5480206.resp

Materials Office, the acceptable pH range will be revised to 5 to 9. 4. In both of these tests, or soluble sulfate, respectively, in the backfill sample. Even though the test method would not change, the text in the Criteria – Test Method table in Article 548-2.6 will be changed from “Sulfate, ’ forwarding of Comment 4. from Daniel Henriques: The tests is for water soluble sulfates only. It is not a total sulfate test, since we would not measured sulfates that are bound chemically. For that we would

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan11/files/5480206.resp.pdf?sfvrsn=4dddf3e1_0

5600705.origind

below those specified above, soluble salt/conductivity testing frequency may be reduced to one test, above, rewash the entire surface area and retest. If testing at a frequency of one test per shift, , sulfate and nitrate concentrations on all steel surfaces using soluble salts test kits meeting, . Perform the tests after washing and after each applied coat of the coating system. Ensure the non-visible, method (salt test kits or conductivity meter) test three random locations in the first 1000 square feet

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/january-2014/review/internal/5600705.origind.pdf?sfvrsn=6a1b7a9d_0

5600204.comm

) 1. 560-7.5 – the requirement of testing every 1000 s.f. is an overkill. We have been performing these tests since FDOT implemented the requirement and have yet to find any soluble salts on any of the surfaces tested on any of our new construction projects. As this just adds more money to the cost of a project, possibly the Specification could be clarified to require less testing on new

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul13/files/5600204.comm.pdf?sfvrsn=a1c9116c_0

1250801FHWA

. Construct a test section of the length of one LOT. Perform five quality control (QC) tests at random locations within the test section. All five tests must meet the density required by 125-9.2, the requirements of 125-9.2 or when the QC tests cannot be verified, construct a new test section, testing frequency in 125-9.2.3.1. SUBARTICLE 125-8.1.5 has the following Administrative change, the soil envelope, then the Contractor must demonstrate with a successful test section that density

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2025-26/review/fhwa/1250801fhwa.pdf?sfvrsn=1a152dc6_1

DEV403EO (8-11-20)

% or more of the test dolly. A test result will be the average of three pull tests with no one pull less than 175 psi on a test section of 1.5 feet x 3 feet consisting of two courses. Repair all tested, and for high friction treatment systems is 65. 403-4.2 Bond Testing: Test the tensile bond, joints, furnishing and operating testing devices, written test reports. Cost for restored spall, personnel in the application and testing of the overlay system prior to application

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/special-case/developmental/dev403eo-(8-11-20).pdf?sfvrsn=b64e0167_1

3470000resp

to be qualified as a 346 which would also cost due to personnel and testing needed. Response: Though, . 347-4 Sampling and Testing - Since there is no longer a sampling and testing requirement, if there is not a design mix or any testing performed? Response: Currently there is no requirement for an approved non-structural mix design. 347-4 Sampling and Testing was struck and placed under, test any material at their discretion. The contractor certifies to the 2500 psi based

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul19/files/3470000resp.pdf?sfvrsn=e79bd2d3_2

9710202comm

the current ASTM D1155 test method or reference the AASHTO method for testing size and roundness, to see FM 5-620 / cannot locate the test method Response: 2. Reference to FM 5-620 Gradation ----we need to see FM 5-620 / cannot locate the test method Response: 3. Packaging: They need to allow, Comments: (1-7-18) 1. What is FM 5-620? I assume it is a Florida test method, but I do not find this method listed on the web site under FDOT Test Methods. I would question referencing a test method

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul19/files/9710202comm.pdf?sfvrsn=59d662a9_2

9710202comm

the current ASTM D1155 test method or reference the AASHTO method for testing size and roundness, to see FM 5-620 / cannot locate the test method Response: 2. Reference to FM 5-620 Gradation ----we need to see FM 5-620 / cannot locate the test method Response: 3. Packaging: They need to allow, Comments: (1-7-18) 1. What is FM 5-620? I assume it is a Florida test method, but I do not find this method listed on the web site under FDOT Test Methods. I would question referencing a test method

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul19/files/9710202comm9d56fa431492488b94a14029cb45acc3.pdf?sfvrsn=a123e1f6_2

2000202-722origind

for constructing stockpiles for sampling and testing. f. Method for sampling and reporting test results. 3, perform sampling and testing. Materials will be accepted if test results meet the requirements, of the Section and no individual LBR test is less than 120, the sampling and testing frequency may, the Engineer in writing prior to reducing testing frequency. If any QC LBR test result falls below 120, . Collect and test a minimum of three samples from the preliminary stockpile. Once the stockpile

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/internal/2000202-722origind.pdf?sfvrsn=c85c0b6e_4

SS7810000

. The operational status may also be tested when the TMC or a laptop computer prompts a pixel test. Ensure, and maintenance. Provide labeled test points for checking essential voltages. Ensure that all external, microns in diameter and larger. Ensure that the ventilation system is automatically tested once each day, and that it may be tested on command from remote and local control access locations. Ensure, in Test Method A of the CIE 127 (1997) standard. Provide the LED brightness and color bins

