EMERGENCY INFORMATION FDOT Emergency Travel Alert:  For information on the current situation, please visit the following page - Alerts.

Office of Design

Download the free Adobe Acrobat Reader to view and/or print Indexes. Entire Index Groups may be printed by selecting the group's Index Title at the default 11 X 17 inch size. Any available Instructions for Design Standards (IDS) are listed with their related Index. For Index related questions, select the contact listed beside Index Title group headings. For use concerning plans incorporation, effective dates and for information on the Data Tables select the General Web Site Information link. For questions regarding specific Indexes, please select the appropriate Contact link (i.e. Roadway Contact, Structures Contact) to the right of the Index Title Series Group to see a list of contacts for each individual index.

 

Design Update Training

 

To skip directly to groups of Indexes, click on the index series: 100, 200, 300, 400, 500, 600, 700, 800, 5200, 6000, 11200, 13000, 17300, 17500, 17700, 17900, 18100, 20000, 20500, 20600, 20900, 21100, 21200, 21300, 21600, 21800, 21900

(Site Updated: 8/4/15)

Index Number Revision (DSR) Index Title Design Information
Instructions (IDS) Design Tools Data Table Cell Library Borderless DGNs

(PDF)

(PDF) (Link) (ZIP) (ZIP)
Terms of Use
 
Complete eBook
(252mb)

2016 Design Standards eBook

Effective Jan 1 - December 31

 

Combined  IDS
(11mb)
  Combined

CEL
(1mb)

Combined DGN

(129mb)

  COVER, TABLE OF CONTENTS AND REVISIONS  
Cover   Book Cover Cover      
Content   Table of Contents Content      
Revisions   Revision History Introduction      
Revisions
  ABBREVIATIONS AND SYMBOLS Roadway Contact
001   Standard Abbreviations        
002   Standard Symbols        
  EROSION CONTROL AND WATER QUALITY Drainage Contact
104   Permanent Erosion Control       DGN
105   Shoulder Sodding and Turf on Existing Facilities       DGN
  DRAINAGE (200-288, 293-295) Drainage Contact
(289-292) Structures Contact
200   Structure Bottoms - Type J & P       DGN
201   Supplementary Details for Manholes & Inlets   XLS   DGN
206   Trench Drain       DGN
210   Curb Inlet Tops - Types 1, 2, 3 & 4       DGN
211   Curb Inlet Tops - Types 5 & 6       DGN
212   Curb Inlet - Type 7       DGN
213   Curb Inlet - Type 8       DGN
214   Curb Inlet Top - Type 9       DGN
215   Curb Inlet Top - Type 10       DGN
216   Closed Flume Inlet       DGN
217   Median Barrier Inlets Types 1, 2, 3, 4 and 5       DGN
218   Barrier Wall Inlet       DGN
219   Concrete Barrier Wall Inlet       DGN
220   Gutter Inlet - Type S       DGN
221   Gutter Inlet - Type V       DGN
230   Ditch Bottom Inlet - Type A       DGN
231   Ditch Bottom Inlet - Type B       DGN
232   Ditch Bottom Inlets - Types C, D, E and H       DGN
233   Ditch Bottom Inlets - Types F and G       DGN
234   Ditch Bottom Inlet - Type J       DGN
235   Ditch Bottom Inlet - Type K       DGN
240   Skimmer for Outlet Control Structures IDS     DGN
241   Skimmers for Frenchdrain Outlets       DGN
245   Underdrain Inspection Box       DGN
250   Straight Concrete Endwalls - Single and Multiple Pipe       DGN
251   Straight Concrete Endwalls - Single and Double 60" Pipe       DGN
252   Straight Concrete Endwalls - Single and Double 66" Pipe       DGN
253   Straight Concrete Endwalls - Single and Double 72" Pipe       DGN
255   Straight Concrete Endwalls - Single 84" Pipe       DGN
258   Straight Sand - Cement Endwalls       DGN
260   U-Type Concrete Endwalls With Grates - 15" to 30" Pipe       DGN
261   U-Type Concrete Endwalls - Baffles and Grate Optional - 15" to 30" Pipe       DGN
264   U-Type Concrete Endwall - Energy Dissipator - 30" to 72" Pipe       DGN
266   Winged Concrete Endwalls - Single Round Pipe       DGN
268   U-Type Sand-Cement Endwalls       DGN
270   Flared End Section IDS     DGN
272   Cross Drain Mitered End Section       DGN
273   Side Drain Mitered End Section       DGN
280   Miscellaneous Drainage Details       DGN
281   Ditch Pavement and Sodding       DGN
282   Back of Sidewalk Drainage       DGN
283   Median Opening Flume       DGN
284   Concrete Shoulder Gutter Spillway       DGN
285   French Drain       DGN
286   Underdrain       DGN
287   Concrete Pavement Subdrainage       DGN
288   Deep Well Injection Box       DGN
289   Concrete Box Culvert Details (LRFD) IDS PGM CEL DGN
291   Supplemental Details for Precast Concrete Box Culverts IDS     DGN
292   Standard Precast Concrete Box Culverts IDS     DGN
293   Safety Modifications for Inlets In Box Culverts       DGN
295   Safety Modifications for Endwalls       DGN
  CURBS, CONCRETE PAVEMENT & SIDEWALKS Roadway Contact
300   Curb & Curb And Gutter       DGN
301   Turn Lanes       DGN
302   Traffic Separators IDS     DGN
303   Curb Return Profiles       DGN
304   Detectable Warnings and Sidewalk Curb Ramps IDS     DGN
305   Concrete Pavement Joints       DGN
306   Bridge Approach Expansion Joint - Concrete Pavement       DGN
307   Miscellaneous Utility Details       DGN
308   Concrete Slab Replacement       DGN
310   Concrete Sidewalk       DGN
 

