9190 search results for test

9930000fhwa

. Thereflectorelement shall meet the test requirements specified below. 993-1.2 Durability Tests For Type A Reflectors: (a)SealTest: The following test will be used to determine if a reflector is adequately, to be furnished. Thereflectorelement shall meet the test requirements specified below. 993-1.2 Durability Tests, tested. Failure of more than two reflectors out of 50 subjected to test shall constitute failure, for water intake. Failure of more than two of the 50 samples tested shall be cause for tentative rejection

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul03/files/9930000fhwa.pdf?sfvrsn=b4a43a1a_0

4550000.comm

testing ranges? Just wondering if this change has something to do with the fact that no one seems to be able to get FDOT certified for polymer slurry even though product documentation details proper test, wing.heung@dot.state.fl.us Comment: (7-24-12) Type: 4550000 Text: 1) For structures without tested piles, , allow the Engineer one work day after driving the dynamic load tested piles for the Engineer, meant to be 455-23.7 or 455-15.5 ? Response 3) On 455-18 and the new 455-24.4 “test hole

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan13/files/4550000-comm.pdf?sfvrsn=271fd082_4

SS9620102

Testing: For structural steel subjected to tensile stress used for main load- carrying members or components (as defined in Section 460), meet the ASTM A 709 impact test requirements for non-fracture, ) is deleted and the following substituted: 962-8.4.2 Testing: Structural steel tubing subjected to tensile, the impact test requirements of ASTM A 709 for non-fracture and fracture critical tension components

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2012/files/ss9620102.pdf?sfvrsn=7999bb9a_0

SS9620102

Testing: For structural steel subjected to tensile stress used for main load- carrying members or components (as defined in Section 460), meet the ASTM A 709 impact test requirements for non-fracture, ) is deleted and the following substituted: 962-8.4.2 Testing: Structural steel tubing subjected to tensile, the impact test requirements of ASTM A 709 for non-fracture and fracture critical tension components

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/julworkbook2011/files/ss9620102.pdf?sfvrsn=e3378c5e_0

SS9620102

Testing: For structural steel subjected to tensile stress used for main load- carrying members or components (as defined in Section 460), meet the ASTM A 709 impact test requirements for non-fracture, ) is deleted and the following substituted: 962-8.4.2 Testing: Structural steel tubing subjected to tensile, the impact test requirements of ASTM A 709 for non-fracture and fracture critical tension components

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2011/january-2011/workbook/ss9620102.pdf?sfvrsn=b7b6d2cd_0

D9940000.do

of test samples shall be field tested in accordance with FM 5-571 for each color, with their approved usage. Samples shall be taken in accordance with the Department’s Sampling, Testing, instrumental color testing, shall conform to the requirements of ASTM D4956. In addition to ASTM D4956 Table, shall be tested in accordance with ASTM D882. 994-3.7 Physical Properties: The retroreflective, of this Section. The certified test report shall include test results for retroreflectivity, color

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2003/january-2003/workbook/d9940000.do.pdf?sfvrsn=a4067c92_0

SP4550000DBFHWA

to the satisfaction of the Engineer. 455-2.10 Disposition of Tested Piles/Shafts: After completing testing, cut, dynamic testing. During dynamic load tests, replace the pile cushion when any of the pile stress, the fill before installing end-bent piling/shafts, except when driving specified test piling in end, temporary casings before the drilled shaft elapsed time has expired. 455-2 Static Compression Load Tests. 455-2.1 General: Employ a professional testing laboratory, or Specialty Engineer with prior

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2026-27/review/fhwa/sp4550000dbfhwa.pdf?sfvrsn=ffad7a4b_1

3300202.fhwa

by Greg Sholar of the State Materials Office to expand the minimum process control testing requirements and to exclude sidewalks and bicycle/shared use paths from straightedge testing. Please review, Control Testing Requirements: Perform, as a minimum, the following activities at the testing, production exceeds 1,000 tons, perform these tests a minimum of two times per day. Quality Control tests used in the acceptance decision may be used to fulfill this requirement. Verify modifier

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jul11/files/3300202.fhwa.pdf?sfvrsn=c77cd5d6_0

4551508.impl

to perform control tests using suitable apparatus on the mineral slurry mixture to determine the following, to the drilled shaft excavation: Perform the following tests on the mineral slurry supplied to the shaft, to be measured Range of Results at 68ºF Test Method Density 64 to 73 lb/ft (in fresh water environment, in the above table when field conditions warrant as successfully demonstrated in a test hole, the Contractor can continue to use them. Perform tests to determine density, viscosity, and pH

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2015/january-2015/review/implemented/4551508.impl.pdf?sfvrsn=a71ae211_0

SP4550000DBD01-722FHWA

expired. 455-2 Static Compression Load Tests. 455-2.1 General: Employ a professional testing, driving of the test pile or reaction piles, whichever occurs last. Do not begin static load testing, with transportation to assist as required during load test setup and conducting of the load tests, . 455-2.10 Disposition of Tested Piles/Shafts: After completing testing, cut off the tested piles, satisfactory field trial during dynamic testing. During dynamic load tests, replace the pile cushion

