D7460000.DO

at the top and bottom to deter tampering. Construct the door double flanged on all four sides and equip it

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2003/january-2003/workbook/d7460000.do.pdf?sfvrsn=4a6b5c5f_0

7460000SP

and capped at the top and bottom to deter tampering. Construct the door double flanged on all four sides

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2005/january-2005/workbook/7460000sp.pdf?sfvrsn=c6ba2f50_0

7460000SP

and capped at the top and bottom to deter tampering. Construct the door double flanged on all four sides

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2006/january-2006/workbook/7460000sp.pdf?sfvrsn=2960c8c0_0

4130302-722FHWA

D1481) 8.5 - 9.0 lb/gl at 77 o F Flash Point (ASTM D93) > 200 o F (Pensky Martens CC) Odor Low, ) 8.5 - 9.0 lb/gl at 77 o F Flash Point (ASTM D93) > 200 o F (Pensky Martens CC) Odor Low Bulk

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/fhwa/4130302-722fhwa.pdf?sfvrsn=7d23868b_2

9160203.FHWA

% (Not applicable for PG 76-22 (ARB)) Flash Point, AASHTO T48-06 (2015) Cleveland Open Cup Minimum, in Trichloroethylene Minimum 99.0% (Not applicable for PG 76-22 (ARB)) Flash Point, AASHTO

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2019/january-2019/review/fhwa/9160203.fhwa.pdf?sfvrsn=26ea7783_0

Annual_Report FY 2023-24

with “altered flag certifications” working on Department projects. Specifically, the complainant advised the workers with “altered flagger [MOT] certifications” were sent to work for a Department contractor, of this inquiry, the OIG reviewed applicable Department policies and procedures, FDOT MOT Basic Flagger, flagger certification records, or untrained/uncertified MOT workers being sent to a Department job

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/ig/reports/annual_report-fy-2023-24.pdf?sfvrsn=cf45f572_1

SPI-548-020

of the retaining wall, and a flat area meeting the requirements of FDM 215.2.6 (10'-0" Min.) cannot be provided, then the flat area can be reduced up to a minimum of 4'-0". Plan Content Requirements

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/spi/spi-548-020.pdf?sfvrsn=737d3512_2

SPI-548-020

of the retaining wall, and a flat area meeting the requirements of FDM 215.2.6 (10'-0" Min.) cannot be provided, then the flat area can be reduced up to a minimum of 4'-0". Plan Content Requirements

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/spi/spi-548-020.pdf?sfvrsn=1b8abe24_1

9600202-724FHWA

. 32. Seal Anchorage cap with “O”-ring seals or precision fitted flat gaskets placed against, flat gaskets placed against the bearing plate. 3. Provide holes of 3/8 inch minimum diameter

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/fhwa/9600202-724fhwa.pdf?sfvrsn=39976919_1

4300801.FHWA

end. Use either a spiral (helical) band with a gasket or a flat band with gaskets as required, (helical) band with a gasket or a flat band with gaskets as required by 430-8.1.2 (2) to join the pipe

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/january-2014/review/fhwa/4300801.fhwa.pdf?sfvrsn=de4cd3a0_0

SPI-548-020

of the retaining wall, and a flat area meeting the requirements of FDM 215.2.6 (10'-0" Min.) cannot be provided, then the flat area can be reduced up to a minimum of 4'-0". Plan Content Requirements

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2027/spi/spi-548-020.pdf?sfvrsn=5265ad47_1

D5-09-04-24BSN

(*) FLAGLER 17 E53F5 44880015201(*) BREVARD 22 E54F2 45171115201(*) VOLUSIA 24 E58C7 42795817221(*) VOLUSIA, Proposal: E53F4 District:05 Counties: FLAGLER Road Name: SR A1A Limits: 73030000 Project(s, in Flagler County. PREQUALIFICATION REQUIRED Call Order: 003 Proposal: E53F4 ALT Item Description Unit, FLASHING BEACON, FURNISH & INSTALL- AC, COMPLETE SIGN ASSEMBLY- BACK TO BACK AS 2.000 0654- 2- 60 MIDBLOCK CROSSWALK: RECTANGULAR RAPID FLASHING BEACON, REMOVE COMPLETE SIGN ASSEMBLY AS 2.000

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d5/lettings/2024/sep04/d5-09-04-24bsn.pdf?sfvrsn=8b6f0fa7_1