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2011/january-2011/workbook/ss7810000.pdf?sfvrsn=85e510ab_0

SS9450000

. Ensurethatthepipejointshavebeentestedattheplanthydrostatically at the specified pressure using test methods in ASTM D 3212, in internal diameter using the parallel plate testing methodology of ASTM D 2412. Load, the hugger band or associated hardware. Testing shall be witnessed by the Engineer. 945-2 Aluminum, compound. The bolts may be sampled and tested before erection or may be accepted on the basis, by the Engineer. 945-2.3CertificationofTests:Forallaluminum materials, test certifications

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2007/january-2007/workbook/ss9450000c9219fba401a4bcfaf337ff3ffb93327.pdf?sfvrsn=285c8bad_0

9940201-724CommRespwithattachment

, and durability, and so this is redundant. D4956 already has testing and panel prep requirements, sheets, performance test reports from an independent laboratory showing the sign sheeting system, : 994-2.3.1 General: Sheeting, process inks and overlay materials shall be tested in accordance, requirements that are color dependent, each color included in the APL application shall be tested, systems consisting of inks and/or overlays will be tested as a system consisting of white base sheeting

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/comments-responses/9940201-724commrespwithattachment.pdf?sfvrsn=7d6749cf_1

CM-671-01 ATC Traffic Controller

or third party test report that demonstrates compliance with this requirement. A completed Testing, testing per the requirements of the ATC 5201 Standard, v06A.37, Section 7.7, TEST PROCEDURES: TRANSIENTS, test report that demonstrates compliance with this requirement. A completed Testing Laboratory, Test Cases (Steps): ATC002 (Step 1) FORMTEXT       FORMTEXT       Init.: FORMTEXT       2 995-10, FORMTEXT Indicate location of requested information in submittal. TERL Test Cases (Steps): ATC001

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/traffic/traf_sys/compliance-matrices-2022/cm-671-01-atc-traffic-controller.docx?sfvrsn=44f9c7e4_1

7800000.FHWA

power, data, and video lines. 780-5 4 Testing. Perform the required tests for the ITS equipment, or system under test. Furnishallequipment, software, and supplies necessary for conducting the tests, the required tests for the ITS equipment installed. Notify the Engineer of ITS installation testing, tocommencement of testing. Ensure that the test plan demonstrates each and every functional, necessary for conducting the tests. Include in the test documentation the last calibration date

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul12/files/7800000.fhwa.pdf?sfvrsn=5346821b_0

6110203-722FHWA

to all tests to permit the Engineer or their representative to observe each test. If any unit fails, Installation: Test all stand-alone functions of the ITS devices as detailed in the Contract Documents, of 10 calendar days prior to all tests to permit the Engineer or their representative to observe each test. If any unit fails to pass its stand-alone test, correct the unit, or substitute another unit in its place, then repeat the test. If a unit has been modified as a result of a stand-alone test

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/fhwa/6110203-722fhwa.pdf?sfvrsn=294ca6_2

9900400-722FHWA

strength of 40 psi when tested according to ASTM D638. A rectangular test specimen 6 inches by 1 inch, elongation of 25% when tested in accordance with ASTM D638. 990-4.9 Plastic Pull test: The stripes, tensile strength of 40 psi when tested according to ASTM D638. A rectangular test specimen 6 inches, a minimum elongation of 25% when tested in accordance with ASTM D638. 990-4.9 Plastic Pull test, Supplemental Specification. The changes are proposed by Karen Byram to remove friction testing

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/fhwa/9900400-722fhwa.pdf?sfvrsn=e287d4e7_2

3340104-122FHWA

the proposed mix design with supporting test data indicating compliance with all mix design criteria, will consider any marked variations from original test data for a mix design or any evidence, tested in accordance with AASHTO T 304-17 (2020), Method A, meet the uncompacted void content, 334-5.1.1 is deleted and the following substituted: 334-5.1.1 Sampling and Testing Requirements, to be split into three smaller samples; one for QC, one for Verification testing and one

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/january-2022/review/fhwa/3340104-122fhwa.pdf?sfvrsn=7b212fe9_2

9900202.comm

to NTPEP for additional testing, would FDOT conduct a field test deck to test the removability, to be tested by Product Evaluation on a field test deck, since this was removed with the latest, matthew@cloverleafcorp.com Comments: Regarding 990-4.11, I note that FM test method 5-541 no longer has provisions for a test deck for removable tape, but instead just reverts back to NTPEP test, is met? Is this a test to be looked for by the Product Evaluation group in a Product Application

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan10/files/9900202.comm.pdf?sfvrsn=5765ef73_0

SP1610000

for stabilizing material. Base the spread rate on tests performed by a testing laboratory approved by the Engineer. Furnish copies of reports for all tests and calculations used in determining the spread rate, will perform Verification sampling and tests at a minimum frequency listed in the table below. Test, and the stabilizing material for verification tests. Make a separate determination of the spread rate, rate of stabilizing material used, based on test data and calculations submitted by the Contractor

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2012/files/sp1610000.pdf?sfvrsn=8031f203_0