TRAFFIC RAILINGS

(400-403,410-415, 430 & 461) Roadway Contact
(404,405,420-425, 470-484) Structures Contact
400   Guardrail IDS     DGN
402   Guardrail Transitions and Connections for Existing Bridges IDS     DGN
403   Guardrail Transitions for Existing Bridge Traffic Railing Retrofits IDS     DGN
404   Guardrail Transitions - Existing Post & Beam Bridge Railings (Narrow & Recessed Curbs) IDS     DGN
405   Guardrail Transitions - Existing Post & Beam Bridge Railings (Wide Curbs) IDS     DGN
410   Concrete Barrier Wall       DGN
411   Pier Protection Barrier IDS     DGN
412   Low Profile Barrier       DGN
414   Type K Temporary Concrete Barrier System IDS     DGN
415   Temporary Concrete Barrier       DGN
420   Traffic Railing - (32" F Shape) IDS     DGN
421   Traffic Railing - (Median 32" F Shape) IDS     DGN
422   Traffic Railing - (42" Vertical Shape) IDS     DGN
423   Traffic Railing - (32" Vertical Shape) IDS     DGN
424   Traffic Railing - (Corral Shape) IDS     DGN
425   Traffic Railing - (42" F Shape) IDS     DGN
430   Crash Cushion Details IDS     DGN
461   Opaque Visual Barrier       DGN
470   Traffic Railing - (Thrie Beam Retrofit) General Notes & Details IDS     DGN
471   Traffic Railing - (Thrie Beam Retrofit) Narrow Curb     DGN
472   Traffic Railing - (Thrie Beam Retrofit) Wide Strong Curb Type 1     DGN
473   Traffic Railing - (Thrie Beam Retrofit) Wide Strong Curb Type 2     DGN
474   Traffic Railing - (Thrie Beam Retrofit) Intermediate Curb     DGN
475   Traffic Railing - (Thrie Beam Retrofit) Wide Curb Type 1     DGN
476   Traffic Railing - (Thrie Beam Retrofit) Wide Curb Type 2     DGN
477   Thrie-Beam Panel Retrofit (Concrete Handrail) IDS     DGN
480   Traffic Railing - (Vertical Face Retrofit) General Notes & Details IDS     DGN
481   Traffic Railing - (Vertical Face Retrofit) Narrow Curb     DGN
482   Traffic Railing - (Vertical Face Retrofit) Wide Curb     DGN
483   Traffic Railing - (Vertical Face Retrofit) Intermediate Curb     DGN
484   Traffic Railing - (Vertical Face Retrofit) Spread Footing Approach     DGN
 

