TERMS OF USE:

Bentley Microstation Drawings are provided (as zipped DGN files) for designers who decide to modify Standard Plans to suit project specific requirements. Data and details found outside of the printed border region is for FDOT internal use only and should not be used. Modifications to the Standard Plans must be performed under the direct supervision of a Professional Engineer. If any portion of the Standard Plans is modified, the Professional Engineer becomes the Engineer of Record (EOR) responsible for the changes. See the FDOT Design Manual (FDM), Chapter 115, for additional information on the use of modified Standard Plans within FDOT Contract Plans.

 

Skip to Standard Plans for Bridge Construction

 

(Last updated: 12/22/2018)

 

Standard Plans for Road Construction

 

Standard Plans IndexDGNCEL

Index Title

Design Standards Index

Miscellaneous

000-510DGN 

Superelevation Transitions - High Speed Roadways

510
000-511DGN 

Superelevation Transitions - Low Speed Roadways

511
000-525DGN 

Ramp Terminals

525

General Construction Operations

  Maintenance of Traffic
102-100DGN 

Temporary Barrier

415
102-110DGN 

Type K Temporary Concrete Barrier System

414
102-120DGNCEL

Low Profile Barrier

412
102-600DGN 

General Information for Traffic Control Through Work Zones

600
102-601DGN 

Two-Lane, Two-Way, Work Outside Shoulder

601
102-602DGN 

Two-Lane, Two-Way, Work on Shoulder

602
102-603DGN 

Two-Lane, Two-Way, Work Within the Travel Way

603
102-604DGN 

Two-Lane, Two-Way, Work in intersection

604
102-605DGN 

Two-Lane, Two-Way, Work Near Intersection

605
102-606DGN 

Two-Lane, Two-Way, Work Within the Travel Way-Signal Control

606
102-607DGN 

Two-Lane, Two-Way, Mobile Operation, Work on Shoulder, Work Within the Travel Way

