptions and Limitations See General Notes on Index 110-200 . Plan Content Requirements Include mailbox in the Plans in accordance with the requirements of the Basis of Estimates Manual ( BOE ) . Call-out location of mailboxes. Payment Item number Item

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/spi/spi-110-200.pdf?sfvrsn=4bb50a3e_1

SPI-430-001

 Standard Plans Instructions Topic No. 625-010-003 Index 430-001 Miscellaneous Drainage Details FY 2025-26 1 Index 430-001 Miscellaneous Drainage Details Design Criteria FDOT Design Manual (FDM); Drainage Manual (DM); Design Assumptions and Limitations Supplemental Details for use with other Drainage Indexes. Plan Content Requirements Included with other Drainage items. Payment Item number Item Description Unit Measure N/A Included in other Pay Items N/A Example: Stub Connection

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/spi/spi-430-001.pdf?sfvrsn=14d3f66d_1

SPI-446-001

 Standard Plans Instructions Topic No. 625-010-003 Index 446-001 Concrete Pavement Subdrainage FY 2025-26 1 Index 446-001 Concrete Pavement Subdrainage Design Criteria FDOT Design Manual (FDM) ; Rigid Pavement Design Manual (RPDM) Design Assumptions and Limitations Edgedrain sections for DRAINCRETE SUBDRAINAGE are applicable to pavement construction identified as RIGID PAVEMENT on Index 120-001 . Plan Content Requirements Location of edgedrain installation and outlet pipes

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/spi/spi-446-001.pdf?sfvrsn=d7f145ca_1

SPI-520-005

 Standard Plans Instructions Topic No. 625-010-003 Index 520-005 Concrete Shoulder Gutter Spillway FY 2025-26 1 Index 520-005 Concrete Shoulder Gutter Spillway Design Criteria FDOT Design Manual (FDM) ; Drainage Manual (DM) Design Assumptions and Limitations Use in conjunction with Shoulder Gutter where inlets, pipes and endwalls are not practical. Plan Content Requirements If spillway empties into an unpaved ditch, the detail should be modified and included in the Plans

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/spi/spi-520-005.pdf?sfvrsn=3a7c7db0_1
20 of 1785 results