GENERAL

(500,505-535,544-560) Roadway Contact
(501,540) Structures Contact
500   Removal of Organic and Plastic Material       DGN
505   Embankment Utilization       DGN
506   Miscellaneous Earthwork Details       DGN
510   Superelevation - Rural Highways, Urban Freeways and High Speed Urban Highways       DGN
511   Superelevation - Urban Highways and Streets       DGN
514   Optional Base Group and Structural Numbers       DGN
515   Turnouts       DGN
516   Turnouts - Resurfacing Projects       DGN
517   Raised Rumble Strips       DGN
518   Shoulder Rumble Strips       DGN
519   Rumble Striping IDS     DGN
521   Concrete Steps IDS     DGN
525   Ramp Terminals       DGN
526   Roadway Transitions       DGN
527   Directional Median Openings       DGN
530   Rest Area Pavilion       DGN
532   Mailboxes       DGN
535   Tractor Crossings       DGN
540   Settlement Plate       DGN
544   Landscape Installation       DGN
546   Sight Distance at Intersections       DGN
560   Railroad Crossings       DGN
 

TRAFFIC CONTROL THROUGH WORK ZONES

Roadway Contact
600   General Information for Traffic Control Through Work Zones       DGN
601   Two-Lane, Two-Way, Work Outside Shoulder       DGN
602   Two-Lane, Two-Way, Work on Shoulder       DGN
603   Two-Lane, Two-Way, Work Within the Travel Way       DGN
604   Two-Lane, Two-Way, Work in intersection       DGN
605   Two-Lane, Two-Way, Work Near Intersection       DGN
606   Two-Lane, Two-Way, Work Within the Travel Way - Signal Control       DGN
607   Two-Lane, Two-Way, Mobile Operation, Work on Shoulder, Work Within the Travel Way       DGN
608   Two-Lane, Two-Way, Temporary Diversion Connection       DGN
611   Multilane, Work Outside Shoulder       DGN
612   Multilane, Work on Shoulder       DGN
613   Multilane, Work Within the Travel Way - Median or Outside Lane       DGN
614   Multilane, Work Within the Travel Way - Center Lane       DGN
615   Multilane, Work in Intersection       DGN
616   Multilane, Work Near Intersection - Median or Outside Lane       DGN
617   Multilane, Work in Intersection - Center Lane       DGN
618   Multilane, Work in Intersection - Two Lanes Closed - 45 mph or Less       DGN
619   Multilane, Mobile Operations, Work on Shoulder, Work Within the Travel Way       DGN
620   Multilane, Divided, Temporary Diversion Connection       DGN
621   Multilane, Undivided, Temporary Diversion Connection       DGN
622   Multilane, Work Near Intersection-Temporary Diversion Connection-35 mph or Less       DGN
623   Multilane, Work Within the Travel Way Double Lane Closure       DGN
625   Temporary Road Closure - 5 Minutes or Less       DGN
628   Two-Way Left Turn Lane Closure       DGN
630   Crossover for Paving Train Operations, Rural       DGN
631   Temporary Crossover       DGN
640   Converting Two-Lanes to Four-Lanes Divided, Rural       DGN
641   Converting Two-Lanes to Four-Lanes Divided, Urban       DGN
642   Transitions for Temporary Concrete Barrier Wall on Freeway Facilities       DGN
650   Two-Lane, Two-Way Rural Structure Replacement       DGN
651   Multilane, Divided, Maintenance and Construction       DGN
655   Traffic Pacing       DGN
660   Pedestrian Control for Closure of Sidewalks       DGN
665   Limited Access, Temporary Opening       DGN
667   Toll Plaza, Traffic Control Standards       DGN
670   Motorist Awareness System       DGN
 