607
102-608DGN 

Two-Lane, Two-Way, Temporary Diversion Connection

608
102-611DGN 

Multilane, Work Outside Shoulder

611
102-612DGN 

Multilane, Work on Shoulder

612
102-613DGN 

Multilane, Work Within the Travel Way - Median or Outside Lane

613
102-614DGN 

Multilane, Work Within the Travel Way - Center Lane

614
102-615DGN 

Multilane, Work in Intersection

615
102-616DGN 

Multilane, Work Near Intersection - Median or Outside Lane

616
102-617DGN 

Multilane, Work in Intersection - Center Lane

617
102-618DGN 

Multilane, Work in Intersection - Two Lanes Closed - 45 mph or Less

618
102-619DGN 

Multilane, Mobile Operations, Work on Shoulder, Work Within the Travel Way

619
102-620DGN 

Multilane, Divided, Temporary Diversion Connection

620
102-621DGN 

Multilane, Undivided, Temporary Diversion Connection

621
102-622DGN 

Multilane, Work Near Intersection-Temporary Diversion Connection-35 mph or Less

622
102-623DGN 

Multilane, Work Within the Travel Way Double Lane Closure

623
102-625DGN 

Temporary Road Closure - 5 Minutes or Less

625
102-628DGN 

Two-Way Left Turn Lane Closure

628
102-630DGN 

Crossover for Paving Train Operations, Rural

630
102-631DGN 

Temporary Crossover

631
102-640DGN 

Converting Two-Lanes to Four-Lanes Divided, Rural

640
102-641DGN 

Converting Two-Lanes to Four-Lanes Divided, Urban

641
102-642DGN 

Transitions for Temporary Concrete Barrier on Freeway Facilities

642
102-650DGN 

Two-Lane, Two-Way Rural Structure Replacement

650
102-651DGN 

Multilane, Divided, Maintenance and Construction

651
102-655DGN 

Traffic Pacing

655
102-660DGN 

Pedestrian Control for Closure of Sidewalks

660
102-665DGN 

Limited Access, Temporary Opening

665
102-667DGN 

Toll Plaza, Traffic Control Standards

667
102-670DGN 

Motorist Awareness System

670

Clearing Construction Site

  Clearing and Grubbing
110-100DGN 

Tree Protection and Preservation

542
110-200DGN 

Mailboxes

532
  Earthwork and Related Operations
120-001DGN 

Embankment Utilization

505
120-002DGN 

Subsoil Excavation

500
125-001DGN 

Utility Adjustments thru Existing Pavement

307
141-T01DGN 

Settlement Plate

540
160-001DGN 

Miscellaneous Earthwork Details

506

Bituminous Treatments, Surface Courses and Concrete Pavement

  Concrete Pavement
330-001DGN 

Paved and Graded Driveways

515/516
350-001DGN 

Concrete Pavement Joints

305
353-001DGN 

Concrete Slab Replacement

308
370-001DGN 

Bridge Approach Expansion Joint - Concrete Pavement

306

Structures

  Concrete Structures
400-010DGNCEL

Cantilever Retaining Wall (C-I-P)

6010
400-011DGN 

Gravity Wall

6011
400-021DGN 

Concrete Steps

521
  Inlets, Manholes and Junction Boxes
425-001DGN 

Supplementary Details for Manholes and Inlets

201
425-010DGN 

Structure Bottoms - Type J and P

200
425-020DGN 

Curb Inlet Tops - Types 1, 2, 3 and 4

210
425-021DGN 

Curb Inlet Tops - Types 5 and 6

211
425-022DGN 

Curb Inlet - Type 7

212
425-023DGN 

Curb Inlet - Type 8

213
425-024DGN 

Curb Inlet Top - Type 9

214
425-025DGN 

Curb Inlet Top - Type 10

215
425-030DGN 

Median Barrier Inlets Types 1 and 2

217
425-031DGN 

Shoulder Barrier Inlet

218
425-032DGN 

Curb and Gutter Barrier Inlet

219
425-040DGN 

Gutter Inlet - Type S

220
425-041DGN 

Gutter Inlet - Type V

221
425-050DGN 

Ditch Bottom Inlet - Type A

230
425-051DGN 

Ditch Bottom Inlet - Type B

231
425-052DGN 

Ditch Bottom Inlets - Types C, D, E and H

232
425-053DGN 

Ditch Bottom Inlets - Types F and G

233
425-054DGN 

Ditch Bottom Inlet - Type J

234
425-055DGN 

Ditch Bottom Inlet - Type K

235
425-060DGN 

Back of Sidewalk Drainage

282
425-061DGN 

Closed Flume Inlet

216
425-070DGN 

Skimmer for Outlet Control Structures

240
425-080DGN 

Utility Conflicts thru Drainage Structures

307
425-090DGN 

Safety Modifications for Inlets In Box Culverts

293
  Pipe Culverts - End Treatments
430-001DGN 

Miscellaneous Drainage Details

280
430-010DGN 

U-Type Concrete Endwalls With Grates - 15" to 30" Pipe

260
430-011DGN 

U-Type Concrete Endwalls - Baffles and Grate Optional - 15" to 30" Pipe

261
430-012DGN 

U-Type Concrete Endwall - Energy Dissipator - 30" to 72" Pipe

264
430-020DGN 

Flared End Section

270
430-021DGN 

Cross Drain Mitered End Section

272
430-022DGN 

Side Drain Mitered End Section

273
430-030DGN 

Straight Concrete Endwalls - Single and Multiple Pipe

250
430-031DGN 

Straight Concrete Endwalls - Single and Double 60" Pipe

251
430-032DGN 

Straight Concrete Endwalls - Single and Double 66" Pipe

252
430-033DGN 

Straight Concrete Endwalls - Single and Double 72" Pipe

253
430-034DGN 

Straight Concrete Endwalls - Single 84" Pipe

255
430-040DGN 

Winged Concrete Endwalls - Single Round Pipe

266
430-090DGN 

Safety Modifications for Endwalls

295
  Structures - Miscellaneous Drainage
436-001DGN 

Trench Drain

206
440-001DGN 

Underdrain

286
440-002DGN 

Underdrain Inspection Box

245
443-001DGN 

French Drain

285
443-002DGN 

Skimmers for French Drain Outlets

241
444-T01DGN 

Deep Well Injection Box

288
446-001DGN 

Concrete Pavement Subdrainage

287
  Structures Foundations - Sheet Pile Wall
455-400DGNCSPC 

CSPDA

CSPSA

Precast Concrete Sheet Pile Wall (Conventional)

