4550 search results for fla

9750000-723impl

and ceiling exposure limits for all components, lower and upper explosive limits, flash point, boiling, sixteen flat and four composite test panels in accordance with AASHTO R-31 (in color White, Grey or Green, twelve flat test panels for random laboratory verification testing. 975-2.2.2 Outdoor Exposure Testing: Prepare and coat eight test panels (four flat and four composite) for exposure, . 975-7.2 Performance Requirements: For laboratory testing, use flat test panels prepared

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/implemented/9750000-723impl.pdf?sfvrsn=90c6a26a_1

9750000-723origind

components, lower and upper explosive limits, flash point, boiling point, amount of volatile organic, the application requirements of Section 560. Prepare and coat sixteen flat and four composite test panels, flat test panels for random laboratory verification testing. 9750000 All Jobs 975-2.2.2 Outdoor Exposure Testing: Prepare and coat eight test panels (four flat and four composite) for exposure, installation. 975-7.2 Performance Requirements: For laboratory testing, use flat test panels

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2023-24/review/internal/9750000-723origind.pdf?sfvrsn=fff1826e_1

SPI-521-480

, perpendicular, angled or flared end bent wing walls. Each Standard includes several schemes, not meeting Case 1 or 2) None Flared with parallel portions Case 1: On Wing Wall Wing wall, : On Bridge (when not meeting Case 1 or 2) None Flared without parallel portions On Bridge None

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/spi/spi-521-480.pdf?sfvrsn=3b25f856_1

E6P22-R0BidTabs

: 0105 E536 6423 GUARDRAIL END TREATMENT-FLARED APPROACH TERMINAL, REPLACE, NCHRP 350 3.000 EA, 0170 E536301501 END ANCHOR ASSEM TYPE II (REPL FLARED END SECT) 2.000 EA 100.00000 200.00, E536322511 END ANCHOR ASSEM FLARED (REPL SPECIAL END SHOE) 3.000 EA 350.00000 1,050.00 50.00000 150.00

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d6/bid-tabs/2024/feb22/e6p22-r0bidtabs.pdf?sfvrsn=3b1bf716_1

SPI-521-480

, perpendicular, angled or flared end bent wing walls. Each Standard includes several schemes, not meeting Case 1 or 2) None Flared with parallel portions Case 1: On Wing Wall Wing wall, : On Bridge (when not meeting Case 1 or 2) None Flared without parallel portions On Bridge None

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/spi/spi-521-480.pdf?sfvrsn=9da22426_1

5360000.impl

using legible lettering at least 3/4 inch in height. If the Plans call for a "flared" approach, to construct any Department-approved "flared" terminal assembly identified on the APL, subject, or flared approach terminals, Type II trailing anchorages, CRT end treatments, and double faced approach

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2017/july-2017/review/implemented/5360000.impl.pdf?sfvrsn=9fc1e2f7_0

SPI-521-480

, perpendicular, angled or flared end bent wing walls. Each Standard includes several schemes, not meeting Case 1 or 2) None Flared with parallel portions Case 1: On Wing Wall Wing wall, : On Bridge (when not meeting Case 1 or 2) None Flared without parallel portions On Bridge None

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2027/spi/spi-521-480.pdf?sfvrsn=4059f1c4_1

CM-641-01 Camera Lowering Device

, shrinks, and other flaws. FORMDROPDOWN FORMTEXT Applicant may provide comments in this field, (Step 33) FORMTEXT       FORMTEXT       Init.: FORMTEXT       50 The cabinet door is double flanged

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/traffic/traf_sys/compliance-matrices-2022/cm-641-01-camera-lowering-device.docx?sfvrsn=307a5052_1

2025 Florida Aviation Project Handbook

per § 287.055, Fla. Stat. Request Yo u r G r a n t R e i m b u r s e m e n t s R e g u l a r FDOT, aviation fuel sales, per § 206.9825, Fla. Stat. After administrative costs and commercial carrier, m a t i n g C o n f e rence. In accordance with § 331 Fla. Stat., spaceport grants are issued, S o u rce: § 332, Fla. Stat. All publicly owned Florida airports that are open for public use, , Fla. Stat. In general, Florida law allows FDOT to fund any capital project on airport property

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/aviation/2025-florida-aviation-project-handbook.pdf?sfvrsn=19c49244_5

Florida Aviation Project Handbook-Current

per § 287.055, Fla. Stat. Request Yo u r G r a n t R e i m b u r s e m e n t s R e g u l a r FDOT, aviation fuel sales, per § 206.9825, Fla. Stat. After administrative costs and commercial carrier, m a t i n g C o n f e rence. In accordance with § 331 Fla. Stat., spaceport grants are issued, S o u rce: § 332, Fla. Stat. All publicly owned Florida airports that are open for public use, , Fla. Stat. In general, Florida law allows FDOT to fund any capital project on airport property

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/aviation/florida-aviation-project-handbook-current.pdf?sfvrsn=116003ee_4

Utility Companies Doing Business with FDOT

03-18-99 Clay Electric Cooperative, Inc.   04-08-99   08-26-99 Cogent Communications of Fla, Inc

https://www.fdot.gov/programmanagement/utilities/97laterua.shtm

FDOT Prioritizes Emerging Aviation Technology to Expand Florida's Transportation Network

on Advanced Air Mobility  TAMPA, Fla. – This week, the Florida Department of Transportation (FDOT

https://www.fdot.gov/info/co/news/2024/04042024

FDOT Picks Up More Than 100,000 Cubic Yards of Debris Within Two Weeks Following Hurricane Idalia

-and-toss, and debris removal~ TALLAHASSEE, Fla. — Today, Governor Ron DeSantis highlighted state efforts

https://www.fdot.gov/info/co/news/2023/09152023-2

Governor Ron DeSantis: Florida’s Seaports Are Open and Ready to Meet Holiday Demands

INDEX A-Z Search For Immediate Release: October 19, 2021 Contact: Governor’s Press Office, (850) 717-9282, Media@eog.myflorida.com Governor Ron DeSantis: Florida’s Seaports Are Open and Ready to Meet Holiday Demands JACKSONVILLE, Fla. – Today, Governor Ron DeSantis announced that Florida Seaports have open

https://www.fdot.gov/info/co/news/2021/10192021-gov

Groundbreaking Ceremony Launches Construction of New NASA Causeway Bridge

as bridges to Florida’s future in space ~ TITUSVILLE, Fla. — Today, Lt. Governor Jeanette Nuñez

https://www.fdot.gov/info/co/news/2021/12142021
20 of 4550 results