ROADSIDE SAFETY

Roadway Contact
700   Roadside Offsets IDS     DGN
 

FENCING AND PEDESTRIAN RAILINGS

(800-803, 870,880) Roadway Contact
(810-862) Structures Contact
800   Fence Location       DGN
801   Fence - Type A       DGN
802   Fence - Type B       DGN
803   Cantilever Slide Gate - Type B Fence       DGN
810   Bridge Fencing (Vertical) IDS     DGN
811   Bridge Fencing (Curved Top) IDS     DGN
812   Bridge Fencing (Enclosed) IDS     DGN
820   27" Concrete Parapet Pedestrian/Bicycle with Bullet Railing IDS     DGN
821   Bridge Aluminum Pedestrian/Bicycle Bullet Railing for Traffic Railing (32" F Shape) IDS     DGN
822   Bridge Aluminum Pedestrian/Bicycle Bullet Railing Details IDS     DGN
825   42" Concrete Pedestrian/Bicycle Railing IDS     DGN
851   Bridge Pedestrian/Bicycle Railing (Steel) IDS     DGN
852   Steel Pedestrian/Bicycle Railing IDS   CEL

CEL-CTIP

DGN
861   Bridge Pedestrian/Bicycle Railing (Aluminum) IDS     DGN
862   Aluminum Pedestrian/Bicycle Railing IDS   CEL

CEL-CTIP

DGN
870   Aluminum Pipe Guiderail IDS     DGN
880   Steel Pipe Guiderail IDS     DGN
 

NOISE AND PERIMETER WALL SYSTEMS

Structures Contact
5200   Precast Noise Walls IDS   CEL

CELGraphics

DGN
5210   Traffic Railing/Noise Wall (8'-0") IDS     DGN
5211   Traffic Railing/Noise Wall (14'-0") IDS     DGN
5212   Traffic Railing/Noise Wall (8'-0") Junction Slab IDS     DGN
5213   Traffic Railing/Noise Wall T-Shape Spread Footing IDS     DGN
5214   Traffic Railing/Noise Wall L-Shaped Spread Footing IDS     DGN
5215   Traffic Railing/Noise Wall Trench Footing IDS     DGN
5250   Perimeter Walls IDS   CEL DGN
 

WALL SYSTEMS

Structures Contact
6010   C-I-P Cantilever Retaining Wall IDS PGM CEL DGN
6011   Gravity Wall IDS     DGN
6020   Permanent MSE Retaining Wall Systems IDS   CEL DGN
6030   Temporary MSE Retaining Wall Systems IDS   CEL DGN
6040   Precast Concrete Sheet Pile Wall IDS   CEL-CSPDA
CEL-CSPC

CEL-CSPSA

DGN
6100   MSE Wall Coping (Precast or C-I-P) IDS     DGN
6110   Wall Coping With Traffic Railing/Junction Slab     DGN
6120   Wall Coping With Traffic Railing/Raised Sidewalk     DGN
6130   Wall Coping/Parapet With C-I-P Sidewalk     DGN
6200   Coping Mounted Light Pole Pedestal       DGN
6201   Junction Slab at Drainage Inlet Openings       DGN
 