6040
455-440DGNCSPC 

CSPDA

CSPSA

Precast Concrete Sheet Pile Wall (CFRP/GFRP & HSSS/GFRP)

22440

Incidental Construction

  Miscellaneous
508-T01DGN 

Traffic Control Devices for Movable Span Bridge Signals

17890
509-070DGN 

Railroad Grade Crossing Traffic Control Devices

17882
509-100DGN 

Advance Warning for R/R Crossing

17881
  Metal Pedestrian/Bicycle Railings, Guiderails and Handrails
515-052DGNCEL 

CTIP

Pedestrian/Bicycle Railing (Steel)

852
515-062DGNCEL 

CTIP

Pedestrian/Bicycle Railing (Aluminum)

862
515-070DGN 

Pipe Guiderail (Aluminum)

870
515-080DGN 

Pipe Guiderail (Steel)

880
  Concrete Gutter, Curb Elements and Traffic Separator
520-001DGN 

Curb and Gutter

300
520-005DGN 

Concrete Shoulder Gutter Spillway

284
520-010DGN 

Median Opening Flume

283
520-020DGN 

Traffic Separators

302
  Concrete Barriers, Traffic Railings, and Parapets
521-001DGN 

Concrete Barrier

410
521-002DGN 

Pier Protection Barrier

411
521-010DGN 

Opaque Visual Barrier

461
521-510DGN 

Concrete Barrier/Noise Wall (8'-0")

5210
521-511DGN 

Concrete Barrier/Noise Wall (14'-0")

5211
521-512DGN 

Concrete Barrier/Noise Wall (8'-0") Junction Slab

5212
521-513DGN 

Concrete Barrier/Noise Wall T-Shaped Spread Footing

5213
521-514DGN 

Concrete Barrier/Noise Wall L-Shaped Spread Footing

5214
521-515DGN 

Concrete Barrier/Noise Wall Trench Footing

5215
521-600DGN 

MSE Wall Coping (Precast or C-I-P)

6100
521-610DGN 

Concrete Barrier/Junction Slab - Wall Coping

6110
521-620DGN 

Concrete Barrier/Raised Sidewalk - Wall Coping

6120
521-630DGN 

Parapet With C-I-P Sidewalk - Wall Coping

6130
521-640DGN 

Drainage Inlet Openings In Junction Slab - Wall Coping

6201
521-650DGN 

Light Pole Pedestal - Wall Coping

6200
  Concrete Sidewalk and Driveways
522-001DGN 

Concrete Sidewalk

310
522-002DGN 

Detectable Warnings and Sidewalk Curb Ramps

304
522-003DGN 

Concrete Flared Driveways

515/516
  Ditch and Slope Pavement
524-001DGN 

Ditch Pavement and Sodding

281
  Noise and Perimeter Walls
534-200DGNCEL 

Graphics

Noise Walls (Precast)

5200
534-250DGNCEL

Perimeter Walls

5250
  Guardrail
536-001DGN 

Guardrail

400
536-002DGN 

Guardrail Transitions and Connections for Existing Bridges

402
  Crash Cushions
544-001DGN 

Crash Cushion Transition Details

430
  Rumble Strips
546-001DGN 

Raised Rumble Strips

517
546-010DGN 

Ground-In Rumble Strips

518
  Retaining Wall Systems
548-020DGNCEL

MSE Retaining Wall Systems (Permanent)

6020
548-030DGNCEL

MSE Retaining Wall Systems (Temporary)