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2022/july-2022/review/fhwa/sp4550000dbd01-722fhwa.pdf?sfvrsn=b19fdf7e_2

4550510.origind

and re-drives in steel piles as dynamic tests, to reduce the frequency of slurry sampling and testing, as dynamic tests, reduce the frequency of slurry sampling and testing in shafts, reduce the time between, testing. Make each pile to be dynamically tested with externally attached instruments available, a paragraph to allow the use of instrumented set-checks/re- drives to be considered as dynamic testing, for the purpose of using a higher phi factor for 100% Dynamic Testing specified in the SDG 455-15.8.3

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/january-2014/review/internal/4550510.origind.pdf?sfvrsn=8300ca78_0

9320300comm

on testing for the degree of cure, it is noted that the degree of cure obtain directly from the rebar samples may be variable, and the response of the test per ASTM E2160 non-applicable. This is probably due to the relative high fiber content of the sample used in testing. Tests made from resin, 3-2. ¬ Table 3-4: removing the degree of cure test for project tests should be considered, given, pads (Section 932-2.3.2) re-testing should be stated if one of the tests per Table 3-4 fails

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2020/january-2020/review/comments-responses/9320300comm.pdf?sfvrsn=b9ad3f61_2

Scope of Services

required tests. 15.3 Laboratory Testing: Perform all tests in accordance with applicable testing, and Testing: Inspect, sample, test and report on Concrete Production Plants to ensure compliance, -Stress and Precast Production Facility Inspection and Testing: a. Inspect, sample, test and report,  Scope Doc. November 20, 2025 1 EXHIBIT "A" District Geotechnical & Material Testing Contracts, Communication and Reporting:………………………………………………………………………………………..7 8.0 Reporting Test Results

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/materials/contract/documents/scope-of-services.pdf?sfvrsn=2536d968_4

Scope of Service

and Transportation Officials (AASHTO) Test Methods • American Society for Testing and Materials (ASTM) Standards, the QC test results into the Department’s database system within one working day of the testing. Make, Testing: Perform all tests in accordance with applicable testing Standard. Comply with all, testing. 15.4Concrete Plant Inspection and Testing: Inspect, sample, test and report on Concrete, . 4.Perform Pile Dynamic Testing. 5.Provide printed/plotted (PDF) and electronic copies of test pile data

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/materials/contract/documents/scope-of-service.docx?sfvrsn=d6100b09_4

SP4550100DTwoTP

Compression Load Tests. 455-2.1 General: Employ a professional testing laboratory, or Specialty, of the load test data which represents the designated area. Do not begin static load testing, . Return all load test equipment supplied by the Department within 30 days after completing the load tests, during load test setup and conducting of the load tests. Provide qualified personnel, as determined, to the satisfaction of the Engineer. 455-2.10 Disposition of Tested Piles/Shafts: After completing testing

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/janworkbook2015/files/sp4550100dtwotp.pdf?sfvrsn=39c25e7e_4

3340104.impl

of gyratory molds in accordance with FM 5-585. Prior to testing volumetric samples, condition the test, Sampling and Testing Requirements: Obtain the samples in accordance with FM 1-T 168. Obtain samples, Control, one for Verification and one for Resolution testing; each sample at approximately 35 pounds. The split samples for Verification testing and Resolution testing shall be reduced in size, testing. Theasphaltcontentofthe mixture will be determined in accordance with FM 5-563. In the event

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan12/files/3340104.impl.pdf?sfvrsn=1d50d18_0

9480203.resp

test. With this, more variables with procedures are greater, as experienced during the RR testing, and installation criteria, as well as the material testing properties. Those recommendations are listed in Chapter, sections. 3. How is “failure” defined in the Stress Crack Resistance tests? In other words, how do you determine that a specimen has failed? Response: Process is part of test method FM5-573. Calculation, to 9480203 to the HDPE testing requirements that mandates which Lab facilities are approved

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/implemented/workbooks/history/jan11/files/9480203.resp.pdf?sfvrsn=2794908e_0

9320200-724origind

for testing and one for verification in the event of a failing test result. LOTs will be sampled, be equal to the average test result from all three LOTs minus three standard deviations. n – Tests, or discontinuities and without damage to the material. Materials for pavement joints shall be tested, shall be measured perpendicular to the side of the sealant showing the defect. At least two test, two test samples in a group of three representing a given sample of sealant shall meet

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/internal/9320200-724origind.pdf?sfvrsn=32f5b967_1

GL-04

and testing requirements are met and enforcing the requirement that all samples and test are taken randomly? Does the field test verify this? [Spec 120-10] 10. Does the CEI have an appropriate process to ensure that the correct proctor is used when density tests results are evaluated for material, . Has the CEI enforced the requirement that all required density test results are documented, exceed plan limits, are extra tests taken? [160-4] 28. For any area where the bearing value

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/construction/constadm/guidelist/inspectguidelist/fy1415/gl-04.pdf?sfvrsn=baae566b_0
20 of 9190 results