SIGNING AND MARKING

Roadway Contact
11200   Multi-Column Ground Sign IDS PGM   DGN
11300   Steel Overhead Sign Structures IDS     DGN
11310   Cantilever Sign Structure IDS PGM CEL DGN
11320   Span Sign Structure IDS PGM CEL DGN
11860   Single Column Ground Signs IDS     DGN
11861   Single Column Cantilever Ground Mounted Sign IDS     DGN
11862   Roadside Flashing Beacon Assembly       DGN
11870   Single Post Bridge Mounted Sign Support IDS     DGN
11871   Single Post Median Barrier Mounted Sign Support IDS     DGN
13417   Mounting Exit Number Panels to Highway Signs       DGN
17302   Typical Sections for Placement of Single & Multi-Column Signs       DGN
17328   Typical Signing for Truck Weigh and Inspection Stations       DGN
17344   School Signs & Markings       DGN
17345   Interchange Markings       DGN
17346   Special Marking Areas       DGN
17347   Bicycle Markings IDS     DGN
17349   Traffic Controls for Street Terminations       DGN
17350   Signing for Motorist Services       DGN
17351   Welcome Center Signing       DGN
17352   Typical Placement of Reflective Pavement Markers       DGN
17354   Tourist Oriented Directional Signs       DGN
17355   Special Sign Details       DGN
17356   Span Wire Mounted Sign Details       DGN
17357   Bridge Weight Restrictions       DGN
17359   Rural Narrow Bridge Treatment       DGN
 

ROADWAY LIGHTING

Roadway Contact
17500   Conventional Lighting       DGN
17501   Highway Lighting General Notes       DGN
17502   High Mast Lighting IDS PGM   DGN
17504   Service Point Details       DGN
17505   External Lighting for Signs IDS     DGN
17515   Standard Aluminum Lighting IDS     DGN
 

TRAFFIC SIGNAL AND EQUIPMENT

Roadway Contact
17700   Pull and Splice Box       DGN
17721   Conduit Installation Details       DGN
17723   Steel Strain Pole IDS PGM   DGN
17725   Concrete Poles IDS PGM   DGN
17727 DSR Signal Cable and Span Wire Installation Details       DGN
17733   Aerial Interconnect       DGN
17736   Electric Power Service       DGN
17743   Standard Mast Arm Assemblies IDS PGM CEL DGN
17745   Mast Arm Assemblies IDS PGM CEL DGN
17748   Free-Swinging, Internally-Illuminated Street Sign Assemblies       DGN
17764   Pedestrian Control Signal Installation Details       DGN
17781   Vehicle Loop Installation Details       DGN
17784   Pedestrian Detector Assembly Installation Details       DGN
17841   Cabinet Installation Details       DGN
17870   Standard Signal Operating Plans       DGN
17881   Advance Warning for R/R Crossing       DGN
17882   Railroad Grade Crossing Traffic Control Devices       DGN
17890   Traffic Control Devices for Movable Span Bridge Signals       DGN
 

PLANNING

Roadway Contact
17900   Traffic Monitoring Site IDS     DGN
 

INTELLIGENT TRANSPORTATION SYSTEMS

Intelligent Transportation Systems Contact
18100   CCTV Pole Placement       DGN
18101   Typical CCTV Site       DGN
18102   Grounding and Lightning Protection       DGN
18104   Typical CCTV Cabinet Equipment Layout       DGN
18105   CCTV Block Diagram       DGN
18107   Ground Mounted CCTV Cabinet       DGN
18108   Pole Mounted CCTV Cabinet       DGN
18110   Camera Mounting Details       DGN
18111   Steel CCTV Pole IDS     DGN
18113   Concrete CCTV Pole IDS     DGN
18300   Dynamic Message Sign Walk-In       DGN
 

PRESTRESSED CONCRETE BEAMS

Structures Contact
20010   Typical Florida-I Beam Details and Notes IDS PGM CEL DGN
20036   Florida-I 36 Beam - Standard Details DGN
20045   Florida-I 45 Beam - Standard Details DGN
20054   Florida-I 54 Beam - Standard Details DGN
20063   Florida-I 63 Beam - Standard Details DGN
20072   Florida-I 72 Beam - Standard Details DGN
20078   Florida-I 78 Beam - Standard Details DGN
20084   Florida-I 84 Beam - Standard Details DGN
20096   Florida-I 96 Beam - Standard Details DGN
20120   AASHTO Type II Beam IDS PGM CEL DGN
20199   Build-Up & Deflection Data for Prestressed I-Beams IDS   CEL DGN
20210   Typical Florida-U Beam Details and Notes IDS PGM CEL DGN
20248   Florida-U 48 Beam - Standard Details DGN
20254   Florida-U 54 Beam - Standard Details DGN
20263   Florida-U 63 Beam - Standard Details DGN
20272   Florida-U 72 Beam - Standard Details DGN
20299   Build-up and Deflection Data for Florida-U Beams IDS   CEL DGN
 