6030
  Fencing
550-001DGN 

Fence - Type A

801
550-002DGN 

Fence - Type B

802
550-003DGN 

Cantilever Slide Gate - Type B Fence

803
550-004DGN 

Fence Location

800
  Performance Turf
570-001DGN 

Permanent Erosion Control

104
570-010DGN 

Shoulder Sodding and Turf on Existing Facilities

105
  Landscape
580-001DGN 

Landscape Installation

544

Traffic Control Signals and Devices

630-001DGN 

Conduit Installation Details

17721
634-001DGN 

Signal Cable and Span Wire Installation Details

17727
634-002DGN 

Aerial Interconnect

17733
635-001DGN 

Pull and Splice Boxes

17700
639-001DGN 

Service Point Details

17504
639-002DGN 

Electric Power Service

17736
641-010DGN 

Concrete Poles

17725
641-020DGN 

Concrete CCTV Pole

18113
649-010DGN 

Steel Strain Pole

17723
649-020DGN 

Steel CCTV Pole

18111
649-030DGNCEL

Standard Mast Arm Assemblies

17743
649-031DGNCEL

Mast Arm Assemblies

17745
653-001DGN 

Pedestrian Control Signal Installation Details

17764
654-001DGN 

Rectangular Rapid Flashing Beacon Assembly

11862
659-010DGN 

Span Wire Mounted Sign Details

17356
659-020DGN 

Camera Mounting Details

18110
660-001DGN 

Vehicle Loop Installation Details

17781
665-001DGN 

Pedestrian Detector Assembly Installation Details

17784
671-001DGN 

Standard Signal Operating Plans

17870
676-010DGN 

Cabinet Installation Details

17841
695-001DGN 

Traffic Monitoring Site

17900

Signing, Pavement Markings and Lighting

  Highway Signing
700-010DGN 

Single Column Ground Signs

11860
700-011DGN 

Single Column Cantilever Ground Mounted Sign

11861
700-012DGN 

Single Post Bridge Mounted Sign Support

11870
700-013DGN 

Single Post Median Barrier Mounted Sign Support

11871
700-020DGN 

Multi-Column Ground Sign

11200
700-030DGN 

Wind and Hanger Beams for Overhead Signs

11300
700-031DGN 

External Lighting for Signs

17505
700-040DGNCEL

Cantilever Sign Structure

11310
700-041DGNCEL

Span Sign Structure

11320
700-050DGN 

Free-Swinging, Internally-Illuminated Street Sign Assemblies

17748
700-090DGN 

Dynamic Message Sign Walk-In

18300
700-101DGN 

Typical Sections for Placement of Single and Multi-Column Signs

17302
700-102DGN 

Special Sign Details

17355
700-104DGN 

Signing for Motorist Services

17350
700-105DGN 

Welcome Center Signing

17351
700-106DGN 

Rural Narrow Bridge Treatment

17359
700-107DGN 

Bridge Weight Restrictions

17357
700-108DGN 

Typical Signing for Truck Weigh and Inspection Stations

17328
700-109DGN 

Traffic Controls for Street Terminations

17349
700-110DGN 

Mounting Exit Number Panels to Signs

13417
700-120DGN 

Enhanced Highway Signing Assemblies

11862
  Pavement Markings
706-001DGN 

Typical Placement of Raised Pavement Markers

17352
711-001DGN 

Pavement Markings

17346
711-002DGN 

Bicycle Markings

17347
711-003DGN 

Interchange Markings

17345
  Highway Lighting Systems
715-001DGN 

Conventional Lighting

17500
715-002DGN 

Standard Aluminum Lighting

17515
715-010DGN 

High Mast Lighting

17502
  Railroad Crossing
830-T01DGN 

Railroad (Grade) Crossings

560

 

 

 

Standard Plans for Bridge Construction

 

Standard Plans IndexDGNCEL

Index Title

Design Standards Index

General Construction Operations

  Maintenance of Traffic
102-200DGNCEL

Temporary Detour Bridge General Notes and Details

21600
102-210DGN 

Temporary Detour Bridge Details - Timber Pile Foundations

21610
102-220DGN 

Temporary Detour Bridge Details - Steel H Pile Foundations

21620
102-230DGN 

Temporary Detour Bridge Details - Steel H Pile Foundations

21630
102-240DGN 

Temporary Detour Bridge Thrie - Beam Guardrail

21640

Structures

  Concrete Structures
400-090DGNCEL

Approach Slabs (30 ft.) Flexible Pavement Approaches)

20900
400-091DGN 

Approach Slabs (30 ft.) Rigid Pavement Approaches)

20910
400-289DGNCEL

Concrete Box Culvert Details

289
400-291DGN 

Precast Concrete Box Culverts Supplemental Detail

291
400-292DGN 

Standard Precast Concrete Box Culverts

292
400-510DGN 

Composite Elastomeric Bearing Pads - Prestressed Florida-I and AASHTO Type II Beams

20510
415-001DGN 

Bar Bending Details (Steel)

21300
  Precast Prestressed Concrete Construction
450-010DGNCEL

Florida-I Beam - Typical Details and Notes

20010
450-036DGN 

Florida-I 36 Beam - Standard Details

20036
450-045DGN 

Florida-I 45 Beam - Standard Details

20045
450-054DGN 

Florida-I 54 Beam - Standard Details

20054
450-063DGN 

Florida-I 63 Beam - Standard Details

20063
450-072DGN 

Florida-I 72 Beam - Standard Details

20072
450-078DGN 

Florida-I 78 Beam - Standard Details

20078
450-084DGN 

Florida-I 84 Beam - Standard Details

20084
450-096DGN 

Florida-I 96 Beam - Standard Details

20096
450-120DGNCEL

AASHTO Type II Beam

20120
450-199DGNCEL

Prestressed I-Beams Build-Up and Deflection Data

20199
450-210DGNCEL

Florida-U Beam - Typical Details and Notes

20210
450-248DGN 

Florida-U 48 Beam - Standard Details

20248
450-254DGN 

Florida-U 54 Beam - Standard Details

20254
450-263DGN 

Florida-U 63 Beam - Standard Details

20263
450-272DGN 

Florida-U 72 Beam - Standard Details

20272
450-299DGNCEL

Florida-U Beams Build-up and Deflection Data

20299
450-502DGNCEL

Beveled Bearing Plate Details - Prestressed Florida-U Beams

20502
450-510 CEL  
450-511DGNCEL

Bearing Plates (Type 1) - Prestressed Florida-I and AASHTO Type II Beams

20511
450-512DGNCEL

Bearing Plates (Type 2) - Prestressed Florida-I and AASHTO Type II Beams

20512
  Structures Foundations
455-001DGNCEL

Square Prestressed Concrete Piles - Typical Details and Notes

20600
455-002DGN 

Square Prestressed Concrete Pile Splices

20601
455-003DGN 

Square Prestressed Concrete Piles - EDC Instrumentation

20602
455-012DGN 

12'' Square Prestressed Concrete Pile

20612
455-014DGN 

14'' Square Prestressed Concrete Pile

20614
455-018DGN 

18'' Square Prestressed Concrete Pile

20618
455-020DGN 

20'' Square Prestressed Concrete Pile

20620
455-024DGN 

24'' Square Prestressed Concrete Pile

20624
455-030DGN 

30'' Square Prestressed Concrete Pile

20630
455-031DGN 

30'' Square Prestressed Concrete Pile - High Moment Capacity

20631
455-054DGN 

54'' Precast/Post-Tensioned Concrete Cylinder Pile

20654
455-060DGN 

60'' Prestressed Concrete Cylinder Pile

20660
455-101DGN 

Square CFRP and SS Prestressed Concrete Piles - Typical Details and Notes

22600
455-102DGN 

Square CFRP and SS Prestressed Concrete Pile Splices

22601
455-112DGN 

12" Square CFRP and SS Prestressed Concrete Pile

22612
455-114DGN 

14" Square CFRP and SS Prestressed Concrete Pile

22614
455-118DGN 

18" Square CFRP and SS Prestressed Concrete Pile

22618
455-124DGN 

24" Square CFRP and SS Prestressed Concrete Pile

22624
455-130DGN 

30" Square CFRP and SS Prestressed Concrete Pile

22630
455-154DGN 

54" Precast/Post-Tensioned CFRP and SS Concrete Cylinder Pile

22654
455-160DGN 

60" Prestressed CFRP and SS Concrete Cylinder Pile

22660
  Bridge Deck Joints
458-100DGNCEL

Expansion Joint System - Strip Seal

21100
458-110DGNCEL

Expansion Joint System - Poured Joint With Backer Rod

21110