BRIDGE BEARINGS

Structures Contact
20502   Beveled Bearing Plate Details - Prestressed Florida-U Beams IDS   CEL DGN
20510   Composite Elastomeric Bearing Pads - Prestressed Florida-I & AASHTO Type II Beams IDS   CEL DGN
20511   Bearing Plates (Type I) - Prestressed Florida-I & AASHTO Type II Beams IDS   CEL DGN
20512   Bearing Plates (Type 2) - Prestressed Florida-I & AASHTO Type II Beams IDS   CEL DGN
 

SQUARE AND ROUND CONCRETE PILES

Structures Contact
20600   Notes and Details for Square Prestressed Concrete Piles IDS   CEL DGN
20601   Square Prestressed Concrete Pile Splices DGN
20602   EDC Instrumentation for Square Prestressed Concrete Piles DGN
20612   12'' Square Prestressed Concrete Pile DGN
20614   14'' Square Prestressed Concrete Pile DGN
20618   18'' Square Prestressed Concrete Pile DGN
20620   20'' Square Prestressed Concrete Pile DGN
20624   24'' Square Prestressed Concrete Pile DGN
20630   30'' Square Prestressed Concrete Pile DGN
20631   High Moment Capacity 30'' Square Prestressed Concrete Pile DGN
20654   54'' Precast/Post-Tensioned Concrete Cylinder Pile IDS DGN
20660   60'' Prestressed Concrete Cylinder Pile IDS DGN
 

APPROACH SLABS

Structures Contact
20900   Approach Slabs (Flexible Pavement Approaches) IDS   CEL DGN
20910   Approach Slabs (Rigid Pavement Approaches) IDS   CEL DGN-
 

BRIDGE EXPANSION JOINTS

Structures Contact
21100   Strip Seal Expansion Joint IDS   CEL DGN
21110   Poured Joint With Backer Rod Expansion Joint System IDS   CEL DGN
 

STRUCTURES ACCESS AND LIGHTING

Structures Contact
21200   Light Pole Pedestal IDS     DGN
21210   Conduit Details IDS     DGN
21220   Navigation Light System Details (Fixed Bridges) IDS     DGN
21240   Maintenance Lighting for Box Girders IDS     DGN
21250   Access Hatch Assembly for Steel Box Sections IDS     DGN
21251   Access Hatch Assembly for Concrete Box Sections     DGN
21252   Access Door Assembly for Steel Box Sections IDS   CEL DGN
 

STANDARD BAR BENDING DETAILS

Structures Contact
21300   Standard Bar Bending Details IDS     DGN
 

TEMPORARY DETOUR BRIDGES

Structures Contact
21600   Temporary Detour Bridge General Notes and Details IDS   CEL DGN
21610   Temporary Detour Bridge Details -Timber Pile Foundations DGN
21620   Temporary Detour Bridge Details -Steel H Pile Foundations DGN
21630   Temporary Detour Bridge Details -Steel Pipe Pile Foundations DGN
21640   Temporary Detour Bridge Thrie-Beam Guardrail DGN
 

POST-TENSIONING

Structures Contact
21801   Post-Tensioning Vertical Profiles IDS   CEL-b  CEL-t DGN
21802   Post-Tensioning Anchorage Protection DGN
21803   Post-Tensioning Anchorage and Tendon Filling Details DGN
 

FENDER SYSTEM DETAILS

Structures Contact
21930   Fender System -Prestressed Concrete Piles IDS   CEL DGN