  Structural Steel and Miscellaneous Metals
460-250DGN 

Access Hatch Assembly for Steel Box Sections

21250
460-251DGN 

Access Hatch Assembly for Concrete Box Sections

21251
460-252DGNCEL

Access Door Assembly for Steel Box Sections

21252
460-470DGN 

Traffic Railing - (Thrie Beam Retrofit) Typical Details and Notes

470
460-471DGN 

Traffic Railing - (Thrie Beam Retrofit) Narrow Curb

471
460-472DGN 

Traffic Railing - (Thrie Beam Retrofit) Wide Strong Curb Type 1

472
460-473DGN 

Traffic Railing - (Thrie Beam Retrofit) Wide Strong Curb Type 2

473
460-474DGN 

Traffic Railing - (Thrie Beam Retrofit) Intermediate Curb

474
460-475DGN 

Traffic Railing - (Thrie Beam Retrofit) Wide Curb Type 1

475
460-476DGN 

Traffic Railing - (Thrie Beam Retrofit) Wide Curb Type 2

476
460-477DGN 

Thrie-Beam Panel Retrofit (Concrete Handrail)

477
460-490DGN 

Traffic Railing - (Rectangular Tube Retrofit)

 
  Post-Tensioning
462-001DGNCELb 

CELt

Post-Tensioning Vertical Profiles

21801
462-002DGN

Post-Tensioning Anchorage Protection

21802
462-003DGN

Post-Tensioning Anchorage and Tendon Filling Details

21803
  Fiber Reinforced Polymer Fender Systems
471-030DGNCEL

Fender System - Prestressed Concrete Piles and FRP Wales

21930

Incidental Construction

  Navigation Lights for Fixed Bridges
510-001DGN 

Navigation Light System Details (Fixed Bridges)

21220
  Metal Pedestrian/Bicycle Railings, Guiderails and Handrails
515-021DGN 

Pedestrian/Bicycle Bullet Railing for Traffic Railing

821
515-022DGN 

Pedestrian/Bicycle Bullet Railing Details

822
515-051DGN 

Bridge Pedestrian/Bicycle Railing (Steel)

851
515-061DGN 

Bridge Pedestrian/Bicycle Railing (Aluminum)

861
  Concrete Barriers, Traffic Railing Barriers and Parapets
521-404DGN 

Guardrail Transitions - Existing Post and Beam Bridge Railings (Narrow and Recessed Curbs)

404
521-405DGN 

Guardrail Transitions - Existing Post and Beam Bridge Railings (Wide Curbs)

405
521-422DGN 

Traffic Railing - (42" Vertical Shape)

422
521-423DGN 

Traffic Railing - (32" Vertical Shape)

423
521-426DGN 

Traffic Railing - (Median 36" Single-Slope)

426
521-427DGN 

Traffic Railing - (36" Single-Slope)

427
521-428DGN 

Traffic Railing - (42" Single-Slope)

428
521-480DGN 

Traffic Railing - (Vertical Face Retrofit) Typical Details and Notes

480
521-481DGN 

Traffic Railing - (Vertical Face Retrofit) Narrow Curb

481
521-482DGN 

Traffic Railing - (Vertical Face Retrofit) Wide Curb

482
521-483DGN 

Traffic Railing - (Vertical Face Retrofit) Intermediate Curb

483
521-484DGN 

Traffic Railing - (Vertical Face Retrofit) Spread Footing Approach

484
521-509DGN 

Traffic Railing/Noise Wall (8'-0") - Bridge

5210
521-660DGN 

Light Pole Pedestal - Bridge

5210
521-820DGN 

27" Concrete Parapet Pedestrian/Bicycle with Bullet Railing

820
521-825DGN 

42" Concrete Pedestrian/Bicycle Railing

825
  Fencing - Type R
550-010DGN 

Bridge Fencing (Vertical)

810
550-011DGN 

Bridge Fencing (Curved Top)

811
550-012DGN 

Bridge Fencing (Enclosed)

812
550-013DGN 

Bridge Fencing (Over Railroad)

812

Traffic Control Signals and Devices

  Conduit
630-010DGN 

Conduit Details - Embedded

21210

Signing, Pavement Markings and Lighting

  Highway Lighting Systems
715-240DGN 

Maintenance Lighting for Box Girders

21240